JEJason A. Ellis

Jason A. Ellis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jason A. Ellis has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Charles W. Emala

    Department of Anesthesiology, Columbia University Medical Center, New York, NY, USA

    1 shared publication
  • Irving J. Bigio

    Department of Biomedical Engineering Boston University Boston Massachusetts USA

    1 shared publication
  • Jeffrey N. Bruce

    Department of Neurological Surgery, Columbia University Medical Center, New York, NY, USA

    1 shared publication
  • Johann Cooke

    Department of Anesthesiology, Columbia University Medical Center, New York, NY, USA

    1 shared publication
  • Mei Wang

    Department of Anesthesiology, Columbia University Medical Center, New York, NY, USA

    1 shared publication
  • Rajinder P. Singh-Moon

    Department of Electrical Engineering, Columbia University, New York, NY, USA

    1 shared publication

Latest Publications

  • Safety, feasibility, and optimization of intra-arterial mitoxantrone delivery to gliomas

    by Jason A. Ellis, Johann Cooke, Rajinder P. Singh-Moon, Mei Wang, Jeffrey N. Bruce, Charles W. Emala, Irving J. Bigio, Shailendra Joshi

    Mitoxantrone is a highly cytotoxic antineoplastic drug, however, its poor penetration of the blood–brain barrier has limited its role in the treatment of brain cancers. We hypothesize that intra-arterial (IA) delivery of mitoxantrone may enhance its capacity for regional brain deposition thus expanding its potential as a brain tumor therapy agent. In this study we assessed the dose-response characteristics as well as the feasibility and safety of mitoxantrone delivery to the brain and specifically to gliomas in a rodent model. We show that delivery optimization utilizing the technique of intra-arterial transient cerebral hypoperfusion (IA-TCH) facilitates achieving the highest peak- and end- brain drug concentrations as compared to intravenous and IA delivery without hypoperfusion. Additionally, we observed significant tumor-specific uptake of mitoxantrone when delivered by the IA-TCH method. No untoward effects of IA-TCH delivery of mitoxantrone were observed. The IA-TCH method is shown to be a safely tolerated and feasible strategy for delivering mitoxantrone to tumors in the glioma model tested. Additional investigation is warranted to determine if IA-TCH delivery of mitoxantrone produces clinically relevant benefit.