Lianqiong Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lianqiong Zheng has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Gui-Yun Yan
2 shared publications- Ai Qi
College of Civil Engineering, Fuzhou University, Fuzhou 350116, China
1 shared publication Chang-Gui Wei
School of Civil Engineering, Fujian University of Technology, Fuzhou, People’s Republic of China
1 shared publicationChanggui Wei
Fujian University of Technology
1 shared publication- Chen Wu
School of Civil Engineering, FuJian University of Technology, Fuzhou 350118, China
1 shared publication Guiyun Yan
Fujian University of Technology
1 shared publication
Latest Publications
- 30 May 2026
- Published by Elsevier in Structures
- Vol. 89
Behavior of eccentrically loaded recycled brick aggregate geopolymer concrete-filled corrugated steel tube columns
- 30 May 2026
- Published by Elsevier in Structures
- Vol. 89
Behavior of eccentrically loaded recycled brick aggregate geopolymer concrete-filled corrugated steel tube columns
- Open Access
Seismic Performance of Cladding-Panel-Equipped Frames with Novel Friction-Energy-Dissipating Joints
Based on the need to enhance the seismic performance of point-supported steel frame precast cladding panel systems, this study proposes a novel friction-energy-dissipating connection joint. Through establishing refined finite element models, low-cycle reversed loading analyses and elastoplastic time-history analyses were conducted on three frame systems. These included a benchmark bare frame and two cladding-panel-equipped frame structures configured with energy-dissipating joints using different specifications of high-strength bolts (M14 and M20, respectively). The low-cycle reversed loading results demonstrate that the friction energy dissipation of the novel joints significantly improved the seismic performance of the frame structures. Compared to the bare frame, the frames equipped with cladding panels using M14 bolts demonstrated 10.9% higher peak lateral load capacity, 17.6% greater lateral stiffness, and 45.6% increased cumulative energy dissipation, while those with M20 bolts showed more substantial improvements of 22.8% in peak load capacity, 32.0% in lateral stiffness, and 64.2% in cumulative energy dissipation. The elastoplastic time-history analysis results indicate that under seismic excitation, the maximum inter-story drift ratios of the panel-equipped frames with M14 and M20 bolts were reduced by 42.7% and 53%, respectively, compared to the bare frame. Simultaneously, the equivalent plastic strain in the primary structural members significantly decreased. Finally, based on the mechanical equilibrium conditions, a calculation formula was derived to quantify the contribution of joint friction to the horizontal load-carrying capacity of the frame.
Open AccessSeismic Performance of Cladding-Panel-Equipped Frames with Novel Friction-Energy-Dissipating Joints
Based on the need to enhance the seismic performance of point-supported steel frame precast cladding panel systems, this study proposes a novel friction-energy-dissipating connection joint. Through establishing refined finite element models, low-cycle reversed loading analyses and elastoplastic time-history analyses were conducted on three frame systems. These included a benchmark bare frame and two cladding-panel-equipped frame structures configured with energy-dissipating joints using different specifications of high-strength bolts (M14 and M20, respectively). The low-cycle reversed loading results demonstrate that the friction energy dissipation of the novel joints significantly improved the seismic performance of the frame structures. Compared to the bare frame, the frames equipped with cladding panels using M14 bolts demonstrated 10.9% higher peak lateral load capacity, 17.6% greater lateral stiffness, and 45.6% increased cumulative energy dissipation, while those with M20 bolts showed more substantial improvements of 22.8% in peak load capacity, 32.0% in lateral stiffness, and 64.2% in cumulative energy dissipation. The elastoplastic time-history analysis results indicate that under seismic excitation, the maximum inter-story drift ratios of the panel-equipped frames with M14 and M20 bolts were reduced by 42.7% and 53%, respectively, compared to the bare frame. Simultaneously, the equivalent plastic strain in the primary structural members significantly decreased. Finally, based on the mechanical equilibrium conditions, a calculation formula was derived to quantify the contribution of joint friction to the horizontal load-carrying capacity of the frame.
- Open Access
Experiment Study on the Hysteretic Performance of a Novel Replaceable Beam-to-Column Joint with Energy-Dissipating Steel Hinge
A novel precast replaceable beam-to-column joint with energy-dissipating steel hinges was proposed for the connection of precast structures to improve the seismic performance and post-earthquake resilience. The proposed joint was installed in the predetermined plastic hinge region at beams and the flange segments of the proposed joint were weakened to achieve damage concentration. Cyclic loading tests were conducted on the proposed joint and the steel sleeve confined concrete joint to study the hysteretic performance, including failure mode, load–displacement curves, ductility, and energy-dissipation capacity. Moreover, the hystertic performance of the damage-repaired proposed joint was investigated to verify the post-earthquake resilience. Results demonstrated that the proposed joints could develop favorable failure mode with the necking rupture of the weakened steel plate in steel hinge. The damage of the proposed joint was concentrated in the energy-dissipating hinges while no serious damage was observed in the precast framing components, achieving the objective of damage concentration. Compared with steel sleeve confined concrete joint, the hysteresis curve of proposed joint was more plump while an obvious pinching effect was observed in the steel-confined concrete joint. The bearing capacity and energy-dissipation capacity of the proposed joint were about 1.25 times and 1.55 times of that for the steel sleeve confined concrete joint, respectively. In addition, the hysteretic performance of the repaired specimen was identical to the original one, with the desired failure mode caused by the fracture of the steel hinge. It was noted that the hysteretic performance of the repaired joint was better than the steel sleeve confined concrete joint. The bearing capacity was recovered at up to 96.6% of the original joint while the energy-dissipation capacity was recovered at 96.1%, indicating that the proposed joint achieved the post-earthquake resilience to a great extent.
Open AccessExperiment Study on the Hysteretic Performance of a Novel Replaceable Beam-to-Column Joint with Energy-Dissipating Steel Hinge
A novel precast replaceable beam-to-column joint with energy-dissipating steel hinges was proposed for the connection of precast structures to improve the seismic performance and post-earthquake resilience. The proposed joint was installed in the predetermined plastic hinge region at beams and the flange segments of the proposed joint were weakened to achieve damage concentration. Cyclic loading tests were conducted on the proposed joint and the steel sleeve confined concrete joint to study the hysteretic performance, including failure mode, load–displacement curves, ductility, and energy-dissipation capacity. Moreover, the hystertic performance of the damage-repaired proposed joint was investigated to verify the post-earthquake resilience. Results demonstrated that the proposed joints could develop favorable failure mode with the necking rupture of the weakened steel plate in steel hinge. The damage of the proposed joint was concentrated in the energy-dissipating hinges while no serious damage was observed in the precast framing components, achieving the objective of damage concentration. Compared with steel sleeve confined concrete joint, the hysteresis curve of proposed joint was more plump while an obvious pinching effect was observed in the steel-confined concrete joint. The bearing capacity and energy-dissipation capacity of the proposed joint were about 1.25 times and 1.55 times of that for the steel sleeve confined concrete joint, respectively. In addition, the hysteretic performance of the repaired specimen was identical to the original one, with the desired failure mode caused by the fracture of the steel hinge. It was noted that the hysteretic performance of the repaired joint was better than the steel sleeve confined concrete joint. The bearing capacity was recovered at up to 96.6% of the original joint while the energy-dissipation capacity was recovered at 96.1%, indicating that the proposed joint achieved the post-earthquake resilience to a great extent.
- 16 January 2022
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 20 (3) , 1865-1895
Seismic performance of prefabricated beam-to-column joint with replaceable energy-dissipating steel hinge
- 16 January 2022
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 20 (3) , 1865-1895
Seismic performance of prefabricated beam-to-column joint with replaceable energy-dissipating steel hinge
- Open Access
- 24 July 2021
- Published by Springer Nature in Research Square
Seismic Performance of Prefabricated Beam-to-column Joint with Replaceable Energy-dissipating Steel Hinge
This study presents a novel energy-dissipating prefabricated joint for connecting beam to column in a precast frame structure. The joints are characterized by a replaceable steel hinge and a prefabricated steel tube confined joint core, providing advantages for precast concrete reinforced frames, such as complete assembly, damage control, and maintainability of the structure after an earthquake. The hysteretic behavior of the proposed prefabricated joint was studied through two tests. First, a full-scale prefabricated joint was tested under cyclic loading until failure. On the basis of the initial test, only four weakened dissipaters of the steel hinges in the prefabricated joint were replaced and the second test was conducted to investigate the restorable functional characteristics of the proposed prefabricated joints. For comparison, a reference monolithic joint was also tested. The experimental results demonstrate that the novel prefabricated beam-to-column joint displayed excellent hysteretic performance, and corresponding to the monolithic joint, the load-bearing, energy dissipation, and deformation capacity were improved. The damage of the prefabricated joint was concentrated on the weakened dissipaters of the steel hinges, indicating that the failure mode and damage degree of the prefabricated joint can be controlled. In the second test, the prefabricated joint exhibited similar hysteretic behavior to that of the first test; however, the initial stiffness was slightly lower. Therefore, the prefabricated joint can meet the replaceability requirement and achieve satisfactory beam-to-column joint function recovery after an earthquake.
- 24 July 2021
- Published by Springer Nature in Research Square
Open AccessSeismic Performance of Prefabricated Beam-to-column Joint with Replaceable Energy-dissipating Steel Hinge
This study presents a novel energy-dissipating prefabricated joint for connecting beam to column in a precast frame structure. The joints are characterized by a replaceable steel hinge and a prefabricated steel tube confined joint core, providing advantages for precast concrete reinforced frames, such as complete assembly, damage control, and maintainability of the structure after an earthquake. The hysteretic behavior of the proposed prefabricated joint was studied through two tests. First, a full-scale prefabricated joint was tested under cyclic loading until failure. On the basis of the initial test, only four weakened dissipaters of the steel hinges in the prefabricated joint were replaced and the second test was conducted to investigate the restorable functional characteristics of the proposed prefabricated joints. For comparison, a reference monolithic joint was also tested. The experimental results demonstrate that the novel prefabricated beam-to-column joint displayed excellent hysteretic performance, and corresponding to the monolithic joint, the load-bearing, energy dissipation, and deformation capacity were improved. The damage of the prefabricated joint was concentrated on the weakened dissipaters of the steel hinges, indicating that the failure mode and damage degree of the prefabricated joint can be controlled. In the second test, the prefabricated joint exhibited similar hysteretic behavior to that of the first test; however, the initial stiffness was slightly lower. Therefore, the prefabricated joint can meet the replaceability requirement and achieve satisfactory beam-to-column joint function recovery after an earthquake.
- 1 October 2020
- Published by Elsevier in Structures
- Vol. 27, 934-949
Seismic behaviour of concrete-filled steel tubular column and precast shear wall connections
- 1 October 2020
- Published by Elsevier in Structures
- Vol. 27, 934-949
Seismic behaviour of concrete-filled steel tubular column and precast shear wall connections
- Open Access
- 23 February 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (4) , 1672
An Informatization Scheme for Construction and Demolition Waste Supervision and Management in China
China is in a development period of urbanization construction, while its environment is threatened by an increasing amount of construction and demolition (C&D) waste. Due to the excessive pursuit of profits and a general lack of environmental awareness of stakeholders, illegal behaviors such as illegal dumping universally exist in the waste disposal process. Meanwhile, supervision departments face many challenges in collaborative management and decision-making, which lead to inefficiencies in C&D waste supervision and management in China. To address the above challenges, we propose an informatization scheme integrating multiple technologies, which will contribute to real-time monitoring of illegal behaviors in the waste disposal process, accurate data collection for evaluating the performance of stakeholders, and the enhancement of the collaboration between supervisory departments. A case study of the Ningbo Construction Waste Transportation Supervision System is introduced to verify the feasibility and effectiveness of the proposed scheme; results show that the total number of illegal cases has decreased from 510 to 89 per year since the system was put into operation.
- 23 February 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (4) , 1672
Open AccessAn Informatization Scheme for Construction and Demolition Waste Supervision and Management in China
China is in a development period of urbanization construction, while its environment is threatened by an increasing amount of construction and demolition (C&D) waste. Due to the excessive pursuit of profits and a general lack of environmental awareness of stakeholders, illegal behaviors such as illegal dumping universally exist in the waste disposal process. Meanwhile, supervision departments face many challenges in collaborative management and decision-making, which lead to inefficiencies in C&D waste supervision and management in China. To address the above challenges, we propose an informatization scheme integrating multiple technologies, which will contribute to real-time monitoring of illegal behaviors in the waste disposal process, accurate data collection for evaluating the performance of stakeholders, and the enhancement of the collaboration between supervisory departments. A case study of the Ningbo Construction Waste Transportation Supervision System is introduced to verify the feasibility and effectiveness of the proposed scheme; results show that the total number of illegal cases has decreased from 510 to 89 per year since the system was put into operation.
- Open Access
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Impact Tensile Behaviors of PVDF Building Coated Fabrics
The paper presents the impact tensile behaviors of two common building membranes (Ferrari 1002T2 membrane and XYD 300N membrane) in PVDF‐coated‐fabric membrane structures. The tests are conducted using the split Hopkinson bar test device. Typical forms of stress and strain are applied for comparing the stress‐strain relationship between quasi‐static and high strain rates. Besides, the failure mechanism and energy absorption at high strain rates are discussed. The results show that with the increase of strain rates, the growth rate of the stress of PVDF membrane decreases gradually, which is different from the stress‐strain relationship in low strain rates. At high strain rates, the ultimate tensile strength increases linearly with the increase of strain rates. In addition, the energy absorption capacity of the material increases with the increase of strain rates. The results can provide an important basis for the design and analysis of membrane structures under the impact loads.
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Open AccessImpact Tensile Behaviors of PVDF Building Coated Fabrics
The paper presents the impact tensile behaviors of two common building membranes (Ferrari 1002T2 membrane and XYD 300N membrane) in PVDF‐coated‐fabric membrane structures. The tests are conducted using the split Hopkinson bar test device. Typical forms of stress and strain are applied for comparing the stress‐strain relationship between quasi‐static and high strain rates. Besides, the failure mechanism and energy absorption at high strain rates are discussed. The results show that with the increase of strain rates, the growth rate of the stress of PVDF membrane decreases gradually, which is different from the stress‐strain relationship in low strain rates. At high strain rates, the ultimate tensile strength increases linearly with the increase of strain rates. In addition, the energy absorption capacity of the material increases with the increase of strain rates. The results can provide an important basis for the design and analysis of membrane structures under the impact loads.