Uday Chand Ghosh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Uday Chand Ghosh has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Biswaranjan Manna
Department of Chemistry, Presidency College, 86/1, College Street, Kolkata 700073, West Bengal, India
3 shared publicationsSoumen Dey
Presidency College
2 shared publications- Sushanta Debnath
Department of Applied Chemistry, University of Johannesburg, Johannesburg, South Africa
2 shared publications Biswa Ranjan Manna
Department of Chemistry, Presidency College, Kolkata - 700073, West Bengal, India
1 shared publicationDurjoy Bandhoyapadhyay
Presidency College
1 shared publicationDurjoy Bandyopadhyay
Department of Chemistry, Presidency College, 86/1, College Street, Kolkata 700073, West Bengal, India
1 shared publication
Latest Publications
- 1 February 2007
- Published by Springer Nature in Adsorption
- Vol. 13 (1) , 83-94
Adsorption kinetics of fluoride on iron(III)-zirconium(IV) hybrid oxide
- 1 February 2007
- Published by Springer Nature in Adsorption
- Vol. 13 (1) , 83-94
Adsorption kinetics of fluoride on iron(III)-zirconium(IV) hybrid oxide
- 1 May 2006
- Published by IWA Publishing in Water Quality Research Journal
- Vol. 41 (2) , 198-209
Hydrous Iron(III)-Tin(IV) Binary Mixed Oxide: Arsenic Adsorption Behaviour from Aqueous Solution
Groundwater in the Bengal delta plain is primarily in an anoxic environment and As(III)/As(total) ratios reported are in the range of 0.60 to 0.90. Most of the studied adsorbents showed greater adsorption affinity for less toxic As(V) than for more toxic As(III). The synthesis and physicochemical characterizations of iron(III)-tin(IV) binary mixed oxide composite with systematic arsenic adsorption behaviour are reported here. The parameters studied are the effect of pH, adsorption capacity with varying arsenic loads, contact time for kinetics and isotherm modelling by batch method. In the pH range of 3.0 to 9.0, the adsorption of As(III) is found to be nearly the same while that of As(V) decreases with increasing pH for the studied arsenic concentrations (5.0 to 20.0 mg L-1). The adsorption data were analyzed using various kinetic and isotherm model equations. The rate of adsorption of As(III) was faster than that of As(V) at equilibrium pH ~7.0 and temperature 30(± 2)°C. The adsorption kinetic data for arsenic fitted best with the Ho9s pseudo-second order [R2 ~0.99–1.00 for As(III) and ~0.97–0.98 for As(V)] and parabolic diffusion (R2 ~0.98–0.99) equations. The present kinetic data fitted the power function and simple Elovich kinetic equations well (R2 = ~0.97–1.00), except the data obtained for As(III) from the 20.0 mg L-1 solution. The analyses of adsorption data for As(III) and As(V), respectively, at equilibrium pH 6.8(±0.1) and 7.3(±0.1) with three different two-parameter isotherm model equations show the fitting order: Langmuir < Freundlich >Temkin. The monolayer adsorption capacity (θ0, mg g-1) values evaluated from the Langmuir isotherm for As(III) and As(V) are 43.86 and 27.55, respectively.
- 1 May 2006
- Published by IWA Publishing in Water Quality Research Journal
- Vol. 41 (2) , 198-209
Hydrous Iron(III)-Tin(IV) Binary Mixed Oxide: Arsenic Adsorption Behaviour from Aqueous Solution
Groundwater in the Bengal delta plain is primarily in an anoxic environment and As(III)/As(total) ratios reported are in the range of 0.60 to 0.90. Most of the studied adsorbents showed greater adsorption affinity for less toxic As(V) than for more toxic As(III). The synthesis and physicochemical characterizations of iron(III)-tin(IV) binary mixed oxide composite with systematic arsenic adsorption behaviour are reported here. The parameters studied are the effect of pH, adsorption capacity with varying arsenic loads, contact time for kinetics and isotherm modelling by batch method. In the pH range of 3.0 to 9.0, the adsorption of As(III) is found to be nearly the same while that of As(V) decreases with increasing pH for the studied arsenic concentrations (5.0 to 20.0 mg L-1). The adsorption data were analyzed using various kinetic and isotherm model equations. The rate of adsorption of As(III) was faster than that of As(V) at equilibrium pH ~7.0 and temperature 30(± 2)°C. The adsorption kinetic data for arsenic fitted best with the Ho9s pseudo-second order [R2 ~0.99–1.00 for As(III) and ~0.97–0.98 for As(V)] and parabolic diffusion (R2 ~0.98–0.99) equations. The present kinetic data fitted the power function and simple Elovich kinetic equations well (R2 = ~0.97–1.00), except the data obtained for As(III) from the 20.0 mg L-1 solution. The analyses of adsorption data for As(III) and As(V), respectively, at equilibrium pH 6.8(±0.1) and 7.3(±0.1) with three different two-parameter isotherm model equations show the fitting order: Langmuir < Freundlich >Temkin. The monolayer adsorption capacity (θ0, mg g-1) values evaluated from the Langmuir isotherm for As(III) and As(V) are 43.86 and 27.55, respectively.
- 1 February 2005
- Published by IWA Publishing in Water Quality Research Journal
- Vol. 40 (1) , 82-90
Pilot-Scale Performance of Iron and Arsenic Removal from Contaminated Groundwater
Pilot-scale performance in reducing excess iron and arsenic from contaminated groundwater has been systematically reported. Here, a double column unit, the first packed with β-MnO2 and the second with crystalline FeOOH (goethite variety), with filters attached to the outlet of hand-pump tube-wells has been used in the field. Results showed that the filters generate 10,000 to 15,000 BV and 19,000 to 35,000 BV water with iron ≤ 0.3 mg/L and arsenic ≤10 µg/L from groundwater having influent iron and arsenic levels of 3.75 to 7.25 mg/L and 70 to 220 µg/L, respectively. The downflow rate of effluent water was 237.6 to 305.5 L/m2-min. The performance results were achieved with a single charging of the iron and arsenic removal media. Toxicity characteristic leaching procedure (TCLP) tests of the waste (arsenic content: 2.4 g/kg) showed that it is not hazardous to the environment and does not pose any risk to users. Cost evaluation showed $US0.50 to 0.70 per 1000 gallons of treated water and, hence, the technology is cost-effective for countries such as India and Bangladesh.
- 1 February 2005
- Published by IWA Publishing in Water Quality Research Journal
- Vol. 40 (1) , 82-90
Pilot-Scale Performance of Iron and Arsenic Removal from Contaminated Groundwater
Pilot-scale performance in reducing excess iron and arsenic from contaminated groundwater has been systematically reported. Here, a double column unit, the first packed with β-MnO2 and the second with crystalline FeOOH (goethite variety), with filters attached to the outlet of hand-pump tube-wells has been used in the field. Results showed that the filters generate 10,000 to 15,000 BV and 19,000 to 35,000 BV water with iron ≤ 0.3 mg/L and arsenic ≤10 µg/L from groundwater having influent iron and arsenic levels of 3.75 to 7.25 mg/L and 70 to 220 µg/L, respectively. The downflow rate of effluent water was 237.6 to 305.5 L/m2-min. The performance results were achieved with a single charging of the iron and arsenic removal media. Toxicity characteristic leaching procedure (TCLP) tests of the waste (arsenic content: 2.4 g/kg) showed that it is not hazardous to the environment and does not pose any risk to users. Cost evaluation showed $US0.50 to 0.70 per 1000 gallons of treated water and, hence, the technology is cost-effective for countries such as India and Bangladesh.
- 1 November 2004
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 53 (7) , 483-495
Crystalline hydrous titanium (IV) oxide (CHTO): An arsenic (III) scavenger from natural water
Arsenic contamination (>10 ppb) in groundwater poses a risk to public health globally. The problem is apparently the greatest in the Bengal basin of the Ganga River. As(III) is a major contaminant in anoxic groundwater. Here, a systematic report on As(III) removal using synthetic crystalline hydrous titanium(IV) oxide (CHTO) is made. Absolute As(III) sorption capacity is 72 to 75 g kg−1 at a pH of 7.0. CHTO has nearly the same sorption density in the pH range of 6.0 to 9.0. Use of pre-dried CHTO above 350°C shows a decrease in sorption density from 11.50 (±0.10) to −1. Approximately 70% of As(III) sorption takes place within 0.5 hour. Interfering effect studies of some ions show a poor effect on the sorption process except for HCO−3. As(III) sorption follows the Lagergren first-order kinetic model and the sorption data fit the Freundlich and Langmuir isotherms well. Batch and column methods for regeneration of arsenic rich CHTO with 1.0 M NaOH solution show ∼90% and 75 to 80% regain of its initial efficiency, respectively. Flow-rate and bed depth variation effects on As(III) removal from a spiked (500 µg l−1) natural water are reported systematically. Lab-bench mini-pilot scale application of a fixed-bed (bed volume=30.0 cm3) CHTO column is reported at a down flow-rate of 33 to 34 B.V. (bed volume) h−1 using an As(III) spiked (320 µg l−1) natural tap water sample from Presidency College, Kolkata. Reuse of the bed after regeneration shows a decrease in As(III) removal efficiency to the extent of 20–25% of that of a fresh column. Arsenic recovery (∼99.25%) from the regenerate is also reported.
- 1 November 2004
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 53 (7) , 483-495
Crystalline hydrous titanium (IV) oxide (CHTO): An arsenic (III) scavenger from natural water
Arsenic contamination (>10 ppb) in groundwater poses a risk to public health globally. The problem is apparently the greatest in the Bengal basin of the Ganga River. As(III) is a major contaminant in anoxic groundwater. Here, a systematic report on As(III) removal using synthetic crystalline hydrous titanium(IV) oxide (CHTO) is made. Absolute As(III) sorption capacity is 72 to 75 g kg−1 at a pH of 7.0. CHTO has nearly the same sorption density in the pH range of 6.0 to 9.0. Use of pre-dried CHTO above 350°C shows a decrease in sorption density from 11.50 (±0.10) to −1. Approximately 70% of As(III) sorption takes place within 0.5 hour. Interfering effect studies of some ions show a poor effect on the sorption process except for HCO−3. As(III) sorption follows the Lagergren first-order kinetic model and the sorption data fit the Freundlich and Langmuir isotherms well. Batch and column methods for regeneration of arsenic rich CHTO with 1.0 M NaOH solution show ∼90% and 75 to 80% regain of its initial efficiency, respectively. Flow-rate and bed depth variation effects on As(III) removal from a spiked (500 µg l−1) natural water are reported systematically. Lab-bench mini-pilot scale application of a fixed-bed (bed volume=30.0 cm3) CHTO column is reported at a down flow-rate of 33 to 34 B.V. (bed volume) h−1 using an As(III) spiked (320 µg l−1) natural tap water sample from Presidency College, Kolkata. Reuse of the bed after regeneration shows a decrease in As(III) removal efficiency to the extent of 20–25% of that of a fresh column. Arsenic recovery (∼99.25%) from the regenerate is also reported.
- 1 October 2004
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 158 (1) , 311-323
Hydrous Ferric Oxide (HFO)—a Scavenger for Fluoride from Contaminated Water
- 1 October 2004
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 158 (1) , 311-323
Hydrous Ferric Oxide (HFO)—a Scavenger for Fluoride from Contaminated Water
- 1 February 2003
- Published by IWA Publishing in Water Quality Research Journal
- Vol. 38 (1) , 193-210
Removal of Arsenic from Groundwater using Crystalline Hydrous Ferric Oxide (CHFO)
Synthesis of crystalline hydrous ferric oxide (CHFO), a modified iron-based adsorbent, and its arsenic sorption behaviour have been reported. Here, the effects of pH with variation of arsenic concentrations, contact time, pre-drying of CHFO, competition of some other anions and regeneration of arsenicsaturated CHFO are conducted by batch method. The sorption of As(V) is highly dependent on the concentration and pH of the experimental system, while that for As(III) is pH insensitive. As(III) is found to require less contact time to attain equilibrium than that of arsenic(V). Pre-drying of CHFO in the temperature range of 200 to 300°C is found to be effective in removing both As(III) and As(V). Adsorption kinetics follow the first-order Lagergren model. The equilibrium data conform to the Langmuir isotherm. Evaluated Langmuir constants and equilibrium parameter (RL) indicate that CHFO is a better As(III) adsorbent under experimental conditions. Sulphate, phosphate and bicarbonate compete poorly with As(III) sorption. A field test using CHFO-packed fixed-bed column is reported. Effluent water bed volumes of 14,000, 11,000 and 9000 BV (arsenic ≤ 0.01 mg L-1) were obtained in the first, second and third cycle of operation from a groundwater sample (arsenic content: 320.400 μg L-1). Regeneration of the exhausted column was achieved with up to 80 to 85% efficiency using 3 BV of 5 M NaOH solution recycled through the column five times. Arsenic was recovered as As2S3 from the regenerates, to avoid recycling of arsenic into the environment.
- 1 February 2003
- Published by IWA Publishing in Water Quality Research Journal
- Vol. 38 (1) , 193-210
Removal of Arsenic from Groundwater using Crystalline Hydrous Ferric Oxide (CHFO)
Synthesis of crystalline hydrous ferric oxide (CHFO), a modified iron-based adsorbent, and its arsenic sorption behaviour have been reported. Here, the effects of pH with variation of arsenic concentrations, contact time, pre-drying of CHFO, competition of some other anions and regeneration of arsenicsaturated CHFO are conducted by batch method. The sorption of As(V) is highly dependent on the concentration and pH of the experimental system, while that for As(III) is pH insensitive. As(III) is found to require less contact time to attain equilibrium than that of arsenic(V). Pre-drying of CHFO in the temperature range of 200 to 300°C is found to be effective in removing both As(III) and As(V). Adsorption kinetics follow the first-order Lagergren model. The equilibrium data conform to the Langmuir isotherm. Evaluated Langmuir constants and equilibrium parameter (RL) indicate that CHFO is a better As(III) adsorbent under experimental conditions. Sulphate, phosphate and bicarbonate compete poorly with As(III) sorption. A field test using CHFO-packed fixed-bed column is reported. Effluent water bed volumes of 14,000, 11,000 and 9000 BV (arsenic ≤ 0.01 mg L-1) were obtained in the first, second and third cycle of operation from a groundwater sample (arsenic content: 320.400 μg L-1). Regeneration of the exhausted column was achieved with up to 80 to 85% efficiency using 3 BV of 5 M NaOH solution recycled through the column five times. Arsenic was recovered as As2S3 from the regenerates, to avoid recycling of arsenic into the environment.
- 1 February 2003
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 143 (1-4) , 245-256
Studies on Management of Chromium(VI) – Contaminated Industrial Waste Effluent using Hydrous Titanium Oxide (HTO)
- 1 February 2003
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 143 (1-4) , 245-256
Studies on Management of Chromium(VI) – Contaminated Industrial Waste Effluent using Hydrous Titanium Oxide (HTO)