HSHirotatsu Sato

Hirotatsu Sato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hirotatsu Sato has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Case of a Right Gastric Artery Aneurysm Caused by the Collateral Flow Changes Due to the Coexistence of Median Arcuate Ligament Syndrome and a Celiac Artery Anomaly

    by Yamato Tsunoda, Hirotatsu Sato, Tetsuo Sonomura, Yuichi Miyake, Naoki Nishioka, Fumihiro Tanaka, Kodai Fukuda, Ryuta Okuhira, Nobuyuki Higashino, Atsufumi Kamisako, et al.

    A man in his 60s presented with severe epigastric pain. Abdominal computed tomography revealed an aneurysm of the right gastric artery, which branched from an aberrant gastroduodenal artery originating from the axis of the splenic artery. Other vascular anomalies included a left gastric artery arising directly from the aorta and several additional arterial variations. Computed tomography also revealed stenosis of the axes of the celiac artery and left gastric artery. The aneurysm was thought to be caused by the stenosis due to median arcuate ligament syndrome. Transcatheter arterial embolization was successfully performed. This case highlights that median arcuate ligament syndrome combined with vascular anomalies can alter hemodynamics and lead to the development of uncommon gastric artery aneurysms.

  • Factors that Enhance the Stability of Polidocanol and Monoethanolamine Oleic Acid Foams, and Identification of the Optimal Foam-Creating Device

    by Nobuyuki Higashino, Tetsuo Sonomura, Ryosuke Mimura, Kodai Fukuda, Hirotatsu Sato, Nobuyuki Kawai

    Purpose To investigate the effects of the air ratio and the addition of glucose solution (Gluc) on the stability of polidocanol-nonionic water-soluble contrast medium (Po/CM) and monoethanolamine oleate-nonionic water-soluble contrast medium (EO/CM) foams, and to identify the optimal device to prepare these foams. Materials and Methods Four sclerosants were used: Po/CM (Po:CM = 1:1), Po/CM-Gluc (Po:CM:70% Gluc = 2:1:1), EO/CM (EO:CM = 1:1), and EO/CM-Gluc (EO:CM:70% Gluc = 2:1:1). The four sclerosants were mixed with air at ratios of 1:4, 1:7, and 1:10 using the Micro Magic connector (MM), hydrophobic emulsifying connector (Hbic), and hydrophilic emulsifying connector (Hlic). The times taken to prepare the foams using each device and the foam half-lives were measured. Results The Po/CM (1:10) and Po/CM-Gluc (1:10) foams could not be prepared using any device. The EO/CM-Gluc (1:10), Po/CM (1:7), and Po/CM-Gluc (1:7) foams could not be prepared using the MM. The times taken to prepare the foams were not significantly different between the Hbic and Hlic for EO/CM-Gluc (1:4) and Po/CM (1:4). The times taken to prepare the other foams decreased significantly in the order MM > Hbic > Hlic. The half-lives of the foams were significantly prolonged by increasing the air ratio. For foams with the same air ratio, the presence of Gluc significantly increased the half-lives of EO/CM and Po/CM compared with the foams without Gluc. Conclusion The half-lives of foams were prolonged by increasing their air ratio and by adding Gluc. Of the tested mixture devices, Hlic created foams with longer half-lives in the shortest time. Graphical abstract


  • Open Access

    Successful coil embolization of a ruptured aneurysm of the arc of Riolan artery

    by Hirotatsu Sato, Tetsuo Sonomura, Hironobu Ihira, Akira Ikoma, Nozomu Shima, Tomoya Fukui, Kodai Fukuda, Shota Ueda, Ryuta Okuhira, Nobuyuki Higashino, et al.


  • Comparison of Soluble Gelatin Sponge Particles and Tris-acryl Gelatin Microspheres for Bariatric Arterial Embolization in Swine

    by Hirotatsu Sato, Tetsuo Sonomura, Masataka Koike, Ibu Matsuzaki, Ryuki Shimono, Hiroki Furotani, Shin-Ichi Murata


  • Comparison of Uterine Necrosis After Uterine Artery Embolization with Soluble Gelatin Sponge Particles or Tris-acryl Gelatin Microspheres in Swine

    by Hirotatsu Sato, Tetsuo Sonomura, Saeko Onishi, Masataka Koike, Ryota Tanaka, Shota Ueda, Ryuta Okuhira, Atsufumi Kamisako, Takao Koyama, Nozomu Shima, et al.

    Purpose To compare the recanalization of the uterine arteries and uterine necrosis after uterine artery embolization (UAE) using either soluble gelatin sponge particles (SGS), which dissolve in saline, or tris-acryl gelatin microspheres (MS), which are permanent embolic materials, in swine. Methods Fourteen uteri in seven swine were divided into two groups for embolization with either 500–1000 µm SGS (SGS group) or 500–700 µm MS (MS group) (seven uteri per group). The uterine arteries were embolized using SGS or MS, and angiography was performed to evaluate recanalization of the uterine arteries immediately, 1, 2, 3, 4, 5, and 6 h, and 3 days after embolization. On day 3, the uteri were removed to determine the macroscopic necrosis rate and for histopathologic examination. Results In the SGS group, four uterine arteries were completely recanalized, two were partially recanalized, and one was still occluded 5 h after embolization. In contrast, all seven uterine arteries in the MS group were still occluded 6 h after embolization. The complete recanalization rate at 3 days was significantly greater in the SGS group than in the MS group (100.0% vs. 14.3%, respectively; P = .0047). The mean uterine necrosis rate was not significantly different between the SGS and MS groups (15.0 ± 15.7% vs. 26.8 ± 13.3%, respectively; P = .096). The mean smallest arterial diameter containing embolic materials was 48.2 ± 22.0 μm (range 21–109 μm) for SGS and 446.7 ± 107.0 μm (range 352–742 μm) for MS (P < .0001). Conclusion The uterine arteries recanalized earlier in the SGS group than in the MS group and the uterine necrosis rates were similar in both groups. SGS have the potential for a more distal penetration in comparison with MS.


  • Balloon-Assisted Embolization of Wide-Neck Aneurysms Using a Mixture of n-Butyl Cyanoacrylate, Lipiodol, and Ethanol in Swine: A Comparison of Four n-Butyl Cyanoacrylate Concentrations

    by Mizuki Hama, Tetsuo Sonomura, Akira Ikoma, Masataka Koike, Atsufumi Kamisako, Ryota Tanaka, Takao Koyama, Hirotatsu Sato, Fumihiro Tanaka, Shota Ueda, et al.

    Purpose To determine the optimal ratio of n-butyl cyanoacrylate (NBCA)–Lipiodol–ethanol (NLE) mixture for balloon-assisted embolization of wide-neck aneurysms. Materials and methods We created 32 wide-neck aneurysms on both the common carotid arteries and external iliac arteries in eight female swine. Eight aneurysms were randomly assigned to four groups. Under balloon occlusion, the aneurysms were packed using NLE at one of four ratios of NLE: 2:2:1 (NLE221; 40%NBCA); 3:6:1 (NLE361; 30%NBCA); 2:7:1 (NLE271; 20%NBCA); and 1:5:1 (NLE151; 14.3%NBCA). We performed angiography before and after embolization to assess the aneurysms, and we compared adhesion between NLE and the balloon and assessed NLE migration. Three days after embolization, the aneurysms were removed for histopathologic evaluation. Results Embolization was performed in 27 aneurysms. Adhesion between NLE and the balloon was not observed in any group. NLE migration was found in 0/7 aneurysms in the NLE221 group, 0/6 in the NLE361 group, 5/6 in the NLE271 group, and 7/8 in the NLE151 group. NLE migration was significantly lower in the NLE221 group than in the NLE271 and NLE151 groups (P = 0.0047 and 0.0014, respectively) and was significantly lower in the NLE361 group than in the NLE271 and NLE151 groups (P = 0.0152 and 0.0047, respectively). Media necrosis of the arterial wall close to the aneurysms was observed in all groups. Conclusion NLE with an NBCA concentration of ≥ 30% is a safe and feasible embolic material for balloon-assisted embolization of wide-neck aneurysms in swine in the short term up to 3 days after embolization.