JLJie Lin

Jie Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jie Lin has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Zhiqiang Zheng

    Department of VIP Dental Service, Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, People’s Republic of China

    8 shared publications
  • Zhiqiang Zheng

    Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, PR China

    5 shared publications
  • Ruizhen Chen

    Department of VIP Dental Service, Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, People’s Republic of China

    4 shared publications
  • Yao Chen

    Clinical Research Center for Oral Tissue Deficiency Diseases of Fujian Province & Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China

    4 shared publications
  • Pingping Cai

    Fujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, China

    3 shared publications
  • Zhenxiang Lin

    Department of Stomatology, Hospital of Fujian Provincial Authorities, Fuzhou, People’s Republic of China

    3 shared publications

Latest Publications

  • Open Access

    Accuracy of a Three-Dimensionally Printed Dual-Guide System for Posterior Table-Top Tooth Preparation: An In Vitro Randomized Paired Study

    by Zhenxiang Lin, James Kit-Hon Tsoi, Sensen Chen, Jie Lin

    Background/Objectives: In posterior table-top (occlusal veneer) preparations, a uniform, anatomy-following reduction of about 2 mm is difficult to control freehand. This in vitro study compared a three-dimensionally (3D) printed dual-guide system that programs a cross-hatched depth-groove grid with the conventional freehand depth-groove technique. Methods: Thirteen pairs of extracted mandibular molars were mounted in dental models; within each model, one tooth was randomly assigned to guided and the other to freehand preparation, with an individual reference table-top preparation (2.0 mm reduction, 1.0 mm chamfer) designed for both. Two printed guides with four mesiodistal and four buccolingual 1.2 mm slots oriented a 1.2 mm spherical bur limited to 5.0 mm penetration by a zirconia stop; control teeth received three to four freehand grooves. Superimposition of post-preparation scans onto the reference preparations yielded signed (bias) and root mean square (RMS) 3D deviations and 2D deviations at four sections, analysed with paired tests and repeated-measures ANOVA. Results: The guided group had a lower RMS deviation (293.0 ± 113.6 vs. 448.1 ± 179.1 µm; p = 0.040) and a bias in the opposite direction (+113.4 ± 216.5 vs. −227.7 ± 268.9 µm; p = 0.001): guided preparations under-reduced, freehand preparations over-reduced, with an approximately twofold deeper peak of over-reduction in the freehand group (−1217 ± 201 vs. −630 ± 321 µm; p < 0.001). Section position changed the magnitude but not the direction of the difference (interaction p = 0.004). Conclusions: The guide reduced the magnitude of the deviation and converted a largely non-correctable over-reduction into a correctable one; because it controls the depth rather than the path of the bur, peripheral blending remains freehand.

  • Effect of different onlay materials and resin core thickness on stress distribution in partial coverage restorations: a 3D finite element study

    by Sensen Chen, Yao Chen, Sifan Chen, Changan Chen, Jie Lin

    Objective To investigate the effects of onlay materials and resin core thickness on stress distribution in partial coverage restorations under static and thermal loading using finite element analysis (FEA). Methods A 3D mandibular first molar model was created from CBCT data. Four materials (zirconia, lithium disilicate [LD], polymer-infiltrated ceramic network [PICN], gold alloy [GA]) and five resin core thicknesses (1 mm to 4 mm, plus full crown control) were tested. A total of 20 models were loaded with 100 N occlusal force and thermal stresses (5–37 °C and 37–55 °C). The distribution characteristics of the maximum principal stress (MPS) were analyzed for different combinations of variables. Results Under mechanical loading, thin resin cores (1–2 mm) performed best. Increasing thickness to 3 mm sharply raised enamel stress (zirconia: 77.35–80.72 MPa); at 4 mm, restoration stress peaked (zirconia: 150.12 MPa). Zirconia showed highest restoration stress (54.01-150.12 MPa) but lowest dentin stress (5.02–7.70 MPa); PICN had low and most stable restoration stress (55–91 MPa) but highest dentin stress (8–13 MPa). Under high-temperature thermal stress, enamel stress jumped sharply at ≥ 3 mm resin thickness, markedly higher than under low-temperature stress. GA with an extremely thin resin core (1R4O) caused abnormally high dentin stress (50.83 MPa) at low temperature. Conclusion A thin resin core (1–2 mm) offered better overall mechanical performance. Material type markedly influenced stress distribution. High-temperature thermal stress posed a greater threat to tooth structure than low-temperature stress. Thermal stress barely affected periapical/periodontal tissues. Clinical relevance For extensive MOD restorations, a 2 mm resin core is recommended as the safe threshold. Material selection should balance the protection of the restoration itself and the stress transfer to the tooth structure.

  • Open Access

    Er YAG laser debonding of zirconia restorations from titanium abutments depends on cement type water content and thickness

    by Ruizhen Chen, Yao Chen, Xing Jiang, Zhiqiang Zheng, Jie Lin

    This study investigated the influence of cement type and water content on Er: YAG laser debonding efficiency and residual bond strength between zirconia restorations and titanium abutments with varying zirconia thicknesses. One hundred and sixty titanium-zirconia specimens were fabricated with zirconia thicknesses of 1 mm, 2 mm, and 3 mm. Specimens were divided into four groups (n = 40 per group) based on cement type: glass ionomer cement (Ketac Cem Easymix, KCE), modified glass ionomer (KCE with 35 µL water, KCEW), resin cement (Clearfil SA Luting, CSAL), and modified resin cement (CSAL with 35 µL water, CSALW). Each group was further subdivided by zirconia thickness (n = 10 per subgroup). After 48 h of storage at 100% relative humidity, Er: YAG laser irradiation (2940 nm) was applied for debonding, with the debonding time recorded. Specimens not debonded within 2 min underwent shear bond strength testing. A non laser irradiated 2 mm zirconia group served as the control. Statistical analysis employed Kruskal-Wallis and Wilcoxon tests with Bonferroni correction. Interfacial morphology was examined using scanning electron microscopy (SEM). The KCE and KCEW groups demonstrated significantly higher debonding rates at 1 mm and 2 mm thicknesses (> 50%), while the CSAL and CSALW groups showed minimal debonding(< 40%), particularly at 3 mm. The Kruskal-Wallis test indicated significant variations in both debonding time (χ² = 72.9, p < 0.001) and shear bond strength (χ² =107.8, p < 0.001) across groups. Debonding time varied significantly among groups, with the shortest times observed for KCE/KCEW at thinner thicknesses. Residual bond strength was comparable among KCE, KCEW, and CSALW groups; however, CSAL at 1 mm and 2 mm exhibited significantly lower strength versus 3 mm and control (p < 0.01). SEM analysis revealed microstructural alterations at zirconia-cement interfaces post-irradiation. Cement type, water content and restoration thickness significantly influence the debonding efficiency of zirconia crowns on titanium abutments using Er: YAG laser. Specifically, glass ionomer cements facilitate more efficient debonding, whereas for resin cements, water modification introduces a trade-off between bond strength and debonding performance. Debonding efficiency decreases substantially as restoration thickness increases. Clinically, these parameters are essential for optimizing the feasibility of laser-assisted crown retrieval.

  • Open Access

    The impact of preparation dimensions and material choice on stress distribution in MOD inlays: a 3D finite element study

    by Sensen Chen, Ruizhen Chen, Yao Chen, Zhiqiang Zheng, Jie Lin

    To explore the influence of different inlay materials, depth, and width variations on stress distribution using the finite element method, and to provide a


  • Open Access

    Evaluation of the accuracy of direct digital impressions versus conventional silicone impressions for post-and-core with different root space diameters: a preliminary study in vitro

    by Jiyuan Shen, Sifan Chen, Ruizhen Chen, Zhiqiang Zheng, Jie Lin

    With the rapid advancement of digital technologies, digital intraoral scanning offers potential advantages for post-and-core impressions. However, its accu


  • Open Access

    A Biomimetic Adhesive Approach for Restoring a Cracked Tooth in a Single Visit: A Case Report

    by Zhenxiang Lin, Minrui Xu, Ruizhen Chen, Jie Lin

    Objective: This report evaluates the morphology‐driven preparation technique (MDPT) for biomimetic restoration of a cracked maxillary first molar, focusing on its tooth‐preserving benefits and clinical outcomes. Case Presentation: A 36‐year‐old male presented with 2 months of masticatory pain and recent spontaneous pain in the upper right posterior region (Tooth 16). Examination revealed occlusal cracks, confirmed as cracked tooth syndrome radiographically. Treatment included microscopic root canal therapy (biomechanical preparation, irrigation, and hybrid obturation) followed by MDPT‐based restoration. The minimally invasive approach preserved natural morphology using digital impressions (3Shape TRIOS 5) and placed a lithium disilicate veneer with dual‐cure resin cement under optimized bonding protocols. Results: MDPT achieved a complete pain resolution and functional restoration while preserving maximum dentin structure. Minimal preparation and immediate dentin sealing enhanced stability and reduced microleakage risk, with excellent esthetic integration. Conclusion: MDPT represents an effective biomimetic solution for cracked teeth, combining minimal invasiveness with optimal clinical outcomes. The technique demonstrates significant advantages in tooth structure preservation and restoration longevity. Comparative studies are needed to further validate its clinical benefits.

  • Open Access

    Digital Impressions for Customized Post‐and‐Core Restorations in Deep and Narrow Canals: A Case Report Utilizing Scan Posts

    by Ling Lin, Pingping Cai, Zhifeng Zheng, Zhiqiang Zheng, Jie Lin

    Background: Traditional impression techniques for customized post‐and‐core restorations often encounter challenges such as bubble and void formation, requiring a high level of skill from practitioners. Recent advancements in digital technology, particularly intraoral scanners (IOSs), have improved restoration processes, though capturing post spaces with IOS remains problematic due to their deep and narrow nature. Case Presentation: This report details the use of digital impressions for post‐and‐core restorations in both anterior and posterior teeth. By designing a scan post that conforms to the shape of the post space, accurate data capture of the post space is achieved. The integration of IOS with computer‐aided design/computer‐aided manufacturing (CAD/CAM) technology enables the creation of post‐and‐core restorations that precisely fit the root canal morphology. This approach results in a thin and evenly distributed cement layer, thereby reducing the risk of tooth fracture. Conclusion: This technique effectively overcomes the limitations of traditional silicone impressions for customized post‐and‐core restorations. It offers a viable restoration method for single‐rooted teeth and addresses challenges related to acquiring impressions for split cast post‐and‐cores. However, further laboratory research and clinical trials are necessary to thoroughly evaluate the accuracy and reliability of this method.

  • Open Access

    Effect of geometry on clasp retention force: a finite element analysis study

    by Ruizhen Chen, Yao Chen, Zhiqiang Zheng, Jie Lin

    The retention force of a realistic clasp is influenced by multiple, interrelated factors, which complicates the identification of the fundamental relationship between clasp geometry and retention force. While realistic clasps exhibit various shapes, they share basic geometric elements such as length, diameter, and curvature. Simpler geometries are often more conducive to identifying the underlying issues. The aim is to investigate the relationship between clasp geometry and retention force using finite element analysis. A three-dimensional clasp model was created in ANSYS 19.0 (ANSYS, USA). Two types of models were analyzed: rod-shaped clasps with varying lengths (1–15 mm) and diameters (0.6–1.6 mm), and bending clasps with different base widths (6–12 mm) and heights (0.5–5 mm), all made from cobalt-chromium alloys. For the rod models, stress and retention force were assessed by applying displacement loads and analyzing data with nonlinear regression. For the bending models, a similar analysis was conducted for varying base widths and heights. Maximum stress consistently concentrated at the clasp base. In rod models, retention force decreased with the third power of length and increased with the fourth power of diameter. For bent specimens, the retention force was approximately inversely proportional to the cube of the base width and inversely proportional to the first power of the height. Finite element analysis revealed distinct functional relationships between clasp geometry and retention force. Further laboratory validation is required.


  • Open Access

    Use of an intraoral scanner and CAD-CAM for simultaneous restoration with a personalized titanium post-core and a zirconia crown

    by Ling Lin, Yingying Zhuo, Pingping Cai, Xi Chen, Zhiqiang Zheng, Jie Lin

    Customized posts-and-cores have been widely used for improved fitness within a prepared post space. However, in comparison to direct restoration, they necessitate an increased number of appointments for patients. A 24-year-old man presented with a maxillary left canine that had fractured due to trauma 10 months previously. For this case, a digital process was used for simultaneous restoration with a personalized titanium post-and-core and a zirconia crown achieved with an intraoral scanner (IOS) and computer-aided design/computer-aided manufacturing (CAD-CAM). This workflow allowed the restoration to be completed in 2 visits, facilitating more effective and predictable treatment, with reduced time and cost for the patient.


  • Open Access

    Effect of abutment design on fracture resistance of resin-matrix ceramic crowns for dental implant restoration: an in vitro study

    by Jie Lin, Pingping Cai, Yingying Zhuo, Ling Lin, Zhiqiang Zheng

    Background: The purpose of this study is to investigate the performance and fracture resistance of different resin-matrix ceramic materials for use in implant-supported single crowns with respect to the abutment design (crown thickness: 1 mm, 2 and 3 mm). Methods: Forty-eight abutments and crowns were fabricated on implants in the right lower first molar. Two resin-matrix ceramic materials for dental crowns were selected for study: (1) a glass-ceramic in a resin interpenetrating matrix (Vita Enamic, Vita, Germany) and (2) a resin-based composite with nanoparticle ceramic filler (Lava Ultimate, 3 M ESPE, USA). Three types of abutments were designed: 1 mm thick crown + custom titanium abutment, 2 mm thick crown + custom titanium abutment and 3 mm thick crown + prefabricated titanium abutment. The experiment was divided into 6 groups (n = 8) according to the crown materials and abutment designs. After 10,000 thermocycles, fracture resistance was measured using a universal testing machine. The statistical significance of differences between various groups were analysed with ANOVA followed by a post hoc Tukey’s honestly significant difference test. The surfaces of the fractured specimens were examined with scanning electron microscopy (SEM). Results: Two-way ANOVA revealed that the abutment design (F = 28.44, P = 1.52 × 10− 8<0.001) and the crown materials (F = 4.37, P = 0.043 < 0.05) had a significant effect on the fracture resistance of implant crown restoration. The Lava Ultimate-2 mm group showed the highest fracture resistance of 2222.74 ± 320.36 N, and the Vita Enamic-3 mm group showed the lowest fracture resistance of 1204.96 ± 130.50 N. Most of the 1 and 2 mm groups had partial crown fractures that could be repaired directly with resin, while the 3 mm group had longitudinal fracture of the crown, and the crowns were detached from the abutments. Conclusion: Based on the in vitro data of this study, the fracture resistance of the 2 mm thick resin-matrix ceramic crown design was higher than that of the 1 and 3 mm groups. The 2 mm thick resin-matrix ceramic crown and personalized abutment are an option to replace zirconia for implant crown restoration.