JJJosé Ramón Jiménez

José Ramón Jiménez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


José Ramón Jiménez has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Parental awareness of the implications of myopia and strategies to control its progression: A survey‐based study

    by Sonia Ortiz‐Peregrina, Salvador Solano‐Molina, Francesco Martino, José J. Castro‐Torres, José R. Jiménez

    Purpose: Myopia has emerged as a significant public health concern. Effective methods have now been developed to delay its onset and progression. However, this information may not be reaching parents, and they are key players in terms of implementing the necessary preventive measures. This study investigated parental awareness of myopia, its implications and the strategies available for controlling it. Methods: A self‐administered online survey was distributed to parents of children 6–16 years of age. To be eligible to respond, their child had to be myopic or at risk of developing myopia due to family history. Results: A total of 330 parents completed the survey, of which 321 were included for analysis. Sixty‐seven percent of respondents had at least one myopic son/daughter, and most were between −1.00 and −1.75 D. Among parents of myopic children, 20.9% thought that their child's myopia progressed moderately. Sixty‐seven percent of parents had a significant level of concern about the progression of the myopia and felt that it was caused mainly by the use of electronic devices and genetics. A generalised linear model showed that parental concern was significantly predicted by the perception of evolution ( p < 0.001) and the number of known health‐related consequences ( p < 0.001). Almost 40% of parents were unaware of the existence of myopia control strategies. Relatives and eye care practitioners are the main sources of information. The most well‐known myopia control strategy was myopia control soft contact lenses (29.2%), although the option that most parents would opt for was spectacles with peripheral defocus lenses (47.1%). The selection of a contact‐lens‐based myopia control method correlated significantly with the age of the children ( p < 0.001). Conclusions: Society in general and parents in particular need more information about myopia, its consequences and the options available for its control. Eye care practitioners play an important role in this issue.


  • Open Access

    Influence of Interocular Differences and Alcohol Consumption on Binocular Visual Performance

    by Francesco Martino, José J. Castro-Torres, Miriam Casares-López, Sonia Ortiz-Peregrina, Pilar Granados-Delgado, José R. Jiménez

    The purpose of this study was to assess the influence of a moderate breath–alcohol content (BrAC of 0.40 mg/L) on binocular visual performance for different visual functions after inducing different levels of interocular differences with the use of filters. A total of 26 healthy young subjects were enrolled. The participants participated in two sessions: one without alcohol consumption and another after alcohol consumption. In each session and for the different filter conditions (subjects were wearing Bangerter foil of 0.8 and BPM2 fog filter on the dominant eye), monocular and binocular visual function was evaluated by measuring visual acuity, contrast sensitivity, visual discrimination capacity (and successively by calculating their corresponding binocular summations) and stereopsis (near and distance stereoacuity). In addition, interocular differences were calculated for different retinal–image quality and straylight parameters. All monocular and binocular visual functions were analyzed and stereopsis was significantly impaired by alcohol and filters (p < 0.05). Interocular differences for different ocular parameters and binocular summations for visual parameters were negatively affected by filters but not alcohol. Significant correlations (averaging all the experimental conditions analyzed) were found, highlighting: the higher the interocular differences, the lower the binocular summation and the poorer the stereopsis and, therefore, the worse the binocular visual performance.


  • Open Access

    Effects of Smoking Cannabis on Visual Function and Driving Performance. A Driving-Simulator Based Study

    by Sonia Ortiz-Peregrina, Carolina Ortiz, José J. Castro-Torres, José R. Jiménez, Rosario G. Anera

    Cannabis is the most widely used illegal drug in the world. Limited information about the effects of cannabis on visual function is available, and more detail about the possible impact of visual effects on car driving is required. This study investigated the effects of smoking cannabis on vision and driving performance, and whether these effects are correlated. Twenty drivers and occasional users were included (mean (SE) age, 23.3 (1.0) years; five women). Vision and simulated driving performance were evaluated in a baseline session and after smoking cannabis. Under the influence of cannabis, certain visual functions such as visual acuity (p < 0.001), contrast sensitivity (p = 0.004) and stereoacuity (far, p < 0.001; near, p = 0.013) worsened. In addition, there was an overall deterioration of driving performance, with the task of keeping the vehicle in the lane proving more difficult (p < 0.05). A correlation analysis showed significant associations between driving performance and visual function. Thus, the strongest correlations were found between the distance driven onto the shoulder and stereoacuity, for near (ρ = 0.504; p = 0.001) and far distances (ρ = 0.408; p = 0.011). This study provides the first evidence to show that the visual effects of cannabis could impact driving performance, compromising driving safety. The results indicate that information and awareness campaigns are essential for reducing the incidence of driving under the influence of cannabis.


  • Open Access

    Hyperopic Q-optimized algorithms: a theoretical study on factors influencing optical quality

    by Jose R. Jiménez, Aixa Alarcón, Rosario G. Anera, L. Jiménez Del Barco

    In this work, we analyze the way in which pupil size, optical zone, and initial hyperopic level influence optical quality for hyperopic Q-optimized corneal refractive surgery. Different Q-optimized algorithms and the Munnerlyn formula were tested to analyze the optical quality of the final retinal image for initial hyperopic errors from 1D to 5D. Three optical zones (5.5, 6, and 6.5 mm) and two pupil diameters (5 and 7 mm) were considered. To evaluate optical quality, we computed the modulation transfer function (MTF) and the area under MTF (MTFa). Q-optimized values at around Q = −0.18 were found to provide the best optical quality for most of the conditions tested. This optimum final asphericity for hyperopic ablation was not depending on the degree of hyperopia corrected, the optical zone or the pupil size being this information important for clinical practice.


  • A correction factor for ablation algorithms assuming deviations of Lambert-Beer’s law with a Gaussian-profile beam

    by Francisco Rodríguez-Marín, Rosario G. Anera, Aixa Alarcón, E. Hita, J. R. Jiménez

    In this work, we propose an adjustment factor to be considered in ablation algorithms used in refractive surgery. This adjustment factor takes into account potential deviations of Lambert-Beer’s law and the characteristics of a Gaussian-profile beam. To check whether the adjustment factor deduced is significant for visual function, we applied it to the paraxial Munnerlyn formula and found that it significantly influences the post-surgical corneal radius and p-factor. The use of the adjustment factor can help reduce the discrepancies in corneal shape between the real data and corneal shape expected when applying laser ablation algorithms.


  • Night-vision tests for evaluating visual performance

    by José R. Jiménez, Rosario G. Anera, Cesar Villa, Margarita Soler

  • Visual performance after LASIK for a Q-optimized and a standard ablation algorithm

    by César Villa, José R. Jiménez, Rosario G. Anera, Ramón Gutiérrez, Enrique Hita

    We test visual performance after LASIK (laser in situ keratomileusis) for a Q-optimized ablation algorithm and one based on the Munnerlyn formula. The visual functions tested include aberrometry, monocular and binocular contrast sensitivity function (CSF), and a discrimination test under low-illumination conditions. This test is useful to quantify night-vision disturbances. A total of 102 patients took part in the ex periments, and visual data were taken before (with best correction) and after LASIK. Results show a deterioration in aberrometry, CSF, binocular summation, and discrimination index for the two algorithms tested, although this deterioration is significantly lower for the Q-optimized algorithm.


  • Optical Image Quality and Visual Performance for Patients With Keratitis

    by José R Jiménez, Carolina Ortiz, Francisco Pérez-Ocón, Raimundo Jiménez

    To evaluate the optical image quality, using 2 optical devices (an aberrometer and a double-pass device), and visual performance [contrast sensitivity function (CSF)] in patients with keratitis and after resolution of the disease. Twenty subjects with keratitis (18 patients with unilateral keratitis and 2 patients with bilateral keratitis) were included in this study. We also took measurements in healthy fellow eyes for comparison. Ten patients were studied before and after the resolution of keratitis. Objective data were gathered by aberrometry (ocular higher order, spherical, and coma aberrations) and the Strehl ratio, a parameter derived from the double-pass device that included information on diffraction, ocular aberrations, and scattering. The CSF was also measured for all the patients. Ocular higher order, spherical, and coma aberrations in keratitis eyes were significantly (P < 0.05) higher than those in healthy fellow eyes. The Strehl ratio indicates a worse optical quality for keratitis eyes being significantly (P < 0.05) lower than the Strehl ratio for healthy fellow eyes. CSF for keratitis eyes was also significantly lower than that for the healthy eyes (P < 0.05). Data for keratitis eyes after the resolution of the disease showed a significant increase in the optical function and visual performance but, after treatment, continued to suffer significant (P < 0.05) impairment in the optical quality of the affected eyes compared with the healthy fellow eyes. Devices to measure optical image quality and the CSF enable the characterization of the optical quality and visual performance in patients with keratitis, showing a significant decline in optical quality and visual performance during keratitis and an improvement after the resolution of the pathology.


  • Objective and subjective optical-quality measurements in subjects with keratitis and age-related macular degeneration

    by José R. Jiménez, Carolina Ortiz, Francisco Pérez-Ocón, José J. Castro

    The use of commercial devices that objectively measure retinal image quality has increased in recent years although limited mostly to the analysis of surgical emmetropization techniques. In this work, we propose the use of optical-quality devices (an aberrometer and a double-pass device) to be extended to other highly prevalent ocular pathologies such as keratitis and age-related macular degeneration. For this, we determined whether the objective data correlate with visual performance. Data, including the contrast-sensitivity function, were taken for 26 patients. The results show a clear correspondence between objective and psychophysical measurements, revealing that optical-quality devices can be useful for additional visual clinical applications.


  • Upper disparity limit after LASIK

    by José R. Jiménez, José J. Castro, Enrique Hita, Rosario G. Anera

    We evaluate the effect of the emmetropization technique LASIK (laser-assisted in situ keratomileusis) on stereoscopic vision. For this, we used a mirror stereoscope to measure the upper disparity limit Dmax before (with best correction) and after LASIK for 30 patients. The results show that the upper disparity limit declines from 41.1min of arc on average to 31.3min of arc after LASIK, being significant in 83% of the patients. This deterioration is significantly correlated with an increase in the postsurgical interocular differences in higher-order aberrations, corneal asphericity, and presurgical anisometropia. New ablation algorithms should minimize interocular differences in order to improve binocular visual performance.