Sheng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sheng Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Xiaodong Sun
Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
3 shared publications - Xiao Wu
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Blvd, Ann Arbor, MI 48109, United States of America
2 shared publications Xiaodong Sun
2 shared publications- Zhe Li
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
2 shared publications - Adam Burak
Department of Nuclear Engineering and Radiological Sciences, University of Michigan 1 , Ann Arbor, Michigan 48109
1 shared publication Hsun-Chia Lin
University of Michigan, Department of Nuclear Engineering and Radiological Sciences, Ann Arbor, Michigan 48109
1 shared publication
Latest Publications
- Open Access
A Comprehensive Review of Printed Circuit Heat Exchangers: Fabrication, Thermal–Hydraulic Performance, and Reliability
Printed circuit heat exchangers (PCHEs) represent a critical technology for application in advanced energy systems due to their compact configuration, exceptional thermal efficiency, and robustness under extreme temperatures and pressures. This review systematically examines PCHE technology, covering key fabrication processes—including material selection, channel etching, and diffusion bonding—alongside the thermal–hydraulic performances of various channel geometries and optimization strategies. Although considerable progress has been made in geometric optimization—with reported heat transfer enhancements of up to 250% and flow resistance reductions of up to 84.7%—most of the available optimized designs remain confined to numerical analyses. A significant gap persists between these idealized models and real manufacturing constraints, where etching and inducing geometric deviations inherently affect both performance and mechanical integrity. Moreover, current Nusselt number and friction factor correlations lack universality, and mechanical integrity assessments often neglect long-term degradation mechanisms such as fouling. This review identifies these critical gaps and proposes that future research should prioritize integrating geometric optimization with fabrication feasibility and mechanical integrity. Also, there is a need to develop generalized correlations that incorporate both fluid property variations and geometric effects, and to systematically evaluate long-term performance via component-scale testing.
Open AccessA Comprehensive Review of Printed Circuit Heat Exchangers: Fabrication, Thermal–Hydraulic Performance, and Reliability
Printed circuit heat exchangers (PCHEs) represent a critical technology for application in advanced energy systems due to their compact configuration, exceptional thermal efficiency, and robustness under extreme temperatures and pressures. This review systematically examines PCHE technology, covering key fabrication processes—including material selection, channel etching, and diffusion bonding—alongside the thermal–hydraulic performances of various channel geometries and optimization strategies. Although considerable progress has been made in geometric optimization—with reported heat transfer enhancements of up to 250% and flow resistance reductions of up to 84.7%—most of the available optimized designs remain confined to numerical analyses. A significant gap persists between these idealized models and real manufacturing constraints, where etching and inducing geometric deviations inherently affect both performance and mechanical integrity. Moreover, current Nusselt number and friction factor correlations lack universality, and mechanical integrity assessments often neglect long-term degradation mechanisms such as fouling. This review identifies these critical gaps and proposes that future research should prioritize integrating geometric optimization with fabrication feasibility and mechanical integrity. Also, there is a need to develop generalized correlations that incorporate both fluid property variations and geometric effects, and to systematically evaluate long-term performance via component-scale testing.
- 4 August 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 253
Gaussian process regression for predictions of mixed convection in horizontal pipe flows
- 4 August 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 253
Gaussian process regression for predictions of mixed convection in horizontal pipe flows
- Open Access
- 6 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (3) , 1091-1099
Thermal dehydration tests of FLiNaK salt for thermal-hydraulic experiments
- 6 February 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (3) , 1091-1099
Open AccessThermal dehydration tests of FLiNaK salt for thermal-hydraulic experiments
- 25 August 2022
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 197 (5) , 920-946
Thermal-Hydraulic System-Level Analysis of a Molten Salt Natural Circulation Loop
Molten salt reactors (MSRs) are a class of Generation IV nuclear reactors using molten salts as heat transfer fluids. MSRs bring a number of benefits, including low primary system working pressure, high working temperature, and enhanced safety due to the passive safety systems adopted. Although MSRs promise these benefits, a number of key technology needs, such as the accurate prediction of the thermal-hydraulic performance of the passive safety systems, which completely rely on natural circulation, are indispensable for MSR development, licensing, and future deployment. Therefore, this study develops the one-dimensional (1D) NAtural Circulation COde (NACCO) considering the buoyancy and radiative heat transfer effects in high-temperature molten salts for such predictions. The 1D code, developed using MATLAB, is then benchmarked with experimental data from three natural circulation flow experiments, where water, nitrate salt NaNO3-KNO3 (60–40 wt%), and fluoride salt LiF-BeF2 (66–34 mol%, FLiBe) were used as the working fluids. Our analysis shows that (1) the buoyancy and radiative heat transfer effects need to be considered for high-temperature molten salt natural circulation flows, while the radiative heat transfer effect is negligible for low-temperature water flows in the natural circulation experiments investigated, and (2) the 1D code NACCO predicts salt temperature profiles reasonably well, with less than 18°C and 25°C discrepancies from experimental data for the pipe centerline temperature of NaNO3-KNO3 and FLiBe up to 450°C and 750°C, respectively.
- 25 August 2022
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 197 (5) , 920-946
Thermal-Hydraulic System-Level Analysis of a Molten Salt Natural Circulation Loop
Molten salt reactors (MSRs) are a class of Generation IV nuclear reactors using molten salts as heat transfer fluids. MSRs bring a number of benefits, including low primary system working pressure, high working temperature, and enhanced safety due to the passive safety systems adopted. Although MSRs promise these benefits, a number of key technology needs, such as the accurate prediction of the thermal-hydraulic performance of the passive safety systems, which completely rely on natural circulation, are indispensable for MSR development, licensing, and future deployment. Therefore, this study develops the one-dimensional (1D) NAtural Circulation COde (NACCO) considering the buoyancy and radiative heat transfer effects in high-temperature molten salts for such predictions. The 1D code, developed using MATLAB, is then benchmarked with experimental data from three natural circulation flow experiments, where water, nitrate salt NaNO3-KNO3 (60–40 wt%), and fluoride salt LiF-BeF2 (66–34 mol%, FLiBe) were used as the working fluids. Our analysis shows that (1) the buoyancy and radiative heat transfer effects need to be considered for high-temperature molten salt natural circulation flows, while the radiative heat transfer effect is negligible for low-temperature water flows in the natural circulation experiments investigated, and (2) the 1D code NACCO predicts salt temperature profiles reasonably well, with less than 18°C and 25°C discrepancies from experimental data for the pipe centerline temperature of NaNO3-KNO3 and FLiBe up to 450°C and 750°C, respectively.
- 12 March 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 190
Mixed convective heat transfer of medium-Prandtl-number fluids in horizontal circular tubes
- 12 March 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 190
Mixed convective heat transfer of medium-Prandtl-number fluids in horizontal circular tubes
- Open Access
- 16 July 2021
- Published by ASME International
Numerical Study of Tritium Mitigation Strategies for Fluoride Salt-Cooled High-Temperature Reactors
Fluoride salt-cooled High-temperature Reactor (FHR) is one of the advanced non-Light Water Reactor (non-LWR) designs, which adopts a low-pressure fluoride salt as the primary coolant, high working temperatures, coated-particle fuel, and a passive safety system for decay heat removal. However, tritium management is perceived as a critical issue in FHRs since tritium is a radiation
- 16 July 2021
- Published by ASME International
Open AccessNumerical Study of Tritium Mitigation Strategies for Fluoride Salt-Cooled High-Temperature Reactors
Fluoride salt-cooled High-temperature Reactor (FHR) is one of the advanced non-Light Water Reactor (non-LWR) designs, which adopts a low-pressure fluoride salt as the primary coolant, high working temperatures, coated-particle fuel, and a passive safety system for decay heat removal. However, tritium management is perceived as a critical issue in FHRs since tritium is a radiation
- 3 July 2020
- Published by Taylor & Francis in Nuclear Technology
- Vol. 206 (11) , 1721-1739
Convective and Radiative Heat Transfer in Molten Salts
Molten salts have been proposed as heat transfer media due to their superior thermal performance at elevated temperatures. A number of heat transfer correlations have been proposed in the literature for molten salts without explicitly considering the radiative heat transfer effect in the salts, which may not be negligible. This study therefore attempts to (1) quantitatively analyze the convective and radiative heat transfer of molten salts using an overall heat transfer model that includes a radiative heat transfer model developed in this research and an existing conventional convective heat transfer model/correlation, such as the Sieder-Tate or Hausen correlation, and (2) provide rationale on under what conditions it is necessary to consider the radiative heat transfer effect in salts. A parametric study was performed using the radiative heat transfer model developed to investigate the effects of various input variables, including the tube size (inner diameter 5 to 50 mm), salt temperature (500°C to 1000°C), salt and wall temperature difference (5°C to 100°C), and salt absorption coefficient (1 to 100 m-1). Our study indicates that (1) the proposed overall heat transfer model reasonably predicts the salt convective and radiative heat transfer, (2) the radiative heat transfer is more important for laminar flows than transitional and turbulent flows, (3) the radiative heat transfer is more important in tubes of larger inner diameter, (4) the salt temperature affects the radiative heat transfer significantly while the temperature difference between the salt and wall has a slightly smaller effect for the range investigated (ΔT = 5°C to 100°C), and (5) the salt absorption coefficient significantly affects the salt radiative heat transfer.
- 3 July 2020
- Published by Taylor & Francis in Nuclear Technology
- Vol. 206 (11) , 1721-1739
Convective and Radiative Heat Transfer in Molten Salts
Molten salts have been proposed as heat transfer media due to their superior thermal performance at elevated temperatures. A number of heat transfer correlations have been proposed in the literature for molten salts without explicitly considering the radiative heat transfer effect in the salts, which may not be negligible. This study therefore attempts to (1) quantitatively analyze the convective and radiative heat transfer of molten salts using an overall heat transfer model that includes a radiative heat transfer model developed in this research and an existing conventional convective heat transfer model/correlation, such as the Sieder-Tate or Hausen correlation, and (2) provide rationale on under what conditions it is necessary to consider the radiative heat transfer effect in salts. A parametric study was performed using the radiative heat transfer model developed to investigate the effects of various input variables, including the tube size (inner diameter 5 to 50 mm), salt temperature (500°C to 1000°C), salt and wall temperature difference (5°C to 100°C), and salt absorption coefficient (1 to 100 m-1). Our study indicates that (1) the proposed overall heat transfer model reasonably predicts the salt convective and radiative heat transfer, (2) the radiative heat transfer is more important for laminar flows than transitional and turbulent flows, (3) the radiative heat transfer is more important in tubes of larger inner diameter, (4) the salt temperature affects the radiative heat transfer significantly while the temperature difference between the salt and wall has a slightly smaller effect for the range investigated (ΔT = 5°C to 100°C), and (5) the salt absorption coefficient significantly affects the salt radiative heat transfer.
- 2 July 2017
- Published by ASME International
Double-Wall Natural Draft Heat Exchanger Design for Tritium Control in FHRs
Tritium control is potentially a critical issue for Fluoride salt-cooled High-temperature Reactors (FHRs) and Molten Salt Reactors (MSRs). Tritium production rate in these reactors can be significantly higher compared to that in Light Water Reactors (LWRs). Tritium is highly permeable at high temperatures through reactor structures, especially. Therefore, heat exchangers with large heat transfer areas in FHRs and MSRs provide practical paths for the tritium generated in the primary salt migrating into the surroundings, such as Natural Draft Heat Exchangers (NDHXs) in the direct reactor auxiliary cooling system (DRACS), which are proposed as a passive decay heat removal system for these reactors. A double-wall heat exchanger design was proposed in the literature to significantly minimize the tritium release rate to the environment in FHRs. This unique shell and tube heat exchanger design adopts a three-fluid design concept and each of the heat exchanger tube consists of an inner tube and an outer tube. Each of these tube units forms three flow passages, i.e., the inner channel, annular channel, and outer channel. While this type of heat exchangers was proposed, few such heat exchangers have been designed in the literature, taking into account both heat and tritium mass transfer performance. In this study, a one-dimensional heat and mass transfer model was developed to assist the design of a double-wall NDHX for FHRs. In this model, the molten salt and air flow through the inner and outer channels, respectively. A selected sweep gas acting as a tritium removal medium flows in the annular channel and takes tritium away to minimize tritium leakage to the air flowing in the outer channel. The heat transfer model was benchmarked against a Computational Fluid Dynamics (CFD) code, i.e., ANSYS Fluent. Good agreement was obtained between the model simulation and Fluent analysis. In addition, the heat and mass transfer models combined with non-dominated sorting in generic algorithms (NSGA) were applied to investigate a potential NDHX design in Advanced High-Temperature Reactor (AHTR), a pre-conceptual FHR design developed by the Oak Ridge National Laboratory. A double-wall NDHX design using inner and outer fluted tubes was therefore optimized and compared with a single-wall design in terms of performance and economics.
- 2 July 2017
- Published by ASME International
Double-Wall Natural Draft Heat Exchanger Design for Tritium Control in FHRs
Tritium control is potentially a critical issue for Fluoride salt-cooled High-temperature Reactors (FHRs) and Molten Salt Reactors (MSRs). Tritium production rate in these reactors can be significantly higher compared to that in Light Water Reactors (LWRs). Tritium is highly permeable at high temperatures through reactor structures, especially. Therefore, heat exchangers with large heat transfer areas in FHRs and MSRs provide practical paths for the tritium generated in the primary salt migrating into the surroundings, such as Natural Draft Heat Exchangers (NDHXs) in the direct reactor auxiliary cooling system (DRACS), which are proposed as a passive decay heat removal system for these reactors. A double-wall heat exchanger design was proposed in the literature to significantly minimize the tritium release rate to the environment in FHRs. This unique shell and tube heat exchanger design adopts a three-fluid design concept and each of the heat exchanger tube consists of an inner tube and an outer tube. Each of these tube units forms three flow passages, i.e., the inner channel, annular channel, and outer channel. While this type of heat exchangers was proposed, few such heat exchangers have been designed in the literature, taking into account both heat and tritium mass transfer performance. In this study, a one-dimensional heat and mass transfer model was developed to assist the design of a double-wall NDHX for FHRs. In this model, the molten salt and air flow through the inner and outer channels, respectively. A selected sweep gas acting as a tritium removal medium flows in the annular channel and takes tritium away to minimize tritium leakage to the air flowing in the outer channel. The heat transfer model was benchmarked against a Computational Fluid Dynamics (CFD) code, i.e., ANSYS Fluent. Good agreement was obtained between the model simulation and Fluent analysis. In addition, the heat and mass transfer models combined with non-dominated sorting in generic algorithms (NSGA) were applied to investigate a potential NDHX design in Advanced High-Temperature Reactor (AHTR), a pre-conceptual FHR design developed by the Oak Ridge National Laboratory. A double-wall NDHX design using inner and outer fluted tubes was therefore optimized and compared with a single-wall design in terms of performance and economics.