Fernando Antonio de Melo Sá Cavalcanti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fernando Antonio de Melo Sá Cavalcanti has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Juliana Oliveira Batista
Universidade Federal de Alagoas
4 shared publications - Leonardo Marques Monteiro
Universidade de São Paulo
4 shared publications - Morgana Maria Pitta Duarte Cavalcante
Universidade Federal de Alagoas
3 shared publications - Ricardo Carvalho Cabús
Universidade Federal de Alagoas
3 shared publications - Girleno Alves de Almeida
Universidade Federal de Alagoas
2 shared publications - Mara Rúbia Oliveira Araújo
Universidade Federal de Alagoas/Professora
2 shared publications
Latest Publications
- Open Access
- 6 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Avaliação da qualidade do ar em praça de alimentação de shopping center: um estudo de caso em Maceió-AL
Este estudo tem como objetivo avaliar as condições da Qualidade do Ar Interior em uma praça de alimentação de shopping center localizado na cidade de Maceió-AL e contribuir para a produção de espaços adequados ao uso saudável dos ocupantes. A pesquisa caracteriza-se como quantitativa, exploratória e descritiva, baseada em visitas in loco, observação participante, registros fotográficos e medições ambientais com equipamentos específicos, considerando variáveis como temperatura, umidade relativa e concentração de CO₂, coletadas em diferentes pontos e horários e comparadas a parâmetros normativos. Os resultados indicaram que, embora o ambiente seja climatizado artificialmente, nem todas as condições térmicas permaneceram dentro das zonas de conforto, sobretudo devido a temperaturas elevadas em determinados pontos, enquanto a concentração de CO₂ apresentou valores dentro dos limites aceitáveis, com ocorrências pontuais acima do recomendado. Como contribuição, o estudo amplia a compreensão das condições ambientais nesses espaços e reforça a importância do monitoramento e ajuste dos sistemas de climatização para garantir melhores condições de conforto e qualidade do ar para os usuários.
- 6 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Open AccessAvaliação da qualidade do ar em praça de alimentação de shopping center: um estudo de caso em Maceió-AL
Este estudo tem como objetivo avaliar as condições da Qualidade do Ar Interior em uma praça de alimentação de shopping center localizado na cidade de Maceió-AL e contribuir para a produção de espaços adequados ao uso saudável dos ocupantes. A pesquisa caracteriza-se como quantitativa, exploratória e descritiva, baseada em visitas in loco, observação participante, registros fotográficos e medições ambientais com equipamentos específicos, considerando variáveis como temperatura, umidade relativa e concentração de CO₂, coletadas em diferentes pontos e horários e comparadas a parâmetros normativos. Os resultados indicaram que, embora o ambiente seja climatizado artificialmente, nem todas as condições térmicas permaneceram dentro das zonas de conforto, sobretudo devido a temperaturas elevadas em determinados pontos, enquanto a concentração de CO₂ apresentou valores dentro dos limites aceitáveis, com ocorrências pontuais acima do recomendado. Como contribuição, o estudo amplia a compreensão das condições ambientais nesses espaços e reforça a importância do monitoramento e ajuste dos sistemas de climatização para garantir melhores condições de conforto e qualidade do ar para os usuários.
- Open Access
- 6 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Ambiência de praça de alimentação em shopping center com foco no conforto acústico e luminoso
This study aims to analyze the acoustic performance and lighting conditions in a food court of a shopping center located in Maceió-AL, and to contribute to the design of efficient and adequate leisure environments. The research has a quantitative, exploratory, and descriptive approach, with data collection carried out through in-situ measurements of sound pressure levels (dB) and illuminance (lux) at different points, days, and times in the food court. The results indicated that all noise levels exceeded the recommended limits, characterizing the environment as acoustically inadequate. Regarding lighting, there was great variability in illuminance levels, with values below and above the recommended levels, evidencing a lack of uniformity, the presence of glare in areas with natural light, and points with insufficient lighting. It is concluded that, despite the design strategies adopted, the environment does not fully meet the evaluated requirements and reinforces the need for interventions to improve the environmental quality of this space.
- 6 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Open AccessAmbiência de praça de alimentação em shopping center com foco no conforto acústico e luminoso
This study aims to analyze the acoustic performance and lighting conditions in a food court of a shopping center located in Maceió-AL, and to contribute to the design of efficient and adequate leisure environments. The research has a quantitative, exploratory, and descriptive approach, with data collection carried out through in-situ measurements of sound pressure levels (dB) and illuminance (lux) at different points, days, and times in the food court. The results indicated that all noise levels exceeded the recommended limits, characterizing the environment as acoustically inadequate. Regarding lighting, there was great variability in illuminance levels, with values below and above the recommended levels, evidencing a lack of uniformity, the presence of glare in areas with natural light, and points with insufficient lighting. It is concluded that, despite the design strategies adopted, the environment does not fully meet the evaluated requirements and reinforces the need for interventions to improve the environmental quality of this space.
- Open Access
- 6 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Avaliação da qualidade do ar em salas de aula de ensino superior em Maceió-AL
This study presents a comparative assessment of environmental conditions in two classrooms, emphasizing the importance of healthy school architecture as a key factor in the teaching–learning process. The research considers environmental variables that directly affect users’ health, well-being, and performance. The methodology was structured in four stages: (i) selection of the study environments, (ii) systematic collection of environmental parameters, (iii) organization and statistical processing of the data, and (iv) comparative analysis based on national and international standards. The results show that both classrooms exhibited non-compliance with normative limits, although for different reasons, highlighting the complexity of environmental control in school buildings located in hot and humid climates.
- 6 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Open AccessAvaliação da qualidade do ar em salas de aula de ensino superior em Maceió-AL
This study presents a comparative assessment of environmental conditions in two classrooms, emphasizing the importance of healthy school architecture as a key factor in the teaching–learning process. The research considers environmental variables that directly affect users’ health, well-being, and performance. The methodology was structured in four stages: (i) selection of the study environments, (ii) systematic collection of environmental parameters, (iii) organization and statistical processing of the data, and (iv) comparative analysis based on national and international standards. The results show that both classrooms exhibited non-compliance with normative limits, although for different reasons, highlighting the complexity of environmental control in school buildings located in hot and humid climates.
- Open Access
- 5 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Acessar, circular, permanecer
This study aims to critically analyze the access points and circulation flows within the Architecture Block of the IFS – Lagarto Campus/SE, based on the renovation project. The research adopts a qualitative case study methodology, with three stages: survey, document analysis, and graphical analysis of the morphologies, in comparison with the requirements of NBR 9050:2020. The results indicate that the linear-extensive layout of the campus creates physical obstacles, especially due to the terminal location of the block. Additionally, it is observed that access to the spaces occurs only via stairs that do not comply with the standards and lack nearby sanitary facilities, impairing autonomy. The contribution demonstrates that accessibility requires a systemic spatial reorganization, going beyond mere legal compliance.
- 5 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Open AccessAcessar, circular, permanecer
This study aims to critically analyze the access points and circulation flows within the Architecture Block of the IFS – Lagarto Campus/SE, based on the renovation project. The research adopts a qualitative case study methodology, with three stages: survey, document analysis, and graphical analysis of the morphologies, in comparison with the requirements of NBR 9050:2020. The results indicate that the linear-extensive layout of the campus creates physical obstacles, especially due to the terminal location of the block. Additionally, it is observed that access to the spaces occurs only via stairs that do not comply with the standards and lack nearby sanitary facilities, impairing autonomy. The contribution demonstrates that accessibility requires a systemic spatial reorganization, going beyond mere legal compliance.
- Open Access
- 3 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Recomendações para implantação de UBS em Palmeira dos Índios-AL
This study aims to analyze the influence of building siting and envelope characteristics on the thermal performance and energy efficiency of Type I Primary Health Care Units (UBS) in the municipality of Palmeira dos Índios, Alagoas, Brazil. An exploratory and descriptive methodology was adopted, comprising on-site surveys of five units, solar orientation analysis through superposition with the local sun path diagram, and characterization of construction systems in accordance with current technical standards, with evaluation based on the simplified INI-C methodology. The results demonstrate that the adoption of standardized designs, without considering solar orientation and climatic context, compromises thermoenergetic performance, particularly in glazed façades exposed to direct solar radiation. As a contribution, the study proposes siting guidelines better suited to the local climate, highlighting the importance of integrating architectural design with passive strategies to enhance thermal comfort and reduce energy consumption in public healthcare buildings.
- 3 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Open AccessRecomendações para implantação de UBS em Palmeira dos Índios-AL
This study aims to analyze the influence of building siting and envelope characteristics on the thermal performance and energy efficiency of Type I Primary Health Care Units (UBS) in the municipality of Palmeira dos Índios, Alagoas, Brazil. An exploratory and descriptive methodology was adopted, comprising on-site surveys of five units, solar orientation analysis through superposition with the local sun path diagram, and characterization of construction systems in accordance with current technical standards, with evaluation based on the simplified INI-C methodology. The results demonstrate that the adoption of standardized designs, without considering solar orientation and climatic context, compromises thermoenergetic performance, particularly in glazed façades exposed to direct solar radiation. As a contribution, the study proposes siting guidelines better suited to the local climate, highlighting the importance of integrating architectural design with passive strategies to enhance thermal comfort and reduce energy consumption in public healthcare buildings.
- Open Access
- 3 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Influência da forma e revestimentos de poços de luz em habitações térreas
This paper aims to analyze the lighting performance of internal courtyards in single-story buildings located in low latitudes, using the municipality of Canindé do São Francisco - SE as an example, based on the variation in the shape and reflectance of light wells in single-story buildings, as this is a device frequently used in buildings in the Brazilian Northeast. The evaluation of the device's lighting performance was carried out by varying the geometry and reflectances of the model surfaces, this step being guaranteed through computational simulation using TropLux 8.0.71 software. It was identified that for autonomy to occur through this device, it is necessary to work with good geometry and reflectance conditions; otherwise, the device becomes flawed for good lighting performance. Thus, despite being widely used in the city of Canindé, this device cannot provide good natural light conditions for the internal environment independently.
- 3 September 2026
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO
- Vol. 21
Open AccessInfluência da forma e revestimentos de poços de luz em habitações térreas
This paper aims to analyze the lighting performance of internal courtyards in single-story buildings located in low latitudes, using the municipality of Canindé do São Francisco - SE as an example, based on the variation in the shape and reflectance of light wells in single-story buildings, as this is a device frequently used in buildings in the Brazilian Northeast. The evaluation of the device's lighting performance was carried out by varying the geometry and reflectances of the model surfaces, this step being guaranteed through computational simulation using TropLux 8.0.71 software. It was identified that for autonomy to occur through this device, it is necessary to work with good geometry and reflectance conditions; otherwise, the device becomes flawed for good lighting performance. Thus, despite being widely used in the city of Canindé, this device cannot provide good natural light conditions for the internal environment independently.
- Open Access
- 16 August 2025
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO
- Vol. 18
A Configuração urbana e conforto térmico externo
A adequação climática dos ambientes externos urbanos é essencial para o conforto térmico humano, especialmente em cidades tropicais, onde muitas atividades ocorrem ao ar livre. Este estudo tem como objetivo analisar a influência da configuração de espaços urbanos no conforto térmico de usuários sob condições climáticas da cidade de Maceió – AL. Foram selecionados pontos de medição com características espaciais distintas em dois bairros, onde se realizaram medições móveis de temperatura do ar, umidade relativa, velocidade do vento e temperatura de globo. Os resultados indicam que variáveis como presença de vegetação, uso de marquises para sombreamento e materiais das edificações influenciam nas condições microclimáticas e na percepção térmica dos usuários. Nos casos analisados, o sombreamento natural e artificial mostrou-se determinante para maior sensação de conforto. Conclui-se que intervenções urbanas adequadas ao clima tropical são fundamentais para melhor representar a realidade térmica dos usuários em espaços urbanos de regiões tropicais.
- 16 August 2025
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO
- Vol. 18
Open AccessA Configuração urbana e conforto térmico externo
A adequação climática dos ambientes externos urbanos é essencial para o conforto térmico humano, especialmente em cidades tropicais, onde muitas atividades ocorrem ao ar livre. Este estudo tem como objetivo analisar a influência da configuração de espaços urbanos no conforto térmico de usuários sob condições climáticas da cidade de Maceió – AL. Foram selecionados pontos de medição com características espaciais distintas em dois bairros, onde se realizaram medições móveis de temperatura do ar, umidade relativa, velocidade do vento e temperatura de globo. Os resultados indicam que variáveis como presença de vegetação, uso de marquises para sombreamento e materiais das edificações influenciam nas condições microclimáticas e na percepção térmica dos usuários. Nos casos analisados, o sombreamento natural e artificial mostrou-se determinante para maior sensação de conforto. Conclui-se que intervenções urbanas adequadas ao clima tropical são fundamentais para melhor representar a realidade térmica dos usuários em espaços urbanos de regiões tropicais.
- Open Access
- 16 August 2025
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO
- Vol. 18
Experiência dos usuários na praça de alimentação do Shopping Pátio Maceió: uma análise do ambiente a partir da MEAC
Este artigo tem como objetivo desenvolver uma análise do ambiente, a fim de identificar e compreender os aspectos ergonômicos e de acessibilidade. Estes que interferem diretamente na qualidade espacial e consequentemente na experiência do usuário presente na praça de alimentação do Shopping Pátio Maceió. A partir da Metodologia Ergonômica para o Ambiente Construído (MEAC) será possível analisar a praça e suas características centradas no usuário e a sua interação com o ambiente. Através de levantamento de dados e análises, foi possível identificar inadequações, além de elementos projetuais que atuam para uma melhor experiência. Esta pesquisa enriquece o acervo de estudos sobre a qualidade espacial de praças em shopping center que tem o usuário como foco, além de oferecer aporte para gestores e profissionais responsáveis pela projetação desses espaços.
- 16 August 2025
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO
- Vol. 18
Open AccessExperiência dos usuários na praça de alimentação do Shopping Pátio Maceió: uma análise do ambiente a partir da MEAC
Este artigo tem como objetivo desenvolver uma análise do ambiente, a fim de identificar e compreender os aspectos ergonômicos e de acessibilidade. Estes que interferem diretamente na qualidade espacial e consequentemente na experiência do usuário presente na praça de alimentação do Shopping Pátio Maceió. A partir da Metodologia Ergonômica para o Ambiente Construído (MEAC) será possível analisar a praça e suas características centradas no usuário e a sua interação com o ambiente. Através de levantamento de dados e análises, foi possível identificar inadequações, além de elementos projetuais que atuam para uma melhor experiência. Esta pesquisa enriquece o acervo de estudos sobre a qualidade espacial de praças em shopping center que tem o usuário como foco, além de oferecer aporte para gestores e profissionais responsáveis pela projetação desses espaços.
- Open Access
- 16 August 2025
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO
- Vol. 18
ANÁLISE DA ADEQUAÇÃO BIOCLÍMATICA DE UM PROJETO PADRÃO:
Este artigo avalia o desempenho térmico de duas Unidades Básicas de Saúde (UBS) em Palmeira dos Índios, AL, considerando diferentes orientações das fachadas. Foram analisadas a UBS Edval Gaia (80° NE) e a UBS Santo Antônio (300°NO). A pesquisa in loco, realizada entre 11 e 18 de dezembro de 2024, coletou dados de temperatura e umidade relativa do ar na recepção das UBS. Os resultados mostraram que a UBS Edval Gaia apresentou temperaturas mais moderadas e uma variação de umidade relativa mais equilibrada, enquanto a UBS Santo Antônio registrou picos térmicos mais altos, chegando a uma diferença de 11,5°C em relação a temperatura externa obtida em estação meteorológica no mesmo horário. A pesquisa sugere que o uso excessivo de vidro sem proteção solar e a escolha inadequada da orientação das fachadas, impacta negativamente o desempenho térmico e pode influenciar negativamente a eficiência energética das UBS.
- 16 August 2025
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO
- Vol. 18
Open AccessANÁLISE DA ADEQUAÇÃO BIOCLÍMATICA DE UM PROJETO PADRÃO:
Este artigo avalia o desempenho térmico de duas Unidades Básicas de Saúde (UBS) em Palmeira dos Índios, AL, considerando diferentes orientações das fachadas. Foram analisadas a UBS Edval Gaia (80° NE) e a UBS Santo Antônio (300°NO). A pesquisa in loco, realizada entre 11 e 18 de dezembro de 2024, coletou dados de temperatura e umidade relativa do ar na recepção das UBS. Os resultados mostraram que a UBS Edval Gaia apresentou temperaturas mais moderadas e uma variação de umidade relativa mais equilibrada, enquanto a UBS Santo Antônio registrou picos térmicos mais altos, chegando a uma diferença de 11,5°C em relação a temperatura externa obtida em estação meteorológica no mesmo horário. A pesquisa sugere que o uso excessivo de vidro sem proteção solar e a escolha inadequada da orientação das fachadas, impacta negativamente o desempenho térmico e pode influenciar negativamente a eficiência energética das UBS.
- Open Access
- 7 October 2024
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in Encontro Nacional de Tecnologia Do Ambiente ConstruÍdo
- Vol. 20 (1) , 1-13
Conforto Térmico em escolas públicas
Estudos recentes apontam uma ligação intrínseca entre o conforto térmico oferecido pelo ambiente e os níveis de concentração, desempenho e aprendizagem alcançados por seus usuários. Nas instituições públicas de ensino, edificações onde as restrições orçamentárias comumente tornam proibitivo o uso da climatização artificial, a obtenção do conforto térmico depende primordialmente de estratégias passivas de climatização, a exemplo da ventilação natural. O objetivo deste trabalho é avaliar o impacto da velocidade do ar no conforto térmico de uma sala de aula da escola Quintella Cavalcanti, localizada em Arapiraca-AL, município do agreste alagoano, com base em dados de medições in loco de temperatura, utilizando-se a ferramenta CBE Thermal Comfort Tool para estimativas de conforto adaptativo conforme a ASHRAE Standard 55. Foram realizadas 20 medições in loco na estação quente, calculando-se os índices PMV/PPD. Sob velocidade do ar nula, verificou-se sensação de desconforto. Já as estimativas do efeito do movimento do ar indicaram que, mesmo com velocidades < 0,5 m/s, obter-se-ia conforto térmico entre as 8h e 16h (PMV < 0,5), com um efeito de resfriamento fisiológico de até 2,3°C. Ressalta-se a importância do uso dos princípios de adequação bioclimática em edificações para proporcionar conforto térmico aos ocupantes.
- 7 October 2024
- Published by Associacao Nacional de Tecnologia do Ambiente Construido (ANTAC) in Encontro Nacional de Tecnologia Do Ambiente ConstruÍdo
- Vol. 20 (1) , 1-13
Open AccessConforto Térmico em escolas públicas
Estudos recentes apontam uma ligação intrínseca entre o conforto térmico oferecido pelo ambiente e os níveis de concentração, desempenho e aprendizagem alcançados por seus usuários. Nas instituições públicas de ensino, edificações onde as restrições orçamentárias comumente tornam proibitivo o uso da climatização artificial, a obtenção do conforto térmico depende primordialmente de estratégias passivas de climatização, a exemplo da ventilação natural. O objetivo deste trabalho é avaliar o impacto da velocidade do ar no conforto térmico de uma sala de aula da escola Quintella Cavalcanti, localizada em Arapiraca-AL, município do agreste alagoano, com base em dados de medições in loco de temperatura, utilizando-se a ferramenta CBE Thermal Comfort Tool para estimativas de conforto adaptativo conforme a ASHRAE Standard 55. Foram realizadas 20 medições in loco na estação quente, calculando-se os índices PMV/PPD. Sob velocidade do ar nula, verificou-se sensação de desconforto. Já as estimativas do efeito do movimento do ar indicaram que, mesmo com velocidades < 0,5 m/s, obter-se-ia conforto térmico entre as 8h e 16h (PMV < 0,5), com um efeito de resfriamento fisiológico de até 2,3°C. Ressalta-se a importância do uso dos princípios de adequação bioclimática em edificações para proporcionar conforto térmico aos ocupantes.