Seen-Young Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seen-Young Kang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ji-Hwan Kim
Department of Dental Laboratory Science and Engineering, Graduate School, Korea University, Seoul, Korea
7 shared publications - Ji-Min Yu
Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju-si 28159, Korea
3 shared publications - Jun-Seok Lee
Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju 28159, Republic of Korea
3 shared publications - Seung-Youl Lee
Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju 28159, Republic of Korea
3 shared publications - Woong-Chul Kim
Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, Seoul, Republic of Korea
3 shared publications - Jung-Hyun Park
Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University, 145, Anam-ro, Seoungbuk-gu, Seoul 136-712, Republic of Korea
2 shared publications
Latest Publications
- Open Access
Mechanical Properties of Dental Alloys According to Manufacturing Process
The purpose of this study is to investigate the effect of the fabrication method of dental prosthesis on the mechanical properties. Casting was produced using the lost wax casting method, and milling was designed using a CAD/CAM program. The 3D printing method used the SLS technique to create a three-dimensional structure by sintering metal powder with a laser. When making the specimen, the specimen was oriented at 0, 30, 60, and 90 degrees. All test specimens complied with the requirements of the international standard ISO 22674 for dental alloys. Tensile strength was measured for yield strength, modulus of elasticity and elongation by applying a load until fracture of the specimen at a crosshead speed of 1.5 ± 0.5 mm/min (n = 6, modulus of elasticity n = 3). After the tensile test, the cross section of the fractured specimen was observed with a scanning electron microscope, and the statistics of the data were analyzed with a statistical program SPSS (IBM Corp. Released 2020. IBM SPSS Statistics for Windows, Version 27.0. Armonk, NY, USA: IBM Corp.) and using Anova and multiple comparison post-tests (scheffe method). The yield strength was the highest at 1042 MPa at an angle of 0 degrees in the specimen produced by 3D printing method, and the elongation was the highest at 14% at an angle of 90 degrees in the specimen produced by 3D printing method. The modulus of elasticity was the highest at 235 GPa in the milled specimen. In particular, the 3D printing group showed a difference in yield strength and elongation according to the build direction. The introduction of various advanced technologies and digital equipment is expected to bring high prospects for the growth of the dental market.
Open AccessMechanical Properties of Dental Alloys According to Manufacturing Process
The purpose of this study is to investigate the effect of the fabrication method of dental prosthesis on the mechanical properties. Casting was produced using the lost wax casting method, and milling was designed using a CAD/CAM program. The 3D printing method used the SLS technique to create a three-dimensional structure by sintering metal powder with a laser. When making the specimen, the specimen was oriented at 0, 30, 60, and 90 degrees. All test specimens complied with the requirements of the international standard ISO 22674 for dental alloys. Tensile strength was measured for yield strength, modulus of elasticity and elongation by applying a load until fracture of the specimen at a crosshead speed of 1.5 ± 0.5 mm/min (n = 6, modulus of elasticity n = 3). After the tensile test, the cross section of the fractured specimen was observed with a scanning electron microscope, and the statistics of the data were analyzed with a statistical program SPSS (IBM Corp. Released 2020. IBM SPSS Statistics for Windows, Version 27.0. Armonk, NY, USA: IBM Corp.) and using Anova and multiple comparison post-tests (scheffe method). The yield strength was the highest at 1042 MPa at an angle of 0 degrees in the specimen produced by 3D printing method, and the elongation was the highest at 14% at an angle of 90 degrees in the specimen produced by 3D printing method. The modulus of elasticity was the highest at 235 GPa in the milled specimen. In particular, the 3D printing group showed a difference in yield strength and elongation according to the build direction. The introduction of various advanced technologies and digital equipment is expected to bring high prospects for the growth of the dental market.
- 1 March 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 125 (3) , 479-485
Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study
- 1 March 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 125 (3) , 479-485
Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study
- Open Access
- 1 January 2021
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 13 (1) , 24-35
Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study
Lee BI, et al. J Adv Prosthodont. 2021 Feb;13(1):24-35. https://doi.org/10.4047/jap.2021.13.1.24
- 1 January 2021
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 13 (1) , 24-35
Open AccessEffect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study
Lee BI, et al. J Adv Prosthodont. 2021 Feb;13(1):24-35. https://doi.org/10.4047/jap.2021.13.1.24
- Top Cited Papers
- 1 January 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 125 (1) , 139-145
Evaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: An in vitro study
- 1 January 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 125 (1) , 139-145
Top Cited PapersEvaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: An in vitro study
- Open Access
Evaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis
This study aimed to analyze the milling accuracy of lithium disilicate and zirconia-reinforced silicate crown fabricated using chairside computer-aided design/manufacturing (CAD/CAM) system. Mandibular left first premolar was selected for abutment. A master model was obtained for digital impression using an intraoral scanner, and crowns were designed using a CAD software design program. Amber Mill (AM), IPS e max CAD (IPS), and CELTRA DUO (CEL) were used in the CAD/CAM system, and a total 45 crowns (15 crowns each for AM, IPS, and CEL) was fabricated. Milling accuracy was analyzed with respect to trueness, measured by superimposing CAD design data and scan data through a three-dimensional program to compare the outer and inner surfaces and internal and external parts, thereby acquiring both quantitative and qualitative data. Data were analyzed using the non-parametric test and Kruskal–Wallis H test. In addition, the Mann–Whitney U test was used by applying the level of significance (0.05/3 = 0.016) adjusted by post-analysis Bonferroni correction. All the measured parts of the lithium disilicate and zirconia-reinforced silicate crowns showed statistically significant differences (p < 0.05). The lithium disilicate (AM and IPS) materials showed superior milling accuracy than the zirconia-reinforced lithium silicate (CEL) materials.
Open AccessEvaluation of the Milling Accuracy of Zirconia-Reinforced Lithium Silicate Crowns Fabricated Using the Dental Medical Device System: A Three-Dimensional Analysis
This study aimed to analyze the milling accuracy of lithium disilicate and zirconia-reinforced silicate crown fabricated using chairside computer-aided design/manufacturing (CAD/CAM) system. Mandibular left first premolar was selected for abutment. A master model was obtained for digital impression using an intraoral scanner, and crowns were designed using a CAD software design program. Amber Mill (AM), IPS e max CAD (IPS), and CELTRA DUO (CEL) were used in the CAD/CAM system, and a total 45 crowns (15 crowns each for AM, IPS, and CEL) was fabricated. Milling accuracy was analyzed with respect to trueness, measured by superimposing CAD design data and scan data through a three-dimensional program to compare the outer and inner surfaces and internal and external parts, thereby acquiring both quantitative and qualitative data. Data were analyzed using the non-parametric test and Kruskal–Wallis H test. In addition, the Mann–Whitney U test was used by applying the level of significance (0.05/3 = 0.016) adjusted by post-analysis Bonferroni correction. All the measured parts of the lithium disilicate and zirconia-reinforced silicate crowns showed statistically significant differences (p < 0.05). The lithium disilicate (AM and IPS) materials showed superior milling accuracy than the zirconia-reinforced lithium silicate (CEL) materials.
- Open Access
Influence of Orthodontic Anchor Screw Anchorage Method on the Stability of Artificial Bone: An In Vitro Study
This study aims to compare the torque values for various lengths of the titanium-based orthodontic anchor screw (OAS), different anchorage methods and varying artificial bone densities after predrilling. Furthermore, the effects of these parameters on bone stability are evaluated. A total of 144 OASs were prepared with a diameter of 1.6 mm and heights of 6, 8 and 10 mm. Artificial bones were selected according to their density, corresponding to Grades 50, 40 and 30. Torque values for the automatic device and manual anchorage methods exhibited a statistically significant difference for the same-sized OAS, according to the bone density of the artificial bones (p < 0.05). However, when insertion torque was at the maximum rotations, there was no significant difference in the torque values for the Grade 30 artificial bone (p > 0.05). When the torque values of both anchorage methods were statistically compared with the mean difference for each group, the results of the manual anchorage method were significantly higher than those of the automatic device anchorage method (p < 0.05). A statistically significant difference was observed in the bone stability resulting from different OAS anchorage methods and artificial bone lengths. These findings suggest that the automatic anchorage method should be used when fixing the OAS.
Open AccessInfluence of Orthodontic Anchor Screw Anchorage Method on the Stability of Artificial Bone: An In Vitro Study
This study aims to compare the torque values for various lengths of the titanium-based orthodontic anchor screw (OAS), different anchorage methods and varying artificial bone densities after predrilling. Furthermore, the effects of these parameters on bone stability are evaluated. A total of 144 OASs were prepared with a diameter of 1.6 mm and heights of 6, 8 and 10 mm. Artificial bones were selected according to their density, corresponding to Grades 50, 40 and 30. Torque values for the automatic device and manual anchorage methods exhibited a statistically significant difference for the same-sized OAS, according to the bone density of the artificial bones (p < 0.05). However, when insertion torque was at the maximum rotations, there was no significant difference in the torque values for the Grade 30 artificial bone (p > 0.05). When the torque values of both anchorage methods were statistically compared with the mean difference for each group, the results of the manual anchorage method were significantly higher than those of the automatic device anchorage method (p < 0.05). A statistically significant difference was observed in the bone stability resulting from different OAS anchorage methods and artificial bone lengths. These findings suggest that the automatic anchorage method should be used when fixing the OAS.
- 1 April 2020
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 64 (2) , 152-158
Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design/manufacturing system: An in vitro study
This study analyzed the trueness of polymer-infiltrated ceramic and glass ceramic crowns manufactured using the chairside computer-aided design/manufacturing (CAD/CAM) system. The master model designs crowns using a CAD program after acquiring a digital impression with an intraoral scanner. Vita Enamic (VE), Vita Suprinity (VS), and IPS e.max CAD (IPS) were used to manufacture 10 crowns each (total: 30 crowns), using the chairside CAD/CAM system (inLab MC XL). Trueness was evaluated by superimposing the CAD data on the scan data using a three-dimensional program. The Kruskal-Wallis H test, a nonparametric test, and the Mann-Whitney U test were performed by applying the significance level (0.05/3=0.016), which was adjusted by post-analysis Bonferroni testing. There was a significant difference in the trueness between the samples (p0.05). These findings show that the milling accuracy of VE is better than that of VS and IPS.
- 1 April 2020
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 64 (2) , 152-158
Three-dimensional trueness analysis of ceramic crowns fabricated using a chairside computer-aided design/manufacturing system: An in vitro study
This study analyzed the trueness of polymer-infiltrated ceramic and glass ceramic crowns manufactured using the chairside computer-aided design/manufacturing (CAD/CAM) system. The master model designs crowns using a CAD program after acquiring a digital impression with an intraoral scanner. Vita Enamic (VE), Vita Suprinity (VS), and IPS e.max CAD (IPS) were used to manufacture 10 crowns each (total: 30 crowns), using the chairside CAD/CAM system (inLab MC XL). Trueness was evaluated by superimposing the CAD data on the scan data using a three-dimensional program. The Kruskal-Wallis H test, a nonparametric test, and the Mann-Whitney U test were performed by applying the significance level (0.05/3=0.016), which was adjusted by post-analysis Bonferroni testing. There was a significant difference in the trueness between the samples (p0.05). These findings show that the milling accuracy of VE is better than that of VS and IPS.
- 31 December 2019
- Published by The Korean Magnetics Society in Journal of Magnetics
- Vol. 24 (4) , 733-738
A Study on Performance Evaluation of Magnetic Dental Attachments
- 31 December 2019
- Published by The Korean Magnetics Society in Journal of Magnetics
- Vol. 24 (4) , 733-738
A Study on Performance Evaluation of Magnetic Dental Attachments
- Open Access
- 18 December 2019
- Published by Springer Nature in BMC Oral Health
- Vol. 19 (1) , 1-9
Effect of core materials for core fabrication for dental implants on in-vitro cytocompatibility of MC3T3-E1 cells
Background: Despite the wide use of dental materials for CAD/CAM system in prosthetic treatment, the effect of the materials, which are used as dental implants core fabricated, on cells involved in dental implant osseointegration is uncertain. This study aimed to investigate and compare the effect of single core materials used for dental implants fabricated by the dental prostheses fabrication process and the CAD/CAM milling method on MC3T3-E1 cells. Methods: The materials used for prostheses restoration in this experiment were Porcelain Fused Gold (P.F.G), Lithium disilicate glass ceramic (LiSi2), Zirconia (ZrO2), Nickel-Chromium (Ni-Cr) and Cobalt-Chromium (Co-Cr). MC3T3-E1 cells were cultured and used, the cell adhesion and morphology were observed and analyzed using confocal laser scanning microscopy (CLSM). Methoxyphenyl tetrazolium salt (MTS) and alkaline phosphatase (ALP) assay were used to observe the cell proliferation and differentiation. Results: CLSM revealed irregular cell adhesion and morphology and the filopodia did not spread in the Ni-Cr specimen group. Significantly high cell proliferation was observed in the ZrO2 specimen group. The LiSi2 specimen group presented significantly high cell differentiation. Intergroup comparison of cell proliferation and differentiation between the Ni-Cr specimen group and all other specimen groups showed significant differences (p < .05). Conclusion: Cell proliferation and differentiation were observed from the cores, which were fabricated with all specimen groups on cytocompatibility except the Ni-Cr specimen group.
- 18 December 2019
- Published by Springer Nature in BMC Oral Health
- Vol. 19 (1) , 1-9
Open AccessEffect of core materials for core fabrication for dental implants on in-vitro cytocompatibility of MC3T3-E1 cells
Background: Despite the wide use of dental materials for CAD/CAM system in prosthetic treatment, the effect of the materials, which are used as dental implants core fabricated, on cells involved in dental implant osseointegration is uncertain. This study aimed to investigate and compare the effect of single core materials used for dental implants fabricated by the dental prostheses fabrication process and the CAD/CAM milling method on MC3T3-E1 cells. Methods: The materials used for prostheses restoration in this experiment were Porcelain Fused Gold (P.F.G), Lithium disilicate glass ceramic (LiSi2), Zirconia (ZrO2), Nickel-Chromium (Ni-Cr) and Cobalt-Chromium (Co-Cr). MC3T3-E1 cells were cultured and used, the cell adhesion and morphology were observed and analyzed using confocal laser scanning microscopy (CLSM). Methoxyphenyl tetrazolium salt (MTS) and alkaline phosphatase (ALP) assay were used to observe the cell proliferation and differentiation. Results: CLSM revealed irregular cell adhesion and morphology and the filopodia did not spread in the Ni-Cr specimen group. Significantly high cell proliferation was observed in the ZrO2 specimen group. The LiSi2 specimen group presented significantly high cell differentiation. Intergroup comparison of cell proliferation and differentiation between the Ni-Cr specimen group and all other specimen groups showed significant differences (p < .05). Conclusion: Cell proliferation and differentiation were observed from the cores, which were fabricated with all specimen groups on cytocompatibility except the Ni-Cr specimen group.
- Open Access
- 1 January 2018
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 10 (5) , 354-360
Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique
Kang SY, et al. J Adv Prosthodont. 2018 Oct;10(5):354-360. https://doi.org/10.4047/jap.2018.10.5.354
- 1 January 2018
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 10 (5) , 354-360
Open AccessAccuracy of provisional crowns made using stereolithography apparatus and subtractive technique
Kang SY, et al. J Adv Prosthodont. 2018 Oct;10(5):354-360. https://doi.org/10.4047/jap.2018.10.5.354