Samir E. Bisharaa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Samir E. Bisharaa has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- John Joseph Warren
Department of Preventive and Community Dentistry, The University of Iowa, Iowa City, IA
7 shared publications Charuphan Oonsombat
4 shared publicationsRaed Ajlouni
4 shared publicationsJohn Laffoon
Research Assistants, College of Dentistry, University of Iowa, Iowa City
3 shared publicationsManal M A Soliman
3 shared publicationsJ F Laffoon
2 shared publications
Latest Publications
- 1 July 2007
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 77 (4) , 711-715
A Self-Conditioner for Resin-Modified Glass Ionomers in Bonding Orthodontic Brackets
Objective: To evaluate a new self-etch conditioner used with resin-modified glass ionomers (RMGIs) in bonding orthodontic brackets. Materials and Methods: Sixty human molars were cleaned, mounted, and randomly divided into three groups. In group 1 (control), 20 orthodontic brackets were bonded to teeth using Transbond Plus Self-etching Primer; in group 2, 20 brackets were bonded using an RMGI with a 10% polyacrylic acid conditioner. In group 3, 20 brackets were bonded using Fuji Ortho LC with a new no-rinse self-conditioner for RMGIs. The same bracket type was used on all groups. The teeth were debonded in shear mode using a universal testing machine, and the amount of residual adhesive remaining on each tooth was evaluated. Analysis of variance was used to compare the shear bond strength (SBS), and the χ2 test was used to compare the Adhesive Remnant Index (ARI) scores. Results: There were no significant differences in the SBS (P = .556) between the groups. The mean SBS for Transbond Plus was 8.6 ± 2.6 MPa, for Fuji Ortho LC using 10% polyacrylic acid 9.1 ± 4.6 MPa, and for Fuji Ortho LC using GC Self-conditioner 9.9 ± 4.1 MPa. The comparisons of the ARI scores between the three groups (χ2 = 35.5) indicated that bracket failure mode was significantly different (P < .001), with more adhesive remaining on the teeth bonded using Transbond. Conclusions: The new self-etch conditioner can be used with an RMGI to successfully bond brackets. In addition, brackets bonded with Fuji Ortho LC resulted in less residual adhesive remaining on the teeth.
- 1 July 2007
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 77 (4) , 711-715
A Self-Conditioner for Resin-Modified Glass Ionomers in Bonding Orthodontic Brackets
Objective: To evaluate a new self-etch conditioner used with resin-modified glass ionomers (RMGIs) in bonding orthodontic brackets. Materials and Methods: Sixty human molars were cleaned, mounted, and randomly divided into three groups. In group 1 (control), 20 orthodontic brackets were bonded to teeth using Transbond Plus Self-etching Primer; in group 2, 20 brackets were bonded using an RMGI with a 10% polyacrylic acid conditioner. In group 3, 20 brackets were bonded using Fuji Ortho LC with a new no-rinse self-conditioner for RMGIs. The same bracket type was used on all groups. The teeth were debonded in shear mode using a universal testing machine, and the amount of residual adhesive remaining on each tooth was evaluated. Analysis of variance was used to compare the shear bond strength (SBS), and the χ2 test was used to compare the Adhesive Remnant Index (ARI) scores. Results: There were no significant differences in the SBS (P = .556) between the groups. The mean SBS for Transbond Plus was 8.6 ± 2.6 MPa, for Fuji Ortho LC using 10% polyacrylic acid 9.1 ± 4.6 MPa, and for Fuji Ortho LC using GC Self-conditioner 9.9 ± 4.1 MPa. The comparisons of the ARI scores between the three groups (χ2 = 35.5) indicated that bracket failure mode was significantly different (P < .001), with more adhesive remaining on the teeth bonded using Transbond. Conclusions: The new self-etch conditioner can be used with an RMGI to successfully bond brackets. In addition, brackets bonded with Fuji Ortho LC resulted in less residual adhesive remaining on the teeth.
- 1 May 2005
- Published by Wiley in The Angle Orthodontist
- Vol. 75 (3) , 397-9
Effect of antimicrobial monomer-containing adhesive on shear bond strength of orthodontic brackets.
A new antibacterial and fluoride-releasing bonding system consists of a self-etching primer that contains an antibacterial monomer and a bonding agent that contains sodium fluoride. This study was to determine the effect of using this new adhesive on the shear bond strength of orthodontic brackets. Forty molar teeth were randomly divided into two groups. Group 1 consisted of 20 teeth that were etched for 15 seconds with 35% phosphoric acid, washed with a water spray for 10 seconds, and dried to a chalky white appearance, and the sealant was applied to the etched surface. The precoated brackets were placed on the teeth and light cured. Group 2 consisted of 20 teeth that were etched with 35% phosphoric acid for 15 seconds as suggested by the manufacturer when bonding to intact enamel. The teeth were washed with a water spray for 10 seconds and dried to a chalky white appearance, and the primer containing antibacterial monomer was applied to the etched surface, left for 20 seconds, and sprayed with a mild airstream. The adhesive was applied to each tooth, and the precoated bracket was placed and light cured. There were no significant differences (P = .220) in the shear bond strengths of the two groups. The mean shear bond strength for the antibacterial fluoride-releasing adhesive was 11.7 +/- 5.6 MPa and for the control was 9.6 +/- 5.0 MPa. The use of an antibacterial fluoride-releasing adhesive system did not affect the shear bond strength of the orthodontic brackets within the first half hour after initial bonding.
- 1 May 2005
- Published by Wiley in The Angle Orthodontist
- Vol. 75 (3) , 397-9
Effect of antimicrobial monomer-containing adhesive on shear bond strength of orthodontic brackets.
A new antibacterial and fluoride-releasing bonding system consists of a self-etching primer that contains an antibacterial monomer and a bonding agent that contains sodium fluoride. This study was to determine the effect of using this new adhesive on the shear bond strength of orthodontic brackets. Forty molar teeth were randomly divided into two groups. Group 1 consisted of 20 teeth that were etched for 15 seconds with 35% phosphoric acid, washed with a water spray for 10 seconds, and dried to a chalky white appearance, and the sealant was applied to the etched surface. The precoated brackets were placed on the teeth and light cured. Group 2 consisted of 20 teeth that were etched with 35% phosphoric acid for 15 seconds as suggested by the manufacturer when bonding to intact enamel. The teeth were washed with a water spray for 10 seconds and dried to a chalky white appearance, and the primer containing antibacterial monomer was applied to the etched surface, left for 20 seconds, and sprayed with a mild airstream. The adhesive was applied to each tooth, and the precoated bracket was placed and light cured. There were no significant differences (P = .220) in the shear bond strengths of the two groups. The mean shear bond strength for the antibacterial fluoride-releasing adhesive was 11.7 +/- 5.6 MPa and for the control was 9.6 +/- 5.0 MPa. The use of an antibacterial fluoride-releasing adhesive system did not affect the shear bond strength of the orthodontic brackets within the first half hour after initial bonding.
- 1 March 2005
- Published by Wiley in The Angle Orthodontist
- Vol. 75 (2) , 237-42
Comparison of bonding time and shear bond strength between a conventional and a new integrated bonding system.
Conventional adhesive systems use 3 different agents, an enamel conditioner, a primer solution, and an adhesive resin during the bonding of orthodontic brackets to enamel. A characteristic of some new bonding systems is that they combine the conditioning and priming agents into a single application as well as precoat the bracket with the adhesive in an attempt to save time during the bonding procedure. This study compared the total bonding time and shear bond strength (SBS) of 2 bracket-bonding systems: (1) an integrated system that incorporates a self-etching primer and precoated brackets and (2) a conventional system in which the etchant and primer are applied separately and the adhesive applied to the bracket by the clinician. The results of the SBS and the total bonding time comparisons (t = 3.451) of the 2 adhesive systems showed a significant difference (P = .0001). The mean SBS was 9.4+/-3.7 MPa for the new bonding system and 6.2+/-4.4 MPa for the conventional system. The mean total bonding time was 36.5 s/tooth for the new system and 46.7 s/tooth for the conventional system. The clinician has to decide whether the increase in bond strength, the decrease in the total bonding time, and the steps saved during the bonding procedure with the new bonding system balance the increased cost incurred.
- 1 March 2005
- Published by Wiley in The Angle Orthodontist
- Vol. 75 (2) , 237-42
Comparison of bonding time and shear bond strength between a conventional and a new integrated bonding system.
Conventional adhesive systems use 3 different agents, an enamel conditioner, a primer solution, and an adhesive resin during the bonding of orthodontic brackets to enamel. A characteristic of some new bonding systems is that they combine the conditioning and priming agents into a single application as well as precoat the bracket with the adhesive in an attempt to save time during the bonding procedure. This study compared the total bonding time and shear bond strength (SBS) of 2 bracket-bonding systems: (1) an integrated system that incorporates a self-etching primer and precoated brackets and (2) a conventional system in which the etchant and primer are applied separately and the adhesive applied to the bracket by the clinician. The results of the SBS and the total bonding time comparisons (t = 3.451) of the 2 adhesive systems showed a significant difference (P = .0001). The mean SBS was 9.4+/-3.7 MPa for the new bonding system and 6.2+/-4.4 MPa for the conventional system. The mean total bonding time was 36.5 s/tooth for the new system and 46.7 s/tooth for the conventional system. The clinician has to decide whether the increase in bond strength, the decrease in the total bonding time, and the steps saved during the bonding procedure with the new bonding system balance the increased cost incurred.
- 1 March 2005
- Published by Wiley in The Angle Orthodontist
- Vol. 75 (2) , 243-6
Effects of using a new protective sealant on the bond strength of orthodontic brackets.
This study determines the effect of applying a new protective sealant to the enamel surface on the shear bond strengths of orthodontic brackets. Sixty teeth were randomly divided into three groups. In group 1 (control), the brackets were bonded to the etched teeth using the regular sealant. In group 2, the sealant was replaced with Pro Seal and light cured as recommended by the manufacturer; the brackets were then placed, and the adhesive was light cured. In group 3, Pro Seal was applied, the bracket with the adhesive was placed on the tooth, and both Pro Seal and the adhesive were cured simultaneously. The purpose of this modification was to reduce one of the steps during the bonding procedure. A shear force was applied at the bracket-tooth interface using a Zwick Universal Test Machine. The results of the analysis of variance (F-ratio = 1.35) indicated that the shear bond strengths of the three groups were not significantly different (P = .267) from each other. The mean shear bond strength of the control group was 4.9+/-2.1 MPa. The mean shear bond strength for teeth coated with Pro Seal and light cured followed by application and light curing of the adhesive was 4.8+/-2.3 MPa, and the mean for the teeth coated with Pro Seal and then bracket placed followed by simultaneous light curing of the sealant and the adhesive was 4.0+/-1.5 MPa.
- 1 March 2005
- Published by Wiley in The Angle Orthodontist
- Vol. 75 (2) , 243-6
Effects of using a new protective sealant on the bond strength of orthodontic brackets.
This study determines the effect of applying a new protective sealant to the enamel surface on the shear bond strengths of orthodontic brackets. Sixty teeth were randomly divided into three groups. In group 1 (control), the brackets were bonded to the etched teeth using the regular sealant. In group 2, the sealant was replaced with Pro Seal and light cured as recommended by the manufacturer; the brackets were then placed, and the adhesive was light cured. In group 3, Pro Seal was applied, the bracket with the adhesive was placed on the tooth, and both Pro Seal and the adhesive were cured simultaneously. The purpose of this modification was to reduce one of the steps during the bonding procedure. A shear force was applied at the bracket-tooth interface using a Zwick Universal Test Machine. The results of the analysis of variance (F-ratio = 1.35) indicated that the shear bond strengths of the three groups were not significantly different (P = .267) from each other. The mean shear bond strength of the control group was 4.9+/-2.1 MPa. The mean shear bond strength for teeth coated with Pro Seal and light cured followed by application and light curing of the adhesive was 4.8+/-2.3 MPa, and the mean for the teeth coated with Pro Seal and then bracket placed followed by simultaneous light curing of the sealant and the adhesive was 4.0+/-1.5 MPa.
- 1 June 2004
- Published by Wiley in The Angle Orthodontist
- Vol. 74 (3) , 400-4
The effect of variation in mesh-base design on the shear bond strength of orthodontic brackets.
This study compared the shear bond strengths of two metallic orthodontic brackets, one with a single-mesh bracket base and the other with a double-mesh bracket base. The Transbond XT adhesive system was used to bond all brackets to the teeth. Two types of brackets were compared, ie, 20 Ovation metal bracket series, with a double-mesh base (Super-mesh) and an 81.50 gauge (0.126 inch), and 20 Victory series metal brackets that have a miniature single-mesh base. The teeth were bonded and debonded within half an hour from the initial bonding. The enamel surface was examined under 10x magnification to determine how much residual adhesive remained on the tooth. Student's t-test was used to compare the shear bond strength of the two groups. Chi-square test was used to compare the adhesive remnant index (ARI) scores for the two bracket types. The mean shear bond strength for the double-mesh brackets was 5.2 +/- 3.9 MPa and for the single-mesh brackets was 5.8 +/- 2.8 MPa. The t-test comparisons indicated that they were not significantly different from each other (P = .157). The ARI comparisons indicated that both bracket types had similar bracket failure modes and were not significantly different from each other (chi2 = 2.0, P = .5). These results indicated that single- and double-mesh bracket bases have comparable shear bond strength and bracket failure modes.
- 1 June 2004
- Published by Wiley in The Angle Orthodontist
- Vol. 74 (3) , 400-4
The effect of variation in mesh-base design on the shear bond strength of orthodontic brackets.
This study compared the shear bond strengths of two metallic orthodontic brackets, one with a single-mesh bracket base and the other with a double-mesh bracket base. The Transbond XT adhesive system was used to bond all brackets to the teeth. Two types of brackets were compared, ie, 20 Ovation metal bracket series, with a double-mesh base (Super-mesh) and an 81.50 gauge (0.126 inch), and 20 Victory series metal brackets that have a miniature single-mesh base. The teeth were bonded and debonded within half an hour from the initial bonding. The enamel surface was examined under 10x magnification to determine how much residual adhesive remained on the tooth. Student's t-test was used to compare the shear bond strength of the two groups. Chi-square test was used to compare the adhesive remnant index (ARI) scores for the two bracket types. The mean shear bond strength for the double-mesh brackets was 5.2 +/- 3.9 MPa and for the single-mesh brackets was 5.8 +/- 2.8 MPa. The t-test comparisons indicated that they were not significantly different from each other (P = .157). The ARI comparisons indicated that both bracket types had similar bracket failure modes and were not significantly different from each other (chi2 = 2.0, P = .5). These results indicated that single- and double-mesh bracket bases have comparable shear bond strength and bracket failure modes.
- 1 August 2003
- Published by Wiley in The Angle Orthodontist
- Vol. 73 (4) , 431-5
Evaluation of a new curing light on the shear bond strength of orthodontic brackets.
With the introduction of photosensitive (light-cured) restorative materials in dentistry, various methods were suggested to enhance their polymerization and to shorten the curing time including layering and the use of more powerful light-curing devices. The purpose of this study was to determine the effect of using a new light-curing apparatus that uses a light-emitting diode (LED) on the shear bond strength of an orthodontic adhesive. The new light-curing apparatus used in the study was UltraLume 2 (Ultradent USA, South Jordan, Utah) that has an 8-mm footprint and can simultaneously cure two orthodontic brackets. Forty teeth were etched with 37% phosphoric acid, washed and dried, and sealant applied, and then precoated brackets with the Transbond adhesive (APC II, 3M Unitek, Monrovia, Calif) were placed. The teeth were randomly divided into two groups according to the curing light used. In group I (control), 20 brackets were cured using an Ortholux (3M Unitek) halogen curing light for 20 seconds. In group II, 20 brackets were cured using the new LED light for 20 seconds. The findings indicated no significant (P = .343) differences in the shear bond strength between the Ortholux halogen light (5.1 +/- 2.5 MPa) and the UltraLume 2 LED light when the two groups were compared using Student's t-test (t = -0.961). In conclusion, the advantages of the new unit include the ability to cure two brackets at a time and a smaller light-emitting apparatus for the clinician to handle.
- 1 August 2003
- Published by Wiley in The Angle Orthodontist
- Vol. 73 (4) , 431-5
Evaluation of a new curing light on the shear bond strength of orthodontic brackets.
With the introduction of photosensitive (light-cured) restorative materials in dentistry, various methods were suggested to enhance their polymerization and to shorten the curing time including layering and the use of more powerful light-curing devices. The purpose of this study was to determine the effect of using a new light-curing apparatus that uses a light-emitting diode (LED) on the shear bond strength of an orthodontic adhesive. The new light-curing apparatus used in the study was UltraLume 2 (Ultradent USA, South Jordan, Utah) that has an 8-mm footprint and can simultaneously cure two orthodontic brackets. Forty teeth were etched with 37% phosphoric acid, washed and dried, and sealant applied, and then precoated brackets with the Transbond adhesive (APC II, 3M Unitek, Monrovia, Calif) were placed. The teeth were randomly divided into two groups according to the curing light used. In group I (control), 20 brackets were cured using an Ortholux (3M Unitek) halogen curing light for 20 seconds. In group II, 20 brackets were cured using the new LED light for 20 seconds. The findings indicated no significant (P = .343) differences in the shear bond strength between the Ortholux halogen light (5.1 +/- 2.5 MPa) and the UltraLume 2 LED light when the two groups were compared using Student's t-test (t = -0.961). In conclusion, the advantages of the new unit include the ability to cure two brackets at a time and a smaller light-emitting apparatus for the clinician to handle.
- 1 October 2002
- Published by Wiley in The Angle Orthodontist
- Vol. 72 (5) , 464-7
Effects of modifying the adhesive composition on the bond strength of orthodontic brackets.
In an attempt to save chair time during bonding, metal brackets have been precoated with the adhesive material. Although the adhesive used on the precoated brackets is basically similar in composition to that used for bonding uncoated brackets, there are differences in the percentages of the various ingredients incorporated in the material. These changes are intended to enhance specific clinical properties. The purpose of this study was to determine whether modifications in the composition of the adhesives, used on precoated and uncoated metal brackets, affect their shear bond strengths during the first half hour after bonding. This is the time span when the initial arch wires are ligated. Sixty freshly extracted human molars were bonded with three different compositions of the same basic adhesive. The teeth were mounted in phenolic rings. An occlusogingival load was applied to the brackets producing a shear force at the bracket-tooth interface utilizing a Zwick Universal Test Machine. Analysis of variance was used to compare the three adhesives. Significance was predetermined at < or =.05 level of confidence. The present findings indicated that the shear bond strengths of the various modifications of the adhesive used on two different precoated metal brackets were not significantly different (F-ratio = .729 and P = .407) from those obtained with the conventional adhesive used on uncoated brackets. The mean values for the shear bond strengths of the two precoated brackets were: APC = 5.1+/-1.7 MPa and APC II = 4.9+/-2.1 MPa. The shear bond strength for the conventional adhesive used on the uncoated brackets was = 5.7+/-2.4 MPa. All bracket/adhesive combinations tested provided clinically acceptable shear bond forces within the first 30 minutes after initial bonding.
- 1 October 2002
- Published by Wiley in The Angle Orthodontist
- Vol. 72 (5) , 464-7
Effects of modifying the adhesive composition on the bond strength of orthodontic brackets.
In an attempt to save chair time during bonding, metal brackets have been precoated with the adhesive material. Although the adhesive used on the precoated brackets is basically similar in composition to that used for bonding uncoated brackets, there are differences in the percentages of the various ingredients incorporated in the material. These changes are intended to enhance specific clinical properties. The purpose of this study was to determine whether modifications in the composition of the adhesives, used on precoated and uncoated metal brackets, affect their shear bond strengths during the first half hour after bonding. This is the time span when the initial arch wires are ligated. Sixty freshly extracted human molars were bonded with three different compositions of the same basic adhesive. The teeth were mounted in phenolic rings. An occlusogingival load was applied to the brackets producing a shear force at the bracket-tooth interface utilizing a Zwick Universal Test Machine. Analysis of variance was used to compare the three adhesives. Significance was predetermined at < or =.05 level of confidence. The present findings indicated that the shear bond strengths of the various modifications of the adhesive used on two different precoated metal brackets were not significantly different (F-ratio = .729 and P = .407) from those obtained with the conventional adhesive used on uncoated brackets. The mean values for the shear bond strengths of the two precoated brackets were: APC = 5.1+/-1.7 MPa and APC II = 4.9+/-2.1 MPa. The shear bond strength for the conventional adhesive used on the uncoated brackets was = 5.7+/-2.4 MPa. All bracket/adhesive combinations tested provided clinically acceptable shear bond forces within the first 30 minutes after initial bonding.
- 1 December 2001
- Published by Wiley
- Vol. 71 (6) , 461-5
Evaluation of nonrinse conditioning solution and a compomer as an alternative method of bonding orthodontic bracket.
Damage to the enamel surface during bonding and debonding of orthodontic brackets is a clinical concern. Alternative bonding methods that minimize enamel surface damage while maintaining a clinically useful bond strength are an aim of current research. The purpose of this study was to compare the effects of using two enamel conditioners and adhesives on the shear bond strength and bracket failure location. Forty freshly extracted human molars were pumiced and randomly divided into two groups of 20 teeth. Metal orthodontic brackets were bonded to the enamel surface by one of two protocols: 37% phosphoric acid with a composite adhesive (Transbond XT) or a nonrinse conditioner with a compomer adhesive (Dyract flow). The teeth were mounted in phenolic rings and stored in deionized water at 37 degrees C for 24 hours. A Zwick Universal Testing Machine was used to determine shear bond strengths in MegaPascals. The residual adhesive on the enamel surface was evaluated using the Adhesive Remnant Index. Student t-test and chi2-test were used to compare the two groups. Significance was predetermined at P < or = .05. The results of the t-tests indicated that there were significant differences between the two adhesive systems (t = 11.18 and P = .001) with the nonrinse conditioner/compomer system having lower shear bond strength (X = 1.7 +/- 0.9 MPa) than the phosphoric acid/composite adhesive (X = 10.4 +/- 2.8 MPa). The results of the Chi Square test evaluating the residual adhesives on the enamel surfaces also revealed significant differences between the two groups (chi2 = 7.62, P = .022). In conclusion, a nonrinse conditioner used with a compomer adhesive had significantly lower shear bond strength than a phosphoric acid/composite adhesive system.
- 1 December 2001
- Published by Wiley
- Vol. 71 (6) , 461-5
Evaluation of nonrinse conditioning solution and a compomer as an alternative method of bonding orthodontic bracket.
Damage to the enamel surface during bonding and debonding of orthodontic brackets is a clinical concern. Alternative bonding methods that minimize enamel surface damage while maintaining a clinically useful bond strength are an aim of current research. The purpose of this study was to compare the effects of using two enamel conditioners and adhesives on the shear bond strength and bracket failure location. Forty freshly extracted human molars were pumiced and randomly divided into two groups of 20 teeth. Metal orthodontic brackets were bonded to the enamel surface by one of two protocols: 37% phosphoric acid with a composite adhesive (Transbond XT) or a nonrinse conditioner with a compomer adhesive (Dyract flow). The teeth were mounted in phenolic rings and stored in deionized water at 37 degrees C for 24 hours. A Zwick Universal Testing Machine was used to determine shear bond strengths in MegaPascals. The residual adhesive on the enamel surface was evaluated using the Adhesive Remnant Index. Student t-test and chi2-test were used to compare the two groups. Significance was predetermined at P < or = .05. The results of the t-tests indicated that there were significant differences between the two adhesive systems (t = 11.18 and P = .001) with the nonrinse conditioner/compomer system having lower shear bond strength (X = 1.7 +/- 0.9 MPa) than the phosphoric acid/composite adhesive (X = 10.4 +/- 2.8 MPa). The results of the Chi Square test evaluating the residual adhesives on the enamel surfaces also revealed significant differences between the two groups (chi2 = 7.62, P = .022). In conclusion, a nonrinse conditioner used with a compomer adhesive had significantly lower shear bond strength than a phosphoric acid/composite adhesive system.
- 1 December 2001
- Published by Wiley
- Vol. 71 (6) , 466-9
Effect of using a new cyanoacrylate adhesive on the shear bond strength of orthodontic brackets.
During bonding of orthodontic brackets to enamel, conventional adhesive systems use three different agents: an enamel conditioner, a primer solution, and an adhesive resin. A unique characteristic of some new bonding systems is that they need neither a priming agent nor a curing light to bond brackets. Such an approach should be more cost-effective for the clinician and indirectly also for the patient. The purpose of this study was to determine the effects of using a cyanoacrylate adhesive on the shear bond strength of orthodontic brackets and on the bracket/adhesive failure mode. The brackets were bonded to extracted human teeth according to one of two protocols. Group 1: Teeth were etched with 37% phosphoric acid. After applying the primer, the brackets were bonded with Transbond XT (3M Unitek, Monrovia, Calif) and were light-cured for 20 seconds. Group 2: Teeth were etched with 35% phosphoric acid. The brackets were then bonded with Smartbond (Gestenco International, Göthenburg, Sweden). The present in vitro findings indicated that the use of the cyanoacrylate adhesive to bond orthodontic brackets to the enamel surface did not result in a significantly different (P = .24) shear bond force (mean = 5.8 +/- 2.4 MPa) as compared to the control group (mean = 5.2 +/- 2.9 MPa). The comparison of the Adhesive Remnant Index scores indicated that there was significantly (P = .006) less residual adhesive remaining on the tooth with the cyanoacrylate than on the tooth with the conventional adhesive system. In conclusion, the new adhesive has the potential to be used to bond orthodontic brackets while reducing the total bonding time.
- 1 December 2001
- Published by Wiley
- Vol. 71 (6) , 466-9
Effect of using a new cyanoacrylate adhesive on the shear bond strength of orthodontic brackets.
During bonding of orthodontic brackets to enamel, conventional adhesive systems use three different agents: an enamel conditioner, a primer solution, and an adhesive resin. A unique characteristic of some new bonding systems is that they need neither a priming agent nor a curing light to bond brackets. Such an approach should be more cost-effective for the clinician and indirectly also for the patient. The purpose of this study was to determine the effects of using a cyanoacrylate adhesive on the shear bond strength of orthodontic brackets and on the bracket/adhesive failure mode. The brackets were bonded to extracted human teeth according to one of two protocols. Group 1: Teeth were etched with 37% phosphoric acid. After applying the primer, the brackets were bonded with Transbond XT (3M Unitek, Monrovia, Calif) and were light-cured for 20 seconds. Group 2: Teeth were etched with 35% phosphoric acid. The brackets were then bonded with Smartbond (Gestenco International, Göthenburg, Sweden). The present in vitro findings indicated that the use of the cyanoacrylate adhesive to bond orthodontic brackets to the enamel surface did not result in a significantly different (P = .24) shear bond force (mean = 5.8 +/- 2.4 MPa) as compared to the control group (mean = 5.2 +/- 2.9 MPa). The comparison of the Adhesive Remnant Index scores indicated that there was significantly (P = .006) less residual adhesive remaining on the tooth with the cyanoacrylate than on the tooth with the conventional adhesive system. In conclusion, the new adhesive has the potential to be used to bond orthodontic brackets while reducing the total bonding time.
- 1 May 2000
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 117 (5) , 595-597
Ceramic brackets and the need to develop national standards
- 1 May 2000
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 117 (5) , 595-597
Ceramic brackets and the need to develop national standards