Leon Schild
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Leon Schild has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jens Greve
Department of Otorhinolaryngology, Head and Neck Surgery, Ulm University Medical Center, Ulm, Germany
4 shared publications - Felix Böhm
Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Centre Ulm, Ulm, Germany
3 shared publications - Patrick J. Schuler
Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty Heidelberg, University Hospital Heidelberg, Heidelberg, Germany
3 shared publications Thomas K. Hoffmann
Department of Otorhinolaryngology, Head and Neck Surgery Ulm University Medical Centre Ulm Germany
3 shared publicationsFelix Böhm
Universitätsklinikum Ulm, Klinik für Hals-Nasen-Ohrenheilkunde, Kopf- und HalschirurgieUlm
2 shared publications- Linus L. Kienle
Computer Vision & Graphics, Vision and Imaging Technologies, Fraunhofer Heinrich Hertz Institut, HHI, Berlin, Germany; Department of Othorinolaryngology, Head and Neck Surgery, Interdisciplinary Skull Base Center, Klinikum Fulda GAG, University Medicine Marburg, Campus Fulda, Germany
2 shared publications
Latest Publications
- Open Access
- 2 June 2025
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 10 (3)
A Comparative Evaluation of Three Different Attachment Methods for a Video Laryngoscope in a Surgical Setting
Introduction: The prerequisite for transoral microsurgery of laryngeal lesions is an uninterrupted line of sight to the operative field. Patients with cervical stiffness or anatomical variations that prevent adequate laryngeal exposure are typically unsuitable for this procedure. In such cases, a curved video laryngoscope may facilitate improved access to the larynx. However, conventional suspension laryngoscopy setups are incompatible with standard video laryngoscopes.Objective: This study evaluates three attachment methods for integrating a curved video laryngoscope into a surgical setup, focusing on their resistance to external forces.Methods: This study assessed three different attachment methods (3D‐printed clamp vs. metal bracket vs. articulated stand) for a video laryngoscope in a surgical setup. External forces, both lateral and rotational (torque), were applied and continuously measured until laryngeal visualization was compromised by displacement of the video laryngoscope.Results: The metal bracket demonstrated significantly (p < 0.001) higher resistance to lateral forces (median 184.49 N, 95% CI [181.59–189.61 N]) compared to the articulated stand (median 88.16 N, 95% CI [76.73–88.98 N]) and the 3D‐printed clamp (median 55.59 N, 95% CI [54.74–57.58 N]). The articulated stand exhibited significantly (p < 0.005) greater torque resistance (median 9.57 N m, 95% CI [5.65–9.87 N m]) compared to the metal bracket (median 1.58 N m, 95% CI [1.57–2.13 N m]) and the 3D‐printed clamp (median 2.46 N m, 95% CI [2.24–2.79 N m]).Conclusion: Overall, the articulated stand outperformed the other attachment methods, displaying robust resistance to lateral forces and superior rotational stability.Level of Evidence: Level 4.
- 2 June 2025
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 10 (3)
Open AccessA Comparative Evaluation of Three Different Attachment Methods for a Video Laryngoscope in a Surgical Setting
Introduction: The prerequisite for transoral microsurgery of laryngeal lesions is an uninterrupted line of sight to the operative field. Patients with cervical stiffness or anatomical variations that prevent adequate laryngeal exposure are typically unsuitable for this procedure. In such cases, a curved video laryngoscope may facilitate improved access to the larynx. However, conventional suspension laryngoscopy setups are incompatible with standard video laryngoscopes.Objective: This study evaluates three attachment methods for integrating a curved video laryngoscope into a surgical setup, focusing on their resistance to external forces.Methods: This study assessed three different attachment methods (3D‐printed clamp vs. metal bracket vs. articulated stand) for a video laryngoscope in a surgical setup. External forces, both lateral and rotational (torque), were applied and continuously measured until laryngeal visualization was compromised by displacement of the video laryngoscope.Results: The metal bracket demonstrated significantly (p < 0.001) higher resistance to lateral forces (median 184.49 N, 95% CI [181.59–189.61 N]) compared to the articulated stand (median 88.16 N, 95% CI [76.73–88.98 N]) and the 3D‐printed clamp (median 55.59 N, 95% CI [54.74–57.58 N]). The articulated stand exhibited significantly (p < 0.005) greater torque resistance (median 9.57 N m, 95% CI [5.65–9.87 N m]) compared to the metal bracket (median 1.58 N m, 95% CI [1.57–2.13 N m]) and the 3D‐printed clamp (median 2.46 N m, 95% CI [2.24–2.79 N m]).Conclusion: Overall, the articulated stand outperformed the other attachment methods, displaying robust resistance to lateral forces and superior rotational stability.Level of Evidence: Level 4.
- Open Access
- 24 May 2022
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 101 (S 02) , S23
Ein neuartiges Assistenz-Sytem für die transorale Larynx-Chirurgie
Einführung Die transorale Laserchirurgie stellt das Standardverfahren in der operativen Behandlung des Larynx-Karzinoms dar. Die notwendige Überstreckung der Halswirbelsäule zur Herstellung der geraden Sichtlinie ist jedoch nicht bei allen Patienten durchführbar. Ein nichtlineares Assistenzsystem könnte bei diesen Patienten einen besseren Zugang zum Kehlkopf ermöglichen. Methoden Wir präsentieren den Prototyp eines selbst konstruierten Assistenzsystems für die transorale Larynxchirurgie. Der 3D-gedruckte Prototyp ist ein nicht-lineares Laryngoskop mit drei Kanälen für ein flexibles Videolaryngoskop und zwei flexible Instrumente. Der Zugang und die Visualisierung des Kehlkopfes wurden in einer Anwenderstudie (n=19) im Tiermodell (porciner Larynx) und an einem Intubationsdummy evaluiert. Darüber hinaus wurden chirurgische Scheinverfahren an einem menschlichen Körperspender durchgeführt. Ergebnisse Im Tiermodell korrelierte die Zeit bis zum Erreichen aller anatomischen Landmarken im Kehlkopf mit der Erfahrung der Teilnehmer (49s vs. 91s). Um die chirurgischen Instrumente in die optimale Position für eine simulierte Chordektomie zu bringen, betrug die Zeit 128s±32s. Im Intubationsdummy war der Zugang zum Larynx auch nach Einschränkung der HWS-Reklination noch möglich. Beim menschlichen Körperspender war der Prototyp bei der Darstellung des Kehlkopfes einem Standard-Laryngoskop überlegen. Zusammenfassung In präklinischen Tests bietet das chirurgische Assistenzsystem die Möglichkeit, Kehlkopfstrukturen nichtlinear zu manipulieren. Dies kann in Zukunft eine kostengünstige, minimal-invasive Alternative bei unzureichender Kehlkopfexposition darstellen. Basierend auf diesen Ergebnissen wird eine klinische Pilotstudie initiiert. Article published online: 24 May 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
- 24 May 2022
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 101 (S 02) , S23
Open AccessEin neuartiges Assistenz-Sytem für die transorale Larynx-Chirurgie
Einführung Die transorale Laserchirurgie stellt das Standardverfahren in der operativen Behandlung des Larynx-Karzinoms dar. Die notwendige Überstreckung der Halswirbelsäule zur Herstellung der geraden Sichtlinie ist jedoch nicht bei allen Patienten durchführbar. Ein nichtlineares Assistenzsystem könnte bei diesen Patienten einen besseren Zugang zum Kehlkopf ermöglichen. Methoden Wir präsentieren den Prototyp eines selbst konstruierten Assistenzsystems für die transorale Larynxchirurgie. Der 3D-gedruckte Prototyp ist ein nicht-lineares Laryngoskop mit drei Kanälen für ein flexibles Videolaryngoskop und zwei flexible Instrumente. Der Zugang und die Visualisierung des Kehlkopfes wurden in einer Anwenderstudie (n=19) im Tiermodell (porciner Larynx) und an einem Intubationsdummy evaluiert. Darüber hinaus wurden chirurgische Scheinverfahren an einem menschlichen Körperspender durchgeführt. Ergebnisse Im Tiermodell korrelierte die Zeit bis zum Erreichen aller anatomischen Landmarken im Kehlkopf mit der Erfahrung der Teilnehmer (49s vs. 91s). Um die chirurgischen Instrumente in die optimale Position für eine simulierte Chordektomie zu bringen, betrug die Zeit 128s±32s. Im Intubationsdummy war der Zugang zum Larynx auch nach Einschränkung der HWS-Reklination noch möglich. Beim menschlichen Körperspender war der Prototyp bei der Darstellung des Kehlkopfes einem Standard-Laryngoskop überlegen. Zusammenfassung In präklinischen Tests bietet das chirurgische Assistenzsystem die Möglichkeit, Kehlkopfstrukturen nichtlinear zu manipulieren. Dies kann in Zukunft eine kostengünstige, minimal-invasive Alternative bei unzureichender Kehlkopfexposition darstellen. Basierend auf diesen Ergebnissen wird eine klinische Pilotstudie initiiert. Article published online: 24 May 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 24 May 2022
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 101 (S 02) , S243-S244
A novel assistant system for transoral surgery of the larynx
Introduction Transoral laser surgery is the standard procedure in the treatment of larynx cancer. However, the compulsory overstretching of the cervical spine to establish a straight line of sight is not feasible for all patients. A non-linear assistance system could provide better access to the larynx in these patients. Methods We present the prototype of a self-designed assistance system for transoral larynx surgery. The 3D-printed prototype is a non-linear laryngoscope with three channels for a flexible video laryngoscope and two flexible instruments. Access and visualization of the larynx were evaluated in a user study (n = 19) in an animal model and on an intubation dummy. In addition, sham surgical procedures were carried out on a human donor body. Results In the animal model, the time to reach all anatomical landmarks in the larynx correlated with the experience of the participants (49s vs. 91s). Bringing the surgical instruments into the optimal position for a simulated cordectomy, the time was 128s ± 32s. In the intubation dummy, access to the larynx was still possible even after the cervical spine reclination was restricted. In the case of human donors, the prototype was superior to a standard laryngoscope for displaying the larynx. Summary In preclinical tests, the surgical assistance system offers the possibility of manipulating larynx structures non-linearly. In the future, this may represent a cost-effective, minimally invasive alternative in the case of insufficient larynx exposure. A clinical pilot study will be initiated based on these results. Lumendi Ltd. und Karl Storz SE & Co. KG Conflict of InterestDer Erstautor weist auf folgenden Interessenkonflikt hin: Materielle Unterstützung durch Lumendi Ltd. und Karl Storz SE & Co. KG Article published online: 24 May 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart,Germany
- 24 May 2022
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 101 (S 02) , S243-S244
Open AccessA novel assistant system for transoral surgery of the larynx
Introduction Transoral laser surgery is the standard procedure in the treatment of larynx cancer. However, the compulsory overstretching of the cervical spine to establish a straight line of sight is not feasible for all patients. A non-linear assistance system could provide better access to the larynx in these patients. Methods We present the prototype of a self-designed assistance system for transoral larynx surgery. The 3D-printed prototype is a non-linear laryngoscope with three channels for a flexible video laryngoscope and two flexible instruments. Access and visualization of the larynx were evaluated in a user study (n = 19) in an animal model and on an intubation dummy. In addition, sham surgical procedures were carried out on a human donor body. Results In the animal model, the time to reach all anatomical landmarks in the larynx correlated with the experience of the participants (49s vs. 91s). Bringing the surgical instruments into the optimal position for a simulated cordectomy, the time was 128s ± 32s. In the intubation dummy, access to the larynx was still possible even after the cervical spine reclination was restricted. In the case of human donors, the prototype was superior to a standard laryngoscope for displaying the larynx. Summary In preclinical tests, the surgical assistance system offers the possibility of manipulating larynx structures non-linearly. In the future, this may represent a cost-effective, minimally invasive alternative in the case of insufficient larynx exposure. A clinical pilot study will be initiated based on these results. Lumendi Ltd. und Karl Storz SE & Co. KG Conflict of InterestDer Erstautor weist auf folgenden Interessenkonflikt hin: Materielle Unterstützung durch Lumendi Ltd. und Karl Storz SE & Co. KG Article published online: 24 May 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag Rüdigerstraße 14, 70469 Stuttgart,Germany
- Open Access
Current Advances in Robotics for Head and Neck Surgery—A Systematic Review
Background. In the past few years, surgical robots have recently entered the medical field, particularly in urology, gynecology, and general surgery. However, the clinical effectiveness and safety of robot-assisted surgery (RAS) in the field of head and neck surgery has not been clearly established. In this review, we evaluate to what extent RAS can potentially be applied in head and neck surgery, in which fields it is already daily routine and what advantages can be seen in comparison to conventional surgery. Data sources. For this purpose, we conducted a systematic review of trials published between 2000 and 2021, as well as currently ongoing trials registered in clinicaltrials.gov. The results were structured according to anatomical regions, for the topics “Costs,” “current clinical trials,” and “robotic research” we added separate sections for the sake of clarity. Results. Our findings show a lack of large-scale systematic randomized trials on the use of robots in head and neck surgery. Most studies include small case series or lack a control arm which enables a comparison with established standard procedures. Conclusion. The question of financial reimbursement is still not answered and the systems on the market still require some specific improvements for the use in head and neck surgery.
Open AccessCurrent Advances in Robotics for Head and Neck Surgery—A Systematic Review
Background. In the past few years, surgical robots have recently entered the medical field, particularly in urology, gynecology, and general surgery. However, the clinical effectiveness and safety of robot-assisted surgery (RAS) in the field of head and neck surgery has not been clearly established. In this review, we evaluate to what extent RAS can potentially be applied in head and neck surgery, in which fields it is already daily routine and what advantages can be seen in comparison to conventional surgery. Data sources. For this purpose, we conducted a systematic review of trials published between 2000 and 2021, as well as currently ongoing trials registered in clinicaltrials.gov. The results were structured according to anatomical regions, for the topics “Costs,” “current clinical trials,” and “robotic research” we added separate sections for the sake of clarity. Results. Our findings show a lack of large-scale systematic randomized trials on the use of robots in head and neck surgery. Most studies include small case series or lack a control arm which enables a comparison with established standard procedures. Conclusion. The question of financial reimbursement is still not answered and the systems on the market still require some specific improvements for the use in head and neck surgery.
- Open Access
- 25 June 2020
- Published by Wiley in The Laryngoscope
- Vol. 131 (2) , E561-E568
Adding Flexible Instrumentation to a Curved Videolaryngoscope: A Novel Tool for Laryngeal Surgery
Objectives: Transoral surgery of the larynx with rigid instruments is not always possible. This may result in insufficient therapy or in an increased need for open surgery. For these patients, alternative surgical systems are needed. Here, we demonstrate a curved prototype for laryngeal surgery equipped with flexible instruments.Study Design: Pre‐clinical user study in an ex vivo porcine laryngeal model.Methods: The prototype was built from established medical devices, namely a hyperangulated videolaryngoscope and modified flexible instruments as well as three‐dimensional printed parts. Feasibility of laryngeal manipulation was evaluated in a user study (n = 19) with a porcine ex vivo laryngeal model. Using three different visualization technologies, the participants performed various fine motor skills tasks and rated the usability of the system on a 5‐point Likert scale.Results: Exposure, accessibility, and manipulation of important laryngeal structures were always possible using the new prototype. The participants needed considerably less time (mean, 96.4 seconds ± 6.4 seconds vs. 111.5 seconds ± 4.5 seconds, P = .18), reported significantly better general impression (mean score 3.0 vs. 3.8, P = .041) and significantly lower user head and neck strain (2.6 vs. 1.7, P = .022) using a 40‐inch television screen as compared to a standard videolaryngoscope monitor.Conclusion: The results indicate that our curved prototype and large monitor visualization may provide a cost‐effective minimally invasive alternative for difficult laryngeal exposure. Its special advantages include avoiding the need for a straight line of sight and a simple and cost‐effective construction. The system could be further improved through advances in camera chip technology and smaller instruments. Laryngoscope, 131:E561–E568, 2021
- 25 June 2020
- Published by Wiley in The Laryngoscope
- Vol. 131 (2) , E561-E568
Open AccessAdding Flexible Instrumentation to a Curved Videolaryngoscope: A Novel Tool for Laryngeal Surgery
Objectives: Transoral surgery of the larynx with rigid instruments is not always possible. This may result in insufficient therapy or in an increased need for open surgery. For these patients, alternative surgical systems are needed. Here, we demonstrate a curved prototype for laryngeal surgery equipped with flexible instruments.Study Design: Pre‐clinical user study in an ex vivo porcine laryngeal model.Methods: The prototype was built from established medical devices, namely a hyperangulated videolaryngoscope and modified flexible instruments as well as three‐dimensional printed parts. Feasibility of laryngeal manipulation was evaluated in a user study (n = 19) with a porcine ex vivo laryngeal model. Using three different visualization technologies, the participants performed various fine motor skills tasks and rated the usability of the system on a 5‐point Likert scale.Results: Exposure, accessibility, and manipulation of important laryngeal structures were always possible using the new prototype. The participants needed considerably less time (mean, 96.4 seconds ± 6.4 seconds vs. 111.5 seconds ± 4.5 seconds, P = .18), reported significantly better general impression (mean score 3.0 vs. 3.8, P = .041) and significantly lower user head and neck strain (2.6 vs. 1.7, P = .022) using a 40‐inch television screen as compared to a standard videolaryngoscope monitor.Conclusion: The results indicate that our curved prototype and large monitor visualization may provide a cost‐effective minimally invasive alternative for difficult laryngeal exposure. Its special advantages include avoiding the need for a straight line of sight and a simple and cost‐effective construction. The system could be further improved through advances in camera chip technology and smaller instruments. Laryngoscope, 131:E561–E568, 2021