Xingwei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingwei Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Hao Wang
CECEP L&T Environmental Technology Co. Ltd., Beijing 100085, China
1 shared publication- Jiajun Chen
Key Laboratory for Water and Sediment Sciences of Ministry of Education, School of Environment, Beijing Normal University, Beijing 100875, China
1 shared publication - Jiajun Chen
Environmental Science Program Division of Science and Technology Beijing Normal University-Hong Kong Baptist University United International College Zhuhai China
1 shared publication Jianfei Liu
School of Civil Engineering, Henan Polytechnic University, Jiaozuo 454003, China
1 shared publication- Jianfei Liu
Peking University
1 shared publication - Lin Jiang
National Engineering Research Centre of Urban Environmental Pollution Control, Beijing Key Laboratory for Risk Modeling and Remediation of Contaminated Sites, Beijing Municipal Research Institute of Eco-Environmental Protection, Beijing 100037, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2014
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2014 (1)
Generalizing Source Geometry of Site Contamination by Simulating and Analyzing Analytical Solution of Three‐Dimensional Solute Transport Model
Due to the uneven distribution of pollutions and blur edge of pollutant area, there will exist uncertainty of source term shape in advective‐diffusion equation model of contaminant transport. How to generalize those irregular source terms and deal with those uncertainties is very critical but rarely studied in previous research. In this study, the fate and transport of contaminant from rectangular and elliptic source geometry were simulated based on a three‐dimensional analytical solute transport model, and the source geometry generalization guideline was developed by comparing the migration of contaminant. The result indicated that the variation of source area size had no effect on pollution plume migration when the plume migrated as far as five times of source side length. The migration of pollution plume became slower with the increase of aquifer thickness. The contaminant concentration was decreasing with scale factor rising, and the differences among various scale factors became smaller with the distance to field increasing.
- 1 January 2014
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2014 (1)
Open AccessGeneralizing Source Geometry of Site Contamination by Simulating and Analyzing Analytical Solution of Three‐Dimensional Solute Transport Model
Due to the uneven distribution of pollutions and blur edge of pollutant area, there will exist uncertainty of source term shape in advective‐diffusion equation model of contaminant transport. How to generalize those irregular source terms and deal with those uncertainties is very critical but rarely studied in previous research. In this study, the fate and transport of contaminant from rectangular and elliptic source geometry were simulated based on a three‐dimensional analytical solute transport model, and the source geometry generalization guideline was developed by comparing the migration of contaminant. The result indicated that the variation of source area size had no effect on pollution plume migration when the plume migrated as far as five times of source side length. The migration of pollution plume became slower with the increase of aquifer thickness. The contaminant concentration was decreasing with scale factor rising, and the differences among various scale factors became smaller with the distance to field increasing.
- 25 August 2013
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 21 (3) , 1809-1818
Adsorption of fluoranthene in surfactant solution on activated carbon: equilibrium, thermodynamic, kinetic studies
Adsorption of fluoranthene (FLA) in surfactant solution on activated carbon (AC) was investigated. Isotherm, thermodynamic, and kinetic attributes of FLA adsorption in the presence of the surfactant on AC were studied. Effects of AC dosage, initial concentration of TX100, initial concentration of FLA, and addition of fulvic acid on adsorption were studied. The experimental data of both TX100 and FLA fitted the Langmuir isotherm model and the pseudo-second-order kinetic model well. Positive enthalpy showed that adsorption of FLA on AC was endothermic. The efficiency of selective FLA removal generally increased with increasing initial surfactant concentration and decreasing fulvic acid concentration. The surface chemistry of AC may determine the removal of polycyclic aromatic hydrocarbons. The adsorption process may be controlled by the hydrophobic interaction between AC and the adsorbate. The microwave irradiation of AC may be a feasible method to reduce the cost of AC through its regeneration.
- 25 August 2013
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 21 (3) , 1809-1818
Adsorption of fluoranthene in surfactant solution on activated carbon: equilibrium, thermodynamic, kinetic studies
Adsorption of fluoranthene (FLA) in surfactant solution on activated carbon (AC) was investigated. Isotherm, thermodynamic, and kinetic attributes of FLA adsorption in the presence of the surfactant on AC were studied. Effects of AC dosage, initial concentration of TX100, initial concentration of FLA, and addition of fulvic acid on adsorption were studied. The experimental data of both TX100 and FLA fitted the Langmuir isotherm model and the pseudo-second-order kinetic model well. Positive enthalpy showed that adsorption of FLA on AC was endothermic. The efficiency of selective FLA removal generally increased with increasing initial surfactant concentration and decreasing fulvic acid concentration. The surface chemistry of AC may determine the removal of polycyclic aromatic hydrocarbons. The adsorption process may be controlled by the hydrophobic interaction between AC and the adsorbate. The microwave irradiation of AC may be a feasible method to reduce the cost of AC through its regeneration.