Wenhua Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenhua Cai has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Sakdirat Kaewunruen
Department of Civil Engineering, School of Engineering, University of Birmingham, Birmingham B15 2TT, UK
2 shared publications Bujun Yu
Department of Civil Engineering Yancheng Institute of Technology Yancheng China ycit.edu.cn
1 shared publication- Bujun Yu
Department of Civil Engineering, Yancheng Institute of Technology, Yancheng 224051, China
1 shared publication Fajong Wu
Department of Civil Engineering Yancheng Institute of Technology Yancheng China ycit.edu.cn
1 shared publicationJianhua Shao
School of Civil Engineering and Architecture Jiangsu University of Science and Technology Zhenjiang China just.edu.cn
1 shared publication- Kai Wang
Department of Civil Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Seismic Response and Vibration Reduction Analysis of Suspended Structure under Wave Passage Excitation
In order to study the influence of traveling wave effect on the seismic response and damping effect of suspended structure, a series of shaking table tests of the 1 : 20 suspended structure have been carried out to compare and analyze the dynamic responses of suspended structures under two points and a consistent input. The vibration damping effect and vibration reduction law of suspended structure are discussed at different apparent wave velocity and in the different connection. The research shows that the damping suspended structure has a good damping effect, and the amplitude reduction of the top displacement peak response is up to 15%, which corresponds to smaller apparent velocities. Moreover, the upper bound of the maximum acceleration response at the structures’ top under nonuniform input motions equals that of the uniform motion. However, there is a hysteresis in the acceleration response under wave travelling excitations, and the smaller the apparent wave velocity, the more obvious the hysteresis.
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Open AccessSeismic Response and Vibration Reduction Analysis of Suspended Structure under Wave Passage Excitation
In order to study the influence of traveling wave effect on the seismic response and damping effect of suspended structure, a series of shaking table tests of the 1 : 20 suspended structure have been carried out to compare and analyze the dynamic responses of suspended structures under two points and a consistent input. The vibration damping effect and vibration reduction law of suspended structure are discussed at different apparent wave velocity and in the different connection. The research shows that the damping suspended structure has a good damping effect, and the amplitude reduction of the top displacement peak response is up to 15%, which corresponds to smaller apparent velocities. Moreover, the upper bound of the maximum acceleration response at the structures’ top under nonuniform input motions equals that of the uniform motion. However, there is a hysteresis in the acceleration response under wave travelling excitations, and the smaller the apparent wave velocity, the more obvious the hysteresis.
- Open Access
- 12 August 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (16) , 3299
Experimental Investigations into Earthquake Resistance of Steel Frame Retrofitted by Low-Yield-Point Steel Energy Absorbers
This paper is the world’s first to highlight an experimental investigation into the earthquake responses of a steel frame retrofitted by novel metallic bending energy absorbers made of low-yield-point steel with the yield strength of approximately 100 MPa. New results have been achieved by conducting comprehensive shaking table tests on a quarter-scaled model of a two-story, one-span building structure subjected to incremental intensity levels of input earthquake records. The detailed information of the specimens, material properties, monitoring sensors, and dynamic loading mechanisms has been presented. The experimental results in terms of seismic phenomena, dynamic characteristics, acceleration, inter-story drift ratios, and strain distributions are also analyzed by the data collected from a wide range of sensors. It is found that the seismic failure of the specimens depends largely on the energy absorbers, which dissipate the majority of seismic input energy in order to prevent the parent steel frame from being damaged by a severe earthquake. In addition, the retrofitted structure sufficiently satisfies the design criteria considering allowable drift limits under both frequent and rare earthquakes. This indicates the influential role of the novel low-yield-point absorber, in that the overall seismic performance of the retrofitted structure can be improved adequately for survival in high-intensity seismic fortification areas.
- 12 August 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (16) , 3299
Open AccessExperimental Investigations into Earthquake Resistance of Steel Frame Retrofitted by Low-Yield-Point Steel Energy Absorbers
This paper is the world’s first to highlight an experimental investigation into the earthquake responses of a steel frame retrofitted by novel metallic bending energy absorbers made of low-yield-point steel with the yield strength of approximately 100 MPa. New results have been achieved by conducting comprehensive shaking table tests on a quarter-scaled model of a two-story, one-span building structure subjected to incremental intensity levels of input earthquake records. The detailed information of the specimens, material properties, monitoring sensors, and dynamic loading mechanisms has been presented. The experimental results in terms of seismic phenomena, dynamic characteristics, acceleration, inter-story drift ratios, and strain distributions are also analyzed by the data collected from a wide range of sensors. It is found that the seismic failure of the specimens depends largely on the energy absorbers, which dissipate the majority of seismic input energy in order to prevent the parent steel frame from being damaged by a severe earthquake. In addition, the retrofitted structure sufficiently satisfies the design criteria considering allowable drift limits under both frequent and rare earthquakes. This indicates the influential role of the novel low-yield-point absorber, in that the overall seismic performance of the retrofitted structure can be improved adequately for survival in high-intensity seismic fortification areas.
- Open Access
- 28 June 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (13) , 2616
Shaking Table Tests of Suspended Structures Equipped with Viscous Dampers
In this study, a series of shaking table tests of a ten storey concrete suspended structure equipped with viscous dampers were carried out to evaluate the dynamic responses and vibration damping performance of suspended structures. The effects of link types between the primary structure and suspended floors and different seismic excitations on the response of suspended structure models was verified. The responses include the damping ratio, the frequency, maximum relative displacements, accelerations and maximum strains of the suspended structures. Test results showed that the damping ratio and the frequency of suspended structures installed with dampers (called damping suspended structure) are adjusted compared with a conventional suspended structure with rigid-bar links (conventional suspended structure). Maximum relative displacements of the primary structure of the damping suspended structure were distinctly smaller than those of the conventional suspended structure. However, the maximum relative displacement between the primary structure and the suspended floors of the damping suspended structure was significantly larger than that of the conventional structure, indicating that the swing of the suspended floor can help dissipate seismic energy. The peak acceleration and acceleration amplification factors of the damping suspended structure were less than the conventional suspended structure. Moreover, the peak acceleration response of the damping suspended structure was slightly behind the conventional suspended structure. The damping suspended structure certainly had a considerable and stable reduction for strain response, and the maximum strain response was decreased by 42.3%–72.7% for the damping suspended structure compared with the conventional suspended structure.
- 28 June 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (13) , 2616
Open AccessShaking Table Tests of Suspended Structures Equipped with Viscous Dampers
In this study, a series of shaking table tests of a ten storey concrete suspended structure equipped with viscous dampers were carried out to evaluate the dynamic responses and vibration damping performance of suspended structures. The effects of link types between the primary structure and suspended floors and different seismic excitations on the response of suspended structure models was verified. The responses include the damping ratio, the frequency, maximum relative displacements, accelerations and maximum strains of the suspended structures. Test results showed that the damping ratio and the frequency of suspended structures installed with dampers (called damping suspended structure) are adjusted compared with a conventional suspended structure with rigid-bar links (conventional suspended structure). Maximum relative displacements of the primary structure of the damping suspended structure were distinctly smaller than those of the conventional suspended structure. However, the maximum relative displacement between the primary structure and the suspended floors of the damping suspended structure was significantly larger than that of the conventional structure, indicating that the swing of the suspended floor can help dissipate seismic energy. The peak acceleration and acceleration amplification factors of the damping suspended structure were less than the conventional suspended structure. Moreover, the peak acceleration response of the damping suspended structure was slightly behind the conventional suspended structure. The damping suspended structure certainly had a considerable and stable reduction for strain response, and the maximum strain response was decreased by 42.3%–72.7% for the damping suspended structure compared with the conventional suspended structure.