SSSaeed Samaei

Saeed Samaei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Saeed Samaei has a total of 90 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cerebral Hemodynamic and Metabolic Responses to Anesthesia and Vasopressors in Adult Shoulder Surgery: A 2 × 2 Factorial Design Randomized Controlled Trial with Light-based Neuromonitoring (CHEM-FACT Study)

    by Saeed Samaei, Leena Shoemaker, Farah Kamar, Daniel Milej, Darren Drosdowech, John M. Murkin, Mamadou Diop, Keith St. Lawrence, Jason Chui

    Background: Ephedrine has been suggested to improve cerebral microcirculation and perfusion compared with phenylephrine. However, prospective intraoperative data are lacking, and possible interactions with anesthetic choice remain untested. Methods: Forty adults undergoing shoulder surgery in the beach chair position were recruited between February and November 2024 at St. Joseph’s Hospital (London, Canada). Patients were randomized in a 2 × 2 factorial design to anesthetic maintenance (propofol vs . sevoflurane) and vasopressor strategy (phenylephrine infusion vs . ephedrine boluses). Relative tissue oxygenation saturation (rStO 2 ) and the relative cerebral metabolic rate of oxygen (rCMRO 2 ), the coprimary outcomes, were monitored using an in-house hybrid optical system combining time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy. Only data from the first 30 min after positioning were analyzed. Outcomes and interactions were assessed using linear mixed-effects models. Results: Of the 40 patients, 39 were analyzed. Neither anesthetic nor vasopressor choice showed a significant main effect on average rStO 2 or rCMRO 2 during the 30-min period. However, analysis of temporal changes revealed rStO 2 declined over time (β = –0.005 per minute; χ 2 (1) = 10.2; P = 0.001), while rCMRO 2 increased (β = 3.2 per minute; χ 2 (1) = 35.2; P < 0.001). There was a time by vasopressor interaction for rStO 2 (β = –0.0014; χ 2 (1) = 8.4; P = 0.004), with phenylephrine producing a 9% greater decline during 30 min compared to ephedrine, while for relative rCMRO 2 (β = 2.2; 95% CI, 0.6 to 3.8; P = 0.007), phenylephrine produced a 70% increase during 30 min. Conclusions: This trial found no overall effect of anesthetic or vasopressor choice on rStO 2 or rCMRO 2 during the first 30 min of surgery, suggesting that initial cerebral physiologic responses were comparable across treatment combinations. However, phenylephrine was associated with progressive cerebral desaturation and increasing metabolic demand over time.


  • Open Access

    Wearable near-infrared spectroscopy device for low-resource settings

    by Saeed Samaei, Rasa Eskandari, Leena Shoemaker, Natalie Li, Farah Kamar, Lee David Sikstrom, David Holdsworth, Mamadou Diop

    There is a global need for accessible cerebral monitoring in low-resource settings. A low-cost, wearable near-infrared spectroscopy device was developed using a commercially available optical biosensing module. The device features wireless data transmission, dual-wavelength illumination, and supports dual-slope analysis for improved brain sensitivity. Its performance and depth sensitivity were validated through layered blood phantoms and in vivo experiments, demonstrating stable operation, reliable signal quality, and accurate detection of cerebral oxygenation changes in adult head mimicking phantoms and healthy adult volunteers. The device is low-cost, reproducible with minimal engineering skills, easy to use, and reliable for in vivo human experiments, highlighting its potential as a practical tool for non-invasive brain monitoring, particularly in low-resource environments. The data-processing codes and the 3D-printable probe design files have all been open-sourced and are publicly available.

  • Open Access

    Reproducibility of a time-resolved NIRS, multidistance diffuse correlation spectroscopy system: towards noninvasive longitudinal neuromonitoring

    by Farah Kamar, Leena N. Shoemaker, Saeed Samaei, Daniel Milej, Mamadou Diop, Keith St. Lawrence

    SignificanceLongitudinal monitoring of cerebral blood flow (CBF), oxygenation (StO2), and cerebral metabolic rate of oxygen (CMRO2) could allow for early detection of secondary brain injury before clinical signs manifest.AimReproducibility and reliability of an in-house time-resolved near-infrared spectroscopy (trNIRS)/multidistance diffuse correlation spectroscopy (mdDCS) system were assessed to determine the feasibility of daily monitoring. In addition, carotid compression was performed to demonstrate longitudinal monitoring.ApproachTime-resolved NIRS/mdDCS measurements were acquired daily on volunteers across one week. Reproducibility was quantified by the coefficient of variation (CV) and reliability by the intraclass correlation coefficient (ICC) at three levels: within-acquisition, between-acquisition, and between-day. A subset of participants returned on day 21+, and carotid compression was performed to reduce CBF. Signal changes during compression were compared to baseline measurements from that day and previous days.ResultsAll optical measurements showed good-to-excellent within-acquisition, between-acquisition, and between-day reproducibility (CV<19%) and reliability (ICC between 0.67 and 0.99), except short-distance DCS, which was sensitive to probe repositioning. Reductions in CBF, StO2, and CMRO2 caused by carotid compression were similar in magnitude when using same-day baseline to baseline values up to three weeks prior.ConclusionsThis study demonstrates the feasibility of daily monitoring using a hybrid trNIRS/mdDCS system.

  • Noninvasive estimation of superficial layer thickness using multi-channel diffuse correlation spectroscopy

    by Saeed Samaei, Daniel Milej, Keith St. Lawrence

    Diffuse correlation spectroscopy (DCS) is a promising, noninvasive, light-based method for continuous bedside monitoring of cerebral blood flow. However, its sensitivity to brain tissue is affected by extracerebral layers. Although layered-model analysis improves cerebral perfusion measurement accuracy, it requires precise knowledge of the properties of superficial layers. To address this challenge, we demonstrate a method for quantifying superficial blood flow dynamics and thickness using three-channel DCS measurements. The approach was validated via simulation and layered phantom experiments. Results demonstrated that an accurate superficial-layer blood flow index can be obtained by adjusting photon count rates at short separations. In turn, this enabled estimation of the superficial-layer thickness and the lower-layer blood flow index from DCS data acquired at two long source-detector separations.


  • Quantification of oxidized and reduced cytochrome-c-oxidase by combining discrete-wavelength time-resolved and broadband continuous-wave near-infrared spectroscopy

    by Rasa Eskandari, Natalie C. Li, Saeed Samaei, Daniel Milej, Keith St. Lawrence, Mamadou Diop

    Quantification of cytochrome-c-oxidase (CCO) can directly inform about cerebral metabolic capacity and function, but limited options currently exist for its in vivo assessment. Near-infrared spectroscopy (NIRS) has the potential to quantify CCO and its redox states, but hyperspectral absorption measurements are required due to their broad absorption profiles and low concentrations relative to hemoglobin. While this may be achieved with continuous-wave broadband NIRS (bNIRS), separating the signal contributions of absorption and scattering remains a challenge. Alternatively, time-resolved NIRS (trNIRS) can directly disentangle absorption and scattering but is typically constrained to a few wavelengths. This work aimed to develop an approach for quantifying absolute CCO concentration using discrete-wavelength trNIRS to calibrate bNIRS, yielding calibrated bNIRS (cbNIRS). Monte-Carlo simulations were conducted to validate the algorithm. Subsequently, a hybrid cbNIRS system was assembled, and tissue-mimicking phantoms were prepared with blood, Intralipid, and either yeast or sodium dithionite for validation. The simulations demonstrated that the algorithm can accurately measure absorption across the spectral range (error = 0.8 ± 0.4%). Further, the concentrations of CCO and its different redox states were estimated with an error of 7.9% or less. In the phantom experiments, the measured HbT concentration increased with the addition of blood, but not yeast nor sodium dithionite, and the value agreed with the expected concentration estimated from the packed cell volume of blood. A large increase in total CCO was measured only after the addition of yeast (1.8 ± 0.4 µM). Transitions in the oxygenation state of hemoglobin and redox state of CCO followed the expected trends as the phantom was deoxygenated and reoxygenated. Additionally, the sodium dithionite experiments confirmed that the COO signal measured with cbNIRS is not a result of crosstalk with the hemoglobin signal. This work demonstrates that absolute concentrations of both redox states of CCO can be quantified with high accuracy using cbNIRS. Future work will assess the feasibility of in vivo CCO measurements.


  • Cost-effective neonatal cerebral oximeter for low-resource settings (Conference Presentation)

    by Saeed Samaei, Natalie C. Li, Lee D. Sikstrom, David W. Holdsworth, Mamadou Diop

    We developed a wireless near-infrared spectroscopy (NIRS) device for neonatal neuromonitoring in resource-limited settings. The module is wearable and was built using a consumer-grade fitness tracker band. Unique features of the device include a high sampling rate, an efficient noise-canceling algorithm, and the ability to simultaneously measure hemodynamic parameters and heart rate. We illustrated the capability of the device to monitor tissue hemodynamics through a series of phantom and in-vivo experiments. This development holds promise for advancing noninvasive neonatal neuromonitoring in low-resource settings.

  • Open Access

    All-optics technique for monitoring absolute cerebral blood flow: validation against magnetic resonance imaging perfusion

    by Leena N. Shoemaker, Saeed Samaei, Graham Deller, Danny J. J. Wang, Daniel Milej, Keith St. Lawrence

    Worldwide, acquired brain injuries—ischemic stroke, severe traumatic brain injury, and subarachnoid hemorrhage—are major killers and extremely resource-demanding in terms of direct healthcare costs and long-term disability.1 Intensive care of patients with life-threatening acquired brain injuries not only saves lives but improves neurological outcomes. A primary focus is preventing delayed cerebral ischemia by treating complications that can impede oxygen delivery to the brain, such as systemic hypotension and elevated intracranial pressure.2 Clinical features related to neurological deficits (e.g., paresis) are used to detect worsening neurological status, but these often manifest after ischemic injury has occurred and are not reliable indicators in patients requiring sedation. Studies using invasive probes capable of quantifying cerebral blood flow (CBF), such as thermal diffusion flowmetry, suggested that CBF monitoring improves outcomes by alerting the intensivist team when CBF falls below ischemic thresholds.3 The invasiveness of such probes has hindered greater adoption and speaks to the need to develop non-invasive alternatives.


  • Time-domain diffuse correlation spectroscopy performance at different source-detector separation

    by Neda Mogharari, Saeed Samaei, Stanislaw Wojtkiewicz, Adam Liebert, Michal Kacprzak

    Time domain diffuse correlation spectroscopy (td-DCS), has been proposed as a method that can increase the sensitivity of DCS for detecting blood flow index (BFI) in deep tissue. Several important parameters including the instrument response function (IRF), gate start time, gate width, and source-detector separation (SDS) must be taken into consideration. In our study, we characterized td-DCS system at three different SDS values and assessed each SDS's ability to detect dynamic changes of blood flow caused by moving red blood cells during cuff occlusion.


  • Continuous-wave parallel interferometric near-infrared spectroscopy (CW πNIRS) with a fast two-dimensional camera

    by Saeed Samaei, Klaudia Nowacka, Anna Gerega, Żanna Pastuszak, Dawid Borycki

    Interferometric near-infrared spectroscopy (iNIRS) is an optical method that noninvasively measures the optical and dynamic properties of the human brain in vivo. However, the original iNIRS technique uses single-mode fibers for light collection, which reduces the detected light throughput. The reduced light throughput is compensated by the relatively long measurement or integration times (∼1 sec), which preclude monitoring of rapid blood flow changes that could be linked to neural activation. Here, we propose parallel interferometric near-infrared spectroscopy (πNIRS) to overcome this limitation. In πNIRS we use multi-mode fibers for light collection and a high-speed, two-dimensional camera for light detection. Each camera pixel acts effectively as a single iNIRS channel. So, the processed signals from each pixel are spatially averaged to reduce the overall integration time. Moreover, interferometric detection provides us with the unique capability of accessing complex information (amplitude and phase) about the light remitted from the sample, which with more than 8000 parallel channels, enabled us to sense the cerebral blood flow with only a 10 msec integration time (∼100x faster than conventional iNIRS). In this report, we have described the theoretical foundations and possible ways to implement πNIRS. Then, we developed a prototype continuous wave (CW) πNIRS system and validated it in liquid phantoms. We used our CW πNIRS to monitor the pulsatile blood flow in a human forearm in vivo. Finally, we demonstrated that CW πNIRS could monitor activation of the prefrontal cortex by recording the change in blood flow in the forehead of the subject while he was reading an unknown text.