Jason A. Ellis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jason A. Ellis has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Charles W. Emala
Department of Anesthesiology, Columbia University Medical Center, New York, NY, USA
1 shared publication- Irving J. Bigio
Department of Biomedical Engineering Boston University Boston Massachusetts USA
1 shared publication Jeffrey N. Bruce
Department of Neurological Surgery, Columbia University Medical Center, New York, NY, USA
1 shared publicationJohann Cooke
Department of Anesthesiology, Columbia University Medical Center, New York, NY, USA
1 shared publicationMei Wang
Department of Anesthesiology, Columbia University Medical Center, New York, NY, USA
1 shared publicationRajinder P. Singh-Moon
Department of Electrical Engineering, Columbia University, New York, NY, USA
1 shared publication
Latest Publications
- 30 August 2016
- Published by Springer Nature in Journal of Neuro-Oncology
- Vol. 130 (3) , 449-454
Safety, feasibility, and optimization of intra-arterial mitoxantrone delivery to gliomas
Mitoxantrone is a highly cytotoxic antineoplastic drug, however, its poor penetration of the blood–brain barrier has limited its role in the treatment of brain cancers. We hypothesize that intra-arterial (IA) delivery of mitoxantrone may enhance its capacity for regional brain deposition thus expanding its potential as a brain tumor therapy agent. In this study we assessed the dose-response characteristics as well as the feasibility and safety of mitoxantrone delivery to the brain and specifically to gliomas in a rodent model. We show that delivery optimization utilizing the technique of intra-arterial transient cerebral hypoperfusion (IA-TCH) facilitates achieving the highest peak- and end- brain drug concentrations as compared to intravenous and IA delivery without hypoperfusion. Additionally, we observed significant tumor-specific uptake of mitoxantrone when delivered by the IA-TCH method. No untoward effects of IA-TCH delivery of mitoxantrone were observed. The IA-TCH method is shown to be a safely tolerated and feasible strategy for delivering mitoxantrone to tumors in the glioma model tested. Additional investigation is warranted to determine if IA-TCH delivery of mitoxantrone produces clinically relevant benefit.
- 30 August 2016
- Published by Springer Nature in Journal of Neuro-Oncology
- Vol. 130 (3) , 449-454
Safety, feasibility, and optimization of intra-arterial mitoxantrone delivery to gliomas
Mitoxantrone is a highly cytotoxic antineoplastic drug, however, its poor penetration of the blood–brain barrier has limited its role in the treatment of brain cancers. We hypothesize that intra-arterial (IA) delivery of mitoxantrone may enhance its capacity for regional brain deposition thus expanding its potential as a brain tumor therapy agent. In this study we assessed the dose-response characteristics as well as the feasibility and safety of mitoxantrone delivery to the brain and specifically to gliomas in a rodent model. We show that delivery optimization utilizing the technique of intra-arterial transient cerebral hypoperfusion (IA-TCH) facilitates achieving the highest peak- and end- brain drug concentrations as compared to intravenous and IA delivery without hypoperfusion. Additionally, we observed significant tumor-specific uptake of mitoxantrone when delivered by the IA-TCH method. No untoward effects of IA-TCH delivery of mitoxantrone were observed. The IA-TCH method is shown to be a safely tolerated and feasible strategy for delivering mitoxantrone to tumors in the glioma model tested. Additional investigation is warranted to determine if IA-TCH delivery of mitoxantrone produces clinically relevant benefit.