Hussein Mehidine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hussein Mehidine has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Darine Abi Haidar
Université Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France
2 shared publications - Bertrand Devaux
Department of Neurosurgery, Lariboisiere Hospital, Paris, France andParis-City University, Paris, France
1 shared publication - Emile Kaadou Mouawad
Université Paris-Saclay, CNRS/IN2P3, IJCLab, 91405 Orsay, France
1 shared publication - Francoise Bouvet
Université Paris-Saclay, CNRS/IN2P3, IJCLab, 91405 Orsay, France
1 shared publication - Huikai Xie
Beijing Institute of Technology
1 shared publication - Jean-Francois Lendresse
Université Paris-Saclay, CNRS/IN2P3, IJCLab, 91405 Orsay, France
1 shared publication
Latest Publications
- Open Access
Quantitative Endogenous Fluorescence Analysis Discriminates Glioblastoma Tumor through Visible and NIR Excitation
Nowadays, the ability to diagnose brain tumors intraoperatively and delineate their margins, as accurately as possible, is of primordial importance during surgery. However, the exact tumor boundaries and targets are difficult to find due to the similar visual appearances especially at the margins, leading in many cases to poor surgical outcomes and a high risk of recurrences. To solve this dogma, our group tried to determine different tissue optical signatures such as optical parameters and endogenous fluorescence. For that, we conducted a comparative study to differentiate between healthy and tumorous tissues under one- and two-photon excitations on optical properties to explore several optical parameters. In addition, the study of endogenous fluorescence can successfully help with the discrimination between tissue types using one- and two-photon excitations. This works suggests that the multimodal analysis of optical signatures of tissues could be a reliable technique that can be used to differentiate between healthy and tumorous tissues. This can help in the future with the implementation of such techniques in vivo during surgery to help the surgeon with the decision that needs to be taken as for tissue resection.
Open AccessQuantitative Endogenous Fluorescence Analysis Discriminates Glioblastoma Tumor through Visible and NIR Excitation
Nowadays, the ability to diagnose brain tumors intraoperatively and delineate their margins, as accurately as possible, is of primordial importance during surgery. However, the exact tumor boundaries and targets are difficult to find due to the similar visual appearances especially at the margins, leading in many cases to poor surgical outcomes and a high risk of recurrences. To solve this dogma, our group tried to determine different tissue optical signatures such as optical parameters and endogenous fluorescence. For that, we conducted a comparative study to differentiate between healthy and tumorous tissues under one- and two-photon excitations on optical properties to explore several optical parameters. In addition, the study of endogenous fluorescence can successfully help with the discrimination between tissue types using one- and two-photon excitations. This works suggests that the multimodal analysis of optical signatures of tissues could be a reliable technique that can be used to differentiate between healthy and tumorous tissues. This can help in the future with the implementation of such techniques in vivo during surgery to help the surgeon with the decision that needs to be taken as for tissue resection.
- Open Access
- 21 July 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (7) , 704
A Customized Two Photon Fluorescence Imaging Probe Based on 2D scanning MEMS Mirror Including Electrothermal Two-Level-Ladder Dual S-Shaped Actuators
We report the design and characterization of a two-photon fluorescence imaging miniature probe. This customized two-axis scanning probe is dedicated for intraoperative two-photon fluorescence imaging endomicroscopic use and is based on a micro-electro-mechanical system (MEMS) mirror with a high reflectivity plate and two-level-ladder double S-shaped electrothermal bimorph actuators. The fully assembled probe has a total outer diameter of 4 mm including all elements. With a two-lens configuration and a small aperture MEMS mirror, this probe can generate a large optical scan angle of 24° with 4 V drive voltage and can achieve a 450 µm FOV with a 2-fps frame rate. A uniform Pixel Dwell Time and a stable scanning speed along a raster pattern were demonstrated while a 57-fs pulse duration of the excitation beam was measured at the exit of the probe head. This miniature imaging probe will be coupled to a two-photon fluorescence endomicroscope oriented towards clinical use.
- 21 July 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (7) , 704
Open AccessA Customized Two Photon Fluorescence Imaging Probe Based on 2D scanning MEMS Mirror Including Electrothermal Two-Level-Ladder Dual S-Shaped Actuators
We report the design and characterization of a two-photon fluorescence imaging miniature probe. This customized two-axis scanning probe is dedicated for intraoperative two-photon fluorescence imaging endomicroscopic use and is based on a micro-electro-mechanical system (MEMS) mirror with a high reflectivity plate and two-level-ladder double S-shaped electrothermal bimorph actuators. The fully assembled probe has a total outer diameter of 4 mm including all elements. With a two-lens configuration and a small aperture MEMS mirror, this probe can generate a large optical scan angle of 24° with 4 V drive voltage and can achieve a 450 µm FOV with a 2-fps frame rate. A uniform Pixel Dwell Time and a stable scanning speed along a raster pattern were demonstrated while a 57-fs pulse duration of the excitation beam was measured at the exit of the probe head. This miniature imaging probe will be coupled to a two-photon fluorescence endomicroscope oriented towards clinical use.