Lisa M. Johnson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lisa M. Johnson has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Alicia Algeciras-Schimnich
Department of Laboratory Medicine and Pathology, Mayo Clinic , Rochester, MN 55901 , USA
1 shared publicationEric Goold
Department of Pathology, University of Utah, Salt Lake City, UT 84108, USA
1 shared publicationGabrielle Jensen
ARUP Institute for Clinical and Experimental Pathology , Salt Lake City, UT , USA
1 shared publicationGeralyn Lambert-Messerlian
Department of Pathology and Laboratory Medicine, Women and Infants Hospital , Providence, RI 02905 , USA
1 shared publicationGrace M. Kroner
Department of Pathology, University of Utah, 500 Chipeta Way, Salt Lake City, UT 84108, USA
1 shared publicationHailey Bs Hall
ARUP Laboratories, Salt Lake City, UT
1 shared publication
Latest Publications
- 14 May 2022
- Published by Elsevier in Clinical Biochemistry
- Vol. 107, 19-23
Comparison of fecal calprotectin and pancreatic elastase assays based on proficiency testing results
- 14 May 2022
- Published by Elsevier in Clinical Biochemistry
- Vol. 107, 19-23
Comparison of fecal calprotectin and pancreatic elastase assays based on proficiency testing results
- 26 March 2022
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 7 (4) , 1000-1002
PAPP-A Results Cannot Be Used to Accurately Estimate Gestational Age
- 26 March 2022
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 7 (4) , 1000-1002
PAPP-A Results Cannot Be Used to Accurately Estimate Gestational Age
- 1 March 2022
- Published by Wolters Kluwer Health in Pancreas
- Vol. 51 (3) , 243-249
Clinical and Analytical Characterization of the DiaSorin and ScheBo Fecal Pancreatic Elastase 1 Assays
Objectives: Fecal pancreatic elastase (PE) assays are screening tests for exocrine pancreatic insufficiency (EPI). We analytically evaluated a new PE assay and retrospectively analyzed data from an academic hospital and reference laboratory to understand the clinical utility. Methods: Forty stool samples with different PE concentrations were tested on the ScheBo enzyme-linked immunosorbent assay (ELISA) versus DiaSorin LIAISON immunoassay; a simple-to-use extraction device was assessed. The cross-reactivity of porcine enzymes was investigated in the immunoassay. Charts of 207 patients with PE results less than 250 μg/g at an academic hospital were reviewed, and data were analyzed for 5136 patients with repeat PE results from a reference laboratory. Results: The LIAISON immunoassay gave comparable results to the ScheBo ELISA, with 87.5% agreement of PE results in classifying as sufficient, mild/moderate insufficiency, or severe insufficiency. The extraction device worked well compared with manual weighing, and no cross reactivity with porcine enzymes was observed. In agreement with prior studies, our clinical data suggested that PE assays were most useful in detecting severe EPI. Conclusions: The new DiaSorin LIAISON immunoassay preforms similarly to the well-known ScheBo ELISA. Pancreatic elastase assays can help identify patients with severe EPI but are not as useful in classifying mild/moderate EPI.
- 1 March 2022
- Published by Wolters Kluwer Health in Pancreas
- Vol. 51 (3) , 243-249
Clinical and Analytical Characterization of the DiaSorin and ScheBo Fecal Pancreatic Elastase 1 Assays
Objectives: Fecal pancreatic elastase (PE) assays are screening tests for exocrine pancreatic insufficiency (EPI). We analytically evaluated a new PE assay and retrospectively analyzed data from an academic hospital and reference laboratory to understand the clinical utility. Methods: Forty stool samples with different PE concentrations were tested on the ScheBo enzyme-linked immunosorbent assay (ELISA) versus DiaSorin LIAISON immunoassay; a simple-to-use extraction device was assessed. The cross-reactivity of porcine enzymes was investigated in the immunoassay. Charts of 207 patients with PE results less than 250 μg/g at an academic hospital were reviewed, and data were analyzed for 5136 patients with repeat PE results from a reference laboratory. Results: The LIAISON immunoassay gave comparable results to the ScheBo ELISA, with 87.5% agreement of PE results in classifying as sufficient, mild/moderate insufficiency, or severe insufficiency. The extraction device worked well compared with manual weighing, and no cross reactivity with porcine enzymes was observed. In agreement with prior studies, our clinical data suggested that PE assays were most useful in detecting severe EPI. Conclusions: The new DiaSorin LIAISON immunoassay preforms similarly to the well-known ScheBo ELISA. Pancreatic elastase assays can help identify patients with severe EPI but are not as useful in classifying mild/moderate EPI.
- 1 December 2021
- Published by Elsevier in Clinical Biochemistry
- Vol. 98, 78-80
Hereditary pancreatitis in a young adult: Acute to chronic
- 1 December 2021
- Published by Elsevier in Clinical Biochemistry
- Vol. 98, 78-80
Hereditary pancreatitis in a young adult: Acute to chronic
- 14 August 2021
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 157 (2) , 252-256
Comparison of Next-Generation Assays for Fecal Calprotectin vs the PhiCal Assay
Objectives: To compare the PhiCal assay (CALPRO), the first US Food and Drug Administration–approved assay for fecal calprotectin, to 4 next-generation assays. Methods: Stool samples from 50 patients were selected, and relevant clinical information was collected. Comparisons were performed using the PhiCal, fCAL turbo (BÜHLMANN), LIAISON Calprotectin (DiaSorin), QUANTA Lite Calprotectin ELISA (Inova Diagnostics), and Calprotectin Chemiluminescence ELISA (ALPCO) assays. Results: All 4 assays had acceptable agreement with PhiCal when qualitatively categorizing results. Within the PhiCal reportable range of 16 to 1,250 μg/g, the DiaSorin, Inova Diagnostics, and ALPCO assays had Spearman correlation coefficients of 0.98, 0.97, and 0.95 and positive biases of 17%, 20%, and 15%, respectively. The BÜHLMANN assay ran approximately 2-fold higher than the PhiCal assay but had a correlation coefficient of 0.98, with similar result categorization. Conclusions: Our results demonstrate good comparison between PhiCal and 4 next-generation assays. Laboratories performing fecal calprotectin assays may have compelling reasons to adopt next-generation fecal calprotectin testing, such as greater automation, a decreased number of replicates needed per test, and the use of stool-extraction devices. These benefits could decrease turnaround times and lower costs. Although the results of the assays correlated, they are not standardized. Laboratories adopting the newer assays will need to further investigate their performance through validation studies.
- 14 August 2021
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 157 (2) , 252-256
Comparison of Next-Generation Assays for Fecal Calprotectin vs the PhiCal Assay
Objectives: To compare the PhiCal assay (CALPRO), the first US Food and Drug Administration–approved assay for fecal calprotectin, to 4 next-generation assays. Methods: Stool samples from 50 patients were selected, and relevant clinical information was collected. Comparisons were performed using the PhiCal, fCAL turbo (BÜHLMANN), LIAISON Calprotectin (DiaSorin), QUANTA Lite Calprotectin ELISA (Inova Diagnostics), and Calprotectin Chemiluminescence ELISA (ALPCO) assays. Results: All 4 assays had acceptable agreement with PhiCal when qualitatively categorizing results. Within the PhiCal reportable range of 16 to 1,250 μg/g, the DiaSorin, Inova Diagnostics, and ALPCO assays had Spearman correlation coefficients of 0.98, 0.97, and 0.95 and positive biases of 17%, 20%, and 15%, respectively. The BÜHLMANN assay ran approximately 2-fold higher than the PhiCal assay but had a correlation coefficient of 0.98, with similar result categorization. Conclusions: Our results demonstrate good comparison between PhiCal and 4 next-generation assays. Laboratories performing fecal calprotectin assays may have compelling reasons to adopt next-generation fecal calprotectin testing, such as greater automation, a decreased number of replicates needed per test, and the use of stool-extraction devices. These benefits could decrease turnaround times and lower costs. Although the results of the assays correlated, they are not standardized. Laboratories adopting the newer assays will need to further investigate their performance through validation studies.
- 1 July 2021
- Published by Elsevier in Clinica Chimica Acta
- Vol. 518, 38-42
Retrospective comparison of results for simultaneous orders for LDL particle count, apolipoprotein B, and LDL-C
- 1 July 2021
- Published by Elsevier in Clinica Chimica Acta
- Vol. 518, 38-42
Retrospective comparison of results for simultaneous orders for LDL particle count, apolipoprotein B, and LDL-C
- 1 October 2020
- Published by Elsevier in Clinical Biochemistry
- Vol. 84, 51-54
Can fecal calprotectin serve as a screen for necrotizing enterocolitis in infants?
- 1 October 2020
- Published by Elsevier in Clinical Biochemistry
- Vol. 84, 51-54