DŠDagmar Štěpánová

Dagmar Štěpánová

*This is an algorithmically generated author record based on publicly available information.

Dagmar Štěpánová has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of Heliospheric Modulation Potential Reconstruction from Lomnický štít Neutron Monitor Data

    by Ján Kubančák, Iva Ambrožová, Roman Dvorak, Giovanni Santin, Martin Kakona, Ronald Langer, KateřIna Pachenerová Brabcová, Šimon Mackovjak, Igor Strhársky, Samuel Štefánik, et al.

    Aircrew exposure to cosmic radiation is recognised as occupational exposure in the European Union and is commonly evaluated using approved computational tools, including the Federal Aviation Administration (FAA) CARI code, which requires monthly values of the heliospheric modulation potential (hereafter HP; referred to as “heliocentric potential” in FAA documentation) and to date has been supplied exclusively by the FAA. We previously developed an independent European HP database reconstructed from count rates of the Lomnický štít 8NM64 neutron monitor (LMKS). The present study tests whether LMKS-derived HP values can replace FAA reference HP values as input to CARI7 within the ±20 % uncertainty band reported in the EURADOS inter-code comparison. CARI7 was run twice over 248,496 in-flight segments (latitudes 0–69◦ , altitudes 0–41,338 ft) under otherwise identical conditions, using only the HP source as the differing input, and the resulting pairs were compared for four CARI7 output quantities: 𝐷 Si , 𝐻*(10), 𝐸 (ICRP 60), and 𝐸 103 (ICRP 103). Across all four quantities the FAA → LMKS bias was 1.4–2.3 %, the 95 % limits of agreement stayed within ±11 %, Lin’s concordance correlation coefficient exceeded 0.990, two one-sided tests (TOST) accepted equivalence at 𝛿 = 5 % of the mean (𝑝 < 0.001), and 100 % of segments fell inside ±20 % in every one of 64 latitude × altitude bins. As an independent cross-check, residual distributions of Liulin-measured minus CARI7-computed dose from the CR10 onboard database were indistinguishable between potentials. The FAA → LMKS effect on effective dose (+2.16 %) is approximately four times smaller than the CARI6 → CARI7 model-version step (−8.88 %, 99.9 % of segments inside ±20 %). LMKS derived HP values are therefore interchangeable with FAA HP values for operational aircrew dosimetry.

  • Open Access

    Recent and historic values of heliospheric modulation potential based on Lomnický štít data

    by Ján Kubančák, Iva Ambrožová, Martin Kakona, Ronald Langer, KateřIna Pachenerová Brabcová, Šimon Mackovjak, Igor Strhársky, Samuel Štefánik, Jakub Šlegl, Roman Dvořák, et al.

    In the European Union, radiation exposure of aircrew to cosmic radiation is classified as occupational exposure and must be routinely assessed. Personal doses are typically calculated using dedicated software tools. In Slovakia and Czechia, aircrew doses are commonly evaluated using the Federal Aviation Administration (FAA) CARI code, which is freely available and widely accepted. A limitation of CARI is its reliance on monthly values of the heliospheric modulation potential (hereafter HP; referred to as “heliocentric potential” in FAA documentation), which are currently provided exclusively by the FAA and derived from neutron monitor observations. The purpose of this work is to establish an independent European source of HP values based on measurements from the Lomnický štít standard 8NM64 neutron monitor (commonly referred to as LMKS, 2634 m a.s.l., vertical cutoff rigidity 3.84 GV). We present the methodology for deriving HP from LMKS data, evaluate candidate regression models against FAA reference values, and assess the statistical performance and operational applicability of the selected model. The results demonstrate that LMKS data provide a reliable basis for HP reconstruction and may support operational applications, including flight planning and optimization of crew radiation protection.

  • Measurements of radiation induced by a spark discharge under laboratory conditions

    by Dagmar Kyselová, Jan Mikeš, Václav Štěpán, Iva Ambrožová, Eric R. Benton, Marek Sommer, Michal Krbal, Luděk Pelikán, Ondřej Ploc, Günther Reitz