Joshua D. Hubbard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joshua D. Hubbard has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Ryan Daniel Sochol
Department of Mechanical Engineering, University of Maryland, College Park, USA
2 shared publications - Abdullah T. Alsharhan
Department of Mechanical Engineering, University of Maryland, College Park, MD 20742, USA
1 shared publication - Andrew C. Lamont
Center for Biotechnology (4DBio3), Department of Radiology and Radiological Sciences, Uniformed Services University, Bethesda, MD 20814, USA
1 shared publication - Andrew V. Latchman
Department of Mechanical Engineering, University of Maryland, College Park, MD 20742 USA, and also with the Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742 USA
1 shared publication - Daniel J. Rosenberg
Linac Coherent Light Source, SLAC National Accelerator Laboratory, Menlo Park, USA
1 shared publication - Elizabeth Childs
Stanford University, Stanford, USA
1 shared publication
Latest Publications
- Open Access
Mapping the Morphology of DNA on Carbon Nanotube-Based Sensors in Solution using X-ray Scattering Interferometry
Single-walled carbon nanotubes (SWCNTs) with adsorbed single-stranded DNA (ssDNA) are applied as sensors to investigate biological systems, with applications ranging from clinical diagnostics to agricultural biotechnology. Unique ssDNA sequences render SWCNTs selectively responsive to target analytes. However, it remains unclear how the ssDNA conformation on the SWCNT surface contributes to their ultimate functionality, as observations have been constrained to computational models or experiments under dehydrated states that differ substantially from the aqueous biological environments in which the nanosensors are applied. Herein, we demonstrate a direct mode of measuring in-solution ssDNA geometries on SWCNTs via X-ray scattering interferometry (XSI), which leverages the interference pattern produced by AuNP tags conjugated to ssDNA on the SWCNT surface. We employ XSI to quantify distinct surface-adsorbed morphologies for two ssDNA oligomer lengths, conformational changes as a function of ionic strength, and the mechanism of dopamine sensing for a previously established ssDNA-SWCNT nanosensor, with corresponding ab initio modeling for visualization. We show that the shorter oligomer, (GT) 6 , adopts a highly ordered structure of stacked rings along the SWCNT axis, compared to the longer, less periodic (GT) 15 wrapping. The presence of dopamine elicits a simultaneous axial elongation and radial constriction of the ssDNA closer to the SWCNT surface. Application of XSI to probe solution-phase morphologies of nanoparticle-based tools will yield insights into sensing mechanisms and inform future design strategies for polymer-functionalized SWCNT technologies.
Open AccessMapping the Morphology of DNA on Carbon Nanotube-Based Sensors in Solution using X-ray Scattering Interferometry
Single-walled carbon nanotubes (SWCNTs) with adsorbed single-stranded DNA (ssDNA) are applied as sensors to investigate biological systems, with applications ranging from clinical diagnostics to agricultural biotechnology. Unique ssDNA sequences render SWCNTs selectively responsive to target analytes. However, it remains unclear how the ssDNA conformation on the SWCNT surface contributes to their ultimate functionality, as observations have been constrained to computational models or experiments under dehydrated states that differ substantially from the aqueous biological environments in which the nanosensors are applied. Herein, we demonstrate a direct mode of measuring in-solution ssDNA geometries on SWCNTs via X-ray scattering interferometry (XSI), which leverages the interference pattern produced by AuNP tags conjugated to ssDNA on the SWCNT surface. We employ XSI to quantify distinct surface-adsorbed morphologies for two ssDNA oligomer lengths, conformational changes as a function of ionic strength, and the mechanism of dopamine sensing for a previously established ssDNA-SWCNT nanosensor, with corresponding ab initio modeling for visualization. We show that the shorter oligomer, (GT) 6 , adopts a highly ordered structure of stacked rings along the SWCNT axis, compared to the longer, less periodic (GT) 15 wrapping. The presence of dopamine elicits a simultaneous axial elongation and radial constriction of the ssDNA closer to the SWCNT surface. Application of XSI to probe solution-phase morphologies of nanoparticle-based tools will yield insights into sensing mechanisms and inform future design strategies for polymer-functionalized SWCNT technologies.
- Top Cited PapersOpen Access
- 16 July 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (29) , eabe5257
Fully 3D-printed soft robots with integrated fluidic circuitry
We 3D-print unified soft robots comprising fully integrated fluidic circuitry capable of sophisticated operations.
- 16 July 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (29) , eabe5257
Top Cited PapersOpen AccessFully 3D-printed soft robots with integrated fluidic circuitry
We 3D-print unified soft robots comprising fully integrated fluidic circuitry capable of sophisticated operations.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1094-1096
Additive Assembly for PolyJet-Based Multi-Material 3D Printed Microfluidics
PolyJet-based additive manufacturing (or ``three-dimensional (3D) printing'') techniques allow for micro-to-mesoscale fluidic systems to be produced with multiple, fully integrated materials and unparalleled geometric versatility (due to the use of sacrificial support materials). Although the PolyJet 3D printing process is autonomous and fast, the post-processing methods required to remove the sacrificial materials can be exceedingly time-intensive for systems with enclosed channels, often resulting in device degradation. To bypass such issues, here we present a novel ``additive assembly'' strategy for realizing PolyJet-printed multi-material microfluidic components. In this work, we print a microfluidic capacitor as two separate halves to enable facile support material removal, and then fasten the parts together via designed integration features. Fabrication results revealed a significant reduction in post-processing time by approximately 98% compared to enclosed control designs. Experimental results for burst-pressure testing - a measure of component integrity - revealed that the additively assembled microfluidic capacitors retained a maximum internal pressure in excess of 189 kPa before failure. The results suggest that the presented additive assembly strategy holds promise for greatly extending the utility of PolyJet 3D printing for micro- and millifluidic applications. [2020-0111]
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1094-1096
Additive Assembly for PolyJet-Based Multi-Material 3D Printed Microfluidics
PolyJet-based additive manufacturing (or ``three-dimensional (3D) printing'') techniques allow for micro-to-mesoscale fluidic systems to be produced with multiple, fully integrated materials and unparalleled geometric versatility (due to the use of sacrificial support materials). Although the PolyJet 3D printing process is autonomous and fast, the post-processing methods required to remove the sacrificial materials can be exceedingly time-intensive for systems with enclosed channels, often resulting in device degradation. To bypass such issues, here we present a novel ``additive assembly'' strategy for realizing PolyJet-printed multi-material microfluidic components. In this work, we print a microfluidic capacitor as two separate halves to enable facile support material removal, and then fasten the parts together via designed integration features. Fabrication results revealed a significant reduction in post-processing time by approximately 98% compared to enclosed control designs. Experimental results for burst-pressure testing - a measure of component integrity - revealed that the additively assembled microfluidic capacitors retained a maximum internal pressure in excess of 189 kPa before failure. The results suggest that the presented additive assembly strategy holds promise for greatly extending the utility of PolyJet 3D printing for micro- and millifluidic applications. [2020-0111]