Mathieu Baijot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mathieu Baijot has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Chun Zhao
School of Physics, Engineering, and Technology, and York Biomedical Research Institute, University of York, York, U.K.
3 shared publications - Michael Kraft
KU Leuven
3 shared publications - Chen Wang
Department of Electrical Engineering (ESAT-MNS), KU Leuven, Leuven, Belgium
2 shared publications - Alain Vanderplasschen
Immunology-Vaccinology, Department of Infectious and Parasitic Diseases, Fundamental and Applied Research for Animals & Health (FARAH), Faculty of Veterinary Medicine, University of Liège, B-4000 Liège, Belgium
1 shared publication - Ali Ghorbani
University of Liege, Department of Electrical Engineering and Computer Science, Montefiore Institute, 4000 Liege, Belgium
1 shared publication - Chen Wang
College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication
Latest Publications
- Open Access
Monitoring Lower Back Activity in Daily Life Using Small Unintrusive Sensors and Wearable Electronics in the Context of Rheumatic and Musculoskeletal Diseases
Due to a sedentary lifestyle, the amount of people suffering from musculoskeletal back diseases has increased over the last few decades. To monitor and cure these disabilities, sensors able to monitor the patient for long-term measurement during daily life and able to provide real-time feedback are required. There are only a few wearable systems that are capable to acquire muscle activity (sEMG) and posture at the same time. Moreover, previously reported systems do not target back sensor and typically comprise bulky uncomfortable solutions. In this paper, we present a new wearable sensor network that is designed to measure muscle activity and posture specialized for back measurement. Special care was taken to propose a discrete and comfortable solution. The prototype only measures 3.1 mm in thickness on the spine, making this sensor system the thinnest and lightest one in the literature to our best knowledge. After testing, it was shown that the sensor system is able to acquire two surface electromyography signals concurrently, to gather acceleration and rotation speed from the patient’s lower back, and to transmit data to a computer or a smartphone via serial communication or Bluetooth low energy for a few hours for later processing and analysis.
Open AccessMonitoring Lower Back Activity in Daily Life Using Small Unintrusive Sensors and Wearable Electronics in the Context of Rheumatic and Musculoskeletal Diseases
Due to a sedentary lifestyle, the amount of people suffering from musculoskeletal back diseases has increased over the last few decades. To monitor and cure these disabilities, sensors able to monitor the patient for long-term measurement during daily life and able to provide real-time feedback are required. There are only a few wearable systems that are capable to acquire muscle activity (sEMG) and posture at the same time. Moreover, previously reported systems do not target back sensor and typically comprise bulky uncomfortable solutions. In this paper, we present a new wearable sensor network that is designed to measure muscle activity and posture specialized for back measurement. Special care was taken to propose a discrete and comfortable solution. The prototype only measures 3.1 mm in thickness on the spine, making this sensor system the thinnest and lightest one in the literature to our best knowledge. After testing, it was shown that the sensor system is able to acquire two surface electromyography signals concurrently, to gather acceleration and rotation speed from the patient’s lower back, and to transmit data to a computer or a smartphone via serial communication or Bluetooth low energy for a few hours for later processing and analysis.
- Open Access
Micromachined Accelerometers with Sub-µg/√Hz Noise Floor: A Review
This paper reviews the research and development of micromachined accelerometers with a noise floor lower than 1 µg/√Hz. Firstly, the basic working principle of micromachined accelerometers is introduced. Then, different methods of reducing the noise floor of micromachined accelerometers are analyzed. Different types of micromachined accelerometers with a noise floor below 1 µg/√Hz are discussed. Such sensors can mainly be categorized into: (i) micromachined accelerometers with a low spring constant; (ii) with a large proof mass; (iii) with a high quality factor; (iv) with a low noise interface circuit; (v) with sensing schemes leading to a high scale factor. Finally, the characteristics of various micromachined accelerometers and their trends are discussed and investigated.
Open AccessMicromachined Accelerometers with Sub-µg/√Hz Noise Floor: A Review
This paper reviews the research and development of micromachined accelerometers with a noise floor lower than 1 µg/√Hz. Firstly, the basic working principle of micromachined accelerometers is introduced. Then, different methods of reducing the noise floor of micromachined accelerometers are analyzed. Different types of micromachined accelerometers with a noise floor below 1 µg/√Hz are discussed. Such sensors can mainly be categorized into: (i) micromachined accelerometers with a low spring constant; (ii) with a large proof mass; (iii) with a high quality factor; (iv) with a low noise interface circuit; (v) with sensing schemes leading to a high scale factor. Finally, the characteristics of various micromachined accelerometers and their trends are discussed and investigated.
- 1 August 2018
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 279, 254-262
A mass sensor based on 3-DOF mode localized coupled resonator under atmospheric pressure
- 1 August 2018
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 279, 254-262
A mass sensor based on 3-DOF mode localized coupled resonator under atmospheric pressure
- Open Access
- 11 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 493
A Reversible Method to Characterize the Mass Sensitivity of a 3-Dof Mode Localized Coupled Resonator under Atmospheric Pressure
In this paper, for the first time, the mass sensitivity of a 3-DoF mode localized electrostatic coupled resonator was characterized under atmospheric pressure. A reversible method was used in which nanoparticles are added on and removed from one resonator of the 3-DOF coupled resonator system. Besides, a comparison of three mass sensitivity characterization methods was carried out: resonance frequency shift, amplitude change and resonance vibration amplitude ratio. The results show that a 3-DOF mode localized coupled resonator has potential to be employed for biosensing applications.
- 11 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 493
Open AccessA Reversible Method to Characterize the Mass Sensitivity of a 3-Dof Mode Localized Coupled Resonator under Atmospheric Pressure
In this paper, for the first time, the mass sensitivity of a 3-DoF mode localized electrostatic coupled resonator was characterized under atmospheric pressure. A reversible method was used in which nanoparticles are added on and removed from one resonator of the 3-DOF coupled resonator system. Besides, a comparison of three mass sensitivity characterization methods was carried out: resonance frequency shift, amplitude change and resonance vibration amplitude ratio. The results show that a 3-DOF mode localized coupled resonator has potential to be employed for biosensing applications.