Wilson Tadeu Lopes da Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wilson Tadeu Lopes da Silva has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- André Gomes Da Rocha
NEEA/CRHEA/SHS, São Carlos Engineering School, University of São Paulo, São Carlos, Brazil
1 shared publication - Bruno Ricardo Silva Costa
Universidade Estadual Paulista/UNESP, Brazil
1 shared publication - Evaldo Luiz Gaeta Espíndola
Laboratory of Ecotoxicology and Applied Ecology, Department of Hydraulic and Sanitation, São Carlos School of Engineering, University of São Paulo, São Carlos, Brazil
1 shared publication - Henrique Oldoni
Universidade Estadual de Campinas – UNICAMP, Interdisciplinary Center of Energy Planning - NIPE, Campinas, São Paulo, Brazil
1 shared publication - Isabel Kimiko Sakamoto
Department of Hydraulic and Sanitation, University of São Paulo, São Carlos, Brazil
1 shared publication - Isabelle Cardoso Alves de Lima
Universidade Estadual Paulista “Júlio de Mesquita Filho”, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 30
Hospital effluents into urban sewage and their influence on the development of antibiotic-resistant bacteria
With the advances in the production of new medicines, an increase in their distribution and use in healthcare facilities is inevitable. Medicine and metabolite residues are excreted and sent to the sewage. Thus, hospital effluents are of concern as they concentrate these contaminants in wastewater. It is important to emphasize that, in general, urban sewage treatment plants are not designed for high removal efficiencies of micropollutants. This study aimed to assess the adequacy of conventional methods as indicators of operational efficiency in three treatment plants to determine if they are enough to decrease bacterial-resistant phenotypes (RP) during the treatment process. We conducted four samplings at three sewage treatment plants, including those receiving effluents from a Hospital do Amor in Barretos (Brazil). Two main indicators were used: (1) traditional methodology involving physicochemical parameters and elemental analysis of solids, and (2) identification of microorganisms and antimicrobial susceptibility. Results show that when considering the conventional approach based on physicochemical evaluation, little hospital influence was observed on these indicators. However, when examining antimicrobial susceptibility, we remarked that hospital sewage affected the spread of RP in samples collected in the wastewater treatment plants (WWTP) III and IV. During autumn, winter, spring, and summer, WWTP III presented mean RP proportions around 57%, 42%, 50%, and 60%, and WWTP IV 60, 54, 34, and 41%, respectively. The WWTP II, which has received only urban sewage, showed lower mean values (46, 36, 66, and 50%, respectively). Although a direct relationship between the type of treatment and antimicrobial susceptibility was not identified, it was observed that neither treatment (stabilization pond or activated sludge) effectively reduces microbial resistance. The results raise concerns from a public health perspective and underscore the need for incorporating new protocols for analyzing sanitary effluents and the WWTP’s increased efficiency regarding the medicines.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 30
Open AccessHospital effluents into urban sewage and their influence on the development of antibiotic-resistant bacteria
With the advances in the production of new medicines, an increase in their distribution and use in healthcare facilities is inevitable. Medicine and metabolite residues are excreted and sent to the sewage. Thus, hospital effluents are of concern as they concentrate these contaminants in wastewater. It is important to emphasize that, in general, urban sewage treatment plants are not designed for high removal efficiencies of micropollutants. This study aimed to assess the adequacy of conventional methods as indicators of operational efficiency in three treatment plants to determine if they are enough to decrease bacterial-resistant phenotypes (RP) during the treatment process. We conducted four samplings at three sewage treatment plants, including those receiving effluents from a Hospital do Amor in Barretos (Brazil). Two main indicators were used: (1) traditional methodology involving physicochemical parameters and elemental analysis of solids, and (2) identification of microorganisms and antimicrobial susceptibility. Results show that when considering the conventional approach based on physicochemical evaluation, little hospital influence was observed on these indicators. However, when examining antimicrobial susceptibility, we remarked that hospital sewage affected the spread of RP in samples collected in the wastewater treatment plants (WWTP) III and IV. During autumn, winter, spring, and summer, WWTP III presented mean RP proportions around 57%, 42%, 50%, and 60%, and WWTP IV 60, 54, 34, and 41%, respectively. The WWTP II, which has received only urban sewage, showed lower mean values (46, 36, 66, and 50%, respectively). Although a direct relationship between the type of treatment and antimicrobial susceptibility was not identified, it was observed that neither treatment (stabilization pond or activated sludge) effectively reduces microbial resistance. The results raise concerns from a public health perspective and underscore the need for incorporating new protocols for analyzing sanitary effluents and the WWTP’s increased efficiency regarding the medicines.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Ciência E Agrotecnologia
- Vol. 46
Corn crop responds positively to fertigation with black water from sewage treated by decentralized anaerobic system
The basic sanitation systems are not enough to meet the sanitary requirements in the rural areas of Brazil. Hence, a decentralized anaerobic system was developed by Embrapa to enable the treatment of domestic sewage. The treated sewage effluent (TSE) should be applied to completely replace the N from mineral fertilizer required by corn plants, a typical crop cultivated by Brazilian smallholder farmings for animal feed. Hence, the purpose of this study was to investigate the corn crop responses to the use of TSE as fertilizer. A field experiment was carried out in a sandy clay loam soil at São Carlos, state of São Paulo, Brazil, over 2018-2019 summer growing season of a hybrid corn cultivar with dual aptitude (grain and silage production). Four treatments about application of different nutrient sources were evaluated in a randomized block design with three replications: 1- NPK: urea, simple superphosphate and potassium chloride as nutrient sources; 2- EfPK: TSE as N source + PK from mineral fertilizers; 3- Ef: TSE only; 4- PK: mineral fertilizers only. TSE was applied to crop by short and closed-end furrow irrigation. TSE can be used as a source of nitrogen mainly and other nutrients for corn crop nutrition based on the knowledge of effluent nutrient concentrations. TSE split application through fertirrigation can lead to corn yield parameters close to those from NPK application using only mineral fertilizers as nutrient sources. The reuse of this wastewater is feasible for small-scale corn production which is typical of Brazilian smallholder farming.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Ciência E Agrotecnologia
- Vol. 46
Open AccessCorn crop responds positively to fertigation with black water from sewage treated by decentralized anaerobic system
The basic sanitation systems are not enough to meet the sanitary requirements in the rural areas of Brazil. Hence, a decentralized anaerobic system was developed by Embrapa to enable the treatment of domestic sewage. The treated sewage effluent (TSE) should be applied to completely replace the N from mineral fertilizer required by corn plants, a typical crop cultivated by Brazilian smallholder farmings for animal feed. Hence, the purpose of this study was to investigate the corn crop responses to the use of TSE as fertilizer. A field experiment was carried out in a sandy clay loam soil at São Carlos, state of São Paulo, Brazil, over 2018-2019 summer growing season of a hybrid corn cultivar with dual aptitude (grain and silage production). Four treatments about application of different nutrient sources were evaluated in a randomized block design with three replications: 1- NPK: urea, simple superphosphate and potassium chloride as nutrient sources; 2- EfPK: TSE as N source + PK from mineral fertilizers; 3- Ef: TSE only; 4- PK: mineral fertilizers only. TSE was applied to crop by short and closed-end furrow irrigation. TSE can be used as a source of nitrogen mainly and other nutrients for corn crop nutrition based on the knowledge of effluent nutrient concentrations. TSE split application through fertirrigation can lead to corn yield parameters close to those from NPK application using only mineral fertilizers as nutrient sources. The reuse of this wastewater is feasible for small-scale corn production which is typical of Brazilian smallholder farming.
- 17 July 2020
- Published by Springer Nature in SN Applied Sciences
- Vol. 2 (8) , 1-10
Single and combined toxicity of the pesticides abamectin and difenoconazole on soil microbial activity and Enchytraeus crypticus population
- 17 July 2020
- Published by Springer Nature in SN Applied Sciences
- Vol. 2 (8) , 1-10
Single and combined toxicity of the pesticides abamectin and difenoconazole on soil microbial activity and Enchytraeus crypticus population