PBPauline Hall Barrientos

Pauline Hall Barrientos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pauline Hall Barrientos has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Predicting haemodialysis arteriovenous fistula outcomes using computational fluid dynamics and ferumoxytol-enhanced MRI

    by Robert Ker, George Hyde-Linaker, Pauline Hall Barrientos, David Brian Kingsmore, Sokratis Stoumpos, Asimina Kazakidi

    Objective: Arteriovenous fistulas (AVF) are the preferred vascular access for maintenance haemodialysis. However, AVF non-maturation occurs in up to 60% of patients, frequently caused by inadequate vascular remodelling or stenosis development. This study explores the relationships between AVF anatomy, haemodynamics and AVF outcomes by combining, uniquely, high-fidelity numerical simulations and state-of-the-art ferumoxytol-enhanced magnetic resonance imaging (Fe-MRI) in patients. Methods: Patients underwent Fe-MRI 6 weeks after AVF creation. A novel computational fluid dynamics (CFD) methodology was employed to rigorously investigate haemodynamic metrics, including wall shear stress (WSS) and oscillatory shear index (OSI), and quantify changes in the AVF lumen at 1 cm intervals along the proximal artery, anastomosis and AVF vein. The primary outcome was AVF success, defined as AVF usage (assisted or unassisted) for dialysis for at least 3 months. ROC analysis was conducted to assess anatomical predictors of AVF flows of ⩾1000 ml/min. Results: The analysis included 17 AVFs (13 successful, 4 failed). Compared to failed fistulas, successful AVFs had higher mean WSS and OSI. Failed AVFs exhibited different haemodynamics, including lower flow rates with less helical flow. On ROC analysis, the three metrics associated with the highest area under the curve (AUC) values were the feeding artery curvature (0.82) and diameter (0.76), and draining vein diameter (0.74), with a combined AUC value of 0.83. Conclusion: These data suggest that high WSS, OSI, larger feeding artery and draining vein diameters and lower feeding artery curvature are associated with successful AVF outcomes. Whilst venous parameters are important, this study highlights the critical role of feeding artery characteristics, particularly diameter and curvature. These findings provide significant insights into the role of haemodynamics and geometry in modulating AVF maturation, suggesting that incorporation of arterial metrics into preoperative assessments could enhance surgical decision-making for more reliable AVF maturation and better long-term outcomes in haemodialysis patients.

  • Open Access

    Socioeconomic deprivation and illness trajectory in the Scottish population after COVID-19 hospitalization

    by Andrew J. Morrow, Robert Sykes, Merna Saleh, Baryab Zahra, Alasdair MacIntosh, Anna Kamdar, Catherine Bagot, Hannah K. Bayes, Kevin G. Blyth, Heerajnarain Bulluck, et al.

    Background: The associations between deprivation and illness trajectory after hospitalisation for coronavirus disease-19 (COVID-19) are uncertain. Methods: A prospective, multicentre cohort study was conducted on post-COVID-19 patients, enrolled either in-hospital or shortly post-discharge. Two evaluations were carried out: an initial assessment and a follow-up at 28–60 days post-discharge. The study encompassed research blood tests, patient-reported outcome measures, and multisystem imaging (including chest computed tomography (CT) with pulmonary and coronary angiography, cardiovascular and renal magnetic resonance imaging). Primary and secondary outcomes were analysed in relation to socioeconomic status, using the Scottish Index of Multiple Deprivation (SIMD). The EQ-5D-5L, Brief Illness Perception Questionnaire (BIPQ), Patient Health Questionnaire-4 (PHQ-4) for Anxiety and Depression, and the Duke Activity Status Index (DASI) were used to assess health status. Results: Of the 252 enrolled patients (mean age 55.0 ± 12.0 years; 40% female; 23% with diabetes), deprivation status was linked with increased BMI and diabetes prevalence. 186 (74%) returned for the follow-up. Within this group, findings indicated associations between deprivation and lung abnormalities (p = 0.0085), coronary artery disease (p = 0.0128), and renal inflammation (p = 0.0421). Furthermore, patients with higher deprivation exhibited worse scores in health-related quality of life (EQ-5D-5L, p = 0.0084), illness perception (BIPQ, p = 0.0004), anxiety and depression levels (PHQ-4, p = 0.0038), and diminished physical activity (DASI, p = 0.002). At the 3-month mark, those with greater deprivation showed a higher frequency of referrals to secondary care due to ongoing COVID-19 symptoms (p = 0.0438). However, clinical outcomes were not influenced by deprivation. Conclusions: In a post-hospital COVID-19 population, socioeconomic deprivation was associated with impaired health status and secondary care episodes. Deprivation influences illness trajectory after COVID-19.


  • Open Access

    Patient-specific computational haemodynamics associated with the surgical creation of an arteriovenous fistula

    by George Hyde-Linaker, Pauline Hall Barrientos, Sokratis Stoumpos, David Brian Kingsmore, Asimina Kazakidi

    Despite arteriovenous fistulae (AVF) being the preferred vascular access for haemodialysis, high primary failure rates (30-70%) and low one-year patency rates (40-70%) hamper their use. Furthermore, AVF creation has been associated with haemodynamic changes causing maladaptive cardiac remodelling leading to cardiovascular (CV) complications. In this study, we present a new workflow for characterising the haemodynamic profile prior to and following surgical creation of a successful left radiocephalic AVF in a 20-year-old end-stage kidney disease patient. The reconstructed vasculature was generated using multiple ferumoxytol-enhanced magnetic resonance angiography (FeMRA) datasets. Computational fluid dynamics (CFD) simulations utilising a scale-resolving turbulence model were completed to investigate the changes in the proximal haemodynamics following AVF creation, in addition to the post-AVF juxta-anastomosis flow patterns, which is impractical to obtain in-vivo. Following AVF creation, a significant 2-3-fold increase in blood flow rate was induced downstream of the left subclavian artery. This was validated through comparison with post-AVF patient-specific phase-contrast data. Proximal to the anastomosis, the increased flow rate yielded an increase in time-averaged wall shear stress (WSS), which is a key marker of adaptive vascular remodelling. In the juxta-anastomosis region, the success of the AVF was discussed with respect to the National Kidney Foundation's vascular access guidelines, where the patient-specific AVF met the flow rate and geometry criterion. The AVF venous diameter exceeded 6mm and the venous flow rate surpassed 600mL/min. This workflow may potentially be significant clinically when applied to multi-patient cohorts, with population-wide patient-specific conclusions being ascertained for the haemodynamic assessment of AVFs and improved surgical planning.


  • Open Access

    A pilot study investigating the use of 4D flow MRI for the assessment of splanchnic flow in patients suspected of mesenteric ischaemia

    by Pauline Hall Barrientos, Katrina Knight, Douglas Black, Alexander Vesey, Giles Roditi

    The most common cause of chronic mesenteric ischaemia is atherosclerosis which results in limitation of blood flow to the gastrointestinal tract. This pilot study aimed to evaluate 4D flow MRI as a potential tool for the analysis of blood flow changes post-prandial within the mesenteric vessels. The mesenteric vessels of twelve people were scanned; patients and healthy volunteers. A baseline MRI scan was performed after 6 h of fasting followed by a post-meal scan. Two 4D flow datasets were acquired, over the superior mesenteric artery (SMA) and the main portal venous vessels. Standard 2D time-resolved PC-MRI slices were also obtained across the aorta above the coeliac trunk, superior mesenteric vein, splenic vein and portal vein (PV). In the volunteer cohort there was a marked increase in blood flow post-meal within the PV (p = 0.028), not seen in the patient cohort (p = 0.116). Similarly, there were significant flow changes within the SMA of volunteers (p = 0.028) but not for the patient group (p = 0.116). Our pilot data has shown that there is a significant haemodynamic response to meal challenge in the PV and SMA in normal subjects compared to clinically apparent CMI patients. Therefore, the interrogation of mesenteric venous vessels exclusively is a feasible method to measure post-prandial flow changes in CMI patients.


  • Open Access

    Image‐based computational fluid dynamics for estimating pressure drop and fractional flow reserve across iliac artery stenosis: A comparison with in‐vivo measurements

    by Simeon Skopalik, Pauline Hall Barrientos, James Matthews, Aleksandra Radjenovic, Patrick Mark, Giles Roditi, Manosh C. Paul

    Computational Fluid Dynamics (CFD) and time‐resolved phase‐contrast magnetic resonance imaging (PC‐MRI) are potential non‐invasive methods for the assessment of the severity of arterial stenoses. Fractional flow reserve (FFR) is the current “gold standard” for determining stenosis severity in the coronary arteries but is an invasive method requiring insertion of a pressure wire. CFD derived FFR (vFFR) is an alternative to traditional catheter derived FFR now available commercially for coronary artery assessment, however, it can potentially be applied to a wider range of vulnerable vessels such as the iliac arteries. In this study CFD simulations are used to assess the ability of vFFR in predicting the stenosis severity in a patient with a stenosis of 77% area reduction (>50% diameter reduction) in the right iliac artery. Variations of vFFR, overall pressure drop and flow split between the vessels were observed by using different boundary conditions. Correlations between boundary condition parameters and resulting flow variables are presented. The study concludes that vFFR has good potential to characterise iliac artery stenotic disease.


  • Open Access

    Consensus‐Based Technical Recommendations for Clinical Translation of Renal Phase Contrast MRI

    by Anneloes de Boer, Giulia Villa, Octavia Bane, Michael Bock, Eleanor F. Cox, Ilona A. Dekkers, Per Eckerbom, Maria A. Fernández‐Seara, Susan T. Francis, Bryan Haddock, et al.

    Background: Phase‐contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC‐MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC‐MRI as a clinically useful tool.Purpose: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC‐MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies.Study Type: Systematic consensus process using a modified Delphi method.Population: Not applicable.Sequence Field/Strength: Renal fast gradient echo‐based 2D PC‐MRI.Assessment: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4–10) years of experience in 2D PC‐MRI formulated consensus statements on renal 2D PC‐MRI in two rounds of surveys. Starting from a recently published systematic review article, literature‐based and data‐driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated.Statistical Tests: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60–74% agreement among the experts.Results: Among 60 statements, 57 (95%) achieved consensus after the second‐round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC‐MRI data acquisition, processing, and reporting.Data Conclusion: These recommendations might promote a widespread adoption of renal PC‐MRI, and may help foster the set‐up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC‐MRI.Level of Evidence: 1Technical Efficacy Stage: 1


  • Ferumoxytol MR Angiography versus Duplex US for Vascular Mapping before Arteriovenous Fistula Surgery for Hemodialysis

    by Sokratis Stoumpos, Alfred Tan, Pauline Hall Barrientos, Karen Stevenson, Peter C. Thomson, Ram Kasthuri, Aleksandra Radjenovic, David B. Kingsmore, Giles Roditi, Patrick B. Mark

    Ferumoxytol-enhanced68 MR angiography was superior to duplex US in the detection of central vein stenosis and arterial disease that correlated with outcomes of arteriovenous fistula surgery for hem... Background Duplex US is performed routinely for vascular mapping prior to arteriovenous fistula (AVF) creation for hemodialysis but cannot demonstrate the central vasculature. Ferumoxytol, an iron ...