Selcuk Bas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Selcuk Bas has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Chuan-Zhi Dong
Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL 32816, USA
2 shared publications - Fikret Necati Catbas
Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, USA
2 shared publications Murat Celiker
General Directory of State Hydraulics Works 9th Regional Directory Elazığ Türkiye
2 shared publications- Yetis Bulent Sonmezer
Department of Civil Engineering, Faculty of Engineering and Natural Sciences Kırıkkale University Kırıkkale Türkiye
2 shared publications - Alper Ilki
Istanbul Technical Univ
1 shared publication Bora Gencturk
Sonny Astani Department of Civil & Environmental Engineering University of Southern California Los Angeles CA USA
1 shared publication
Latest Publications
- Open Access
- 12 October 2026
- Published by Wiley in Structural Concrete
Strong ground motion and structural damage in the 2023 Kahramanmaraş earthquakes: A comparative case study of numerical predictions and field observations
On February 6, 2023, southeastern Türkiye was struck by two catastrophic earthquakes ( M w : 7.7 and M w : 7.6) along the East Anatolian Fault Zone, causing extensive structural failures and significant loss of life. This study evaluates the seismotectonic characteristics of the sequence, analyzes strong ground motion data against the Turkish Building Earthquake Code (TBEC‐2018) design spectra, and investigates the correlation between numerical performance predictions and observed field damage of a reinforced concrete building in Kırıkhan/Hatay. Ground motion data from affected provinces demonstrated peak ground accelerations exceeding code expectations by up to five times, particularly in areas with soft alluvial soils, amplifying seismic demands through site effects and near‐fault phenomena. A core contribution of this research is the detailed structural evaluation of a representative reinforced concrete building subjected to these extreme demands, incorporating experimental concrete compressive strengths derived from material tests and field‐verified reinforcement layouts. While nonlinear static assessments executed via macro‐level modeling tools successfully predicted global stability and “Collapse Prevention” status under DD‐1 and DD‐2 hazard levels, they failed to capture the brittle shear failures observed in short coupling beams and shear wall boundary elements. This divergence stems from the models' tendency to idealize ductile flexural response, overlooking localized brittle triggers exacerbated by poor workmanship, inadequate transverse reinforcement, and reinforcement debonding. These findings demonstrate that while macro‐level modeling effectively evaluates global structural safety, it must be coupled with shear‐sensitive formulations and localized damage criteria to accurately capture actual structural capacity during extreme seismic events.
- 12 October 2026
- Published by Wiley in Structural Concrete
Open AccessStrong ground motion and structural damage in the 2023 Kahramanmaraş earthquakes: A comparative case study of numerical predictions and field observations
On February 6, 2023, southeastern Türkiye was struck by two catastrophic earthquakes ( M w : 7.7 and M w : 7.6) along the East Anatolian Fault Zone, causing extensive structural failures and significant loss of life. This study evaluates the seismotectonic characteristics of the sequence, analyzes strong ground motion data against the Turkish Building Earthquake Code (TBEC‐2018) design spectra, and investigates the correlation between numerical performance predictions and observed field damage of a reinforced concrete building in Kırıkhan/Hatay. Ground motion data from affected provinces demonstrated peak ground accelerations exceeding code expectations by up to five times, particularly in areas with soft alluvial soils, amplifying seismic demands through site effects and near‐fault phenomena. A core contribution of this research is the detailed structural evaluation of a representative reinforced concrete building subjected to these extreme demands, incorporating experimental concrete compressive strengths derived from material tests and field‐verified reinforcement layouts. While nonlinear static assessments executed via macro‐level modeling tools successfully predicted global stability and “Collapse Prevention” status under DD‐1 and DD‐2 hazard levels, they failed to capture the brittle shear failures observed in short coupling beams and shear wall boundary elements. This divergence stems from the models' tendency to idealize ductile flexural response, overlooking localized brittle triggers exacerbated by poor workmanship, inadequate transverse reinforcement, and reinforcement debonding. These findings demonstrate that while macro‐level modeling effectively evaluates global structural safety, it must be coupled with shear‐sensitive formulations and localized damage criteria to accurately capture actual structural capacity during extreme seismic events.
- 27 July 2024
- Published by Wiley in Earthquake Spectra
- Vol. 40 (4) , 2339-2363
Seismic performance and damage assessment of bridges during the 2023 Kahramanmaras, Türkiye earthquakes ( M w = 7.8, M w = 7.6)
This article presents a summary of the damage observed in bridges in the regions affected by the 6 February 2023 Kahramanmaras, Türkiye earthquake sequence. A bridge database was developed based on the observations from multiple reconnaissance groups that visited the bridges. These reconnaissance groups collectively visited 140 individual bridges that were subjected to various intensities of ground shaking. The severity of the observed damage ranged from no damage to total collapse. The types of damage to bridge components mainly included cracking and shifting of abutments, failure of pier cap shear blocks, shifting or dislodging of bearing pads, cracking of girders and loss of prestress, plastic hinging at pier bases, residual pier drift, and distress to deck surfaces, handrails, and carried utilities. Recorded and estimated seismic intensity measures are presented for each bridge site, and statistical information and correlations were developed considering the intensity of shaking, bridge parameters, and observed damage. Observations from a few visited sites are presented as case studies to illustrate the common failure mechanisms. The bridge database and presented results are expected to serve as a reference for further analysis, such as statistical verification, correlation, or damage estimations, and discussion regarding the mitigation of the observed vulnerabilities of bridges in Türkiye and those with similar construction worldwide.
- 27 July 2024
- Published by Wiley in Earthquake Spectra
- Vol. 40 (4) , 2339-2363
Seismic performance and damage assessment of bridges during the 2023 Kahramanmaras, Türkiye earthquakes ( M w = 7.8, M w = 7.6)
This article presents a summary of the damage observed in bridges in the regions affected by the 6 February 2023 Kahramanmaras, Türkiye earthquake sequence. A bridge database was developed based on the observations from multiple reconnaissance groups that visited the bridges. These reconnaissance groups collectively visited 140 individual bridges that were subjected to various intensities of ground shaking. The severity of the observed damage ranged from no damage to total collapse. The types of damage to bridge components mainly included cracking and shifting of abutments, failure of pier cap shear blocks, shifting or dislodging of bearing pads, cracking of girders and loss of prestress, plastic hinging at pier bases, residual pier drift, and distress to deck surfaces, handrails, and carried utilities. Recorded and estimated seismic intensity measures are presented for each bridge site, and statistical information and correlations were developed considering the intensity of shaking, bridge parameters, and observed damage. Observations from a few visited sites are presented as case studies to illustrate the common failure mechanisms. The bridge database and presented results are expected to serve as a reference for further analysis, such as statistical verification, correlation, or damage estimations, and discussion regarding the mitigation of the observed vulnerabilities of bridges in Türkiye and those with similar construction worldwide.
- Open Access
Applications of Computer Vision-Based Structural Monitoring on Long-Span Bridges in Turkey
Structural displacement monitoring is one of the major tasks of structural health monitoring and it is a significant challenge for research and engineering practices relating to large-scale civil structures. While computer vision-based structural monitoring has gained traction, current practices largely focus on laboratory experiments, small-scale structures, or close-range applications. This paper demonstrates its applications on three landmark long-span suspension bridges in Turkey: the First Bosphorus Bridge, the Second Bosphorus Bridge, and the Osman Gazi Bridge, among the longest landmark bridges in the world, with main spans of 1074 m, 1090 m, and 1550 m, respectively. The presented studies achieved non-contact displacement monitoring from a distance of 600 m, 755 m, and 1350 m for the respective bridges. The presented concepts, analysis, and results provide an overview of long-span bridge monitoring using computer vision-based monitoring. The results are assessed with conventional monitoring approaches and finite element analysis based on observed traffic conditions. Both displacements and dynamic frequencies align well with these conventional techniques and finite element analyses. This study also highlights the challenges of computer vision-based structural monitoring of long-span bridges and presents considerations such as the encountered adverse environmental factors, target and algorithm selection, and potential directions of future studies.
Open AccessApplications of Computer Vision-Based Structural Monitoring on Long-Span Bridges in Turkey
Structural displacement monitoring is one of the major tasks of structural health monitoring and it is a significant challenge for research and engineering practices relating to large-scale civil structures. While computer vision-based structural monitoring has gained traction, current practices largely focus on laboratory experiments, small-scale structures, or close-range applications. This paper demonstrates its applications on three landmark long-span suspension bridges in Turkey: the First Bosphorus Bridge, the Second Bosphorus Bridge, and the Osman Gazi Bridge, among the longest landmark bridges in the world, with main spans of 1074 m, 1090 m, and 1550 m, respectively. The presented studies achieved non-contact displacement monitoring from a distance of 600 m, 755 m, and 1350 m for the respective bridges. The presented concepts, analysis, and results provide an overview of long-span bridge monitoring using computer vision-based monitoring. The results are assessed with conventional monitoring approaches and finite element analysis based on observed traffic conditions. Both displacements and dynamic frequencies align well with these conventional techniques and finite element analyses. This study also highlights the challenges of computer vision-based structural monitoring of long-span bridges and presents considerations such as the encountered adverse environmental factors, target and algorithm selection, and potential directions of future studies.
- 1 December 2021
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 24 (4) , 1647-1654
Estimation of Web Distortion Effect on the Elastic and Plastic Limiting Lengths for Lateral Torsional Buckling through the Web Strain Results
The present study is aimed to estimate the influence of the web distortion on the elastic (Lr) and plastic (Lp) limiting lengths given in the American Institute of Steel Construction (AISC code) for the lateral torsional buckling behavior of steel beams. For this aim, the W44x335 beam is adopted in the buckling analyses carried out by the ABAQUS finite element (FE) program. The strain results at mid-height of the web at mid-span of the beam are taken into account as monitoring parameters. The web strain results are found highly greater than the yield strain value when L/Lr is equal to 1.0. Hence, the elastic limiting length (Lr) is required to be considered greater than the calculated length as per the code formulation. The section is obtained to reach the maximum strain value at the web before the unbraced length (L) is equal to the plastic limiting length (Lp). Therefore, the calculated Lp is estimated with the given analytical formulation to be highly shorter than the length through the FE analysis. These outcomes prove that the formulations of the limiting lengths proposed in the AISC code don’t consider the influence of the web distortion that is predicted to lead to reducing the torsional and warping rigidity of the section. With the study, it is proposed to determine a reduction coefficient by performing more numerical analyzes for different cross sections and free openings in the regulation.
- 1 December 2021
- Published by Politeknik Dergisi in Journal of Polytechnic
- Vol. 24 (4) , 1647-1654
Estimation of Web Distortion Effect on the Elastic and Plastic Limiting Lengths for Lateral Torsional Buckling through the Web Strain Results
The present study is aimed to estimate the influence of the web distortion on the elastic (Lr) and plastic (Lp) limiting lengths given in the American Institute of Steel Construction (AISC code) for the lateral torsional buckling behavior of steel beams. For this aim, the W44x335 beam is adopted in the buckling analyses carried out by the ABAQUS finite element (FE) program. The strain results at mid-height of the web at mid-span of the beam are taken into account as monitoring parameters. The web strain results are found highly greater than the yield strain value when L/Lr is equal to 1.0. Hence, the elastic limiting length (Lr) is required to be considered greater than the calculated length as per the code formulation. The section is obtained to reach the maximum strain value at the web before the unbraced length (L) is equal to the plastic limiting length (Lp). Therefore, the calculated Lp is estimated with the given analytical formulation to be highly shorter than the length through the FE analysis. These outcomes prove that the formulations of the limiting lengths proposed in the AISC code don’t consider the influence of the web distortion that is predicted to lead to reducing the torsional and warping rigidity of the section. With the study, it is proposed to determine a reduction coefficient by performing more numerical analyzes for different cross sections and free openings in the regulation.
- 17 July 2020
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 49 (14) , 1496-1518
Hanger replacement influence on seismic response of suspension bridges: Implementation to the Bosphorus Bridge subjected to multi‐support excitation
Summary: The effects of hanger replacement from inclined to vertical configuration on seismic response of long‐span suspension bridges are investigated considering multi‐support earthquake excitation. The Bosphorus Bridge is investigated due to its recent comprehensive rehabilitation, mainly involving hanger replacement. The finite‐fault stochastic simulation method (FINSIM) is utilized for multi‐point earthquake time‐history generation. The developed finite element (FE) model both for the inclined and vertical hanger arrangement are verified through the structural health monitoring (SHM) data. Based on the comparative analysis, the tension force of vertical hangers is found to be lower than that of inclined hangers, whereas the tension force of the main and back‐stay cables remains the same. The compressive axial force of the deck decreases relatively in the case of the vertical hanger arrangement, whereas the cross‐sectional forces at the tower base section increase. The approach viaducts are not affected by the vertical hanger arrangement. According to the demand/capacity ratios for damage estimation under the max. earthquake (2475 years return period), structural damage on the tower base section may be expected for both hanger arrangements, while these sections perform well under design scenario earthquake. The expansion joint of the bridge with inclined hangers is also estimated to be damaged; however, this displacement is lower in the case of the vertical hanger arrangement due to the viscous dampers. The findings also reveal that a change in hanger form of a suspension bridge can necessitate other structural retrofit, such as using viscous dampers to limit longitudinal displacements of the deck and retrofitting the bridge towers.
- 17 July 2020
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 49 (14) , 1496-1518
Hanger replacement influence on seismic response of suspension bridges: Implementation to the Bosphorus Bridge subjected to multi‐support excitation
Summary: The effects of hanger replacement from inclined to vertical configuration on seismic response of long‐span suspension bridges are investigated considering multi‐support earthquake excitation. The Bosphorus Bridge is investigated due to its recent comprehensive rehabilitation, mainly involving hanger replacement. The finite‐fault stochastic simulation method (FINSIM) is utilized for multi‐point earthquake time‐history generation. The developed finite element (FE) model both for the inclined and vertical hanger arrangement are verified through the structural health monitoring (SHM) data. Based on the comparative analysis, the tension force of vertical hangers is found to be lower than that of inclined hangers, whereas the tension force of the main and back‐stay cables remains the same. The compressive axial force of the deck decreases relatively in the case of the vertical hanger arrangement, whereas the cross‐sectional forces at the tower base section increase. The approach viaducts are not affected by the vertical hanger arrangement. According to the demand/capacity ratios for damage estimation under the max. earthquake (2475 years return period), structural damage on the tower base section may be expected for both hanger arrangements, while these sections perform well under design scenario earthquake. The expansion joint of the bridge with inclined hangers is also estimated to be damaged; however, this displacement is lower in the case of the vertical hanger arrangement due to the viscous dampers. The findings also reveal that a change in hanger form of a suspension bridge can necessitate other structural retrofit, such as using viscous dampers to limit longitudinal displacements of the deck and retrofitting the bridge towers.
- 2 January 2019
- Published by Springer Nature in Bulletin of Engineering Geology and the Environment
- Vol. 78 (7) , 4689-4712
An investigation on the evaluation of dynamic soil characteristics of the Elazig City through the 1-D equivalent linear site-response analysis
- 2 January 2019
- Published by Springer Nature in Bulletin of Engineering Geology and the Environment
- Vol. 78 (7) , 4689-4712
An investigation on the evaluation of dynamic soil characteristics of the Elazig City through the 1-D equivalent linear site-response analysis
- 19 May 2018
- Published by Springer Nature in Natural Hazards
- Vol. 93 (3) , 1203-1229
Effects of the use of the surface spectrum of a specific region on seismic performances of R/C structures
- 19 May 2018
- Published by Springer Nature in Natural Hazards
- Vol. 93 (3) , 1203-1229
Effects of the use of the surface spectrum of a specific region on seismic performances of R/C structures
- 1 January 2017
- Published by International Association for Bridge and Structural Engineering (IABSE)
- Vol. 109, 159-166
Wind-induced Modal Identification of the Bosphorus Bridge using SHM-Structural Health Monitoring Data
Wind vibration characteristics of the Bosphorus Bridge is investigated using SHM data. The Bosphorus Bridge with the main span length of 1074 m and two side spans was instrumented due to the critical event in 2004 leading to damage to a hanger element. Totally 168 sensors were mounted on the bridge for its monitoring system. Due to the geographic location of Istanbul, strong winds are not expected for the bridges. However, the Bosphorus Bridge experienced a critical wind load in 2012, resulting in large displacement in transverse direction. During the event, wind speed reached to approximately 100 km/h from the average speed of 20 km/h within a short duration of 10 min. Therefore, it is significant to determine the influence of this event on the response of the bridge. For this objective, the data pre-processing including windowing and overlapping is first done to get rid of distorting effects of noise content on the data. The refined data, afterwards, is considered for structural identification of the bridge. Implementing the fundamental identification method of FFT, mode shapes and corresponding frequencies of the bridge are obtained. The comparison of the results during strong wind with those from after the extreme event showed that strong wind led to higher modal period values in the transverse and vertical modes, which can be attributed to a more flexible bridge behavior under this event. Along with the low modal frequencies obtained during the strong wind, the bridge is estimated to have high damping capacity under extreme loading. In addition, the modal frequencies obtained after the strong wind proves no damage to the bridge since these values are equal to natural vibration values of the bridge under normal operation conditions.
- 1 January 2017
- Published by International Association for Bridge and Structural Engineering (IABSE)
- Vol. 109, 159-166
Wind-induced Modal Identification of the Bosphorus Bridge using SHM-Structural Health Monitoring Data
Wind vibration characteristics of the Bosphorus Bridge is investigated using SHM data. The Bosphorus Bridge with the main span length of 1074 m and two side spans was instrumented due to the critical event in 2004 leading to damage to a hanger element. Totally 168 sensors were mounted on the bridge for its monitoring system. Due to the geographic location of Istanbul, strong winds are not expected for the bridges. However, the Bosphorus Bridge experienced a critical wind load in 2012, resulting in large displacement in transverse direction. During the event, wind speed reached to approximately 100 km/h from the average speed of 20 km/h within a short duration of 10 min. Therefore, it is significant to determine the influence of this event on the response of the bridge. For this objective, the data pre-processing including windowing and overlapping is first done to get rid of distorting effects of noise content on the data. The refined data, afterwards, is considered for structural identification of the bridge. Implementing the fundamental identification method of FFT, mode shapes and corresponding frequencies of the bridge are obtained. The comparison of the results during strong wind with those from after the extreme event showed that strong wind led to higher modal period values in the transverse and vertical modes, which can be attributed to a more flexible bridge behavior under this event. Along with the low modal frequencies obtained during the strong wind, the bridge is estimated to have high damping capacity under extreme loading. In addition, the modal frequencies obtained after the strong wind proves no damage to the bridge since these values are equal to natural vibration values of the bridge under normal operation conditions.