Arabinda Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arabinda Das has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alok Mukherjee
Electrical Engineering, Government College of Engineering and Ceramic Technology, Kolkata, India
8 shared publications - Palash Kumar Kundu
Department of Electrical Engineering, Jadavpur University, Kolkata, India
8 shared publications Alok Mukherjee
Government College of Engineering and Ceramic Technology
7 shared publicationsPalash Kumar Kundu
Jadavpur University
6 shared publications- Amarnath Sanyal
Calcutta Institute of Engineering and Management, Kolkata, India
3 shared publications - Arunava Kabiraj Thakur
Department of Electrical Engineering, Techno Main Salt Lake, Kolkata, India
3 shared publications
Latest Publications
- 20 November 2023
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 105 (1) , 93-108
Assessment of Different Signal Processing Techniques for Classifying Induction Motor Faults Using PCA Features: A Comparative Analysis
- 20 November 2023
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 105 (1) , 93-108
Assessment of Different Signal Processing Techniques for Classifying Induction Motor Faults Using PCA Features: A Comparative Analysis
- 15 March 2023
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 104 (3) , 623-640
Classification and Authentication of Induction Motor Faults using Time and Frequency Feature Dependent Probabilistic Neural Network Model
- 15 March 2023
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 104 (3) , 623-640
Classification and Authentication of Induction Motor Faults using Time and Frequency Feature Dependent Probabilistic Neural Network Model
- Open Access
- 14 July 2022
- Published by Springer Nature in Research Square
An approach for selecting appropriate mother wavelet and optimal level of decomposition for analyzing induction motor faults using quality parameters under variation in motor loading
Wavelet transform is a widely used mathematical tool for analyzing fault signals. But the major problem lying with wavelet analysis is in the selection of the appropriate mother wavelet. Besides, selection of the optimal level of decomposition is also important since the complexity and time of computation increases proportionately as the level of decomposition increases. In this work, we have proposed a method for selecting an optimal mother wavelet and optimal level of decomposition of three phase fault current signals of induction motor, in order to achieve appreciably accurate result with optimized complexity. Here, we have analyzed the results using mother wavelets from the Daubechies (db), Coiflets (Coif) and Symlets (Sym) gropus and decomposed the fault current signals of three phase induction motors upto five levels. We have also varied the loading on the motor in three discrete steps in order to incorporate robustness to the model and analyzed the four major quality factors, viz., signal to noise ratio (SNR), root Mean square error (RMSE), peak signal to noise ratio (PSNR) and correlation coefficient (CC) for reaching a conclusion regarding optimum mother wavelet selection in favour of Symlet5 mother wavelet decomposed at level 4.
- 14 July 2022
- Published by Springer Nature in Research Square
Open AccessAn approach for selecting appropriate mother wavelet and optimal level of decomposition for analyzing induction motor faults using quality parameters under variation in motor loading
Wavelet transform is a widely used mathematical tool for analyzing fault signals. But the major problem lying with wavelet analysis is in the selection of the appropriate mother wavelet. Besides, selection of the optimal level of decomposition is also important since the complexity and time of computation increases proportionately as the level of decomposition increases. In this work, we have proposed a method for selecting an optimal mother wavelet and optimal level of decomposition of three phase fault current signals of induction motor, in order to achieve appreciably accurate result with optimized complexity. Here, we have analyzed the results using mother wavelets from the Daubechies (db), Coiflets (Coif) and Symlets (Sym) gropus and decomposed the fault current signals of three phase induction motors upto five levels. We have also varied the loading on the motor in three discrete steps in order to incorporate robustness to the model and analyzed the four major quality factors, viz., signal to noise ratio (SNR), root Mean square error (RMSE), peak signal to noise ratio (PSNR) and correlation coefficient (CC) for reaching a conclusion regarding optimum mother wavelet selection in favour of Symlet5 mother wavelet decomposed at level 4.
- 1 April 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (2) , 1057-1075
Application of Poincare analogous time-split signal-based statistical correlation for transmission line fault classification
- 1 April 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (2) , 1057-1075
Application of Poincare analogous time-split signal-based statistical correlation for transmission line fault classification
- 7 February 2022
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 50 (3) , 166-179
Transmission Line Fault Localization With Mesh and Surface Analysis Using PCA Features
The proposed work investigates the application of principal component analysis (PCA) in localizing fault in a 150 km transmission line. Quarter-cycle pre-fault and half-cycle post-fault sending end noisy line currents are analyzed for faults conducted at intermediate locations with varying fault resistance. Principal component scores, so found, are further analyzed to form a planar mesh structure and smooth fit surface model, from which the distance of the test signal is predicted. Finally, the two models have been validated. The two dimension mesh and the three dimension polynomial surface model produce an average percentage error of 0.2923% and 0.2619%, respectively. The maximum Percentage Error obtained using the two methods are 2.167% and 2.033%, respectively. The high accuracy and low computational burden are achieved in presence of power system noise as well as variation of fault location and fault resistance, which indicates the robustness of the proposed localizer models. Besides, the development of the proposed algorithm using PCA only reduces the memory requirement by reducing dimensionality of a data set, enabling faster computation, especially compared to more extensively used supervised intricate analysis like neural networks, support vector machine or complex mathematical approaches like wavelet transform, fuzzy inference schemes.
- 7 February 2022
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 50 (3) , 166-179
Transmission Line Fault Localization With Mesh and Surface Analysis Using PCA Features
The proposed work investigates the application of principal component analysis (PCA) in localizing fault in a 150 km transmission line. Quarter-cycle pre-fault and half-cycle post-fault sending end noisy line currents are analyzed for faults conducted at intermediate locations with varying fault resistance. Principal component scores, so found, are further analyzed to form a planar mesh structure and smooth fit surface model, from which the distance of the test signal is predicted. Finally, the two models have been validated. The two dimension mesh and the three dimension polynomial surface model produce an average percentage error of 0.2923% and 0.2619%, respectively. The maximum Percentage Error obtained using the two methods are 2.167% and 2.033%, respectively. The high accuracy and low computational burden are achieved in presence of power system noise as well as variation of fault location and fault resistance, which indicates the robustness of the proposed localizer models. Besides, the development of the proposed algorithm using PCA only reduces the memory requirement by reducing dimensionality of a data set, enabling faster computation, especially compared to more extensively used supervised intricate analysis like neural networks, support vector machine or complex mathematical approaches like wavelet transform, fuzzy inference schemes.
- 15 June 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 103 (1) , 197-211
Transmission Line Fault Classification under High Noise in Signal: A Direct PCA-Threshold-Based Approach
- 15 June 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 103 (1) , 197-211
Transmission Line Fault Classification under High Noise in Signal: A Direct PCA-Threshold-Based Approach
- 13 April 2021
- Published by Springer Nature in Electrical Engineering
- Vol. 103 (6) , 2929-2944
Classification and localization of transmission line faults using curve fitting technique with Principal component analysis features
- 13 April 2021
- Published by Springer Nature in Electrical Engineering
- Vol. 103 (6) , 2929-2944
Classification and localization of transmission line faults using curve fitting technique with Principal component analysis features
- 29 March 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 102 (5) , 1019-1032
Probabilistic Neural Network-Aided Fast Classification of Transmission Line Faults Using Differencing of Current Signal
- 29 March 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 102 (5) , 1019-1032
Probabilistic Neural Network-Aided Fast Classification of Transmission Line Faults Using Differencing of Current Signal
- 3 February 2021
- Published by Springer Nature in Electrical Engineering
- Vol. 103 (4) , 2113-2126
A supervised principal component analysis-based approach of fault localization in transmission lines for single line to ground faults
- 3 February 2021
- Published by Springer Nature in Electrical Engineering
- Vol. 103 (4) , 2113-2126
A supervised principal component analysis-based approach of fault localization in transmission lines for single line to ground faults