Orhan İçElli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Orhan İçElli has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Ozan Toker
8 shared publicationsÖzgür Akçalı
5 shared publications- Bayram Bilmez
SAMSUN UNIVERSITY, FACULTY OF ENGINEERING
2 shared publications H. Birtan Kavanoz
2 shared publicationsM. Okutan
Department of Physics, Faculty of Science and Letters, Yildiz Technical University, Istanbul, Turkey
2 shared publicationsYaşar Karabul
Department of Physics, Science and Art Faculty, Yıldız Technical University, İstanbul, Turkey
2 shared publications
Latest Publications
- Open Access
- 29 January 2026
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 4 (1) , 025410055
Evaluation of inter-fractional tumor target volume changes in ViewRay MRIdian LINAC adaptive radiotherapy using similarity metrics
Tumor geometry can change during radiotherapy, and interfractional anatomical variations may compromise target coverage and dose conformity if not properly addressed. Magnetic resonance–guided adaptive radiotherapy (MRgART) enables ongoing visualization of tumor morphology and provides a framework for individualized treatment adaptation. This study quantitatively evaluated interfractional gross tumor volume (GTV) changes in patients treated with a ViewRay MRIdian LINAC system and investigated which similarity metric most reliably characterizes these variations. Retrospective MR images from 37 patients were analyzed and grouped by anatomical region into the pelvis, abdomen, and thorax. Baseline GTV (GTV₀) was compared with GTVs from five consecutive fractions (GTV₁–GTV₅). Geometric agreement was assessed using four similarity metrics: Dice similarity coefficient (DSC), Jaccard similarity coefficient (JSC), Tanimoto similarity coefficient (TSC), and Ochiai similarity coefficient (OSC). Interfractional stability was evaluated using mean similarity values and standard deviations across fractions. The abdominal region exhibited the greatest interfractional variability, with marked volume changes observed particularly in pancreatic cancer patients. Pelvic and thoracic tumors demonstrated relatively greater geometric stability, with lung tumors showing comparatively consistent agreement across fractions. Across all anatomical regions, OSC showed the highest mean similarity values and the lowest variability, indicating greater robustness than the other metrics. Statistical analysis confirmed that OSC performed significantly better than DSC, JSC, and TSC in the pelvis and abdomen (p<0.05), while showing comparable behavior to DSC in the thorax. These findings indicate that OSC is a reliable metric for monitoring interfractional tumor geometry in MR-guided adaptive radiotherapy and may support more precise and efficient adaptive treatment strategies.
- 29 January 2026
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 4 (1) , 025410055
Open AccessEvaluation of inter-fractional tumor target volume changes in ViewRay MRIdian LINAC adaptive radiotherapy using similarity metrics
Tumor geometry can change during radiotherapy, and interfractional anatomical variations may compromise target coverage and dose conformity if not properly addressed. Magnetic resonance–guided adaptive radiotherapy (MRgART) enables ongoing visualization of tumor morphology and provides a framework for individualized treatment adaptation. This study quantitatively evaluated interfractional gross tumor volume (GTV) changes in patients treated with a ViewRay MRIdian LINAC system and investigated which similarity metric most reliably characterizes these variations. Retrospective MR images from 37 patients were analyzed and grouped by anatomical region into the pelvis, abdomen, and thorax. Baseline GTV (GTV₀) was compared with GTVs from five consecutive fractions (GTV₁–GTV₅). Geometric agreement was assessed using four similarity metrics: Dice similarity coefficient (DSC), Jaccard similarity coefficient (JSC), Tanimoto similarity coefficient (TSC), and Ochiai similarity coefficient (OSC). Interfractional stability was evaluated using mean similarity values and standard deviations across fractions. The abdominal region exhibited the greatest interfractional variability, with marked volume changes observed particularly in pancreatic cancer patients. Pelvic and thoracic tumors demonstrated relatively greater geometric stability, with lung tumors showing comparatively consistent agreement across fractions. Across all anatomical regions, OSC showed the highest mean similarity values and the lowest variability, indicating greater robustness than the other metrics. Statistical analysis confirmed that OSC performed significantly better than DSC, JSC, and TSC in the pelvis and abdomen (p<0.05), while showing comparable behavior to DSC in the thorax. These findings indicate that OSC is a reliable metric for monitoring interfractional tumor geometry in MR-guided adaptive radiotherapy and may support more precise and efficient adaptive treatment strategies.
- 6 January 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 242
Quantitative assessment of beta radiation shielding in medical polymers based on Monte Carlo simulations
- 6 January 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 242
Quantitative assessment of beta radiation shielding in medical polymers based on Monte Carlo simulations
- 3 December 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 229, 112358
Comparative Monte Carlo study of transparent protective layers for beta radiation attenuation in betavoltaic applications
- 3 December 2025
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 229, 112358
Comparative Monte Carlo study of transparent protective layers for beta radiation attenuation in betavoltaic applications
- Open Access
- 1 January 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 54 (1) , 310-317
A comparative study on applicability and efficiency of machine learning algorithms for modeling gamma-ray shielding behaviors
- 1 January 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 54 (1) , 310-317
Open AccessA comparative study on applicability and efficiency of machine learning algorithms for modeling gamma-ray shielding behaviors
- 22 July 2021
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 139, 103892
Efficiency analysis of multiple detector effects on MCNP 6.2 simulations
- 22 July 2021
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 139, 103892
Efficiency analysis of multiple detector effects on MCNP 6.2 simulations
- 19 March 2020
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 59 (2) , 283-293
Comparison of ITO and ZnO ternary glassy composites in terms of radiation shielding properties by Monte Carlo N-particle transport code and BXCOM
In the present study, radiation shielding properties of two glassy composite materials that are widely used in electronics, photovoltaic applications, and sensor technology, were investigated in the photon energy range from 15 keV to 15 MeV. The materials chosen were (ITO)/V2O5/B2O3 and ZnO/V2O5/B2O3 including various concentrations of B2O3. Radiation interaction was simulated and shielding parameters calculated by means of the MCNP and BXCOM codes. More specifically, buildup factors, effective electron density (\(N_{\text{eff}}\)) and effective atomic number (\(Z_{\text{eff}}\)) were calculated with BXCOM, while mass attenuation coefficients (\(\mu /\rho\)), half-value layer (HVL) and tenth-value layer (TVL) values were calculated with MCNP. The results were compared with those obtained with the WinXCOM code, for validation. Acceptable and preferable results were obtained for both composites as alternative to other glassy shielding materials. The composite including ITO showed better shielding properties than the composite including ZnO. In terms of radiation shielding, both composites turned out to be better than concrete and close to lead.- 19 March 2020
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 59 (2) , 283-293
Comparison of ITO and ZnO ternary glassy composites in terms of radiation shielding properties by Monte Carlo N-particle transport code and BXCOM
In the present study, radiation shielding properties of two glassy composite materials that are widely used in electronics, photovoltaic applications, and sensor technology, were investigated in the photon energy range from 15 keV to 15 MeV. The materials chosen were (ITO)/V2O5/B2O3 and ZnO/V2O5/B2O3 including various concentrations of B2O3. Radiation interaction was simulated and shielding parameters calculated by means of the MCNP and BXCOM codes. More specifically, buildup factors, effective electron density (\(N_{\text{eff}}\)) and effective atomic number (\(Z_{\text{eff}}\)) were calculated with BXCOM, while mass attenuation coefficients (\(\mu /\rho\)), half-value layer (HVL) and tenth-value layer (TVL) values were calculated with MCNP. The results were compared with those obtained with the WinXCOM code, for validation. Acceptable and preferable results were obtained for both composites as alternative to other glassy shielding materials. The composite including ITO showed better shielding properties than the composite including ZnO. In terms of radiation shielding, both composites turned out to be better than concrete and close to lead.- 24 April 2019
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 174 (5-6) , 506-518
BXCOM: a software for computation of radiation sensing
The main objective of this work is to develop user-friendly software, called BXCOM, for computation of the exposure build-up factor (EBF) and the energy absorption build-up factor (EABF), using geometric progression (G-P) fitting method for element, compound or mixture in the energy region 0.015–15 MeV, and for penetration depths up to 40 mean free path (mfp). Furthermore, BXCOM can generate the equivalent atomic number and five fitting parameters used in the G-P method for mixtures and compounds over an interval of photon energies extended from 0.015 to 15 MeV. In addition, the program is designed to calculate the effective atomic number and effective electron number via the direct method. BXCOM program has been verified by comparing its results with approved data by American National Standards Institute. BXCOM runs under MS Windows® operating system. It has an improved user interface that provides examination of material's radiation interaction parameters. Finally, BXCOM allows rapid and reliable calculation of many γ-ray interaction parameters such as , , , G-P fitting parameters and build-up factors that are essential in a wide range of applications such as radiation shielding, radiotherapy, technology and so on.- 24 April 2019
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 174 (5-6) , 506-518
BXCOM: a software for computation of radiation sensing
The main objective of this work is to develop user-friendly software, called BXCOM, for computation of the exposure build-up factor (EBF) and the energy absorption build-up factor (EABF), using geometric progression (G-P) fitting method for element, compound or mixture in the energy region 0.015–15 MeV, and for penetration depths up to 40 mean free path (mfp). Furthermore, BXCOM can generate the equivalent atomic number and five fitting parameters used in the G-P method for mixtures and compounds over an interval of photon energies extended from 0.015 to 15 MeV. In addition, the program is designed to calculate the effective atomic number and effective electron number via the direct method. BXCOM program has been verified by comparing its results with approved data by American National Standards Institute. BXCOM runs under MS Windows® operating system. It has an improved user interface that provides examination of material's radiation interaction parameters. Finally, BXCOM allows rapid and reliable calculation of many γ-ray interaction parameters such as , , , G-P fitting parameters and build-up factors that are essential in a wide range of applications such as radiation shielding, radiotherapy, technology and so on.- 31 May 2018
- Published by Springer Nature in BioMetals
- Vol. 31 (4) , 673-678
Correlation between Na/K ratio and electron densities in blood samples of breast cancer patients
The main purpose of this study was to investigate the relationship between the electron densities and Na/K ratio which has important role in breast cancer disease. Determinations of sodium and potassium concentrations in blood samples performed with inductive coupled plasma-atomic emission spectrometry. Electron density values of blood samples were determined via ZXCOM. Statistical analyses were performed for electron densities and Na/K ratio including Kolmogorov–Smirnov normality tests, Spearman’s rank correlation test and Mann–Whitney U test. It was found that the electron densities significantly differ between control and breast cancer groups. In addition, statistically significant positive correlation was found between the electron density and Na/K ratios in breast cancer group.
- 31 May 2018
- Published by Springer Nature in BioMetals
- Vol. 31 (4) , 673-678
Correlation between Na/K ratio and electron densities in blood samples of breast cancer patients
The main purpose of this study was to investigate the relationship between the electron densities and Na/K ratio which has important role in breast cancer disease. Determinations of sodium and potassium concentrations in blood samples performed with inductive coupled plasma-atomic emission spectrometry. Electron density values of blood samples were determined via ZXCOM. Statistical analyses were performed for electron densities and Na/K ratio including Kolmogorov–Smirnov normality tests, Spearman’s rank correlation test and Mann–Whitney U test. It was found that the electron densities significantly differ between control and breast cancer groups. In addition, statistically significant positive correlation was found between the electron density and Na/K ratios in breast cancer group.
- 7 November 2017
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 172 (11-12) , 805-814
Investigating the performance of P3HT:PCBM organic solar cells involving gamma-irradiated PEDOT:PSS layer
In this work, we investigated for the first time the characteristics of (poly (3-hexylthiopene) and [6, 6]-phenyl C61-butyric acid methyl ester) (P3HT:PCBM) blends-based organic solar cell with 1.25 mg/mL boric-acid (H3BO3)-doped poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) layer which is irradiated under the 40 Gray (Gy) dose of gamma (γ) ray. Experimental results showed that the parameters of solar cell improved with exposure to low-dose gamma radiation. In particular, it has provided a significant improvement in short-circuit current density (Jsc) and power conversion efficiency (PCE). About 49% increase in PCE to 1.22% and 40% increase in Jsc to 6.28 mA/cm2 was obtained between the bare device and the device containing irradiated PEDOT:PSS:H3BO3. Also, it was determined that the H3BO3-doped PEDOT:PSS is more stable to temperature. More importantly, solar cell containing gamma-irradiated PEDOT:PSS:H3BO3 showed best performance comparing to conventional PEDOT:PSS-based cell.
- 7 November 2017
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 172 (11-12) , 805-814
Investigating the performance of P3HT:PCBM organic solar cells involving gamma-irradiated PEDOT:PSS layer
In this work, we investigated for the first time the characteristics of (poly (3-hexylthiopene) and [6, 6]-phenyl C61-butyric acid methyl ester) (P3HT:PCBM) blends-based organic solar cell with 1.25 mg/mL boric-acid (H3BO3)-doped poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) layer which is irradiated under the 40 Gray (Gy) dose of gamma (γ) ray. Experimental results showed that the parameters of solar cell improved with exposure to low-dose gamma radiation. In particular, it has provided a significant improvement in short-circuit current density (Jsc) and power conversion efficiency (PCE). About 49% increase in PCE to 1.22% and 40% increase in Jsc to 6.28 mA/cm2 was obtained between the bare device and the device containing irradiated PEDOT:PSS:H3BO3. Also, it was determined that the H3BO3-doped PEDOT:PSS is more stable to temperature. More importantly, solar cell containing gamma-irradiated PEDOT:PSS:H3BO3 showed best performance comparing to conventional PEDOT:PSS-based cell.