EJEun Young Jeong

Eun Young Jeong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eun Young Jeong has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Intraocular Pressure Measurement Technique Based on Acoustic Radiation Force Using an Ultrasound Transducer: A Feasibility Study

    by Hee Su Lee, Eun Young Jeong, Jin Ho Sung, Bo Eun Choi, Jong Seob Jeong

    High intraocular pressure (IOP) is one of the major risk factors for glaucoma, and thus accurate IOP measurements should be performed to diagnose and treat glaucoma early. In this study, a novel technique for measuring the IOP based on acoustic radiation force was proposed, and its potential was experimentally demonstrated. The proposed technique uses the acoustic radiation force to generate axial displacement on the ocular surface while simultaneously measuring the degree of deformation. In order to verify that the ocular displacement induced by the acoustic radiation force is related to the IOP, the experiment was conducted by fabricating a 5 MHz single element transducer and gelatin phantoms with different stiffness values. Our experimental results show that there is a close relationship between the ocular displacement by the acoustic radiation force and the IOP obtained by a commercial tonometer. Therefore, the proposed acoustic radiation force technique can be a promising candidate for measuring the IOP.


  • Open Access

    Interleaved Array Transducer with Polarization Inversion Technique to Implement Ultrasound Tissue Harmonic Imaging

    by Chan Yuk Park, Jin Ho Sung, Eun Young Jeong, Hee Su Lee, Jong Seob Jeong

    In ultrasound tissue harmonic imaging (THI), it is preferred that the bandwidth of the array transducer covers at least the fundamental frequency f0 for transmission and the second harmonic frequency 2f0 for reception. However, it is challenging to develop an array transducer with a broad bandwidth due to the single resonance characteristics of piezoelectric materials. In this study, we present an improved interleaved array transducer suitable for THI and a dedicated transducer fabrication scheme. The proposed array transducer has a novel structure in which conventional elements exhibiting f0 resonant frequency and polarization-inverted elements exhibiting 2f0 resonant frequency are alternately located, and the thicknesses of all piezoelectric elements are identical. The performance of the proposed method was demonstrated by finite element analysis (FEA) simulations and experiments using a fabricated prototype array transducer. Using the proposed technique, f0 and 2f0 frequency ultrasounds can be efficiently transmitted and received, respectively, resulting in a 90% broad bandwidth feature of the transducer. Thus, the proposed technique can be one of the potential ways to implement high resolution THI.


  • Intravascular Ultrasound Transducer by Using Polarization Inversion Technique for Tissue Harmonic Imaging: Modeling and Experiments

    by Jin Ho Sung, Eun Young Jeong, Jong Seob Jeong

    Intravascular ultrasound (IVUS) tissue harmonic imaging (THI) is one of the useful vessel imaging techniques that can provide deep penetration depth as well as high spatial and contrast resolution. Typically, a high-frequency IVUS transducer for THI requires a broad bandwidth or a dual-frequency bandwidth. However, it is very difficult to make the IVUS transducer's frequency bandwidth cover from the fundamental frequency to the second harmonic or have a dual-peak at the desired frequency. In order to solve this problem, in this study, we applied the polarization inversion technique (PIT) to the IVUS transducer for THI. The PIT allows relatively easy design of the frequency bandwidth depending on the inversion ratio and the specification of the passive materials, so that the IVUS transducer suitable for THI can be fabricated. In this study, two types of IVUS transducers based on the PIT were developed for THI. One is the front-side inversion layer (FSIL) transducer with broad bandwidth, and the other is the back-side inversion layer (BSIL) transducer with dual-frequency bandwidth. These transducers were designed using finite element analysis (FEA) based simulation, and the prototype transducers were fabricated. Subsequently, the performance was evaluated by not only electrical impedance and pulse-echo response tests, but also B-mode imaging tests with a 25 μm tungsten wire and tissue-mimicking gelatin phantoms. The FEA simulation and experimental results show that the proposed transducer can successfully implement the tissue harmonic IVUS image, and thus it can be one of the promising techniques for developing IVUS transducer for THI.