Pedro Henrique Pereira da Cunha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pedro Henrique Pereira da Cunha has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Roberto Filgueiras
Universidade Federal do Espirito Santo
6 shared publications - Ellisson Henrique de Paulo
XXVII Encontro Latino Americano de Iniciação Científica, XXIII Encontro Latino Americano de Pós-Graduação e XIII Encontro de Iniciação à Docência -Universidade do Vale do Paraíba -2023
3 shared publications - Gabriely Silveira Folli
Departamento of Chemistry, Federal University of Espírito Santo (UFES), Av. Fernando Ferrari, 514, Vitória, Espírito Santo 29075-910, Brazil
3 shared publications - Wanderson Romão
Federal University of Espírito Santo
3 shared publications Francine D. Santos
Universidade Federal do Espirito Santo
2 shared publications- Márcia Helena Cassago Nascimento
Universidade Federal do Espirito Santo
2 shared publications
Latest Publications
- Open Access
NIR-SC-UFES: A portable NIR spectral dataset to skin cancer in vivo
In recent years, significant progress has been made in computer-aided diagnostics (CAD) for skin lesions, primarily using images and metadata. However, these methods have limitations, particularly in revealing the molecular structure of lesions. NIR spectroscopy offers additional data, capturing information not visible to the naked eye, which can improve automated CAD for skin lesions. Skin cancer remains a major cause of death, making early diagnosis crucial. A key challenge in applying machine and deep learning (MDL) techniques to spectroscopy is the lack of publicly available datasets. Previously, no public dataset of portable NIR spectral data for skin lesions existed. In collaboration with the Programa de Assistência Dermatológica (PAD) at UFES, we developed a new dataset, NIR-SC-UFES, for skin cancer diagnosis. This dataset includes portable NIR spectral data for six lesion skin, with 714 spectra captured between 900 and 1700 nm. The dataset is available at data.mendeley.com/datasets/j9773cyr3k/1 . Graphical Specifications Table:
Open AccessNIR-SC-UFES: A portable NIR spectral dataset to skin cancer in vivo
In recent years, significant progress has been made in computer-aided diagnostics (CAD) for skin lesions, primarily using images and metadata. However, these methods have limitations, particularly in revealing the molecular structure of lesions. NIR spectroscopy offers additional data, capturing information not visible to the naked eye, which can improve automated CAD for skin lesions. Skin cancer remains a major cause of death, making early diagnosis crucial. A key challenge in applying machine and deep learning (MDL) techniques to spectroscopy is the lack of publicly available datasets. Previously, no public dataset of portable NIR spectral data for skin lesions existed. In collaboration with the Programa de Assistência Dermatológica (PAD) at UFES, we developed a new dataset, NIR-SC-UFES, for skin cancer diagnosis. This dataset includes portable NIR spectral data for six lesion skin, with 714 spectra captured between 900 and 1700 nm. The dataset is available at data.mendeley.com/datasets/j9773cyr3k/1 . Graphical Specifications Table:
- 9 August 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (33) , 4119-4133
Correlation analysis of modern analytical data – a chemometric dissection of spectral and chromatographic variables
The Standard Practices for Infrared Multivariate Quantitative Analysis (ASTM E1655) provide a guide for determining physicochemical properties of materials using multivariate calibration techniques applied to chemical sources that have high multicollinearity and correlated information. Partial least squares (PLS) is the most widely used multivariate regression method due to its excellent prediction capabilities and easy optimization. Initially applied to chromatographic data, PLS has also shown great results in near-infrared (NIR) and mid-infrared (MIR) spectroscopies. However, complex chemical matrices with low correlation may not be efficiently modeled using PLS or other multivariate analyses limited by grouping similar information (such as latent variables or principal components). Therefore, this study aims to evaluate the multicollinearity of different analytical techniques, such as high-temperature gas chromatography (HTGC), NIR, MIR, hydrogen nuclear magnetic resonance (1H NMR), carbon-13 nuclear magnetic resonance (13C NMR), and Fourier transform ion cyclotron resonance mass spectrometry coupled to the electrospray source in positive and negative ionization modes (ESI(±)FT-ICR). Descriptive statistics (coefficient of determination, R2) and principal component analysis (PCA) were used to identify the distribution of correlated information. Results showed that NIR and MIR spectroscopies exhibited a higher percentage of correlated variables, while 13C NMR and ESI(±)FT-ICR MS had more discrete profiles. Therefore, PLS development may be more effectively applied to NIR, MIR, and 1H NMR data, while 13C NMR and mass spectra may require other algorithms or variable selection methods in combination with PLS.
- 9 August 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (33) , 4119-4133
Correlation analysis of modern analytical data – a chemometric dissection of spectral and chromatographic variables
The Standard Practices for Infrared Multivariate Quantitative Analysis (ASTM E1655) provide a guide for determining physicochemical properties of materials using multivariate calibration techniques applied to chemical sources that have high multicollinearity and correlated information. Partial least squares (PLS) is the most widely used multivariate regression method due to its excellent prediction capabilities and easy optimization. Initially applied to chromatographic data, PLS has also shown great results in near-infrared (NIR) and mid-infrared (MIR) spectroscopies. However, complex chemical matrices with low correlation may not be efficiently modeled using PLS or other multivariate analyses limited by grouping similar information (such as latent variables or principal components). Therefore, this study aims to evaluate the multicollinearity of different analytical techniques, such as high-temperature gas chromatography (HTGC), NIR, MIR, hydrogen nuclear magnetic resonance (1H NMR), carbon-13 nuclear magnetic resonance (13C NMR), and Fourier transform ion cyclotron resonance mass spectrometry coupled to the electrospray source in positive and negative ionization modes (ESI(±)FT-ICR). Descriptive statistics (coefficient of determination, R2) and principal component analysis (PCA) were used to identify the distribution of correlated information. Results showed that NIR and MIR spectroscopies exhibited a higher percentage of correlated variables, while 13C NMR and ESI(±)FT-ICR MS had more discrete profiles. Therefore, PLS development may be more effectively applied to NIR, MIR, and 1H NMR data, while 13C NMR and mass spectra may require other algorithms or variable selection methods in combination with PLS.
- 20 June 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (29) , 3499-3509
SHS-GC-MS applied in Coffea arabica and Coffea canephora blend assessment
Considering the great economic significance of Coffea arabica (arabica) associated with the lower production cost of C. canephora (conilon), blends of these coffees are commercially available to reduce costs and combine sensory attributes. Thus, analytical tools are required to ensure consistency between real and labeled compositions. In this sense, chromatographic methods based on volatile analysis using static headspace-gas chromatography-mass spectrometry (SHS-GC-MS) and Fourier transform infrared (FTIR) spectroscopy associated with chemometric tools were proposed for the identification and quantification of arabica and conilon blends. The peak integration from the total ion chromatogram (TIC) and extracted ion chromatogram (EIC) was compared in multivariate and univariate scenarios. The optimized partial least squares (PLS) models with uninformative variable elimination (UVE) and chromatographic data (TIC and EIC) have similar accuracy according to a randomized test, with prediction errors between 3.3% and 4.7% and Rp 2 > 0.98. There was no difference between the univariate models for the TIC and EIC, but the FTIR model presented a lower performance than GC-MS. The multivariate and univariate models based on chromatographic data had similar accuracy. For the classification models, the FTIR, TIC, and EIC data presented accuracies from 96% to 100% and error rates from 0% to 5%. Multivariate and univariate analyses combined with chromatographic and spectroscopic data allow the investigation of coffee blends.
- 20 June 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (29) , 3499-3509
SHS-GC-MS applied in Coffea arabica and Coffea canephora blend assessment
Considering the great economic significance of Coffea arabica (arabica) associated with the lower production cost of C. canephora (conilon), blends of these coffees are commercially available to reduce costs and combine sensory attributes. Thus, analytical tools are required to ensure consistency between real and labeled compositions. In this sense, chromatographic methods based on volatile analysis using static headspace-gas chromatography-mass spectrometry (SHS-GC-MS) and Fourier transform infrared (FTIR) spectroscopy associated with chemometric tools were proposed for the identification and quantification of arabica and conilon blends. The peak integration from the total ion chromatogram (TIC) and extracted ion chromatogram (EIC) was compared in multivariate and univariate scenarios. The optimized partial least squares (PLS) models with uninformative variable elimination (UVE) and chromatographic data (TIC and EIC) have similar accuracy according to a randomized test, with prediction errors between 3.3% and 4.7% and Rp 2 > 0.98. There was no difference between the univariate models for the TIC and EIC, but the FTIR model presented a lower performance than GC-MS. The multivariate and univariate models based on chromatographic data had similar accuracy. For the classification models, the FTIR, TIC, and EIC data presented accuracies from 96% to 100% and error rates from 0% to 5%. Multivariate and univariate analyses combined with chromatographic and spectroscopic data allow the investigation of coffee blends.
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Revista Virtual de Química
- Vol. 15 (6) , 1070-1080
Use of Remote Sensing and Chemometrics as Tools to Estimate Parameters of Water Quality in Intermittent Lakes of the Lower Doce River
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Revista Virtual de Química
- Vol. 15 (6) , 1070-1080
Use of Remote Sensing and Chemometrics as Tools to Estimate Parameters of Water Quality in Intermittent Lakes of the Lower Doce River
- 26 September 2022
- Published by Wiley in Journal of Chemometrics
- Vol. 36 (10)
Variable selection by permutation applied in support vector regression models
Support vector regression (SVR) can be considered as a black box machine‐learning method. Thus, identifying the cause/effect relationship and the synergism between the most important variables is a difficult task. This study demonstrates the potential of two variable selection methods by permutation—subwindow permutation analysis (SPA) and noise incorporated subwindow permutation analysis (NISPA)—to overcome this limitation. The application of these two variable selections in SVR is poorly explored in literature, mainly for regression problems. The algorithms were applied in FTIR (Fourier transform mid infrared spectroscopy) data of crude oil samples to estimate API gravity, kinematic viscosity at 50°C, saturates, aromatics, resins, and asphaltene content. The results were compared to other variable selection methods. SPA and NISPA provided the most accurate models for kinematic viscosity, saturates, and aromatic content. The root‐mean‐squared percentage error of prediction (RMSPEP) of the SPA and NISPA were, respectively, 14.26% and 14.62% for kinematic viscosity, 4.7 wt% and 4.4 wt% for saturates content, and 3.4 wt% and 3.1 wt% for aromatic content. Regarding API prediction, despite obtaining similar accuracy to the other selection methods, SPA produced a more simplified model, using only 3.5% of the 3351 total variables, with RMSEP equal to 1.0 and R2p to 0.981. Therefore, SPA and NISPA, besides obtaining, in general, faster and more accurate and parsimonious models, revealed the most important variables for building the SVR models.
- 26 September 2022
- Published by Wiley in Journal of Chemometrics
- Vol. 36 (10)
Variable selection by permutation applied in support vector regression models
Support vector regression (SVR) can be considered as a black box machine‐learning method. Thus, identifying the cause/effect relationship and the synergism between the most important variables is a difficult task. This study demonstrates the potential of two variable selection methods by permutation—subwindow permutation analysis (SPA) and noise incorporated subwindow permutation analysis (NISPA)—to overcome this limitation. The application of these two variable selections in SVR is poorly explored in literature, mainly for regression problems. The algorithms were applied in FTIR (Fourier transform mid infrared spectroscopy) data of crude oil samples to estimate API gravity, kinematic viscosity at 50°C, saturates, aromatics, resins, and asphaltene content. The results were compared to other variable selection methods. SPA and NISPA provided the most accurate models for kinematic viscosity, saturates, and aromatic content. The root‐mean‐squared percentage error of prediction (RMSPEP) of the SPA and NISPA were, respectively, 14.26% and 14.62% for kinematic viscosity, 4.7 wt% and 4.4 wt% for saturates content, and 3.4 wt% and 3.1 wt% for aromatic content. Regarding API prediction, despite obtaining similar accuracy to the other selection methods, SPA produced a more simplified model, using only 3.5% of the 3351 total variables, with RMSEP equal to 1.0 and R2p to 0.981. Therefore, SPA and NISPA, besides obtaining, in general, faster and more accurate and parsimonious models, revealed the most important variables for building the SVR models.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Characterization of Crude Oils with a Portable Nir Spectrometer
The characterization of oils by the physicochemical properties analyses is the basis of the industrial chain. Multivariate data analysis seeks to optimize this process through a characterization database. Thus, it is possible to build different models that estimate all these properties with only a data set from a spectroscopic technique. Near-infrared (NIR) spectroscopy is widely used for this purpose. However, there are no studies in the literature using a portable instrument – a technological advance interesting, for example, in field situations. In this study, we evaluate the performance of a portable NIR spectrometer and compare it with a benchtop NIR instrument. We estimate API gravity (ºAPI), total sulfur content (TSC), basic nitrogen content (BNC), saturates hydrocarbons (Sat), aromatics (Aro), resins (Res), and asphaltenes (Asp) from a set of 182 Brazilian crude oil samples. We constructed partial least squares (PLS) and support vector regression (SVR) models. The Asp model obtained the best response with the portable instrument in the wavenumber range from 11,000 cm –1 to 6,000 cm –1 . However, for the other properties, the benchtop instrument was superior because operates in the range from 10,000 cm –1 to 4,000 cm –1 . The range from 6,000 cm –1 to 4,000 cm –1 is important because it presents the first overtones of S-H, O-H, C-H, and N-H bonds. With the application of the SVR algorithm, it was possible to improve the results with the data from the portable instrument. The results obtained with SVR were similar or superior (Sat, Aro, and Asp) to those obtained with the data from the benchtop instrument. However, the Sat, Aro, and Res models still obtained a coefficient of determination (R 2 ) below 0.7. Even so, the portable instrument has applicability to petroleum analysis. It showed satisfactory results to estimate the properties ºAPI, TSC, BNC, and Asp.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessCharacterization of Crude Oils with a Portable Nir Spectrometer
The characterization of oils by the physicochemical properties analyses is the basis of the industrial chain. Multivariate data analysis seeks to optimize this process through a characterization database. Thus, it is possible to build different models that estimate all these properties with only a data set from a spectroscopic technique. Near-infrared (NIR) spectroscopy is widely used for this purpose. However, there are no studies in the literature using a portable instrument – a technological advance interesting, for example, in field situations. In this study, we evaluate the performance of a portable NIR spectrometer and compare it with a benchtop NIR instrument. We estimate API gravity (ºAPI), total sulfur content (TSC), basic nitrogen content (BNC), saturates hydrocarbons (Sat), aromatics (Aro), resins (Res), and asphaltenes (Asp) from a set of 182 Brazilian crude oil samples. We constructed partial least squares (PLS) and support vector regression (SVR) models. The Asp model obtained the best response with the portable instrument in the wavenumber range from 11,000 cm –1 to 6,000 cm –1 . However, for the other properties, the benchtop instrument was superior because operates in the range from 10,000 cm –1 to 4,000 cm –1 . The range from 6,000 cm –1 to 4,000 cm –1 is important because it presents the first overtones of S-H, O-H, C-H, and N-H bonds. With the application of the SVR algorithm, it was possible to improve the results with the data from the portable instrument. The results obtained with SVR were similar or superior (Sat, Aro, and Asp) to those obtained with the data from the benchtop instrument. However, the Sat, Aro, and Res models still obtained a coefficient of determination (R 2 ) below 0.7. Even so, the portable instrument has applicability to petroleum analysis. It showed satisfactory results to estimate the properties ºAPI, TSC, BNC, and Asp.
- 18 July 2020
- Published by Wiley in Journal of Chemometrics
- Vol. 34 (12)
Variable selection in support vector regression using angular search algorithm and variance inflation factor
Here, we combine angular search algorithm and variance inflation factor (ASA‐VIF) with support vector regression (SVR) (ASA‐VIF‐SVR) to estimate total acid number (TAN), basic nitrogen content (BNC), and sulfur content (SC) in Brazilian crude oils. To prevent the interference of outliers, we further developed a strategy for outlier identification and applied it to nonlinear models based on RMSE (root mean square error). ASA‐VIF‐SVR was applied to near‐ and mid‐infrared spectroscopy (NIR and MIR) and hydrogen nuclear magnetic resonance (1H NMR) spectroscopy data available in a range of 93–194 samples. The models were evaluated for accuracy (root mean square error of calibration [RMSEC] and root mean square error of prediction [RMSEP]) and linearity (coefficient of determination, R2). The removal of outliers increased accuracy and linearity of our models. The ASA‐VIF model for TAN, BNC, and SC selected 0.37%, 0.93%, and 0.30% of variables from full NIR spectra; 0.21%, 0.27%, and 0.21% from full MIR; and 0.20%, 0.42%, and 0.15% from full 1H NMR. In most cases, the best results were obtained with variable selection compared with the full dataset. Also, 1H NMR generated more accurate and linear models with RMSEP and R2p of 0.0071 wt% and 0.86 for BNC and 0.0623 wt% and 0.79 for SC. TAN showed a better MIR result with RMSEP of 0.1426 mg KOH g–1 and R2p of 0.47. The most important region for 1H NMR and MIR was the one with the largest quantity of unpaired electrons (aromatic region).
- 18 July 2020
- Published by Wiley in Journal of Chemometrics
- Vol. 34 (12)
Variable selection in support vector regression using angular search algorithm and variance inflation factor
Here, we combine angular search algorithm and variance inflation factor (ASA‐VIF) with support vector regression (SVR) (ASA‐VIF‐SVR) to estimate total acid number (TAN), basic nitrogen content (BNC), and sulfur content (SC) in Brazilian crude oils. To prevent the interference of outliers, we further developed a strategy for outlier identification and applied it to nonlinear models based on RMSE (root mean square error). ASA‐VIF‐SVR was applied to near‐ and mid‐infrared spectroscopy (NIR and MIR) and hydrogen nuclear magnetic resonance (1H NMR) spectroscopy data available in a range of 93–194 samples. The models were evaluated for accuracy (root mean square error of calibration [RMSEC] and root mean square error of prediction [RMSEP]) and linearity (coefficient of determination, R2). The removal of outliers increased accuracy and linearity of our models. The ASA‐VIF model for TAN, BNC, and SC selected 0.37%, 0.93%, and 0.30% of variables from full NIR spectra; 0.21%, 0.27%, and 0.21% from full MIR; and 0.20%, 0.42%, and 0.15% from full 1H NMR. In most cases, the best results were obtained with variable selection compared with the full dataset. Also, 1H NMR generated more accurate and linear models with RMSEP and R2p of 0.0071 wt% and 0.86 for BNC and 0.0623 wt% and 0.79 for SC. TAN showed a better MIR result with RMSEP of 0.1426 mg KOH g–1 and R2p of 0.47. The most important region for 1H NMR and MIR was the one with the largest quantity of unpaired electrons (aromatic region).