ÅÖÅke Öhrlund

Åke Öhrlund

*This is an algorithmically generated author record based on publicly available information.

Åke Öhrlund has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Physicochemical Properties of Two Poly-L-Lactic Acid Injectable Implants: Potential Impact on Their Biological Properties

    by Luiz Avelar, Alessandra Haddad, Sabrina G. Fabi, Michael Somenek, Katie Beleznay, Shino Bay Aguilera, Kathryn Taylor-Barnes, Cheri Mao, Åke Öhrlund, Björn Lundgren, et al.

    This study evaluated the thermal properties, crystallinity, particle size, morphology, and in vivo local inflammation and persistence of two poly-L-lactic acid (PLLA) injectable implants, Sculptra® (PLLA-SCA) and GANA V® (PLLA-GA). PLLA-SCA and PLLA-GA underwent differential scanning calorimetry and X-ray powder diffraction to evaluate their thermal properties and degree of crystallinity. X-ray powder diffraction spectra displayed a sharper, more intense peak for PLLA-GA than PLLA-SCA, with smaller peaks on either side of the main peak of PLLA-GA but not PLLA-SCA. Differential scanning calorimetry thermograms indicated three thermal events for both PLLA-SCA and PLLA-GA. For PLLA-SCA, the first two events occurred between 65 °C and 90 °C, and the third event occurred at 165 °C. For PLLA-GA all three events occurred between 156 °C and 169 °C. Heating samples to 120 °C and cooling to room temperature prior to differential scanning calorimetry resulted in no thermal events being observed between 65–90 °C with either product, while three events were observed with PLLA-GA and one event with PLLA-SCA between 156 °C and 169 °C. The median volume distribution diameter was 46.4 µm for PLLA-SCA and 31.7 µm for PLLA-GA. Scanning electron microscopy showed PLLA-GA particles were irregular in shape, had no sharp edges and had a wrinkled and crimped surface, while PLLA-SCA particles displayed plate-like shapes and had smoother surfaces. In vivo inflammatory reactivity scores indicated a slight reaction for PLLA-SCA at all time points (3.7 ± 1.1, 6.1 ± 1.6, 5.7 ± 1.2 and 6.2 ± 1.2 at 2, 12, 26 and 52 weeks, respectively), while for PLLA-GA, a moderate reaction was observed at 12 and 26 weeks (2.9 ± 1.5, 10.1 ± 1.0, 9.4 ± 0.7 and 7.1 ± 1.3 at 2, 12, 26 and 52 weeks, respectively). PLLA-SCA and PLLA-GA had similar persistence scores at 2, 12 and 26 weeks, while at 52 weeks the score was markedly higher for PLLA-SCA versus PLLA-GA (1.9 ± 0.2 versus 0.7 ± 0.2). In conclusion, PLLA-SCA is more amorphous than PLLA-GA. The single melting point of PLLA-SCA contrasts with the broader spectrum of melting points for PLLA-GA suggests a more homogenous formulation of PLLA-SCA. This, and its less crystalline structure, result in the slower degradation rate and more sustained biological response of PLLA-SCA compared with PLLA-GA. The physiochemical properties of PLLAs affect the biological response in clinical practice and should be taken into consideration when selecting a PLLA treatment for aesthetic use.


  • Open Access

    Physicochemical Properties of Two Poly-L-Lactic Acid Injectable Implants: Potential Impact on Their Biological Properties

    by Luiz Avelar, Alessandra Haddad, Sabrina G Fabi, Michael Somenek, Katie Beleznay, Shino Bay Aguilera, Kathlyn Taylor-Barnes, Peter Morgan, Cheri Mao, Åke Öhrlund, et al.

    The objective of this study was to evaluate thermal properties and crystallinity of two poly-L-lactic acid (PLLA) injectable implants, Sculptra® (PLLA-SCA) and GANA V® (PLLA-GA), and the extent to which these properties might impact their biological response. PLLA-SCA and PLLA-GA (800mg/sample) underwent differential scanning calorimetry and X-ray powder diffraction to evaluate their thermal properties and degree of crystallinity. X-ray powder diffraction spectra displayed a sharper, more intense peak for PLLA-GA than PLLA-SCA, with smaller peaks on either side of the main peak of PLLA-GA but not PLLA-SCA. Differential scanning calorimetry thermograms indicated three thermal events for both PLLA-SCA and PLLA-GA. For PLLA-SCA, the first two events occurred between 65°C and 90°C and the third event occurred at 165°C. For PLLA-GA all three events occurred between 156°C and 169°C. Heating samples to 120°C and cooling to room temperature prior to differential scanning calorimetry resulted in no thermal events being observed between 65–90°C with either product, while three events were observed with PLLA-GA and one event with PLLA-SCA between 156°C and 169°C. In conclusion, PLLA-SCA is more amorphous than PLLA-GA. The single melting point of PLLA-SCA contrasts with the broader spectrum of melting points for PLLA-GA suggests a more homogenous formulation of PLLA-SCA. This, and its less crystalline structure, result in the slower degradation rate and more sustained biological response of PLLA-SCA compared with PLLA-GA. The physiochemical properties of PLLAs affect the biological response in clinical practice and should be taken into consideration when selecting a PLLA treatment for aesthetic use.


  • The Myth of the “Biphasic” Hyaluronic Acid Filler

    by J. Åke Msc Öhrlund, Katarina L. M. Edsman

    BACKGROUND The terms “biphasic” and “monophasic” have been used frequently as a means of differentiating hyaluronic acid (HA) fillers. This type of categorization is based on misinterpretations of the term “phase” and provides no help to the practitioner when selecting the most appropriate product for each indication, patient, and injection technique. OBJECTIVE The purpose of this study was to analyze the properties of 2 HA filler families; Juvederm (JUV) (Allergan), often stated to be monophasic and Restylane (RES) (Galderma), often stated to be biphasic, and discuss what properties may have led to the use of the terms monophasic and biphasic. MATERIALS AND METHODS Three different methods were used for JUV and RES: determination of extractable HA; determination of water uptake; and microscopy. RESULTS The analyzed products were shown to contain both observable gel particles and extractable HA and have the ability to absorb added water. CONCLUSION The categorization of HA fillers as biphasic or monophasic was shown to be scientifically incorrect and should therefore be avoided. Further analytical measurement of the properties leading to this misinterpretation can provide information to discriminate and categorize HA fillers on a sounder scientific basis.