Muthuraman Ponrajan Vikram
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Muthuraman Ponrajan Vikram has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Amrit Kumar Thakur
Department of Mechanical Engineering KPR Institute of Engineering and Technology Coimbatore India
3 shared publications- Christopher Sathiya Satchi
Department of Mechanical Engineering Saveetha School of Engineering, SIMATS Chennai India
3 shared publications - Rajendran Prabakaran
School of Mechanical Engineering, Yeungnam University, Gyeongsan, Republic of Korea
3 shared publications Erdem Cuce
Center for Research Impact & Outcome Chitkara University Rajpura Punjab India
2 shared publications- Huijin Xu
School of Merchant Marine, Shanghai Maritime University
2 shared publications Pinar Mert Cuce
Department of Architecture, Faculty of Engineering and Architecture Recep Tayyip Erdogan University Rize Turkey
2 shared publications
Latest Publications
- 20 April 2024
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 43 (4)
Assessing performance of an external compound parabolic concentrator solar collector with cascaded latent heat thermal storage
This study presents quantitative results of charging experiments conducted on cascaded thermal energy storage system (CTESS) integrated with external compound parabolic concentrator solar collector (XCPCSC). Increasing mass flow rate in 2‐stage CTESS integrated with XCPCSC resulted in a 30% reduction in initiation time of phase change materials (PCMs) during charging, with a higher mass flow rate of 0.025 kg/s. However, due to disparate melting point temperatures of PCMs, phase transition in the two‐stage CTESS did not occur simultaneously, leading to poor heat transfer rates within the CTESS. To address this, study extended number of phases from two to three, resulting in a 1.5‐fold increase in rate of heat transfer compared to 2‐stage PCM system. The simultaneous melting processes at various stages in the CTESS maximized energy absorption, leading to a 25% increase in system efficiency. Notably, the values of energy stored efficiency and over‐all efficiency reached their peak values of 95% and 60%, respectively, between t = 12.00 h and t = 13.00 h. This time period also saw a significant increase in collector efficiency to 72%. These quantitative findings highlight importance of mass flow rate and PCM arrangement in achieving efficient heat transfer and system performance in a CTESS integrated with XCPCSC.
- 20 April 2024
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 43 (4)
Assessing performance of an external compound parabolic concentrator solar collector with cascaded latent heat thermal storage
This study presents quantitative results of charging experiments conducted on cascaded thermal energy storage system (CTESS) integrated with external compound parabolic concentrator solar collector (XCPCSC). Increasing mass flow rate in 2‐stage CTESS integrated with XCPCSC resulted in a 30% reduction in initiation time of phase change materials (PCMs) during charging, with a higher mass flow rate of 0.025 kg/s. However, due to disparate melting point temperatures of PCMs, phase transition in the two‐stage CTESS did not occur simultaneously, leading to poor heat transfer rates within the CTESS. To address this, study extended number of phases from two to three, resulting in a 1.5‐fold increase in rate of heat transfer compared to 2‐stage PCM system. The simultaneous melting processes at various stages in the CTESS maximized energy absorption, leading to a 25% increase in system efficiency. Notably, the values of energy stored efficiency and over‐all efficiency reached their peak values of 95% and 60%, respectively, between t = 12.00 h and t = 13.00 h. This time period also saw a significant increase in collector efficiency to 72%. These quantitative findings highlight importance of mass flow rate and PCM arrangement in achieving efficient heat transfer and system performance in a CTESS integrated with XCPCSC.
- 31 May 2023
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 43 (1)
Experimental investigation in the selection of phase change materials based on thermal stratification effect in thermal energy storage system
This study aims to evaluate the effects of thermal stratification on thermal energy storage (TES) systems during the charging process and choose suitable phase change materials (PCMs) for various layers. The research revealed that fiberglass insulation of 60 mm thick significantly decreased natural convection losses and increased the TES system's potential for energy recovery. For constant heat load, the charging time increased with increasing HTF inlet temperature, but remained constant for the first TES layer at a specified flow rate, resulting in increased storage capacity with minimal heat loss to the surroundings. The solar collector efficiency was shown to be dependent on solar radiation and collector efficiency, with peak efficiency seen at specified periods. The lowest melting point of PCMs at each layer 68°C, 62.7°C, 57°C, and 50°C was chosen based on temperature graphs. For comparing stratification behavior, the “MIX” number versus non‐dimensional charging time plot was effective. Additional experiments are needed to assess the selected PCMs' charging and discharging properties.
- 31 May 2023
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 43 (1)
Experimental investigation in the selection of phase change materials based on thermal stratification effect in thermal energy storage system
This study aims to evaluate the effects of thermal stratification on thermal energy storage (TES) systems during the charging process and choose suitable phase change materials (PCMs) for various layers. The research revealed that fiberglass insulation of 60 mm thick significantly decreased natural convection losses and increased the TES system's potential for energy recovery. For constant heat load, the charging time increased with increasing HTF inlet temperature, but remained constant for the first TES layer at a specified flow rate, resulting in increased storage capacity with minimal heat loss to the surroundings. The solar collector efficiency was shown to be dependent on solar radiation and collector efficiency, with peak efficiency seen at specified periods. The lowest melting point of PCMs at each layer 68°C, 62.7°C, 57°C, and 50°C was chosen based on temperature graphs. For comparing stratification behavior, the “MIX” number versus non‐dimensional charging time plot was effective. Additional experiments are needed to assess the selected PCMs' charging and discharging properties.
- Open Access
An Overview of the State of the Art and Challenges in the Use of Gelling and Thickening Agents to Create Stable Thermal Energy Storage Materials
Building cooling and heating, solar-powered energy production, energy recovery, and other energy-consuming industries have all seen an increase in the use of cold/hot latent thermal energy storage (LH-TES). Through energy recovery, LH-TES that uses phase-change materials (PCMs) as a storage medium helps to close the energy supply and demand gap and raises the possibility of energy savings. However, the stability, thermal, physical, and chemical properties of the PCM play a major role in how effectively it can be used. In recent years, adding gelling and thickening agents (GTAs) has gained popularity apart from the nanoparticles (NPs) and nucleating triggers (NTs), particularly for the creation of stable PCMs. Therefore, the current work’s goal is to provide an overview of how GTAs are used in the process of developing reliable PCMs for TES applications. It has been found that using GTAs not only increased stability but also decreased sedimentation, leakage, and the supercooling degree (SCD). It was noted that the addition of a GTA with a weight percentage of 2–15% resulted in excellent stability with a negligible leakage rate and latent heat reduced by 3.6–35% after only 200 cycles. Furthermore, PCMs for solar-thermal and building heating systems in the medium-temperature range (21–61 °C) were mostly studied for their performance with GTAs, but no study for a cool TES application was reported. Most works have studied inorganic PCM components with GTAs, and a few reports are available for paraffin. However, the GTA blending resulted in reduced thermal performance due to a decrease in thermal conductivity, latent heat, and a rise in viscosity. Further, NTs and NPs with small amounts were seeded into the PCM-GTA for eradicating the SCD with enhanced TC and accelerated energy transfer.
Open AccessAn Overview of the State of the Art and Challenges in the Use of Gelling and Thickening Agents to Create Stable Thermal Energy Storage Materials
Building cooling and heating, solar-powered energy production, energy recovery, and other energy-consuming industries have all seen an increase in the use of cold/hot latent thermal energy storage (LH-TES). Through energy recovery, LH-TES that uses phase-change materials (PCMs) as a storage medium helps to close the energy supply and demand gap and raises the possibility of energy savings. However, the stability, thermal, physical, and chemical properties of the PCM play a major role in how effectively it can be used. In recent years, adding gelling and thickening agents (GTAs) has gained popularity apart from the nanoparticles (NPs) and nucleating triggers (NTs), particularly for the creation of stable PCMs. Therefore, the current work’s goal is to provide an overview of how GTAs are used in the process of developing reliable PCMs for TES applications. It has been found that using GTAs not only increased stability but also decreased sedimentation, leakage, and the supercooling degree (SCD). It was noted that the addition of a GTA with a weight percentage of 2–15% resulted in excellent stability with a negligible leakage rate and latent heat reduced by 3.6–35% after only 200 cycles. Furthermore, PCMs for solar-thermal and building heating systems in the medium-temperature range (21–61 °C) were mostly studied for their performance with GTAs, but no study for a cool TES application was reported. Most works have studied inorganic PCM components with GTAs, and a few reports are available for paraffin. However, the GTA blending resulted in reduced thermal performance due to a decrease in thermal conductivity, latent heat, and a rise in viscosity. Further, NTs and NPs with small amounts were seeded into the PCM-GTA for eradicating the SCD with enhanced TC and accelerated energy transfer.
- Top Cited Papers
- 30 March 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 405
Renewable energy potential towards attainment of net-zero energy buildings status – A critical review
- 30 March 2023
- Published by Elsevier in Journal of Cleaner Production
- Vol. 405
Top Cited PapersRenewable energy potential towards attainment of net-zero energy buildings status – A critical review
- 9 December 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 9 (5) , 2628-2661
Advancement in graphene-based nanocomposites as high capacity anode materials for sodium-ion batteries
This review provides a path to achieve economic, safe, and energy-efficient graphene composites as anode materials for high-energy sodium-ion batteries.
- 9 December 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 9 (5) , 2628-2661
Advancement in graphene-based nanocomposites as high capacity anode materials for sodium-ion batteries
This review provides a path to achieve economic, safe, and energy-efficient graphene composites as anode materials for high-energy sodium-ion batteries.
- 21 July 2020
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 40 (1)
Optimization of a solar water heating system for vapor absorption refrigeration system
In this work, the optimization study of the solar collector integrated, with a thermal energy storage tank for the vapor absorption refrigeration system, was studied using TRNSYS. The performance of the integrated system was evaluated considering major contributing parameters such as solar collector area, the mass flow rate of the operating fluids, storage tank volume and height, absorber plate thickness, tube spacing, absorber tube diameter, insulation thickness, and glass thickness/properties, respectively. A physical model of the complete solar water heating (SWH) and refrigeration system was developed followed by simulation studies of the major components for optimization, and finally, the obtained results were compared with the reported data for validation. The results indicated that, by using the solar power with a serpentine tube type flat plate collector of area 24 m2 and a storage volume to a specific collector area of about 60 Lm−2, the optimized system could meet 65% of the annual thermal energy requirement for the refrigeration unit. Further, the annual performance of the optimized solar collector in terms of collector efficiency, heat removal factor, and overall heat loss coefficient was found to be about 0.32, 0.87, and 2.99 W m−2 K, respectively. In addition, the optimization approach that is adopted using TRNSYS in the present study could be used for optimizing the solar‐based energy system for various applications.
- 21 July 2020
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 40 (1)
Optimization of a solar water heating system for vapor absorption refrigeration system
In this work, the optimization study of the solar collector integrated, with a thermal energy storage tank for the vapor absorption refrigeration system, was studied using TRNSYS. The performance of the integrated system was evaluated considering major contributing parameters such as solar collector area, the mass flow rate of the operating fluids, storage tank volume and height, absorber plate thickness, tube spacing, absorber tube diameter, insulation thickness, and glass thickness/properties, respectively. A physical model of the complete solar water heating (SWH) and refrigeration system was developed followed by simulation studies of the major components for optimization, and finally, the obtained results were compared with the reported data for validation. The results indicated that, by using the solar power with a serpentine tube type flat plate collector of area 24 m2 and a storage volume to a specific collector area of about 60 Lm−2, the optimized system could meet 65% of the annual thermal energy requirement for the refrigeration unit. Further, the annual performance of the optimized solar collector in terms of collector efficiency, heat removal factor, and overall heat loss coefficient was found to be about 0.32, 0.87, and 2.99 W m−2 K, respectively. In addition, the optimization approach that is adopted using TRNSYS in the present study could be used for optimizing the solar‐based energy system for various applications.