Toshio Yamaguchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Toshio Yamaguchi has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Hirokazu Iwamuro
Department of Neurosurgery, Juntendo University, Bunkyo City, Tokyo, Japan
2 shared publicationsHiroki Hori
Department of Radiology
2 shared publicationsKazuo Watanabe
Southern Tohoku Research Institute for Neuroscience, Koriyama, Japan
2 shared publicationsKeiichi Abe
Department of Neurosurgery, Tokyo Women's Medical University, Shinjuku, Tokyo, Japan
2 shared publicationsKen Iijima
International Academia for Focused Ultrasound Therapy, Kawasaki, Japan
2 shared publicationsMasahito Takasaki
Department of Anesthesiology, Shin-Yurigaoka General Hospital, Kawasaki, Japan
2 shared publications
Latest Publications
- Open Access
- 29 November 2023
- Published by MDPI AG in Neurology International
- Vol. 15 (4) , 1411-1422
Video Motion Analysis as a Quantitative Evaluation Tool for Essential Tremor during Magnetic Resonance-Guided Focused Ultrasound Thalamotomy
The Clinical Rating Scale for Tremor (CRST) is commonly used to evaluate essential tremor (ET) during focused ultrasound (FUS) thalamotomy. However, it faces challenges such as the ceiling effect and test–retest variability. This study explored the utility of videographic motion analysis as an evaluation index for ET. Forty-three patients with ET performed postural tremor and line-drawing tasks recorded on video, and the data were analyzed using motion analysis software. The test–retest and inter-rater reliability, correlations with the CRST and tremor scores, and pre/post-FUS treatment comparisons were analyzed. The video motion analysis showed excellent test–retest and inter-rater reliability. In the postural tremor tasks, video parameter amplitude significantly correlated with the CRST and tremor scores. Similarly, for the line-drawing task, video parameter amplitude showed significant correlations with CRST and tremor scores, effectively addressing the ceiling effect. Regarding post-FUS treatment improvements, changes in the CRST and tremor scores were significantly associated with changes in video parameter amplitude. In conclusion, quantitative analysis of the video motion of ET enables precise evaluation of kinematic characteristics and effectively resolves the ceiling effect and test–retest variability. The video motion analysis score accurately reflected the tremor severity and treatment effects, demonstrating its high clinical utility.
- 29 November 2023
- Published by MDPI AG in Neurology International
- Vol. 15 (4) , 1411-1422
Open AccessVideo Motion Analysis as a Quantitative Evaluation Tool for Essential Tremor during Magnetic Resonance-Guided Focused Ultrasound Thalamotomy
The Clinical Rating Scale for Tremor (CRST) is commonly used to evaluate essential tremor (ET) during focused ultrasound (FUS) thalamotomy. However, it faces challenges such as the ceiling effect and test–retest variability. This study explored the utility of videographic motion analysis as an evaluation index for ET. Forty-three patients with ET performed postural tremor and line-drawing tasks recorded on video, and the data were analyzed using motion analysis software. The test–retest and inter-rater reliability, correlations with the CRST and tremor scores, and pre/post-FUS treatment comparisons were analyzed. The video motion analysis showed excellent test–retest and inter-rater reliability. In the postural tremor tasks, video parameter amplitude significantly correlated with the CRST and tremor scores. Similarly, for the line-drawing task, video parameter amplitude showed significant correlations with CRST and tremor scores, effectively addressing the ceiling effect. Regarding post-FUS treatment improvements, changes in the CRST and tremor scores were significantly associated with changes in video parameter amplitude. In conclusion, quantitative analysis of the video motion of ET enables precise evaluation of kinematic characteristics and effectively resolves the ceiling effect and test–retest variability. The video motion analysis score accurately reflected the tremor severity and treatment effects, demonstrating its high clinical utility.
- 14 March 2023
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 165 (5) , 1195-1200
Cavitation with low-energy sonication during focused ultrasound thalamotomy for a patient with tremor-dominant Parkinson’s disease: a potential risk
We report a patient with tremor-dominant Parkinson’s disease who had a mild cavitation bioeffect during magnetic resonance–guided focused ultrasound thalamotomy. During the aligning phase with low-energy sonication, cavitation caused mild dysarthria and paresthesia, prompting treatment cessation. At the same time, tremor and rigidity improved. MRI revealed extensive high-intensity lesions in the thalamus 1 day after the procedure followed by steroid infusion, which resulted in resolution of adverse events. Tremor and rigidity improved 1.5 years after the procedure. Although cavitation can relieve tremors and rigidity, it should be carefully monitored due to potential permanent adverse events by unpredictable and unknown behaviors.
- 14 March 2023
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 165 (5) , 1195-1200
Cavitation with low-energy sonication during focused ultrasound thalamotomy for a patient with tremor-dominant Parkinson’s disease: a potential risk
We report a patient with tremor-dominant Parkinson’s disease who had a mild cavitation bioeffect during magnetic resonance–guided focused ultrasound thalamotomy. During the aligning phase with low-energy sonication, cavitation caused mild dysarthria and paresthesia, prompting treatment cessation. At the same time, tremor and rigidity improved. MRI revealed extensive high-intensity lesions in the thalamus 1 day after the procedure followed by steroid infusion, which resulted in resolution of adverse events. Tremor and rigidity improved 1.5 years after the procedure. Although cavitation can relieve tremors and rigidity, it should be carefully monitored due to potential permanent adverse events by unpredictable and unknown behaviors.
- Open Access
- 28 April 2022
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 37 (8) , 1561-1570
Exacerbation of non‐steroidal anti‐inflammatory drug‐induced enteropathy in C‐C chemokine receptor type 7‐deficient mice
Background and Aim: Non‐steroidal anti‐inflammatory drugs (NSAIDs) induce intestinal enteropathy and the pathophysiology is related to immune‐mediated mechanisms. We aimed to investigate the role of C‐C chemokine receptor type 7 (CCR7) which regulates immune cell migration in NSAID‐induced enteropathy.Methods: Injury of the small intestine was evaluated 24 h after the subcutaneous injection of indomethacin in CCR7‐deficient (Ccr7−/−) and wild‐type (WT) mice. The cellular profile and cytokine production in intestinal cells were analyzed. Indomethacin‐induced enteropathy was evaluated in mice adoptively transferred with CD103+ dendritic cells (DCs) from Ccr7−/− or WT mice.Results: Indomethacin induced more severe intestinal injury in Ccr7−/− mice than in WT mice. The major inflammatory cytokines were not increased and the proportion of regulatory T cells following indomethacin injection was not decreased in Ccr7−/− mice compared with WT mice. The expression of interleukin (IL)‐22 binding protein (IL‐22BP), which inhibits IL‐22 activity, was significantly higher in CD103+ DCs from Ccr7−/− mice than those from WT mice. Mice adoptively transferred with CD103+ DCs isolated from Ccr7−/− mice exhibited more severe intestinal injury following indomethacin injection compared with those adoptively transferred with CD103+ DCs of WT mice. Ccr7−/− mice injected with indomethacin showed a significant reduction in regenerating islet‐derived 1 (Reg1) mRNA expression, which is regulated by IL‐22, in intestinal epithelial cells.Conclusions: C‐C chemokine receptor type 7 deficiency exacerbated NSAID‐induced enteropathy in association with an altered phenotype of CD103+ DCs that produces IL‐22BP. CCR7 contributes to protect the small intestine from NSAID‐induced mucosal injury.
- 28 April 2022
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 37 (8) , 1561-1570
Open AccessExacerbation of non‐steroidal anti‐inflammatory drug‐induced enteropathy in C‐C chemokine receptor type 7‐deficient mice
Background and Aim: Non‐steroidal anti‐inflammatory drugs (NSAIDs) induce intestinal enteropathy and the pathophysiology is related to immune‐mediated mechanisms. We aimed to investigate the role of C‐C chemokine receptor type 7 (CCR7) which regulates immune cell migration in NSAID‐induced enteropathy.Methods: Injury of the small intestine was evaluated 24 h after the subcutaneous injection of indomethacin in CCR7‐deficient (Ccr7−/−) and wild‐type (WT) mice. The cellular profile and cytokine production in intestinal cells were analyzed. Indomethacin‐induced enteropathy was evaluated in mice adoptively transferred with CD103+ dendritic cells (DCs) from Ccr7−/− or WT mice.Results: Indomethacin induced more severe intestinal injury in Ccr7−/− mice than in WT mice. The major inflammatory cytokines were not increased and the proportion of regulatory T cells following indomethacin injection was not decreased in Ccr7−/− mice compared with WT mice. The expression of interleukin (IL)‐22 binding protein (IL‐22BP), which inhibits IL‐22 activity, was significantly higher in CD103+ DCs from Ccr7−/− mice than those from WT mice. Mice adoptively transferred with CD103+ DCs isolated from Ccr7−/− mice exhibited more severe intestinal injury following indomethacin injection compared with those adoptively transferred with CD103+ DCs of WT mice. Ccr7−/− mice injected with indomethacin showed a significant reduction in regenerating islet‐derived 1 (Reg1) mRNA expression, which is regulated by IL‐22, in intestinal epithelial cells.Conclusions: C‐C chemokine receptor type 7 deficiency exacerbated NSAID‐induced enteropathy in association with an altered phenotype of CD103+ DCs that produces IL‐22BP. CCR7 contributes to protect the small intestine from NSAID‐induced mucosal injury.
- 1 January 2022
- Vol. 119 (5) , 459-465
[A case of eosinophilic gastroenteritis caused after the use of Seprafilm®].
Eosinophilic gastroenteritis is a fairly uncommon condition. It has been suggested that allergic reactions may have played a role in the development of this illness. The case of a 66-year-old woman who had a total hysterectomy due to a right ovarian tumor is described here. At this operation, a sodium hyaluronate carboxymethylcellulose bioresorbable membrane (Seprafilm®) was used. She was admitted to our hospital 47 days after the operation with abdominal pain. Laboratory data indicated elevated WBC (29450/μl) and eosinophilia (69.2%), and CT scan showed thickening of intestinal wall and ascites around there. Ascites cytology showed a significant increase of eosinophils (94.0%). She began taking oral steroids after being diagnosed with eosinophilic gastroenteritis, and her symptoms improved quickly. Despite the fact that Seprafilm® was thought to be a reliable and safe tool, it was suggested that a foreign body reaction to Seprafilm® could lead to eosinophilic gastroenteritis.
- 1 January 2022
- Vol. 119 (5) , 459-465
[A case of eosinophilic gastroenteritis caused after the use of Seprafilm®].
Eosinophilic gastroenteritis is a fairly uncommon condition. It has been suggested that allergic reactions may have played a role in the development of this illness. The case of a 66-year-old woman who had a total hysterectomy due to a right ovarian tumor is described here. At this operation, a sodium hyaluronate carboxymethylcellulose bioresorbable membrane (Seprafilm®) was used. She was admitted to our hospital 47 days after the operation with abdominal pain. Laboratory data indicated elevated WBC (29450/μl) and eosinophilia (69.2%), and CT scan showed thickening of intestinal wall and ascites around there. Ascites cytology showed a significant increase of eosinophils (94.0%). She began taking oral steroids after being diagnosed with eosinophilic gastroenteritis, and her symptoms improved quickly. Despite the fact that Seprafilm® was thought to be a reliable and safe tool, it was suggested that a foreign body reaction to Seprafilm® could lead to eosinophilic gastroenteritis.
- 1 November 2021
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 135 (5) , 1436-1444
Correction of the skull density ratio for transcranial MRI-guided focused ultrasound thalamotomy: clinical significance of predicting therapeutic temperature
OBJECTIVE: In transcranial magnetic resonance imaging–guided focused ultrasound (TcMRgFUS), a high skull density ratio (SDR) is advantageous to achieve a sufficiently high temperature at the target. However, it is not easy to estimate the temperature rise because the SDR shows different values depending on the reconstruction filter used. The resolution characteristic of a computed tomography (CT) image depends on a modulation transfer function (MTF) defined by the reconstruction filter. Differences in MTF induce unstable SDRs. The purpose of this study was both to standardize SDR by developing a method to correct the MTF and to enable effective patient screening prior to TcMRgFUS treatment and more accurate predictions of focal temperature. METHODS: CT images of a skull phantom and five subjects were obtained using eight different reconstruction filters. A frequency filter (FF) was calculated using the MTF of each reconstruction filter, and the validity of SDR standardization was evaluated by comparing the variation in SDR before and after FF correction. Subsequently, FF processing was similarly performed using the CT images of 18 patients who had undergone TcMRgFUS, and statistical analyses were performed comparing the relationship between the SDRs before and after correction and the maximum temperature in the target during TcMRgFUS treatment. RESULTS: The FF was calculated for each reconstruction filter based on one manufacturer's BONE filter. In the CT images of the skull phantom, the SDR before FF correction with five of the other seven reconstruction filters was significantly smaller than that with the BONE filter (p < 0.01). After FF correction, however, a significant difference was recognized under only one condition. In the CT images of the five subjects, variation of the SDR due to imaging conditions was significantly improved after the FF correction. In 18 cases treated with TcMRgFUS, there was no correlation between SDR before FF correction and maximum temperature (r s = 0.31, p > 0.05); however, a strong positive correlation was observed after FF correction (r s = 0.71, p < 0.01). CONCLUSIONS: After FF correction, the difference in SDR due to the reconstruction filter used is smaller, and the correlation with temperature is stronger. Therefore, the SDR can be standardized by applying the FF, and the maximum temperature during treatment may be predicted more accurately.
- 1 November 2021
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 135 (5) , 1436-1444
Correction of the skull density ratio for transcranial MRI-guided focused ultrasound thalamotomy: clinical significance of predicting therapeutic temperature
OBJECTIVE: In transcranial magnetic resonance imaging–guided focused ultrasound (TcMRgFUS), a high skull density ratio (SDR) is advantageous to achieve a sufficiently high temperature at the target. However, it is not easy to estimate the temperature rise because the SDR shows different values depending on the reconstruction filter used. The resolution characteristic of a computed tomography (CT) image depends on a modulation transfer function (MTF) defined by the reconstruction filter. Differences in MTF induce unstable SDRs. The purpose of this study was both to standardize SDR by developing a method to correct the MTF and to enable effective patient screening prior to TcMRgFUS treatment and more accurate predictions of focal temperature. METHODS: CT images of a skull phantom and five subjects were obtained using eight different reconstruction filters. A frequency filter (FF) was calculated using the MTF of each reconstruction filter, and the validity of SDR standardization was evaluated by comparing the variation in SDR before and after FF correction. Subsequently, FF processing was similarly performed using the CT images of 18 patients who had undergone TcMRgFUS, and statistical analyses were performed comparing the relationship between the SDRs before and after correction and the maximum temperature in the target during TcMRgFUS treatment. RESULTS: The FF was calculated for each reconstruction filter based on one manufacturer's BONE filter. In the CT images of the skull phantom, the SDR before FF correction with five of the other seven reconstruction filters was significantly smaller than that with the BONE filter (p < 0.01). After FF correction, however, a significant difference was recognized under only one condition. In the CT images of the five subjects, variation of the SDR due to imaging conditions was significantly improved after the FF correction. In 18 cases treated with TcMRgFUS, there was no correlation between SDR before FF correction and maximum temperature (r s = 0.31, p > 0.05); however, a strong positive correlation was observed after FF correction (r s = 0.71, p < 0.01). CONCLUSIONS: After FF correction, the difference in SDR due to the reconstruction filter used is smaller, and the correlation with temperature is stronger. Therefore, the SDR can be standardized by applying the FF, and the maximum temperature during treatment may be predicted more accurately.
- 2 July 2020
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 162 (10) , 2513-2517
Magnetic resonance–guided focused ultrasound ablation of hypothalamic hamartoma as a disconnection surgery: a case report
We report the case of a patient with hypothalamic hamartoma (HH) who was successfully treated with magnetic resonance–guided focused ultrasound (MRgFUS) for ablation as a disconnection surgery. A 26-year-old man with gelastic epilepsy had been diagnosed with HH at 3 years of age, and antiepileptic drugs were administered due to worsening episodes. Magnetic resonance imaging showed a sessile parahypothalamic hamartoma and MRgFUS ablation was performed, creating an oval-shaped lesion at the boundary area of the HH. Dramatic improvements in seizure symptoms were noted, and he was seizure-free on decreased antiepileptic drugs without any adverse events over the 1-year follow-up period.
- 2 July 2020
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 162 (10) , 2513-2517
Magnetic resonance–guided focused ultrasound ablation of hypothalamic hamartoma as a disconnection surgery: a case report
We report the case of a patient with hypothalamic hamartoma (HH) who was successfully treated with magnetic resonance–guided focused ultrasound (MRgFUS) for ablation as a disconnection surgery. A 26-year-old man with gelastic epilepsy had been diagnosed with HH at 3 years of age, and antiepileptic drugs were administered due to worsening episodes. Magnetic resonance imaging showed a sessile parahypothalamic hamartoma and MRgFUS ablation was performed, creating an oval-shaped lesion at the boundary area of the HH. Dramatic improvements in seizure symptoms were noted, and he was seizure-free on decreased antiepileptic drugs without any adverse events over the 1-year follow-up period.
- 1 January 2019
- Published by Japan Society of Civil Engineers in Journal of Japan Society of Civil Engineers, Ser. G (Environmental Research)
- Vol. 75 (7) , III_145-III_151
INVESTIGATION OF ANAEROBIC MICROBES POTENCIALLY CONTRIBUTING TO OCTADECANE DEGRADATION IN METHANE FERMENTATION PROCESS
オクタデカンの嫌気的分解に直接的に関与する微生物群を明らかにするため, 新津川底泥を植種源とした2基の完全混合型リアクターによるメタン発酵微生物群の集積培養を行い, 原核生物の群集構造の比較解析を行った. オクタデカンを供給する完全混合型リアクターおよび供給しないリアクターが定常状態に達したday 92におけるリアクター内汚泥の16S rRNA遺伝子アンプリコン解析を行った結果, オクタデカンを供給するリアクターにおいてRikenellaceae(Blvii28)科細菌, Bacteroides属細菌, Kosmotoga属細菌がオクタデカンを供給しないリアクターと比較して高い頻度で検出された. これによりこれらの細菌種がリアクター内でオクタデカンの嫌気的分解に重要な役割を果たしている可能性が高いものと考えられた.
- 1 January 2019
- Published by Japan Society of Civil Engineers in Journal of Japan Society of Civil Engineers, Ser. G (Environmental Research)
- Vol. 75 (7) , III_145-III_151
INVESTIGATION OF ANAEROBIC MICROBES POTENCIALLY CONTRIBUTING TO OCTADECANE DEGRADATION IN METHANE FERMENTATION PROCESS
オクタデカンの嫌気的分解に直接的に関与する微生物群を明らかにするため, 新津川底泥を植種源とした2基の完全混合型リアクターによるメタン発酵微生物群の集積培養を行い, 原核生物の群集構造の比較解析を行った. オクタデカンを供給する完全混合型リアクターおよび供給しないリアクターが定常状態に達したday 92におけるリアクター内汚泥の16S rRNA遺伝子アンプリコン解析を行った結果, オクタデカンを供給するリアクターにおいてRikenellaceae(Blvii28)科細菌, Bacteroides属細菌, Kosmotoga属細菌がオクタデカンを供給しないリアクターと比較して高い頻度で検出された. これによりこれらの細菌種がリアクター内でオクタデカンの嫌気的分解に重要な役割を果たしている可能性が高いものと考えられた.
- 1 November 1991
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 30 (11R) , 2965-2969
Representative Figure Method for Proximity Effect Correction [II]
The representative figure method, which was proposed to greatly reduce the proximity effect correction time, is studied in detail in this paper. The method is shown to have a high correction accuracy (the error is 0.25% for a 50 kV acceleration voltage and a 2 µm small area) and a high speed correction time (which includes the time for preparing representative rectangles; 1/10 compared with the conventional method). The basic idea of the present method is found to be applicable to data compaction. The compaction ratio by this method is (1/2)-(1/100) of that by the conventional method. The representative figure method has a wide range of applications and has many advantages.
- 1 November 1991
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 30 (11R) , 2965-2969
Representative Figure Method for Proximity Effect Correction [II]
The representative figure method, which was proposed to greatly reduce the proximity effect correction time, is studied in detail in this paper. The method is shown to have a high correction accuracy (the error is 0.25% for a 50 kV acceleration voltage and a 2 µm small area) and a high speed correction time (which includes the time for preparing representative rectangles; 1/10 compared with the conventional method). The basic idea of the present method is found to be applicable to data compaction. The compaction ratio by this method is (1/2)-(1/100) of that by the conventional method. The representative figure method has a wide range of applications and has many advantages.