Erick Ball
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Erick Ball has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Ephrahim Garcia
Cornell University
2 shared publicationsJordan B Chipka
Cornell University
1 shared publicationMichael A Meller
Cornell University
1 shared publication
Latest Publications
- 18 October 2016
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 25 (11) , 115024
Modeling and testing of a knitted-sleeve fluidic artificial muscle
The knitted-sleeve fluidic muscle is similar in design to a traditional McKibben muscle, with a separate bladder and sleeve. However, in place of a braided sleeve, it uses a tubular-knit sleeve made from a thin strand of flexible but inextensible yarn. When the bladder is pressurized, the sleeve expands by letting the loops of fiber slide past each other, changing the dimensions of the rectangular cells in the stitch pattern. Ideally, the internal volume of the sleeve would reach a maximum when its length has contracted by 2/3 from its maximum length, and although this is not reachable in practice, preliminary tests show that free contraction greater than 50% is achievable. The motion relies on using a fiber with a low coefficient of friction in order to reduce hysteresis to an acceptable level. In addition to increased stroke length, potential advantages of this technique include slower force drop-off during the stroke, more useable energy in certain applications, and greater similarity to the force–length relationship of skeletal muscle. Its main limitation is its potentially greater effect from friction compared to other fluidic muscle designs.
- 18 October 2016
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 25 (11) , 115024
Modeling and testing of a knitted-sleeve fluidic artificial muscle
The knitted-sleeve fluidic muscle is similar in design to a traditional McKibben muscle, with a separate bladder and sleeve. However, in place of a braided sleeve, it uses a tubular-knit sleeve made from a thin strand of flexible but inextensible yarn. When the bladder is pressurized, the sleeve expands by letting the loops of fiber slide past each other, changing the dimensions of the rectangular cells in the stitch pattern. Ideally, the internal volume of the sleeve would reach a maximum when its length has contracted by 2/3 from its maximum length, and although this is not reachable in practice, preliminary tests show that free contraction greater than 50% is achievable. The motion relies on using a fiber with a low coefficient of friction in order to reduce hysteresis to an acceptable level. In addition to increased stroke length, potential advantages of this technique include slower force drop-off during the stroke, more useable energy in certain applications, and greater similarity to the force–length relationship of skeletal muscle. Its main limitation is its potentially greater effect from friction compared to other fluidic muscle designs.
- 5 August 2016
- Published by ASME International in Journal of Medical Devices
- Vol. 10 (4) , 041001
Effects of Bladder Geometry in Pneumatic Artificial Muscles
Designing optimal pneumatic muscles for a particular application requires an accurate model of the hyperelastic bladder and how it influences contraction force. Previous work does not fully explain the influence of bladder prestrain on actuator characteristics. We present here modeling and experimental data on the actuation properties of artificial muscles constructed with varying bladder prestrain and wall thickness. The tests determine quasi-static force–length relationships during extension and contraction, for muscles constructed with unstretched bladder lengths equal to 55%, 66%, and 97% of the stretched muscle length and two different wall thicknesses. Actuator force and maximum contraction length are found to depend strongly on both the prestrain and the thickness of the rubber, making existing models inadequate for choosing bladder geometry. A model is presented to better predict force–length characteristics from geometric parameters, using a novel thick-walled tube calculation to account for the nonlinear elastic properties of the bladder. It includes axial force generated by stretching the bladder lengthwise, and it also describes the hoop stress created by radial expansion of the muscle that partially counteracts the internal fluid pressure exerted outward on the mesh. This effective reduction in pressure affects both axial muscle force and mesh-on-bladder friction. The rubber bladder is modeled as a Mooney–Rivlin incompressible solid. The axial force generated by the mesh is found directly from contact forces rather than from potential energy. Modeling the bladder as a thin-walled tube gives a close match to experimental data on wall thickness, but a thick-walled bladder model is found to be necessary for explaining the effects of prestrain.
- 5 August 2016
- Published by ASME International in Journal of Medical Devices
- Vol. 10 (4) , 041001
Effects of Bladder Geometry in Pneumatic Artificial Muscles
Designing optimal pneumatic muscles for a particular application requires an accurate model of the hyperelastic bladder and how it influences contraction force. Previous work does not fully explain the influence of bladder prestrain on actuator characteristics. We present here modeling and experimental data on the actuation properties of artificial muscles constructed with varying bladder prestrain and wall thickness. The tests determine quasi-static force–length relationships during extension and contraction, for muscles constructed with unstretched bladder lengths equal to 55%, 66%, and 97% of the stretched muscle length and two different wall thicknesses. Actuator force and maximum contraction length are found to depend strongly on both the prestrain and the thickness of the rubber, making existing models inadequate for choosing bladder geometry. A model is presented to better predict force–length characteristics from geometric parameters, using a novel thick-walled tube calculation to account for the nonlinear elastic properties of the bladder. It includes axial force generated by stretching the bladder lengthwise, and it also describes the hoop stress created by radial expansion of the muscle that partially counteracts the internal fluid pressure exerted outward on the mesh. This effective reduction in pressure affects both axial muscle force and mesh-on-bladder friction. The rubber bladder is modeled as a Mooney–Rivlin incompressible solid. The axial force generated by the mesh is found directly from contact forces rather than from potential energy. Modeling the bladder as a thin-walled tube gives a close match to experimental data on wall thickness, but a thick-walled bladder model is found to be necessary for explaining the effects of prestrain.