Stepan Jirous
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stepan Jirous has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Richard Rokyta
Department of Cardiology, University Hospital and Faculty of Medicine Pilsen, Charles University, alej Svobody 80, Pilsen, 304 60, Czech Republic
2 shared publicationsDavid Slezak
Department of Cardiology, University Hospital and Faculty of Medicine Pilsen, Charles University, alej Svobody 80, Pilsen, 304 60, Czech Republic
1 shared publicationIvo Bernat
Department of Cardiology, University Hospital and Faculty of Medicine Pilsen, Charles University, alej Svobody 80, Pilsen, 304 60, Czech Republic
1 shared publication- Ivo Bernat
Department of Cardiology, University Hospital and Faculty of Medicine Pilsen, Charles University, Pilsen, Czech Republic
1 shared publication Jan Duršpek
Fakultní nemocnice Plzeň Kardiologické oddělení Komplexní kardiovaskulární centrum
1 shared publicationRoman Miklik
Department of Cardiology, University Hospital and Faculty of Medicine Pilsen, Charles University, alej Svobody 80, Pilsen, 304 60, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 1 July 2020
- Published by Oxford University Press (OUP) in European Heart Journal Supplements
- Vol. 22 (Supplement) , F23-F29
Post-procedural radial artery occlusion and patency detection using duplex ultrasound vs. the reverse Barbeau test
The transradial approach is recommended as a first choice in coronary catheterizations and interventions, for among other reasons, the reduction in the number of local complications. A head-to-head comparison of the reverse Barbeau test (RBT) and duplex ultrasonography (DUSG) for the detection of post-procedural radial artery patency and occlusion has not yet been evaluated. In 500 patients from our same-day discharge program (age 65 ± 9.4 years, 148 women), radial artery patency and occlusion, compression time, haematomas, and other local complications were evaluated. Radial artery patency was confirmed in 495 patients (99.0%), and complete radial artery occlusion (RAO) was detected in 2 (0.4%) patients using both methods. In 3 patients (0.6%), the RBT was negative, while incomplete RAO was detected by DUSG. Superficial haematomas (˃ 5 but ≤10 cm) were found in 27 (5.4%) patients. There were no other local complications. Detection of radial artery patency and occlusion using the RBT and DUSG was comparable. The incidence of RAO in our study was extremely low. Thanks to its simplicity, the RBT has the potential to be used as the first method of detection of radial occlusion after coronary catheterizations.
- 1 July 2020
- Published by Oxford University Press (OUP) in European Heart Journal Supplements
- Vol. 22 (Supplement) , F23-F29
Open AccessPost-procedural radial artery occlusion and patency detection using duplex ultrasound vs. the reverse Barbeau test
The transradial approach is recommended as a first choice in coronary catheterizations and interventions, for among other reasons, the reduction in the number of local complications. A head-to-head comparison of the reverse Barbeau test (RBT) and duplex ultrasonography (DUSG) for the detection of post-procedural radial artery patency and occlusion has not yet been evaluated. In 500 patients from our same-day discharge program (age 65 ± 9.4 years, 148 women), radial artery patency and occlusion, compression time, haematomas, and other local complications were evaluated. Radial artery patency was confirmed in 495 patients (99.0%), and complete radial artery occlusion (RAO) was detected in 2 (0.4%) patients using both methods. In 3 patients (0.6%), the RBT was negative, while incomplete RAO was detected by DUSG. Superficial haematomas (˃ 5 but ≤10 cm) were found in 27 (5.4%) patients. There were no other local complications. Detection of radial artery patency and occlusion using the RBT and DUSG was comparable. The incidence of RAO in our study was extremely low. Thanks to its simplicity, the RBT has the potential to be used as the first method of detection of radial occlusion after coronary catheterizations.
- 1 April 2018
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 60 (2) , e122-e126
Patent hemostasis and comparison of two compression devices after transradial coronary catheterization and intervention
Cíl: Cílem práce bylo porovnat dva kompresní prostředky po transradiální koronární katetrizaci a intervenci. Metody: Z konsekutivně zařazených 280 pacientů, katetrizovaných a intervenovaných (n = 74) v programu jednodenní hospitalizace, jich mělo 140 komprimováno radiální tepnu po výkonu pomocí kompresního prostředku TR Band (TB) a 140 pomocí prostředku Seal-One (SO). Hodnotili jsme dobu potřebnou k dosažení perfuzní hemostázy, celkovou dobu komprese a lokální komplikace. Výsledky: Perfuzní hemostáza v TB skupině byla dosažena za 17,5 ± 10,3 min, ve skupině SO za 21,4 ± 10,5 min (p = NS). Celková doba komprese radiální tepny dosahovala ve skupině TB 90,7 ± 38,4 min a ve skupině SO 64,0 ± 26,5 min (p < 0,001). Výskyt hematomů ≥ 5 cm byl v obou skupinách stejný (6,4 % vs. 6,4 %, p = NS), výskyt hematomů nad 10 cm byl ve skupině TB 0,7 % a ve skupině SO 1,4 % (p = NS). V obou skupinách nebyly prokázány žádný uzávěr radiální tepny ani další lokální komplikace při propuštění. Závěr: Komprese radiální tepny pomocí prostředků TR Band a Seal-One je spojena s časným dosažením perfuzní hemostázy a krátkou celkovou dobou komprese. Průměrná doba komprese prostředkem Seal-One byla v naší studii kratší. Komprese radiální tepny po výkonu nebyla spojena s výskytem uzávěru radiální tepny při propuštění ani dalšími lokálními komplikacemi kromě nízkého výskytu klinicky nezávažných hematomů.
- 1 April 2018
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 60 (2) , e122-e126
Patent hemostasis and comparison of two compression devices after transradial coronary catheterization and intervention
Cíl: Cílem práce bylo porovnat dva kompresní prostředky po transradiální koronární katetrizaci a intervenci. Metody: Z konsekutivně zařazených 280 pacientů, katetrizovaných a intervenovaných (n = 74) v programu jednodenní hospitalizace, jich mělo 140 komprimováno radiální tepnu po výkonu pomocí kompresního prostředku TR Band (TB) a 140 pomocí prostředku Seal-One (SO). Hodnotili jsme dobu potřebnou k dosažení perfuzní hemostázy, celkovou dobu komprese a lokální komplikace. Výsledky: Perfuzní hemostáza v TB skupině byla dosažena za 17,5 ± 10,3 min, ve skupině SO za 21,4 ± 10,5 min (p = NS). Celková doba komprese radiální tepny dosahovala ve skupině TB 90,7 ± 38,4 min a ve skupině SO 64,0 ± 26,5 min (p < 0,001). Výskyt hematomů ≥ 5 cm byl v obou skupinách stejný (6,4 % vs. 6,4 %, p = NS), výskyt hematomů nad 10 cm byl ve skupině TB 0,7 % a ve skupině SO 1,4 % (p = NS). V obou skupinách nebyly prokázány žádný uzávěr radiální tepny ani další lokální komplikace při propuštění. Závěr: Komprese radiální tepny pomocí prostředků TR Band a Seal-One je spojena s časným dosažením perfuzní hemostázy a krátkou celkovou dobou komprese. Průměrná doba komprese prostředkem Seal-One byla v naší studii kratší. Komprese radiální tepny po výkonu nebyla spojena s výskytem uzávěru radiální tepny při propuštění ani dalšími lokálními komplikacemi kromě nízkého výskytu klinicky nezávažných hematomů.