DCDesheng Cheng

Desheng Cheng

*This is an algorithmically generated author record based on publicly available information.

Desheng Cheng has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study on Dynamic Characteristics of High Speed Projectile Impacting Concrete Target

    by Desheng Cheng, Wenjing Pu, Lingling Huang

    In this paper, the dynamic characteristics of projectile penetrating concrete target at high speed are studied. The mechanism of high-speed projectile penetration into target plate is analyzed theoretically. Through ANSYS-LSDYNA numerical modeling, a numerical model is established, and a suitable grid model is divided. The numerical calculation of projectile deflection, kinetic energy loss, stress distribution and overload characteristics of high-speed projectile penetration into target plate is carried out. The calculation results show that the software simulation method can better reflect the phenomenon of the high-speed projectile penetrating into the concrete pit. The penetration speed of the projectile has an impact on the projectile offset, kinetic energy loss, stress distribution and overload characteristics during the penetration process, but these effects are not linear, especially the overload characteristics of the projectile. The overload of the projectile penetration process exists in the form of shock pulses, The characteristics of shock pulse overload have great influence on the structure design of projectile.


  • Open Access

    Numerical investigation of thermo hydraulic characteristics of monoblock module of EAST divertor

    by Desheng Cheng, Weihua Wang, Bo Shi, Haifei Deng, Wei Lu, Shenhao Wang

    The Engineering design of divertor is one of the most important topics in nuclear fusion research. The primary problem in the design of divertor is to discharge the large amount of energy from high-energy plasma particles to ensure that the operation of fusion devices can be safe and stable for a long time. Based on the temperature of the divertor target plate measured in a discharge of the EAST experimental device, we carry out numerical simulations to examine the thermal and hydraulic performance of the Monoblock module. The ANSYS software is used for the simulations on the fluid-solid coupling phenomenon of a simplified model. The ANSYS parallel module and 30 CPUs are used for parallel computing, and periodic temperature pulses are loaded on the top surface of a tungsten divertor tile to investigate the thermo-hydraulic characteristics of Monoblock module. We find the pattern in which the distributions of temperature and heat flux change over time. The maximum temperature mainly depends on the peak heat flux of high-energy particles and the duration of pulses, The temperature of the interface of each component and of coolant outlet are all related to the density of discharge pulse and the duration of discharge, and the temperature of the interface of each component will reach to an equilibrium under the condition of stable discharge heat flow. The results provide support for the structural design of a stable EAST divertor.


  • Study of Temperature and Heat Flux on the EAST Divertor Target Plate in LHW+ NBI/ICRH H-Mode

    by Bo Shi, Cheng Yang, Zhendong Yang, Desheng Cheng, Hui Wang, Jinhong Yang, Hui Zhang, Junli Qi, Qianghua Zhang, Xianzu Gong, et al.

    The heat fluxes on the lower outer divertor plate were calculated using the DFLUX code with the surface temperature measured by the IR camera on the experimental advanced superconducting tokamak. The analyzed discharges were lower single-null divertor configuration discharges with different auxiliary heating: lower hybrid wave current drive (LHCD) combined with neutral beam injection (NBI) and LHCD combined with ion cyclotron resonant heating (ICRH). The surface temperature of the lower outer divertor target plate was about 170 °C in the LHCD + NBI H-mode, with the high temperature mostly distributed in the location near the joint of the dome and the outer target plate. The temperature increased as the NBI was turned on and fluctuated due to edge localized modes (ELMs). The heat flux reached nearly 4 MW/m 2 when ELMs appeared and declined to less than 1 MW/m 2 when the NBI was turned off. Temperature distribution with extreme toroidal asymmetry was observed in the selected LHCD + ICRH H-mode discharge. The surface temperature on the lower outer divertor target plate was up to 220 °C in one region with broader temperature distribution. During the LHCD + ICRH H-mode, the peak heat flux was not seen during the period of ICRH injection, though a brief spike in heat flux was observed at the beginning of the ICRH injection. The full-width at half-maximum of the heat flux profile as a function of divertor target plate location of the LHCD + ICRH H-mode is three times that of the LHCD + NBI H-mode.


  • Design and Analysis of “Filling-Evacuating” High-Pressure Helium-Cooled Loop

    by Haifei Deng, Weihua Wang, Desheng Cheng, Shenghong Huang, Jinhon Yang, Junli Qi

    The breeder blanket and divertor are crucial plasma facing components in a fusion reactor. The helium cooled blanket and divertor concepts have exhibited the best potential to come up to the highest safety requirements and therefore been chosen for the development object. As a result of high heat flux radiated from the plasma in the fusion reactor and high power density nuclear heat deposited by high-energy neutrons, the cooling of the first wall (FW) and the discharge of nuclear heat have become one of the major technical challenges. To demonstrate and verify the helium-cooled technology and tools of China test blanket module, and explore the feasibility and key technology of thermal hydraulics process of helium-cooled divertor, we have creatively adopted the ``filling-evacuating'' approach to design and fabricate the high-pressure helium-cooled loop (HPHCL), in which a mock-up of reduced-scale helium-cooled blanket module is designed and manufactured as a test section. Based on different experimental cases, the operating pressures of helium at mock-up range from 3 to 10 MPa and the maximum mass flow rate can reach up to 0.21 kg/s. In this paper, the design scheme of the HPHCL is presented, and the key issues of engineering manufacture and the test cases are calculated and analyzed. The helium gas flow and the heat transfer are calculated according to the test working conditions of the referenced International Thermonuclear Experimental Reactor TBM's FW surface heat flux, using ANSYS fluid dynamics software FLUENT. The results will provide support for the follow-up fabrication of test system and implementation of the tests.

  • The Experimental Investigation of Wetting Property for Liquid Lead Bismuth Alloy With ADS Materials

    by Wei Lu, Weihua Wang, Desheng Cheng, Guizhong Zuo, Haiyan Jiang, Baoguo Pan, Delin Chu, Wei Xu, Jiansheng Hu

    The accelerator-driven subcritical system (ADS) has potential economy and safety and relatively mature technology base, which has been chosen as a priority development advanced nuclear system. Liquid lead bismuth eutectic (LBE) is selected as the spallation target material and core coolant. The reduced activation ferritic/martensitic (RAFM) steel and the silicon carbide composite (SiC f ) are selected as its structural material and functional material, respectively. In the present experimental investigation, the special vacuum experimental device has been built, and the “dispensed droplet” modification of the classic sessile droplet technique has been used to investigate the wetting property and interfacial interactions for LBE/RAFM steel, LBE/316L, LBE/SiC, and LBE/SiCf couples. The contact angles were measured between the liquid LBE and the various candidate materials under working temperature from 300 °C to 480 °C. The results could provide meaningful compatibility database of liquid LBE and valuable engineering design reference of candidate structural materials and functional material for future ADS.