MSMark R. Stolzenburg

Mark R. Stolzenburg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Research Interests


Mark R. Stolzenburg has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Peter H. McMurry

    Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota, USA

    3 shared publications
  • Hee-Siew Han

    TSI Incorporated, Shoreview, Minnesota, USA

    1 shared publication
  • Jacob H. T. Scheckman

    TSI Incorporated, Shoreview, Minnesota, USA

    1 shared publication
  • Michel Attoui

    LISA, UMR CNRS 7583, University Paris-Diderot, University Paris-Est Creteil, IPSL, Paris, France

    1 shared publication

Latest Publications

  • Comments on “Effect of the finite width of the temperature transition in diffusive condensation particle counters” by J. Fernandez de la Mora

    by Mark Stolzenburg

    Comments on “Effect of the finite width of the temperature transition in diffusive condensation particle counters” by J. Fernandez de la Mora. Aerosol Science and Technology. Accepted .


  • A review of transfer theory and characterization of measured performance for differential mobility analyzers

    by Mark R. Stolzenburg

    Particle transfer theory for steady-state differential mobility analyzers with and without diffusion is reviewed in detail with a particular focus on the assumptions and approximations made in the analysis. Impacts of the approximations are discussed and, where available, methods to reduce the errors of these approximations are suggested. The non-diffusing theory uses just one approximation, affecting the centroid calculation, which can be readily addressed via numerical modeling of the electric field. The diffusing theory makes numerous approximations to achieve an analytical expression. One of the most serious of these, neglecting secondary flows in the vicinities of the aerosol entrance and exit slits, could be improved upon using a numerical model of the flow field. Losses in the aerosol entrance plumbing can perturb the inlet profile to the classification region. The maximum effects on the transfer function are estimated to be a 1% increase in the mean mobility and a 14% reduction of the non-diffusing contribution to the variance. Methods of fitting transfer theory to measurements are also reviewed. TDMA measurements generally do not have the resolving power to distinguish different shapes of the transfer function but newer measurements using truly monomobile ions have the potential to more rigorously test the diffusive transfer model. In adjusting the width of the theoretical transfer function to fit measurements from a real DMA demonstrating non-ideal performance, it is physically more meaningful and accurate to use an additive adjustment to the variance as opposed to a multiplicative adjustment to the width.


  • Characterization of the TSI model 3086 differential mobility analyzer for classifying aerosols down to 1 nm

    by Mark R. Stolzenburg, Jacob H. T. Scheckman, Michel Attoui, Hee-Siew Han, Peter H. McMurry

    Measurement systems for particle sizing starting at 1 nm are used to bridge the gap between mass spectrometer measurements and traditional aerosol sizing methods, and thus to enable measurement of the complete size distribution from molecules and clusters to large particles. Such a measurement can be made using a scanning mobility particle sizer equipped with a diethylene glycol growth engine (e.g., TSI Model 3777 Nano Enhancer) along with a condensation particle counter, and a differential mobility analyzer (DMA) appropriate for such small sizes. Previous researchers have used high-resolution DMA (HRDMA) and also the TSI Nano-DMA (Model 3085) in such a scanning mobility particle sizer system. In this study, we evaluate the performance of the recently introduced TSI 1 nm-DMA (Model 3086). The transfer function was characterized using 1–2 nm monomobile molecular ion standards. The same measurements were repeated on a TSI Nano-DMA, with good agreement to previously published values. From the measured transfer function, the resolution of each DMA model was determined as a function of particle size and sheath flow rate. Resolution of the TSI 3086 in the 1–2 nm range was 10–25% higher than the TSI 3085. Measured resolutions of the TSI 3086 were 10–20% lower than theoretically predicted values, whereas those of the Model 3085 were 0–10% lower. Copyright © 2018 TSI Inc.


  • Accuracy of recovered moments for narrow mobility distributions obtained with commonly used inversion algorithms for mobility size spectrometers

    by Mark R. Stolzenburg, Peter H. McMurry

    Aerosol mobility size spectrometers are commonly used to measure size distributions of submicrometer aerosol particles. Commonly used data inversion algorithms for these instruments assume that the measured mobility distribution is broad relative to the DMA transfer function. This article theoretically examines errors that are incurred for input distributions of any width with an emphasis on those with mobility widths comparable to that of the DMA's transfer function. Our analysis is valid in the limit of slow scan rates, and is applicable to the interpretation of measurements such as those obtained with tandem differential mobility analyzers as well as broader distributions. The analysis leads to expressions that show the relationship between the inverted number concentration, mean size, and standard deviation and true values of those parameters. For narrow distributions (e.g., for a mobility distribution produced by a DMA with a 1:10 aerosol:sheath air flow ratio) under typical operating conditions, number concentrations and mean mobility obtained with inversion algorithms are accurate to within 0.5% and 1.0%, respectively. This corresponds to mean diameter retrieval errors of 1.0% for large particles and 0.5% for small (kinetic regime) particles. The widths (i.e., relative mobility variance) of the inverted distributions, however, significantly exceed the true values. Copyright © 2018 American Association for Aerosol Research


  • Open Access

    Method to assess performance of scanning mobility particle sizer (SMPS) instruments and software

    by Mark R. Stolzenburg, Peter H. McMurry

    (2018). Method to assess performance of scanning mobility particle sizer (SMPS) instruments and software. Aerosol Science and Technology: Vol. 52, No. 6, pp. 609-613.