Zhiqing Xun
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhiqing Xun has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Xindong Guo
Guangzhou Quality Supervision and Testing Institute, Guangzhou, P. R. China
4 shared publicationsSenyu Lin
Guangzhou Quality Supervision and Testing Institute, Guangzhou, P. R. China
3 shared publicationsYanping Xian
Guangzhou Quality Supervision and Testing Institute, Guangzhou, P. R. China
3 shared publicationsJinfeng Huang
Guangzhou Quality Supervision and Testing Institute, Guangzhou, P. R. China
2 shared publicationsShuang He
National Centre for Quality Supervision and Testing of Processed Food (Guangzhou), Guangzhou Quality Supervision and Testing Institute, Guangzhou, China
2 shared publicationsDonghong Liu
National Centre for Quality Supervision and Testing of Processed Food (Guangzhou), Guangzhou Quality Supervision and Testing Institute, Guangzhou, China
1 shared publication
Latest Publications
- 23 April 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (11) , 2354-2359
Simultaneous determination of glycol ethers and their acetates in cosmetics by gas chromatography with mass spectrometry
A gas chromatography with mass spectrometry method was developed for the simultaneous determination of ten kinds of glycol ethers and their acetates in cosmetics. The samples were extracted with methanol/ethyl acetate (80:20, v/v), further treated with vortex and ultrasound, and analyzed by gas chromatography with mass spectrometry. The concentration of each analyte was calibrated by external standard method. Under the optimal conditions, the analytes showed linear relationship in the range of 0.05–25 mg·L−1 with determination coefficients larger than 0.9987. The limits of detection and quantification were in the range of 0.09–0.59 and 0.31–1.95 mg·kg−1, respectively. The average recoveries of three spiked levels were 80.2–105.4% with the intraday and interday precisions of 1.1–6.3 and 1.9–6.5%, respectively. Method validation from different labs confirmed the satisfactory recoveries and precisions. This method shows advantages of simple, high sensitivity and high recovery, which can be applied to the detection of glycol ethers and acetates in cosmetics. This article is protected by copyright. All rights reserved
- 23 April 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (11) , 2354-2359
Simultaneous determination of glycol ethers and their acetates in cosmetics by gas chromatography with mass spectrometry
A gas chromatography with mass spectrometry method was developed for the simultaneous determination of ten kinds of glycol ethers and their acetates in cosmetics. The samples were extracted with methanol/ethyl acetate (80:20, v/v), further treated with vortex and ultrasound, and analyzed by gas chromatography with mass spectrometry. The concentration of each analyte was calibrated by external standard method. Under the optimal conditions, the analytes showed linear relationship in the range of 0.05–25 mg·L−1 with determination coefficients larger than 0.9987. The limits of detection and quantification were in the range of 0.09–0.59 and 0.31–1.95 mg·kg−1, respectively. The average recoveries of three spiked levels were 80.2–105.4% with the intraday and interday precisions of 1.1–6.3 and 1.9–6.5%, respectively. Method validation from different labs confirmed the satisfactory recoveries and precisions. This method shows advantages of simple, high sensitivity and high recovery, which can be applied to the detection of glycol ethers and acetates in cosmetics. This article is protected by copyright. All rights reserved
- 19 April 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (9) , 1966-1973
Simultaneous determination of eight alkaloids and oleandrin in herbal cosmetics by dispersive solid‐phase extraction coupled with ultra high performance liquid chromatography and tandem mass spectrometry
We utilized ultra‐high performance liquid chromatography with tandem mass spectrometry and dispersive solid‐phase extraction to develop a new method for the detection of nine analytes (scopolamine, cephaeline, strychnine, hyoscyamine, brucine, hydrastine, ajmalicine, colchicine, and oleandrin) in herbal cosmetics. Acetonitrile/water and 2‐propylaminoethylamine were used to disperse and purify during the dispersive solid‐phase extraction step. The analytes were separated by a Waters UPLC HSS T3 column and detected through electrospray ionization source in the positive mode with multi‐reaction monitoring conditions. Under the optimal conditions, the calibration curves were linear in the range of 0.2–100.0 μg/L with the correlation coefficients higher than 0.995. The method limit of quantitation (S/N = 10) were 5.0 μg/kg for oleandrin and 1.0 μg/kg for the other eight alkaloids. The mean recoveries at three spiked concentration levels of 1.0–10.0 μg/kg were in the range of 86.9–116.5% with the intra‐day relative standard deviations (n = 6) ranging from 2.4 to 8.8%, and inter‐day relative standard deviations ranging from 2.7 to 5.7%. This method is accurate, simple and rapid, and has been applied to the quality supervision of herbal cosmetics in Guangzhou.
- 19 April 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (9) , 1966-1973
Simultaneous determination of eight alkaloids and oleandrin in herbal cosmetics by dispersive solid‐phase extraction coupled with ultra high performance liquid chromatography and tandem mass spectrometry
We utilized ultra‐high performance liquid chromatography with tandem mass spectrometry and dispersive solid‐phase extraction to develop a new method for the detection of nine analytes (scopolamine, cephaeline, strychnine, hyoscyamine, brucine, hydrastine, ajmalicine, colchicine, and oleandrin) in herbal cosmetics. Acetonitrile/water and 2‐propylaminoethylamine were used to disperse and purify during the dispersive solid‐phase extraction step. The analytes were separated by a Waters UPLC HSS T3 column and detected through electrospray ionization source in the positive mode with multi‐reaction monitoring conditions. Under the optimal conditions, the calibration curves were linear in the range of 0.2–100.0 μg/L with the correlation coefficients higher than 0.995. The method limit of quantitation (S/N = 10) were 5.0 μg/kg for oleandrin and 1.0 μg/kg for the other eight alkaloids. The mean recoveries at three spiked concentration levels of 1.0–10.0 μg/kg were in the range of 86.9–116.5% with the intra‐day relative standard deviations (n = 6) ranging from 2.4 to 8.8%, and inter‐day relative standard deviations ranging from 2.7 to 5.7%. This method is accurate, simple and rapid, and has been applied to the quality supervision of herbal cosmetics in Guangzhou.
- 21 March 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (8) , 1718-1723
Simultaneous determination of seven nitrogen‐containing phenyl ethers in cosmetics by gas chromatography with mass spectrometry and dispersive solid‐phase extraction
An analytical method was established for the simultaneous determination of seven nitrogen‐containing phenyl ethers (2‐anisidine, 3‐anisidine, 4‐anisidine, 2‐nitroanisole, 3‐nitroanisole, 4‐nitroanisole, and 3,3'‐dimethoxybenzidine) in cosmetics by gas chromatography with mass spectrometry in this work. The samples were extracted with ethyl acetate and purified with primary secondary amine during the dispersed solid‐phase extraction. The analytes were separated by a DB‐17MS column and detected in the electron ionization mode of mass spectrometry in the selected ions monitoring mode. The extraction solvent, purification adsorbents, and chromatographic column behavior were optimized. The results indicated that the seven analytes show good linear relationship (R2 > 0.9965) in the concentrations of 5.0–5000 μg/L. The quantitation limits of the method ranged from 19.0 to 84.8 μg/kg. The recovery rates of seven analytes were in the range of 72.6–114% with the relative standard deviations of 1.1–7.5%. Real sample analyses showed that this accurate and precise method could be appropriate for simultaneous determination of seven nitrogen‐containing phenyl ethers in cosmetics.
- 21 March 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (8) , 1718-1723
Simultaneous determination of seven nitrogen‐containing phenyl ethers in cosmetics by gas chromatography with mass spectrometry and dispersive solid‐phase extraction
An analytical method was established for the simultaneous determination of seven nitrogen‐containing phenyl ethers (2‐anisidine, 3‐anisidine, 4‐anisidine, 2‐nitroanisole, 3‐nitroanisole, 4‐nitroanisole, and 3,3'‐dimethoxybenzidine) in cosmetics by gas chromatography with mass spectrometry in this work. The samples were extracted with ethyl acetate and purified with primary secondary amine during the dispersed solid‐phase extraction. The analytes were separated by a DB‐17MS column and detected in the electron ionization mode of mass spectrometry in the selected ions monitoring mode. The extraction solvent, purification adsorbents, and chromatographic column behavior were optimized. The results indicated that the seven analytes show good linear relationship (R2 > 0.9965) in the concentrations of 5.0–5000 μg/L. The quantitation limits of the method ranged from 19.0 to 84.8 μg/kg. The recovery rates of seven analytes were in the range of 72.6–114% with the relative standard deviations of 1.1–7.5%. Real sample analyses showed that this accurate and precise method could be appropriate for simultaneous determination of seven nitrogen‐containing phenyl ethers in cosmetics.
- 3 May 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (19) , 3953-3958
Simultaneous determination of seven acrylates in food contact paper products by GC/MS and modified QuEChERS
A new method was established to determine acrylates in food contact paper products by utilizing modified QuEChERS technology and GC/MS.
- 3 May 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (19) , 3953-3958
Simultaneous determination of seven acrylates in food contact paper products by GC/MS and modified QuEChERS
A new method was established to determine acrylates in food contact paper products by utilizing modified QuEChERS technology and GC/MS.