AFA. Hunter Fanney

A. Hunter Fanney

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


A. Hunter Fanney has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Brian P. Dougherty

    National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899-8632

    1 shared publication
  • Brian P. Dougherty

    Mem. ASME National Institute of Standards and Technology, 100 Bureau Drive, Stop 8632, Gaithersburg, MD 20899-8632

    1 shared publication
  • David L. King

    Sandia National Laboratories, PO Box 5800, MS 1033, Albuquerque, NM 87185-1033

    1 shared publication
  • Jay A. Kratochvil

    Sandia National Laboratories, PO Box 5800, MS 1033, Albuquerque, NM 87185-1033

    1 shared publication
  • Mark W. Davis

    National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899-8632

    1 shared publication
  • Mark W. Davis

    National Institute of Standards and Technology, Heat Transfer and Alternative Energy Systems Group, Gaithersburg, MD 20899-8632

    1 shared publication

Latest Publications

  • Comparison of Photovoltaic Module Performance Measurements

    by A. Hunter Fanney, Mark W. Davis, Brian P. Dougherty, David L. King, William E. Boyson, Jay A. Kratochvil

    Computer simulation tools used to predict the energy production of photovoltaic systems are needed in order to make informed economic decisions. These tools require input parameters that characterize module performance under various operational and environmental conditions. Depending upon the complexity of the simulation model, the required input parameters can vary from the limited information found on labels affixed to photovoltaic modules to an extensive set of parameters. The required input parameters are normally obtained indoors using a solar simulator or flash tester, or measured outdoors under natural sunlight. This paper compares measured performance parameters for three photovoltaic modules tested outdoors at the National Institute of Standards and Technology (NIST) and Sandia National Laboratories (SNL). Two of the three modules were custom fabricated using monocrystalline and silicon film cells. The third, a commercially available module, utilized triple-junction amorphous silicon cells. The resulting data allow a comparison to be made between performance parameters measured at two laboratories with differing geographical locations and apparatus. This paper describes the apparatus used to collect the experimental data, test procedures utilized, and resulting performance parameters for each of the three modules. Using a computer simulation model, the impact that differences in measured parameters have on predicted energy production is quantified. Data presented for each module includes power output at standard rating conditions and the influence of incident angle, air mass, and module temperature on each module’s electrical performance. Measurements from the two laboratories are in excellent agreement. The power at standard rating conditions is within 1% for all three modules. Although the magnitude of the individual temperature coefficients varied as much as 17% between the two laboratories, the impact on predicted performance at various temperature levels was minimal, less than 2%. The influence of air mass on the performance of the three modules measured at the laboratories was in excellent agreement. The largest difference in measured results between the two laboratories was noted in the response of the modules to incident angles that exceed 75deg.


  • Measured Performance of Building Integrated Photovoltaic Panels—Round 2

    by Brian P. Dougherty, A. Hunter Fanney, Mark W. Davis

    Architects, building designers, and building owners presently lack sufficient resources for thoroughly evaluating the economic impact of building integrated photovoltaics (BIPV). The National Institute of Standards and Technology (NIST) is addressing this deficiency by evaluating computer models used to predict the electrical performance of BIPV components. To facilitate this evaluation, NIST is collecting long-term BIPV performance data that can be compared against predicted values. The long-term data, in addition, provides insight into the relative merits of different building integrated applications, helps to identify performance differences between cell technologies, and reveals seasonal variations. This paper adds to the slowly growing database of long-term performance data on BIPV components. Results from monitoring eight different building-integrated panels over a 12-month period are summarized. The panels are installed vertically, face true south, and are an integral part of the building’s shell. The eight panels comprise the second set of panels evaluated at the NIST test facility. Cell technologies evaluated as part of this second round of testing include single-crystalline silicon, polycrystalline silicon, and two thin film materials: tandem-junction amorphous silicon (2-a-Si) and copper-indium-diselenide (CIS). Two 2-a-Si panels and two CIS panels were monitored. For each pair of BIPV panels, one was insulated on its back side while the back side of the second panel was open to the indoor conditioned space. The panel with the back side thermal insulation experienced higher midday operating temperatures. The higher operating temperatures caused a greater dip in maximum power voltage. The maximum power current increased slightly for the 2-a-Si panel but remained virtually unchanged for the CIS panel. Three of the remaining four test specimens were custom-made panels having the same polycrystalline solar cells but different glazings. Two different polymer materials were tested along with 6 mm-thick, low-iron float glass. The two panels having the much thinner polymer front covers consistently outperformed the panel having the glass front. When compared on an annual basis, the energy production of each polymer-front panel was 8.5% higher than the glass-front panel. Comparison of panels of the same cell technology and comparisons between panels of different cell technologies are made on daily, monthly, and annual bases. Efficiency based on coverage area, which excludes the panel’s inactive border, is used for most “between” panel comparisons. Annual coverage-area conversion efficiencies for the vertically-installed BIPV panels range from a low of 4.6% for the 2-a-Si panels to a high of 12.2% for the two polycrystalline panels having the polymer front covers. The insulated single crystalline panel only slightly outperformed the insulated CIS panel, 10.1% versus 9.7%.