Enrique Sanchis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Enrique Sanchis has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Vicente Gonzalez
Universitat de València
58 shared publications E. Higon
Department of Atomic, Molecular and Nuclear Physics and Instituto de Física Corpuscular, University of Valencia, Burjassot, 46100, Spain
35 shared publications- A. Ferrer
U. de Valencia
30 shared publications A. Zaitsev
22 shared publications- Andres Gadea
Instituto de Fisica Corpuscular
22 shared publications M. Lokajicek
21 shared publications
Latest Publications
- 15 October 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 114 (4) , 044318
Direct transfer to K 46 , 48 as a survey of the π ( s 1 / 2 ) − ν ( s d p f ) interaction
Nucleon-adding and -removing transfer reactions provide a unique experimental window into the anatomy of the shell-model picture of atomic nuclei. The authors put the neutron-removing transfer reaction 47K(d,t) and the neutron-adding counterpart 47K(d,p) to work for meticulously probing our understanding of the neutron shell structure and interaction of the last valence proton in 46K. With that, they provided a unique benchmark for the nuclear shell model on the quest to describe shell evolution in neutron-rich nuclei.
- 15 October 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 114 (4) , 044318
Direct transfer to K 46 , 48 as a survey of the π ( s 1 / 2 ) − ν ( s d p f ) interaction
Nucleon-adding and -removing transfer reactions provide a unique experimental window into the anatomy of the shell-model picture of atomic nuclei. The authors put the neutron-removing transfer reaction 47K(d,t) and the neutron-adding counterpart 47K(d,p) to work for meticulously probing our understanding of the neutron shell structure and interaction of the last valence proton in 46K. With that, they provided a unique benchmark for the nuclear shell model on the quest to describe shell evolution in neutron-rich nuclei.
- Open Access
- 17 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105894
Audiovisual guidance for beam stopper positioning in intraoperative electron radiotherapy
- 17 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148, 105894
Open AccessAudiovisual guidance for beam stopper positioning in intraoperative electron radiotherapy
- Open Access
- 3 April 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (4)
Anomalous quadrupole transition probabilities in the f 7 / 2 mirror nuclei
Lifetimes of several excited states in the mirror nuclei Cr 47 − V 47 and Mn 49 − Cr 49 , located at the center of the f 7 / 2 shell, were measured using the advanced γ -ray tracking array AGATA. The Doppler shift attenuation method was employed to determine such lifetimes in the subpicosecond range. The reduced transition probabilities obtained from the lifetimes are compared to shell-model calculations in the full f p space. The shell-model-calculated B ( E 2 ) values were underestimated in comparison with experimental data. In particular, large discrepancies are obtained in Mn 49 at low spin. These results suggest an incomplete understanding of low-energy states in the studied nuclei and call for further refinement of the existing nuclear structure theories.
- 3 April 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (4)
Open AccessAnomalous quadrupole transition probabilities in the f 7 / 2 mirror nuclei
Lifetimes of several excited states in the mirror nuclei Cr 47 − V 47 and Mn 49 − Cr 49 , located at the center of the f 7 / 2 shell, were measured using the advanced γ -ray tracking array AGATA. The Doppler shift attenuation method was employed to determine such lifetimes in the subpicosecond range. The reduced transition probabilities obtained from the lifetimes are compared to shell-model calculations in the full f p space. The shell-model-calculated B ( E 2 ) values were underestimated in comparison with experimental data. In particular, large discrepancies are obtained in Mn 49 at low spin. These results suggest an incomplete understanding of low-energy states in the studied nuclei and call for further refinement of the existing nuclear structure theories.
- 25 April 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (16) , 162504
Probing Exotic Cross-Shell Interactions at with Single-Neutron Transfer onWe present the first measurement of the $^{47}\mathrm{K}(d,p\ensuremath{\gamma})^{48}\mathrm{K}$ transfer reaction, performed in inverse kinematics using a reaccelerated beam of $^{47}\mathrm{K}$. The level scheme of $^{48}\mathrm{K}$ has been greatly extended, with nine new bound excited states identified and spectroscopic factors deduced. Uniquely, the $^{47}\mathrm{K}(d,p)$ reaction gives access to nuclear states that are sensitive to the interaction of protons and neutrons in the widely spaced $1s$ and $fp$ orbitals, respectively. Detailed comparisons with SDPF-U and SDPF-MU shell-model calculations reveal a number of discrepancies between theory and experiment. Intriguingly, a systematic overestimation of spectroscopic factors and a poor reproduction of the energies for ${1}^{\ensuremath{-}}$ states suggests that the mixing between the $\ensuremath{\pi}{s}_{1/2}^{1}{d}_{3/2}^{4}$ and $\ensuremath{\pi}{s}_{1/2}^{2}{d}_{3/2}^{3}$ proton configurations in $^{48}\mathrm{K}$ is not correctly described using current interactions, challenging our description of light nuclei around the $N=28$ island of inversion.- 25 April 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (16) , 162504
Probing Exotic Cross-Shell Interactions at with Single-Neutron Transfer onWe present the first measurement of the $^{47}\mathrm{K}(d,p\ensuremath{\gamma})^{48}\mathrm{K}$ transfer reaction, performed in inverse kinematics using a reaccelerated beam of $^{47}\mathrm{K}$. The level scheme of $^{48}\mathrm{K}$ has been greatly extended, with nine new bound excited states identified and spectroscopic factors deduced. Uniquely, the $^{47}\mathrm{K}(d,p)$ reaction gives access to nuclear states that are sensitive to the interaction of protons and neutrons in the widely spaced $1s$ and $fp$ orbitals, respectively. Detailed comparisons with SDPF-U and SDPF-MU shell-model calculations reveal a number of discrepancies between theory and experiment. Intriguingly, a systematic overestimation of spectroscopic factors and a poor reproduction of the energies for ${1}^{\ensuremath{-}}$ states suggests that the mixing between the $\ensuremath{\pi}{s}_{1/2}^{1}{d}_{3/2}^{4}$ and $\ensuremath{\pi}{s}_{1/2}^{2}{d}_{3/2}^{3}$ proton configurations in $^{48}\mathrm{K}$ is not correctly described using current interactions, challenging our description of light nuclei around the $N=28$ island of inversion.- Open Access
- 1 January 2024
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 16 (5) , 335-343
Impact of MRI-based planning in transperineal interstitial brachytherapy for vaginal-involving tumors
Purpose: The purpose of the study was to analyze patients with vaginal-involving recurrences of gynecological tumors and primary vaginal tumors, treated with transperineal interstitial brachytherapy (P-ISBT). Dosimetric, clinical, and toxicity analysis of these patients was conducted,...
- 1 January 2024
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 16 (5) , 335-343
Open AccessImpact of MRI-based planning in transperineal interstitial brachytherapy for vaginal-involving tumors
Purpose: The purpose of the study was to analyze patients with vaginal-involving recurrences of gynecological tumors and primary vaginal tumors, treated with transperineal interstitial brachytherapy (P-ISBT). Dosimetric, clinical, and toxicity analysis of these patients was conducted,...
- Open Access
- 5 September 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-7
Search for 22Na in novae supported by a novel method for measuring femtosecond nuclear lifetimes
Classical novae are thermonuclear explosions in stellar binary systems, and important sources of 26Al and 22Na. While γ rays from the decay of the former radioisotope have been observed throughout the Galaxy, 22Na remains untraceable. Its half-life (2.6 yr) would allow the observation of its 1.275 MeV γ-ray line from a cosmic source. However, the prediction of such an observation requires good knowledge of its nucleosynthesis. The 22Na(p, γ)23Mg reaction remains the only source of large uncertainty about the amount of 22Na ejected. Its rate is dominated by a single resonance on the short-lived state at 7785.0(7) keV in 23Mg. Here, we propose a combined analysis of particle-particle correlations and velocity-difference profiles to measure femtosecond nuclear lifetimes. The application of this method to the study of the 23Mg states, places strong limits on the amount of 22Na produced in novae and constrains its detectability with future space-borne observatories.
- 5 September 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-7
Open AccessSearch for 22Na in novae supported by a novel method for measuring femtosecond nuclear lifetimes
Classical novae are thermonuclear explosions in stellar binary systems, and important sources of 26Al and 22Na. While γ rays from the decay of the former radioisotope have been observed throughout the Galaxy, 22Na remains untraceable. Its half-life (2.6 yr) would allow the observation of its 1.275 MeV γ-ray line from a cosmic source. However, the prediction of such an observation requires good knowledge of its nucleosynthesis. The 22Na(p, γ)23Mg reaction remains the only source of large uncertainty about the amount of 22Na ejected. Its rate is dominated by a single resonance on the short-lived state at 7785.0(7) keV in 23Mg. Here, we propose a combined analysis of particle-particle correlations and velocity-difference profiles to measure femtosecond nuclear lifetimes. The application of this method to the study of the 23Mg states, places strong limits on the amount of 22Na produced in novae and constrains its detectability with future space-borne observatories.
- Open Access
- 24 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (23) , 6937
High-Intensity Interval Training (HIIT) on Biological and Body Composition Variables in Patients with Musculoskeletal Disorders: A Systematic Review and Meta-Analysis
In order to assess the impact of high-intensity interval training (HIIT) on biological and body composition variables in patients with musculoskeletal disorders (MSKD), a systematic search on PubMed (Medline), CENTRAL, CINAHL, Web of Science, SPORTDiscus, and Scopus was conducted. Standardized mean differences (SMD) and 95% confidence intervals were calculated and pooled in a meta-analysis using the random-effects model. The effectiveness of HIIT on waist circumference, muscle mass, resting heart rate, resting systolic and diastolic blood pressure, C-reactive protein, body weight, and body fat were determined. GRADE, risk of bias 2, and PEDro scales were employed. HIIT compared to no intervention, minimal intervention, or usual care did not show significant results in its favor on any of the variables studied, except for the resting heart rate when compared with no intervention (SMD = −0.33; 95% CI: −0.63, −0.04; heterogeneity Q value: 0.14; p = 0.93; I2 = 0%). In addition, HIIT also does not seem to be more effective than moderate-intensity continuous training. Based on the results, it seems that HIIT has almost no significant effects on biological and body composition variables, except for resting heart rate, in patients with MSKD.
- 24 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (23) , 6937
Open AccessHigh-Intensity Interval Training (HIIT) on Biological and Body Composition Variables in Patients with Musculoskeletal Disorders: A Systematic Review and Meta-Analysis
In order to assess the impact of high-intensity interval training (HIIT) on biological and body composition variables in patients with musculoskeletal disorders (MSKD), a systematic search on PubMed (Medline), CENTRAL, CINAHL, Web of Science, SPORTDiscus, and Scopus was conducted. Standardized mean differences (SMD) and 95% confidence intervals were calculated and pooled in a meta-analysis using the random-effects model. The effectiveness of HIIT on waist circumference, muscle mass, resting heart rate, resting systolic and diastolic blood pressure, C-reactive protein, body weight, and body fat were determined. GRADE, risk of bias 2, and PEDro scales were employed. HIIT compared to no intervention, minimal intervention, or usual care did not show significant results in its favor on any of the variables studied, except for the resting heart rate when compared with no intervention (SMD = −0.33; 95% CI: −0.63, −0.04; heterogeneity Q value: 0.14; p = 0.93; I2 = 0%). In addition, HIIT also does not seem to be more effective than moderate-intensity continuous training. Based on the results, it seems that HIIT has almost no significant effects on biological and body composition variables, except for resting heart rate, in patients with MSKD.
- Open Access
- 2 September 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-7
Importance of frequency and intensity of strength training for work ability among physical therapists
The aim of the study was to evaluate the association between frequency and intensity of strength training participation and work ability among physical therapists (PTs). The Work Ability Index questionnaire (WAI) and a questionnaire about participation in strength training during leisure time were administered to a sample of Spanish PTs. In addition, participants provided information on gender, age, body mass index, education, substance use, working experience and working hours per week. The odds for having excellent WAI (score 44–49) as a function of intensity or frequency of strength training participation were determined using binary logistic regression controlled for various confounders. Data from 981 PTs were analysed. High-intensity strength training (> 80% 1 RM) showed strong associations with excellent WAI (odds ratio = 9.7; 95% confidence interval, 2.9–31.6). In addition, performing strength training more than 3 times per week was associated with excellent WAI (odds ratio = 1.79; 95% confidence interval, 1.24–2.59), however, no significant associations were found with lower levels of frequency and intensities. High-intensity strength training 3 times per week is associated with excellent WAI among PTs. Training programs meeting these features may importantly contribute to maintain or improve WAI.
- 2 September 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-7
Open AccessImportance of frequency and intensity of strength training for work ability among physical therapists
The aim of the study was to evaluate the association between frequency and intensity of strength training participation and work ability among physical therapists (PTs). The Work Ability Index questionnaire (WAI) and a questionnaire about participation in strength training during leisure time were administered to a sample of Spanish PTs. In addition, participants provided information on gender, age, body mass index, education, substance use, working experience and working hours per week. The odds for having excellent WAI (score 44–49) as a function of intensity or frequency of strength training participation were determined using binary logistic regression controlled for various confounders. Data from 981 PTs were analysed. High-intensity strength training (> 80% 1 RM) showed strong associations with excellent WAI (odds ratio = 9.7; 95% confidence interval, 2.9–31.6). In addition, performing strength training more than 3 times per week was associated with excellent WAI (odds ratio = 1.79; 95% confidence interval, 1.24–2.59), however, no significant associations were found with lower levels of frequency and intensities. High-intensity strength training 3 times per week is associated with excellent WAI among PTs. Training programs meeting these features may importantly contribute to maintain or improve WAI.
- Open Access
- 3 January 2022
- Published by Elsevier in Physica Medica
- Vol. 94, 35-42
Embedded bleeding detector into a PMMA applicator for electron intraoperative radiotherapy
- 3 January 2022
- Published by Elsevier in Physica Medica
- Vol. 94, 35-42
Open AccessEmbedded bleeding detector into a PMMA applicator for electron intraoperative radiotherapy
- 21 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (4) , 4786-4792
Electronic Design for a Bleeding Detector to be Used in Intraoperative Radiotherapy Applications
An electronic design for a bleeding detector used with mobile linac during intraoperative radiotherapy (IORT) is presented. It consists on a readout circuit based on a De Sauty Bridge and a wireless power supply using a supercapacitor. The goal is the measurement of the height of fluid present in the applicator in order to avoid a misadministration dose during the irradiation process. A minimum measurement height of 5 mm is required by clinic to be confident with the selected radiation dose. The measurement circuit uses a capacitive sensor which detects variations lower than 0.1 pF. The readout circuit converts dynamic capacitance variation from the bleeding detector into an analog voltage signal. Tests have been performed with a 40 mm diameter polymethyl methacrylate applicator (PMMA) using water. Non-bevelled PMMA 0° and 45° tilted have been considered, being this the worst condition used in the clinic. The actual height of the fluid with respect to that measured by our system shows good linearity and repeatability within acceptable limits. For 0° tilted, a 2 mm height fluid detection is achieved well below the 5 mm height demanded by clinic. For 45° tilted, a 5 mm height fluid detection is achieved.
- 21 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (4) , 4786-4792
Electronic Design for a Bleeding Detector to be Used in Intraoperative Radiotherapy Applications
An electronic design for a bleeding detector used with mobile linac during intraoperative radiotherapy (IORT) is presented. It consists on a readout circuit based on a De Sauty Bridge and a wireless power supply using a supercapacitor. The goal is the measurement of the height of fluid present in the applicator in order to avoid a misadministration dose during the irradiation process. A minimum measurement height of 5 mm is required by clinic to be confident with the selected radiation dose. The measurement circuit uses a capacitive sensor which detects variations lower than 0.1 pF. The readout circuit converts dynamic capacitance variation from the bleeding detector into an analog voltage signal. Tests have been performed with a 40 mm diameter polymethyl methacrylate applicator (PMMA) using water. Non-bevelled PMMA 0° and 45° tilted have been considered, being this the worst condition used in the clinic. The actual height of the fluid with respect to that measured by our system shows good linearity and repeatability within acceptable limits. For 0° tilted, a 2 mm height fluid detection is achieved well below the 5 mm height demanded by clinic. For 45° tilted, a 5 mm height fluid detection is achieved.