Khiem Tran Dang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Khiem Tran Dang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Shigeyuki Naka
Department of Surgery, Shiga University of Medical Science, Otsu, Shiga, Japan
7 shared publicationsAtsushi Yamada
Department of Research and Development for Innovative Medical Devices and Systems, Shiga University of Medical Science, Otsu, Shiga, Japan
4 shared publications- Tohru Tani
Department of Advanced Medical Research and Development, Shiga University of Medical Science, Shiga, Japan
4 shared publications - Atsushi Yamada
Medical Innovation Research Center, Shiga University of Medical Science, Otsu, Japan
3 shared publications Soichiro Tani
Shiga University of Medical Science
3 shared publicationsTohru Tani
Department of Research and Development for Innovative Medical Devices and Systems, Shiga University of Medical Science, Otsu, Shiga, Japan
3 shared publications
Latest Publications
- Open Access
- 7 May 2022
- Published by Springer Nature in International Journal of Diabetes in Developing Countries
- Vol. 43 (2) , 199-207
Basal-bolus insulin therapy for the treatment of non-critically ill patients with type 2 diabetes in Vietnam: effectiveness and factors associated with inpatient glycemic control
Purpose: This study assessed the effectiveness of basal-bolus insulin therapy (BBIT) in non-critically ill patients with type 2 diabetes mellitus (DM) and the factors associated with optimal inpatient glycemic control (IGC) with BBIT. Methods: This prospective study included 103 patients who were admitted to the University Medical Center and were treated with BBIT. Clinical characteristics, glucose, and glycated hemoglobin (HbA1c) levels at admission, renal function tests, basal-bolus insulin dosing, and other treatments were recorded. The optimal IGC was defined and classified for the analysis. Results: The mean age of the patients was 67.2 ± 12.0 years. The blood glucose and HbA1c levels at admission were 319.2 ± 184.8 mg/dL and 10.7 ± 2.6%, respectively. Optimal IGC was defined as patients with ≥60% of in-hospital blood glucose values within the target range (3.9–10 mmol/L). Of the 103 patients, 66 patients (64%) achieved optimal IGC and only 5 patients (4.9%) had at least one hypoglycemic episode. The number of patients consuming snacks was higher in the poor than in the optimal IGC group whereas an estimated glomerular filtration rate (eGFR) 2 was predominant in the optimal IGC group. Multivariate analysis revealed that snack consumption and glucocorticoid (GC) use were factors associated with poor IGC, while eGFR 2 was a favorable factor for optimal IGC. Conclusion: BBIT is safe and effective for the treatment of IGC in non-critically ill patients. Moreover, eGFR 2 at admission, snack consumption, and GC therapy were independent factors associated with IGC outcomes.
- 7 May 2022
- Published by Springer Nature in International Journal of Diabetes in Developing Countries
- Vol. 43 (2) , 199-207
Open AccessBasal-bolus insulin therapy for the treatment of non-critically ill patients with type 2 diabetes in Vietnam: effectiveness and factors associated with inpatient glycemic control
Purpose: This study assessed the effectiveness of basal-bolus insulin therapy (BBIT) in non-critically ill patients with type 2 diabetes mellitus (DM) and the factors associated with optimal inpatient glycemic control (IGC) with BBIT. Methods: This prospective study included 103 patients who were admitted to the University Medical Center and were treated with BBIT. Clinical characteristics, glucose, and glycated hemoglobin (HbA1c) levels at admission, renal function tests, basal-bolus insulin dosing, and other treatments were recorded. The optimal IGC was defined and classified for the analysis. Results: The mean age of the patients was 67.2 ± 12.0 years. The blood glucose and HbA1c levels at admission were 319.2 ± 184.8 mg/dL and 10.7 ± 2.6%, respectively. Optimal IGC was defined as patients with ≥60% of in-hospital blood glucose values within the target range (3.9–10 mmol/L). Of the 103 patients, 66 patients (64%) achieved optimal IGC and only 5 patients (4.9%) had at least one hypoglycemic episode. The number of patients consuming snacks was higher in the poor than in the optimal IGC group whereas an estimated glomerular filtration rate (eGFR) 2 was predominant in the optimal IGC group. Multivariate analysis revealed that snack consumption and glucocorticoid (GC) use were factors associated with poor IGC, while eGFR 2 was a favorable factor for optimal IGC. Conclusion: BBIT is safe and effective for the treatment of IGC in non-critically ill patients. Moreover, eGFR 2 at admission, snack consumption, and GC therapy were independent factors associated with IGC outcomes.
- 2 July 2020
- Published by SAGE Publications in Surgical Innovation
- Vol. 27 (6) , 633-643
Vessel-Sealing Capability of Novel Microwave Sealer: Experimental Study in Animal Models
Background. Ultrasonically activated dissectors (UADs) and radiofrequency-based devices have been considered excellent surgical devices because of their reliability and flexibility. Meanwhile, microwave-based devices have demonstrated potential with their unique heating mechanism. This study aims to compare the sealing function of a newly invented forceps-like microwave sealer (MS) with that of currently available UADs. Materials and Methods. MS and 2 examples of UADs (Harmonic Focus+ [HF+] and Sonicision [SNC]) were employed to perform mesenterectomies (in vivo) and sealing sizable vessels (ex vivo). Vessel diameter, seal time, burst pressure (BP), sealing completion, and instrument sticking were recorded. The samples underwent histological investigation for thermal damage evaluation. Results. During mesenterectomies, MS required 3 seconds and 30 W to secure a complete seal. The BP achieved by the MS seal was higher than that of HF+ and SNC on arteries (851 ± 203.7 vs 682.4 ± 287.3, P < .05; vs 833.1 ± 251.2 mmHg, P = .4523, respectively) but was not statistically different on veins (324.9 ± 203.5 vs 460.1 ± 320.3 vs 508.3 ± 350.7 mmHg, P = .215). In all trials, MS caused less sticking but exhibited similar heat-induced alterations to UADs. MS’s thermal spread was not statistically more extended than that of UADs on either arteries or veins. Conclusions. MS was capable of not only sealing tiny vessels but also achieving high-pressure endurance on sizable vessels. Its forceful grasping and synchronous heating process helped create solid stumps with an acceptable thermal spread.
- 2 July 2020
- Published by SAGE Publications in Surgical Innovation
- Vol. 27 (6) , 633-643
Vessel-Sealing Capability of Novel Microwave Sealer: Experimental Study in Animal Models
Background. Ultrasonically activated dissectors (UADs) and radiofrequency-based devices have been considered excellent surgical devices because of their reliability and flexibility. Meanwhile, microwave-based devices have demonstrated potential with their unique heating mechanism. This study aims to compare the sealing function of a newly invented forceps-like microwave sealer (MS) with that of currently available UADs. Materials and Methods. MS and 2 examples of UADs (Harmonic Focus+ [HF+] and Sonicision [SNC]) were employed to perform mesenterectomies (in vivo) and sealing sizable vessels (ex vivo). Vessel diameter, seal time, burst pressure (BP), sealing completion, and instrument sticking were recorded. The samples underwent histological investigation for thermal damage evaluation. Results. During mesenterectomies, MS required 3 seconds and 30 W to secure a complete seal. The BP achieved by the MS seal was higher than that of HF+ and SNC on arteries (851 ± 203.7 vs 682.4 ± 287.3, P < .05; vs 833.1 ± 251.2 mmHg, P = .4523, respectively) but was not statistically different on veins (324.9 ± 203.5 vs 460.1 ± 320.3 vs 508.3 ± 350.7 mmHg, P = .215). In all trials, MS caused less sticking but exhibited similar heat-induced alterations to UADs. MS’s thermal spread was not statistically more extended than that of UADs on either arteries or veins. Conclusions. MS was capable of not only sealing tiny vessels but also achieving high-pressure endurance on sizable vessels. Its forceful grasping and synchronous heating process helped create solid stumps with an acceptable thermal spread.
- 10 June 2019
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 34 (2) , 164-171
Functional Evaluation of a Novel Microwave Surgical Device in a Canine Splenectomy Model
Aim: Partial splenectomy remains a difficult procedure even with the assistance of a sealing system. Recently, a scissor-like microwave energy device (Acrosurg) that provides seamless coagulation and manual cutting has been applied in surgery. The objective of this study is to evaluate the surgical capabilities of Acrosurg in partial splenectomy. Materials and Methods: Acrosurg and Harmonic Focus (HF) were employed for partial splenectomy in dogs without prior ligation of vessels. Cutting time, cutting area, and bleeding were recorded. Lateral thermal injury (LTI), possible complications was observed immediately and after 4 weeks. Results: The manual cutting mechanism of Acrosurg required a longer cutting time compared with the automatic cutting mode of HF (301.5 [243.2–527] vs. 114.5 [106.0–135.0] sec, p < 0.01). There was no statistical difference in cutting area or bleeding cases. Acrosurg achieved complete hemostasis in all cases, whereas the HF group failed to stop bleeding in two of the eight cases. The Acrosurg group exhibited a similar LTI compared with the HF group (3.0 [2.4–3.4] vs. 2.7 [2.3–2.9] mm, p = 0.151), but the LTI of the Acrosurg group tended to shrink more after 4 weeks (1.2 [1.0–1.3] vs. 1.7 [1.3–1.9] mm, p < 0.05). Conclusions: A microwave energy device enabled a partial splenectomy without vessel ligation. The combination of manual cutting and sealing capability helps not only provide an appropriate seal time by adjusting cutting timing adaptively but also potentially stop bleeding by using a microwave heating process unlike other energy devices.
- 10 June 2019
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 34 (2) , 164-171
Functional Evaluation of a Novel Microwave Surgical Device in a Canine Splenectomy Model
Aim: Partial splenectomy remains a difficult procedure even with the assistance of a sealing system. Recently, a scissor-like microwave energy device (Acrosurg) that provides seamless coagulation and manual cutting has been applied in surgery. The objective of this study is to evaluate the surgical capabilities of Acrosurg in partial splenectomy. Materials and Methods: Acrosurg and Harmonic Focus (HF) were employed for partial splenectomy in dogs without prior ligation of vessels. Cutting time, cutting area, and bleeding were recorded. Lateral thermal injury (LTI), possible complications was observed immediately and after 4 weeks. Results: The manual cutting mechanism of Acrosurg required a longer cutting time compared with the automatic cutting mode of HF (301.5 [243.2–527] vs. 114.5 [106.0–135.0] sec, p < 0.01). There was no statistical difference in cutting area or bleeding cases. Acrosurg achieved complete hemostasis in all cases, whereas the HF group failed to stop bleeding in two of the eight cases. The Acrosurg group exhibited a similar LTI compared with the HF group (3.0 [2.4–3.4] vs. 2.7 [2.3–2.9] mm, p = 0.151), but the LTI of the Acrosurg group tended to shrink more after 4 weeks (1.2 [1.0–1.3] vs. 1.7 [1.3–1.9] mm, p < 0.05). Conclusions: A microwave energy device enabled a partial splenectomy without vessel ligation. The combination of manual cutting and sealing capability helps not only provide an appropriate seal time by adjusting cutting timing adaptively but also potentially stop bleeding by using a microwave heating process unlike other energy devices.
- 6 June 2019
- Published by Springer Nature
- p. 15-19
Design and Implementation of Loop Shaped Steering Mechanisms for Flexible Needles
- 6 June 2019
- Published by Springer Nature
- p. 15-19
Design and Implementation of Loop Shaped Steering Mechanisms for Flexible Needles
- 10 May 2018
- Published by Springer Nature in Surgery Today
- Vol. 48 (9) , 856-864
The invention of microwave surgical scissors for seamless coagulation and cutting
Purpose We developed a microwave energy-based scissors device (MWCX) that is capable of performing cutting and coagulation using 2.45 GHz microwave energy. This paper aims to present the concept of the device and assess the basic functions including the hemostasis, cutting, and sealing abilities. Methods Seven beagle dogs were used in our experiments. In six dogs, we measured the coagulation time (CT), lateral thermal injury (LTI), bursting pressure (BP). The dogs were then subjected to re-laparotomy 1 week later to allow us to investigate the results. In one dog, the same factors and the quantities of smoke and mist emitted were compared to those observed when using a Harmonic Focus (HF) device. Results At 60 W, the MWCX could cut and seal small (5 s, diameter 1–2 mm) and medium-sized (10 s, 3–4 mm) vessels with complete hemostasis. The liver (length 2 cm) was cut for 30 s. Harvested vessels were sealed for 10 s (artery, 17 times; vein, six times). The mean BP was 887. 8 ± 41.5 mmHg in the medium arteries and 457.2 ± 118.0 mmHg in veins, with a mean diameter of 4.5 ± 1.3 mm. In a comparative study, the MWCX showed similar results to the HF with regard to the CT, BP and LTI, and emitted less smoke and mist. Conclusion The MWCX showed similar levels of functionality and safety to HF, as well as the advantages offered by the use of microwave energy. Microwave devices might be used in the majority of applications for which traditional energy devices are used.
- 10 May 2018
- Published by Springer Nature in Surgery Today
- Vol. 48 (9) , 856-864
The invention of microwave surgical scissors for seamless coagulation and cutting
Purpose We developed a microwave energy-based scissors device (MWCX) that is capable of performing cutting and coagulation using 2.45 GHz microwave energy. This paper aims to present the concept of the device and assess the basic functions including the hemostasis, cutting, and sealing abilities. Methods Seven beagle dogs were used in our experiments. In six dogs, we measured the coagulation time (CT), lateral thermal injury (LTI), bursting pressure (BP). The dogs were then subjected to re-laparotomy 1 week later to allow us to investigate the results. In one dog, the same factors and the quantities of smoke and mist emitted were compared to those observed when using a Harmonic Focus (HF) device. Results At 60 W, the MWCX could cut and seal small (5 s, diameter 1–2 mm) and medium-sized (10 s, 3–4 mm) vessels with complete hemostasis. The liver (length 2 cm) was cut for 30 s. Harvested vessels were sealed for 10 s (artery, 17 times; vein, six times). The mean BP was 887. 8 ± 41.5 mmHg in the medium arteries and 457.2 ± 118.0 mmHg in veins, with a mean diameter of 4.5 ± 1.3 mm. In a comparative study, the MWCX showed similar results to the HF with regard to the CT, BP and LTI, and emitted less smoke and mist. Conclusion The MWCX showed similar levels of functionality and safety to HF, as well as the advantages offered by the use of microwave energy. Microwave devices might be used in the majority of applications for which traditional energy devices are used.