Burcu Tunc
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Burcu Tunc has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Murat Gulsoy
Boğaziçi University
5 shared publications - Melike Guney Akkurt
İstanbul Medeniyet Üniversitesi
2 shared publications Murat Gulsoy
Bogaziçi Univ. (Turkey)
2 shared publicationsMurat Gülsoy
Bogaziçi Univ. (Turkey)
2 shared publicationsA. H. Ucisik
Boğaziçi University
1 shared publicationB. Büyüksaraç
Department of Biomedical Engineering, Baheehir University, Istanbul-Turkey
1 shared publication
Latest Publications
- Open Access
- 25 October 2026
- Published by Frontiers in Life Sciences and Related Technologies in Frontiers in Life Sciences and Related Technologies
- Vol. 7, 155-166
Phenotype-specific medication-related changes in nonlinear Poincaré descriptors of postural sway in Parkinson’s disease
Postural instability is a major source of disability and fall risk in Parkinson’s disease (PD), yet the effect of dopaminergic medication on balance remains inconsistent. One possible explanation is clinical heterogeneity, particularly between tremor-dominant (TD) and postural-instability/gait-difficulty (PIGD) phenotypes. In this study, nonlinear Poincaré descriptors were calculated from postural sway data to examine whether they changed with medication state differently in these two phenotypes. In a public dataset of 32 individuals with idiopathic PD, 31 participants were classified as PIGD (n=12) or TD (n=19). Quiet-standing center-of-pressure (CoP) signals were examined in OFF and ON medication states under four stance conditions combining rigid or unstable surface with eyes open or closed. Pre-filtered CoP signals were downsampled to 25 Hz and analyzed separately in the anteroposterior and mediolateral directions using lag-1 Poincaré plots to obtain SD1, SD2, and SD1/SD2, which were also compared with conventional, entropy-based, and fractal measures. Medication-related changes tended to be larger and more often positive in the PIGD group, whereas TD patients showed little systematic change. The clearest between-phenotype differences (nominal p<.05) were observed for mediolateral SD1 on an unstable surface with eyes closed, mediolateral SD2 on a rigid surface with eyes closed, and the anteroposterior SD1/SD2 ratio on an unstable surface with eyes closed; given the number of comparisons and the modest sample, these findings should be regarded as exploratory. These findings suggest that motor phenotype should be considered when interpreting medication effects on posturography in PD, and that the SD1/SD2 ratio, which closely tracked entropy- and fractal-based measures, offers a simple, parameter-free index of medication-related changes in the temporal structure of sway.
- 25 October 2026
- Published by Frontiers in Life Sciences and Related Technologies in Frontiers in Life Sciences and Related Technologies
- Vol. 7, 155-166
Open AccessPhenotype-specific medication-related changes in nonlinear Poincaré descriptors of postural sway in Parkinson’s disease
Postural instability is a major source of disability and fall risk in Parkinson’s disease (PD), yet the effect of dopaminergic medication on balance remains inconsistent. One possible explanation is clinical heterogeneity, particularly between tremor-dominant (TD) and postural-instability/gait-difficulty (PIGD) phenotypes. In this study, nonlinear Poincaré descriptors were calculated from postural sway data to examine whether they changed with medication state differently in these two phenotypes. In a public dataset of 32 individuals with idiopathic PD, 31 participants were classified as PIGD (n=12) or TD (n=19). Quiet-standing center-of-pressure (CoP) signals were examined in OFF and ON medication states under four stance conditions combining rigid or unstable surface with eyes open or closed. Pre-filtered CoP signals were downsampled to 25 Hz and analyzed separately in the anteroposterior and mediolateral directions using lag-1 Poincaré plots to obtain SD1, SD2, and SD1/SD2, which were also compared with conventional, entropy-based, and fractal measures. Medication-related changes tended to be larger and more often positive in the PIGD group, whereas TD patients showed little systematic change. The clearest between-phenotype differences (nominal p<.05) were observed for mediolateral SD1 on an unstable surface with eyes closed, mediolateral SD2 on a rigid surface with eyes closed, and the anteroposterior SD1/SD2 ratio on an unstable surface with eyes closed; given the number of comparisons and the modest sample, these findings should be regarded as exploratory. These findings suggest that motor phenotype should be considered when interpreting medication effects on posturography in PD, and that the SD1/SD2 ratio, which closely tracked entropy- and fractal-based measures, offers a simple, parameter-free index of medication-related changes in the temporal structure of sway.
- 1 September 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 126, 110648
Deep neural network approach for estimating the three-dimensional human center of mass using joint angles
- 1 September 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 126, 110648
Deep neural network approach for estimating the three-dimensional human center of mass using joint angles
- 8 October 2019
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 52 (3) , 235-246
The Comparison of Thermal Effects of a 1940‐nm Tm:fiber Laser and 980‐nm Diode Laser on Cortical Tissue: Stereotaxic Laser Brain Surgery
Background and Objectives: The thermal damage on adjacent healthy structures is always an unwanted consequence of continuous‐wave laser irradiation of soft tissues. To propose a laser as an effective alternative to traditional surgical tools, this photothermal damage due to heat conduction must be taken into account with a detailed laser dosimetry study. Two candidate lasers; a 980‐nm diode and 1940‐nm Tm:fiber were selected for this study. Despite the poor absorption by water, the 980‐nm diode laser has been one of the most widely used lasers in soft tissue surgeries due its good absorption by hemoglobin, which provides good homeostasis. The second laser; the Tm:fiber laser was selected due to its wavelength operating at an absorption peak of water (1,940 nm), which makes it a good candidate for ablation of biological tissues, and it is readily capable of being transmitted through flexible fiber optics to deliver energy to hard‐to‐reach regions. The underlying motivation for the research described in this paper is that with a comprehensive comparison of ablation capabilities and a detailed dose study of infrared lasers operating at different wavelengths and temperature monitoring of the tissue during laser surgery, it may be possible to specify the optimal laser parameters for laser surgery, and propose a treatment alternative to conventional surgical techniques in clinical use. The objectives of this study were to investigate and to compare the thermal effects of 980‐nm and 1940‐nm lasers on cortical tissue in vivo, to find the optimum parameters for laser‐brain‐ablation with minimum thermal damage to the surrounding healthy tissue, and finally, to analyze laser irradiated tissue thermographically and histologically to correlate thermal events and tissue damage with laser irradiation parameters.Study Design/Materials and Methods: Stereotaxic laser brain surgeries were performed on 32 male Wistar rats. A t‐type thermocouple was used to measure the temperature of the nearby tissue at a distance of 1 mm above and 1 mm away from the fiber tip during laser surgery. Cresyl fast violet (CFV) staining was used to expose the thermal extent of laser surgery on cortical tissue. Eight tissue samples from each laser study group were processed for histological analysis and the mean ± standard deviation for thermal damage was reported. Thermal damage was quantified as ablation (thermally removed tissue), severe and mild coagulation (irreversible thermal damage) and edematous (reversible thermal damage) areas with regard to CFV stained slices. The Pearson correlation coefficient was calculated to test if the ablation efficiencies and total damage, and edematous areas were correlated to rates of temperature change.Results: No significant adverse effects were observed during surgeries. We found that both lasers investigated were successful in cortical tissue removal. Our results also revealed that irrespective of the mode of operation, laser wavelength and laser power, there is a strong correlation between the rates of temperature change and ablation efficiencies and a negative correlation between the rate of temperature change and total damage and edematous area.Conclusions: Both lasers investigated were successful in cortical tissue removal. We also reported that when the amount of energy delivered to the tissue was constant, the most important issue was to deliver this energy in a short time to achieve more efficient ablations with less edema around the lesion, regardless of mode of delivery (continuous or pulsed‐modulated mode), but further studies including the healing period after laser surgeries have to be performed to compare the thermal extent of damage comprehensively. Lasers Surg. Med.
- 8 October 2019
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 52 (3) , 235-246
The Comparison of Thermal Effects of a 1940‐nm Tm:fiber Laser and 980‐nm Diode Laser on Cortical Tissue: Stereotaxic Laser Brain Surgery
Background and Objectives: The thermal damage on adjacent healthy structures is always an unwanted consequence of continuous‐wave laser irradiation of soft tissues. To propose a laser as an effective alternative to traditional surgical tools, this photothermal damage due to heat conduction must be taken into account with a detailed laser dosimetry study. Two candidate lasers; a 980‐nm diode and 1940‐nm Tm:fiber were selected for this study. Despite the poor absorption by water, the 980‐nm diode laser has been one of the most widely used lasers in soft tissue surgeries due its good absorption by hemoglobin, which provides good homeostasis. The second laser; the Tm:fiber laser was selected due to its wavelength operating at an absorption peak of water (1,940 nm), which makes it a good candidate for ablation of biological tissues, and it is readily capable of being transmitted through flexible fiber optics to deliver energy to hard‐to‐reach regions. The underlying motivation for the research described in this paper is that with a comprehensive comparison of ablation capabilities and a detailed dose study of infrared lasers operating at different wavelengths and temperature monitoring of the tissue during laser surgery, it may be possible to specify the optimal laser parameters for laser surgery, and propose a treatment alternative to conventional surgical techniques in clinical use. The objectives of this study were to investigate and to compare the thermal effects of 980‐nm and 1940‐nm lasers on cortical tissue in vivo, to find the optimum parameters for laser‐brain‐ablation with minimum thermal damage to the surrounding healthy tissue, and finally, to analyze laser irradiated tissue thermographically and histologically to correlate thermal events and tissue damage with laser irradiation parameters.Study Design/Materials and Methods: Stereotaxic laser brain surgeries were performed on 32 male Wistar rats. A t‐type thermocouple was used to measure the temperature of the nearby tissue at a distance of 1 mm above and 1 mm away from the fiber tip during laser surgery. Cresyl fast violet (CFV) staining was used to expose the thermal extent of laser surgery on cortical tissue. Eight tissue samples from each laser study group were processed for histological analysis and the mean ± standard deviation for thermal damage was reported. Thermal damage was quantified as ablation (thermally removed tissue), severe and mild coagulation (irreversible thermal damage) and edematous (reversible thermal damage) areas with regard to CFV stained slices. The Pearson correlation coefficient was calculated to test if the ablation efficiencies and total damage, and edematous areas were correlated to rates of temperature change.Results: No significant adverse effects were observed during surgeries. We found that both lasers investigated were successful in cortical tissue removal. Our results also revealed that irrespective of the mode of operation, laser wavelength and laser power, there is a strong correlation between the rates of temperature change and ablation efficiencies and a negative correlation between the rate of temperature change and total damage and edematous area.Conclusions: Both lasers investigated were successful in cortical tissue removal. We also reported that when the amount of energy delivered to the tissue was constant, the most important issue was to deliver this energy in a short time to achieve more efficient ablations with less edema around the lesion, regardless of mode of delivery (continuous or pulsed‐modulated mode), but further studies including the healing period after laser surgeries have to be performed to compare the thermal extent of damage comprehensively. Lasers Surg. Med.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Bioimpedance Spectroscopy in Subjects with Auricular Vagus Nerve Stimulation
In this paper, single side body impedance spectroscopy is performed between wrist and ankle in response to auricular transcutaneous electrical vagus stimulation, to obtain the Cole parameters R o , R ∞ and f c . Following a resting period of 5 minutes in supine position, left ear vagus nerve was stimulated for 3 minutes and BIS performed every 10 seconds, on 8 healthy subjects with age: 23,6±1,5 years, height: 175±8,3 cm; weight: 69,5±18,7 kg and BMI: 22,6±5,5 kg/cm 2 . Cole circles moved to the right (inreased R o and R ∞ ) with stimulation while the centers shifted upwards. Intracellular and extracellular resistances and the capacitance C m all increased at the onset of vagus stimulation; resulting in a decrease of 3,4±1.33% in f c . Changes in R i mainly indicate water shift between cells and extracellular fluid; physiological changes occurred on cell membrane. f c independent of the participants’ anthropomorphic factors could be used as an indicator to vagus nerve stimulation, without further normalization. This preliminary study was realized with a limited number of participants; however, to reach statistically meaningful results measurements will be performed over a larger sample size.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Bioimpedance Spectroscopy in Subjects with Auricular Vagus Nerve Stimulation
In this paper, single side body impedance spectroscopy is performed between wrist and ankle in response to auricular transcutaneous electrical vagus stimulation, to obtain the Cole parameters R o , R ∞ and f c . Following a resting period of 5 minutes in supine position, left ear vagus nerve was stimulated for 3 minutes and BIS performed every 10 seconds, on 8 healthy subjects with age: 23,6±1,5 years, height: 175±8,3 cm; weight: 69,5±18,7 kg and BMI: 22,6±5,5 kg/cm 2 . Cole circles moved to the right (inreased R o and R ∞ ) with stimulation while the centers shifted upwards. Intracellular and extracellular resistances and the capacitance C m all increased at the onset of vagus stimulation; resulting in a decrease of 3,4±1.33% in f c . Changes in R i mainly indicate water shift between cells and extracellular fluid; physiological changes occurred on cell membrane. f c independent of the participants’ anthropomorphic factors could be used as an indicator to vagus nerve stimulation, without further normalization. This preliminary study was realized with a limited number of participants; however, to reach statistically meaningful results measurements will be performed over a larger sample size.
- 19 February 2019
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 51 (7) , 643-652
Stereotaxic laser brain surgery with 1940‐nm Tm:fiber laser: An in vivo study
Background: With exciting developments in fiber laser technology, studies investigating the use of lasers in neurosurgery have been increasing in the recent years. Fiber lasers are advantageous in many ways; first of all they are compact and they provide a more comfortable environment in the operating room due to feasibility of coupling laser light to different cross‐sectioned fibers. Thulium fiber (Tm:fiber) lasers have been under investigation for medical applications since 2005 due to their spectral proximity to the water absorption peak.Objectives: The primary aim of this study is to investigate the thermal effects of the 1940‐nm Tm:fiber laser on subcortical tissue and to examine the effects of laser parameters on laser‐induced lesions. Secondarily, it is also aimed to reveal the importance of temperature monitoring during laser surgeries by investigating the effects of temperature change on the characteristics of laser‐induced lesions.Materials and Methods: Stereotaxic laser brain surgery was performed on 20 male Wistar rats, in order to investigate the thermal effects of Tm:fiber laser. During surgeries temperature changes in the subcortical tissue were observed with a t‐type thermocouple for which a holder was designed to accomplish a 1 mm distance between the fiber tip and thermocouple tip. Histological examinations were performed on cresyl fast violet (CFV) stained slices under light microscopy. Photothermal effects of Tm:fiber laser on subcortical tissue were investigated in terms of ablated (removal of tissue), coagulated and edematous areas with a blinded micrograph evaluation. Relations between laser parameters, ablation efficiencies and rates of temperature changes were determined. Pearson's correlation coefficients between rates of temperature changes and ablation efficiencies, total laser damage and edematous area were calculated.Results: No significant adverse effects were observed during surgeries. Histological examinations revealed localized ablation surrounded by coagulation areas as well as edema. Ablation efficiencies ranged from 20% to 50% with changing laser parameters. The correlation coefficient between rates of temperature change and ablation efficiencies, total laser damage and edematous area were rather high.Conclusion: In this study we show that Tm:fiber lasers seem to be useful tools in brain surgeries especially to vaporize and coagulate the tissue. It is also shown that temperature monitoring during laser surgery is very crucial and gives information about laser‐induced lesion. Another take home message from this study is rather than the temperature increase, the rate of temperature change is more important. We found that if the temperature is changing in a short time interval, the extent of thermal damage can be minimized. Lasers Surg. Med.
- 19 February 2019
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 51 (7) , 643-652
Stereotaxic laser brain surgery with 1940‐nm Tm:fiber laser: An in vivo study
Background: With exciting developments in fiber laser technology, studies investigating the use of lasers in neurosurgery have been increasing in the recent years. Fiber lasers are advantageous in many ways; first of all they are compact and they provide a more comfortable environment in the operating room due to feasibility of coupling laser light to different cross‐sectioned fibers. Thulium fiber (Tm:fiber) lasers have been under investigation for medical applications since 2005 due to their spectral proximity to the water absorption peak.Objectives: The primary aim of this study is to investigate the thermal effects of the 1940‐nm Tm:fiber laser on subcortical tissue and to examine the effects of laser parameters on laser‐induced lesions. Secondarily, it is also aimed to reveal the importance of temperature monitoring during laser surgeries by investigating the effects of temperature change on the characteristics of laser‐induced lesions.Materials and Methods: Stereotaxic laser brain surgery was performed on 20 male Wistar rats, in order to investigate the thermal effects of Tm:fiber laser. During surgeries temperature changes in the subcortical tissue were observed with a t‐type thermocouple for which a holder was designed to accomplish a 1 mm distance between the fiber tip and thermocouple tip. Histological examinations were performed on cresyl fast violet (CFV) stained slices under light microscopy. Photothermal effects of Tm:fiber laser on subcortical tissue were investigated in terms of ablated (removal of tissue), coagulated and edematous areas with a blinded micrograph evaluation. Relations between laser parameters, ablation efficiencies and rates of temperature changes were determined. Pearson's correlation coefficients between rates of temperature changes and ablation efficiencies, total laser damage and edematous area were calculated.Results: No significant adverse effects were observed during surgeries. Histological examinations revealed localized ablation surrounded by coagulation areas as well as edema. Ablation efficiencies ranged from 20% to 50% with changing laser parameters. The correlation coefficient between rates of temperature change and ablation efficiencies, total laser damage and edematous area were rather high.Conclusion: In this study we show that Tm:fiber lasers seem to be useful tools in brain surgeries especially to vaporize and coagulate the tissue. It is also shown that temperature monitoring during laser surgery is very crucial and gives information about laser‐induced lesion. Another take home message from this study is rather than the temperature increase, the rate of temperature change is more important. We found that if the temperature is changing in a short time interval, the extent of thermal damage can be minimized. Lasers Surg. Med.
- 1 August 2014
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 43 (8) , 1015-1021
Investigating the ablation efficiency of a 1940-nm thulium fibre laser for intraoral surgery
- 1 August 2014
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 43 (8) , 1015-1021
Investigating the ablation efficiency of a 1940-nm thulium fibre laser for intraoral surgery
- 26 February 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 858408-858408-7
Incisional effects of 1940 nm thulium fiber laser on oral soft tissues
- 26 February 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 858408-858408-7
Incisional effects of 1940 nm thulium fiber laser on oral soft tissues
- 26 February 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 858407-858407-6
Determination of the ablation efficiencies of the laser irradiated tissues via rate of temperature change over time
- 26 February 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 858407-858407-6
Determination of the ablation efficiencies of the laser irradiated tissues via rate of temperature change over time
- 15 January 2013
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 45 (1) , 48-56
Tm:Fiber laser ablation with real‐time temperature monitoring for minimizing collateral thermal damage: ex vivo dosimetry for ovine brain
Background and Objective The thermal damage of the surrounding tissue can be an unwanted result of continuous-wave laser irradiations. In order to propose an effective alternative to conventional surgical techniques, photothermal damage must be taken under control by a detailed dose study. Real-time temperature monitoring can be also an effective way to get rid of these negative effects. The aim of the present study is to investigate the potential of a new laser-thermoprobe, which consists of a continuous-wave 1,940-nm Tm:fiber laser and a thermocouple measurement system for brain surgery in an ex vivo study. Study Design/Materials and Methods A laser-thermoprobe was designed for using the near-by tissue temperature as a real-time reference for the applicator. Fresh lamb brain tissues were used for experiments. 320 laser shots were performed on both cortical and subcortical tissue. Results The relationship between laser parameters, temperature changes, and ablation (removal of tissue) efficiency was determined. The correlation between rate of temperature change and ablation efficiency was calculated. Conclusion Laser-thermoprobe leads us to understand the basic laser–tissue interaction mechanism in a very cheap and easy way, without making a change in the experimental design. It was also shown that the ablation and coagulation (thermally irreversible damage) diameters could be predicted, and carbonization can be avoided by temperature monitoring. Lasers Surg. Med. 45: 48–56, 2013.
- 15 January 2013
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 45 (1) , 48-56
Tm:Fiber laser ablation with real‐time temperature monitoring for minimizing collateral thermal damage: ex vivo dosimetry for ovine brain
Background and Objective The thermal damage of the surrounding tissue can be an unwanted result of continuous-wave laser irradiations. In order to propose an effective alternative to conventional surgical techniques, photothermal damage must be taken under control by a detailed dose study. Real-time temperature monitoring can be also an effective way to get rid of these negative effects. The aim of the present study is to investigate the potential of a new laser-thermoprobe, which consists of a continuous-wave 1,940-nm Tm:fiber laser and a thermocouple measurement system for brain surgery in an ex vivo study. Study Design/Materials and Methods A laser-thermoprobe was designed for using the near-by tissue temperature as a real-time reference for the applicator. Fresh lamb brain tissues were used for experiments. 320 laser shots were performed on both cortical and subcortical tissue. Results The relationship between laser parameters, temperature changes, and ablation (removal of tissue) efficiency was determined. The correlation between rate of temperature change and ablation efficiency was calculated. Conclusion Laser-thermoprobe leads us to understand the basic laser–tissue interaction mechanism in a very cheap and easy way, without making a change in the experimental design. It was also shown that the ablation and coagulation (thermally irreversible damage) diameters could be predicted, and carbonization can be avoided by temperature monitoring. Lasers Surg. Med. 45: 48–56, 2013.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- p. 82210E-82210E-7
Temperature measurement during laser brain ablation by thulium fiber laser
The aim of the study was to find a relationship between laser power, exposure time, ablation efficiency and temperature increase during laser brain ablation by Thulium fiber laser. The thermal effects of the 1940-nm Tm-fiber laser on the brain tissue was also investigated in terms of ablation efficiency. These experiments are very important in order to model temperature increase-ablation efficiency during lasing with different power and exposure time. 4-5 mm coronal sections were taken from lamb brains. Laser was applied at cortical and subcortical tissue with 0-0.1 mm distance, in both continuous and pulsed modes with 400 mW and 600 mW which were chosen by a predosimetric study. In continuous and pulse mode doses were changed with exposure time and on-off cycle respectively, in order to achive the tissue to absorb same energy. During lasing temperature increases were recorded by a thermoprobe (thermoprobe is a system which a 300 micrometer fiber was embedded into a thermocouple). The radius of ablation and coagulation for each laser application was recorded by a microscope. By calculating ablation efficiency (100xablation/calculation radius) the appropriate laser doses were determined for both cortical and subcortical tissue. The maximum ablation efficiency for cortical and subcortical tissue in both continous and pulsed mode was found for 600 mW. Ablation efficiencies for continuous mode was superior than the pulsed mode for all laser doses which were studied. Temperature increases showed a significant differences for continuous and pulse mode operating systems and effect the ablation efficiencies.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- p. 82210E-82210E-7
Temperature measurement during laser brain ablation by thulium fiber laser
The aim of the study was to find a relationship between laser power, exposure time, ablation efficiency and temperature increase during laser brain ablation by Thulium fiber laser. The thermal effects of the 1940-nm Tm-fiber laser on the brain tissue was also investigated in terms of ablation efficiency. These experiments are very important in order to model temperature increase-ablation efficiency during lasing with different power and exposure time. 4-5 mm coronal sections were taken from lamb brains. Laser was applied at cortical and subcortical tissue with 0-0.1 mm distance, in both continuous and pulsed modes with 400 mW and 600 mW which were chosen by a predosimetric study. In continuous and pulse mode doses were changed with exposure time and on-off cycle respectively, in order to achive the tissue to absorb same energy. During lasing temperature increases were recorded by a thermoprobe (thermoprobe is a system which a 300 micrometer fiber was embedded into a thermocouple). The radius of ablation and coagulation for each laser application was recorded by a microscope. By calculating ablation efficiency (100xablation/calculation radius) the appropriate laser doses were determined for both cortical and subcortical tissue. The maximum ablation efficiency for cortical and subcortical tissue in both continous and pulsed mode was found for 600 mW. Ablation efficiencies for continuous mode was superior than the pulsed mode for all laser doses which were studied. Temperature increases showed a significant differences for continuous and pulse mode operating systems and effect the ablation efficiencies.