Goutam Mukherjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Goutam Mukherjee has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Amalendu Samanta
2 shared publicationsA Samanta
1 shared publicationA. Samanta
1 shared publicationPartha Bhowmik
1 shared publication
Latest Publications
- 1 June 2005
- Vol. 121 (6) , 747-58
Effect of chronic use of different propulsion systems in wheelchair design on the aerobic capacity of Indian users.
The use of wheelchairs (WC) of ergonomically different propulsion mechanisms may influence the cardiorespiratory capacity of the WC user. The purpose of the present investigation was to observe the impact of chronic use of four ergonomically different propulsion systems and age of the WC users on their aerobic capacity. The male subjects (n=77), exclusively using hand rim (n=20), arm crank using both arms (n=22), arm crank using one arm (n=17), and arm lever using one arm (n=18) propelled WCs and 20 able-bodied (AB) subjects as the control group participated They performed maximal exercise test in continuous, step-wise incremental workload at a crank rate of 50 rpm on an arm-crank ergometer. The VO(2) and heart rate obtained during 2.45 to 3 min of each test exercise, and VO(2max) and HR(max) were derived respectively. Two-way ANOVA and multiple comparison tests were performed to compare the groups with respect to VO(2max) and HR(max). Age was used as a classificatory variable. The maximal physiological response of the AB subjects was superior to the WC users but the WC user groups did not show any significant differences amongst them. The aerobic capacity decreased with advancement of age and for WC users this is more pronounced. Equations for age predicted VO(2max) and HR(max) were also derived. As the WC users used the four distinct propulsion systems, it was anticipated that it would induce variation in the physiological variables of the users. But the results of the study revealed that there was no significant difference. Suggesting that the WC users might have developed certain self-regulatory mechanisms in order to overcome the variation induced by the different propulsion systems.
- 1 June 2005
- Vol. 121 (6) , 747-58
Effect of chronic use of different propulsion systems in wheelchair design on the aerobic capacity of Indian users.
The use of wheelchairs (WC) of ergonomically different propulsion mechanisms may influence the cardiorespiratory capacity of the WC user. The purpose of the present investigation was to observe the impact of chronic use of four ergonomically different propulsion systems and age of the WC users on their aerobic capacity. The male subjects (n=77), exclusively using hand rim (n=20), arm crank using both arms (n=22), arm crank using one arm (n=17), and arm lever using one arm (n=18) propelled WCs and 20 able-bodied (AB) subjects as the control group participated They performed maximal exercise test in continuous, step-wise incremental workload at a crank rate of 50 rpm on an arm-crank ergometer. The VO(2) and heart rate obtained during 2.45 to 3 min of each test exercise, and VO(2max) and HR(max) were derived respectively. Two-way ANOVA and multiple comparison tests were performed to compare the groups with respect to VO(2max) and HR(max). Age was used as a classificatory variable. The maximal physiological response of the AB subjects was superior to the WC users but the WC user groups did not show any significant differences amongst them. The aerobic capacity decreased with advancement of age and for WC users this is more pronounced. Equations for age predicted VO(2max) and HR(max) were also derived. As the WC users used the four distinct propulsion systems, it was anticipated that it would induce variation in the physiological variables of the users. But the results of the study revealed that there was no significant difference. Suggesting that the WC users might have developed certain self-regulatory mechanisms in order to overcome the variation induced by the different propulsion systems.
- 20 May 2005
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 27 (10) , 591-596
Wheelchair charity: A useless benevolence in community-based rehabilitation
Purpose. Hand rim-propelled manual wheelchairs (WC) are conventionally distributed to persons with dysfunctioning lower limbs for independent ambulation in community-based rehabilitation. The purpose of the present study was to survey the fate of the donated WCs and the difficulties encountered by the users by identifying the cause of rejection, and to evaluate the performance by assessing physiological strain on the recipients during their routine ambulation using cardiorespiratory parameters. Methods. Personal interview was arranged for the recipients and they were to answer regarding the fate of the donated WC and the cause of rejection for the recipients who rejected their WC. A simple field test was also administered to the users to evaluate the ambulatory performance using the WC. The energetics of WC propulsion at freely chosen speed was studied. Results. Of the WC, 10.49% were for attendant-dependent ambulation, 57.4% were not used, 14.19% were sold and 7.4% were in regular use and 10.5% in occasional use. Most of the recipients rejected their WC due to pain, fatigue and discomfort and lack of habitat adaptability. The cardiorespiratory response was higher in occasional users than regular users. Locomotive tasks using WC are highly energy demanding and contribute to physiological strain. Conclusions. Hand rim-propelled manual WC are unsuitable for outdoor ambulation due to low speed and high physiological demand; they are also of little use indoors as they are difficult to maneuver under the environmental conditions and architectural restraints. So, they should not be recommended without proper assessment of the user's activity level and requirements.
- 20 May 2005
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 27 (10) , 591-596
Wheelchair charity: A useless benevolence in community-based rehabilitation
Purpose. Hand rim-propelled manual wheelchairs (WC) are conventionally distributed to persons with dysfunctioning lower limbs for independent ambulation in community-based rehabilitation. The purpose of the present study was to survey the fate of the donated WCs and the difficulties encountered by the users by identifying the cause of rejection, and to evaluate the performance by assessing physiological strain on the recipients during their routine ambulation using cardiorespiratory parameters. Methods. Personal interview was arranged for the recipients and they were to answer regarding the fate of the donated WC and the cause of rejection for the recipients who rejected their WC. A simple field test was also administered to the users to evaluate the ambulatory performance using the WC. The energetics of WC propulsion at freely chosen speed was studied. Results. Of the WC, 10.49% were for attendant-dependent ambulation, 57.4% were not used, 14.19% were sold and 7.4% were in regular use and 10.5% in occasional use. Most of the recipients rejected their WC due to pain, fatigue and discomfort and lack of habitat adaptability. The cardiorespiratory response was higher in occasional users than regular users. Locomotive tasks using WC are highly energy demanding and contribute to physiological strain. Conclusions. Hand rim-propelled manual WC are unsuitable for outdoor ambulation due to low speed and high physiological demand; they are also of little use indoors as they are difficult to maneuver under the environmental conditions and architectural restraints. So, they should not be recommended without proper assessment of the user's activity level and requirements.
- 1 December 2004
- Published by Wolters Kluwer Health in International Journal of Rehabilitation Research
- Vol. 27 (4) , 321-324
Arm-crank propelled three-wheeled chair: physiological evaluation of the propulsion using one arm and both arm patterns
Disabled people in India frequently use the arm-crank propelled three-wheeled chair (ACWC) for outdoor transportation. Two models of these chairs are commercially available: one is powered by cranking using one arm (ACWC-1) and the other uses both arms (ACWC-2). The purpose of the study was to compare the efficiency of the two types of propulsion with respect to the standard physiological responses and, consequent upon the findings, to recommend the use of a suitable one. The energetics of locomotion of the users at their freely chosen speed (FCS) were measured and compared with changes in the physiological parameters in the within-subject groups. The study was conducted in outdoor settings to simulate the actual locomotive conditions encountered by the users in their practical life. 14 males, who had been regular and proficient users of both propulsion systems for more than last six years and who had a history of paraplegia (below the 10th thoracic vertebra, n=11) and poliomyelitis (n=3) participated in the study. The subjects were required to propel the test chair (a combination of both the propulsion systems built in a single model) on an oval track of 358 m circumference at their FCS for 5 min; ambulatory data were collected during last 3 min of exercise and averaged. The FCS (m/min), heart rates (bpm) and oxygen uptake (l/min) were measured. Physiological cost index (b/m) oxygen consumption (ml/kg/min), oxygen cost (ml/kg/m) and net locomotor energy cost (kcal/kg/km) of the two sets of observations were derived and compared using a t-test for the paired observations. The FCS was significantly higher and the physiological parameters were lower with the ACWC-2 than with ACWC-1, except for heart rate and oxygen consumption, where the difference was not significant . It is concluded that two-arm use is more efficient and less physically demanding than one-arm use in the arm-crank propulsion system and that the former is more suitable for efficient ambulation.
- 1 December 2004
- Published by Wolters Kluwer Health in International Journal of Rehabilitation Research
- Vol. 27 (4) , 321-324
Arm-crank propelled three-wheeled chair: physiological evaluation of the propulsion using one arm and both arm patterns
Disabled people in India frequently use the arm-crank propelled three-wheeled chair (ACWC) for outdoor transportation. Two models of these chairs are commercially available: one is powered by cranking using one arm (ACWC-1) and the other uses both arms (ACWC-2). The purpose of the study was to compare the efficiency of the two types of propulsion with respect to the standard physiological responses and, consequent upon the findings, to recommend the use of a suitable one. The energetics of locomotion of the users at their freely chosen speed (FCS) were measured and compared with changes in the physiological parameters in the within-subject groups. The study was conducted in outdoor settings to simulate the actual locomotive conditions encountered by the users in their practical life. 14 males, who had been regular and proficient users of both propulsion systems for more than last six years and who had a history of paraplegia (below the 10th thoracic vertebra, n=11) and poliomyelitis (n=3) participated in the study. The subjects were required to propel the test chair (a combination of both the propulsion systems built in a single model) on an oval track of 358 m circumference at their FCS for 5 min; ambulatory data were collected during last 3 min of exercise and averaged. The FCS (m/min), heart rates (bpm) and oxygen uptake (l/min) were measured. Physiological cost index (b/m) oxygen consumption (ml/kg/min), oxygen cost (ml/kg/m) and net locomotor energy cost (kcal/kg/km) of the two sets of observations were derived and compared using a t-test for the paired observations. The FCS was significantly higher and the physiological parameters were lower with the ACWC-2 than with ACWC-1, except for heart rate and oxygen consumption, where the difference was not significant . It is concluded that two-arm use is more efficient and less physically demanding than one-arm use in the arm-crank propulsion system and that the former is more suitable for efficient ambulation.
- 21 September 2001
- Vol. 38 (4) , 391-9
Physiological response to the ambulatory performance of hand-rim and arm-crank propulsion systems.
Two types of propulsion systems-the hand rim (HR) and the arm crank (AC)-are commonly used in wheelchair ambulation. The purpose of this study was to investigate the physiological response of the two propulsion systems under actual locomotive condition by the actual users. The energetics of locomotion manual wheelchair (HR propulsion) and arm-propelled three-wheeled chairs (AC-propelled) at their free chosen speed (FCS) were studied and compared. Thirty-four male subjects with dysfunctioning lower limbs; 17 manual wheelchair users and 17 arm-propelled three-wheeled chairs regular users volunteered to participate in the study. Speed (m.min-1), oxygen uptake (1 x min(-1)) and heart rate (b x min(-1)) were monitored during steady-state ambulation at FCS for 5 min. Oxygen consumption (VO2, ml x kg(-1) min(-1)), oxygen cost (VO2, ml x kg(-1) m(-1)), net locomotive energy cost (kcal kg(-1) km(-1)) and physiological cost index (b x m(-1)) were derived. The FCS of the AC propelled device is remarkably higher than the HR system, and the magnitude of the physiological variables of the AC propulsion system was significantly lower (p<0.001) in relation to the HR propulsion system, as revealed from the results of t test for two sample means at a significance level p=0.001. It can be inferred from the result that the AC propulsion system could be used for long distance rides with a higher speed required for outdoor ambulation and that the HR propulsion system is suitable only for indoor use, because of its excellent maneuverability where short-duration low-velocity ambulation is required.
- 21 September 2001
- Vol. 38 (4) , 391-9
Physiological response to the ambulatory performance of hand-rim and arm-crank propulsion systems.
Two types of propulsion systems-the hand rim (HR) and the arm crank (AC)-are commonly used in wheelchair ambulation. The purpose of this study was to investigate the physiological response of the two propulsion systems under actual locomotive condition by the actual users. The energetics of locomotion manual wheelchair (HR propulsion) and arm-propelled three-wheeled chairs (AC-propelled) at their free chosen speed (FCS) were studied and compared. Thirty-four male subjects with dysfunctioning lower limbs; 17 manual wheelchair users and 17 arm-propelled three-wheeled chairs regular users volunteered to participate in the study. Speed (m.min-1), oxygen uptake (1 x min(-1)) and heart rate (b x min(-1)) were monitored during steady-state ambulation at FCS for 5 min. Oxygen consumption (VO2, ml x kg(-1) min(-1)), oxygen cost (VO2, ml x kg(-1) m(-1)), net locomotive energy cost (kcal kg(-1) km(-1)) and physiological cost index (b x m(-1)) were derived. The FCS of the AC propelled device is remarkably higher than the HR system, and the magnitude of the physiological variables of the AC propulsion system was significantly lower (p<0.001) in relation to the HR propulsion system, as revealed from the results of t test for two sample means at a significance level p=0.001. It can be inferred from the result that the AC propulsion system could be used for long distance rides with a higher speed required for outdoor ambulation and that the HR propulsion system is suitable only for indoor use, because of its excellent maneuverability where short-duration low-velocity ambulation is required.