EREduardo Galia Reston

Eduardo Galia Reston

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eduardo Galia Reston has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Color variation of composite resins in relation to the Vita Classical shade guide

    by João Vitor Andrade Denadai, Roberto Zimmer, Eduardo Galia Reston, Guilherme Anziliero Arossi

    Aim: The aim of this study was to verify the color variation between different composite resins and the Vita Classical Shade Guide. Methods: Two-millimeter thickness samples were made (n = 6) from eight commercial brands of composite resin (shade A2): Charisma (Kulzer), Forma (Ultradent), Harmonize (Kerr), Luna (SDI), Opallis (FGM), Oppus Bulk Fill (FGM), Vittra (FGM) and Filtek Z250 XT (3M ESPE). Specimens were stored in distilled water for 7 days and then polished. Color measurements of samples and A2 shade of the Vita Classical Shade Guide were performed using the Vita Easy Shade Advance 4.0 spectrophotometer on a black background. Color variations were calculated using the CIEDE2000 formula, considering values ≥0.81 being noticeable by the human eye and ≥1.77 being clinically unacceptable. Results were statistically analyzed with a 5% significance level. Results: Color variation (ΔE) of composite (E1 ) compared to the Vita Classical Shade Guide (E0 ) was greater than clinically acceptable for all the materials evaluated in this study. Forma (ΔE=2.08 ± sd=0.47) and Filtek Z250 XT (2.50 ± 0.20) had the smallest amount of color variation values found in the results. Harmonize (3.32 ± 0.63) presented values similar to Filtek Z250 XT, but it was worse than Forma. Vittra (3.51 ± 0.28), Charisma (3.80 ± 0.20), Opallis (4.24 ± 0.30) and Luna (5.67 ± 0.20) did not differ among each other and presented higher color variation than Forma, Filtek Z350XT and Harmonize. Oppus Bulk Fill (13.94 ± 1.12) was the composite with the greatest color variation. Conclusions: The findings in this study show that attention should be taken when using the Vita Color Shade Guide for composite shade selection.


  • Open Access

    Cytotoxicity assessment of Bio-C Repair Íon+: A new calcium silicate-based cement

    by Celso Afonso Klein-Junior, Roberto Zimmer, Tãnyre Dobler, Vanessa Oliveira, Daniel Rodrigo Marinowic, Ahmet Özkömür, Eduardo Galia Reston

    Background. Direct pulp capping is a method designed to preserve the exposed dental pulp. Due to good biological, physical, and mechanical properties, new versions of calcium silicate-based materials have been developed as pulp capping materials. The present study aimed to evaluate the cytotoxic effects of four calcium silicate-based pulp capping materials, of which the Bio-C Repair Íon+ is still in an experimental phase. Methods. Biodentine, MTA Repair HP, Bio-C Repair, and Bio-C Repair Íon+ cements were dispensed in a metallic matrix to produce 125-mm3 specimens, which were immersed in Dulbecco’s Modified Eagle Medium (DMEM) to obtain extracts. NIH 3T3 cells were cultured and exposed to the extracts for 24 hours and seven days. Cell viability was assessed by the methyl tetrazolium test (MTT). The mean values for the experimental and control groups (without treatment) were compared by analysis of variance (ANOVA) and post hoc Tukey tests, considering a significance level of 5%. Results. All the tested materials demonstrated a reduction in cell viability (P<0.05). According to ISO 10993-5: 2009 (E), Bio-C Repair Íon+ exhibited mild and moderate cytotoxicity in the 24- hour and 7-day analyses, respectively. Bio-C Repair and Biodentine showed mild cytotoxicity, and MTA Repair HP exhibited moderate cytotoxicity at both intervals. Conclusion. The highest cell viability was demonstrated by Biodentine, MTA, and Repair HP, in descending order. Bio-C Repair and Bio-C Repair Íon+ showed moderate cytotoxicity, similar to MTA Repair HP in the 7-day analysis.


  • Open Access

    Influência do polimento na estabilidade de cor de uma resina composta após imersão em diferentes substâncias corantes

    by Nicole Ruppenthal Amaral, Fernando Freitas Portella, Roberto Zimmer, Eduardo Galia Reston, Guilherme Anziliero Arossi

    Objetivo: Avaliar o grau de pigmentação da resina composta imersa em água destilada, molho shoyu e vinho tinto, submetida a diferentes métodos de polimento. Método: Foram confeccionadas 90 espécimes de resina composta cor A2 esmalte (4 mm de diâmetro de topo, 3 mm de diâmetro de fundo e 2 mm de espessura), divididos igualmente em três grupos, de acordo com o tratamento superficial realizado (sem polimento, polimento com Diamond Pro e polimento com lixa). As 30 amostras de cada grupo foram divididas em três subgrupos (n=10) e imersas em diferentes soluções (água, molho shoyu e vinho tinto). A análise colorimétrica foi realizada previamente, 7 e 15 dias após a imersão das amostras nas soluções, com o auxílio de um colorímetro. Os dados foram submetidos aos testes de ANOVA/Tukey considerando um nível de significância de 5%. Resultados: Amostras imersas em água apresentaram pequena variação de cor (E=2,2), com exceção das que não receberam polimento (E=7,8). O vinho tinto apresentou significativo maior potencial de pigmentação (E=15), independente do método de polimento, enquanto o molho shoyu (E=11) demonstrou pigmentar com maior intensidade as amostras polidas com discos de lixa. Conclusões: É necessário fazer um acabamento e um polimento adequado na restauração de resina composta para que o grau de pigmentação seja o menor possível. Sobre os alimentos corantes, conclui-se que tanto o molho shoyu quanto o vinho tinto pigmentam a resina composta, porém o vinho pigmenta com uma intensidade maior.

  • Open Access

    Effect of heat treatment on cytotoxicity and polymerization of universal adhesives

    by Celso Afonso Klein-Junior, Kathleen Sobieray, Roberto Zimmer, Fernando Freitas Portella, Eduardo Galia Reston, Daniel Marinowic, Keiichi Hosaka

    To assess, in vitro, the influence of heat air treatment on cytotoxicity and degree of conversion (DC) of universal self-etch adhesives (Ambar Universal APS, Scotchbond Universal Adhesive, and Tetric N-Bond Universal) in an NIH/3T3 fibroblast cell culture. Samples were divided into three groups: 1) no heat treatment (control), 2) 37°C and 3) 60°C heat treatment before photopolymerization. Cytotoxicity was analyzed by MTT assay and the DC by FTIR. All adhesives heated at 60°C showed reduced cytotoxicity levels when compared with those heated at 37°C. In general, DC of Ambar Universal APS presented the highest DC than Scotchbond Universal Adhesive and Tetric N-Bond Universal, and the hot air treatment do not influence the conversion. Heat treatment at 60°C was able to reduce the cytotoxicity of universal self-etch adhesives, even, the heat treatment does not enhances the DC.


  • Open Access

    Effect of preheating on cytotoxicity and physicochemical properties of light-cured calcium-based cements.

    by Diana Borghetti, Roberto Zimmer, Fernando Portella, Eduardo Reston, Celso Klein-Junior, Daniel Marinowic, Keiichi Hosaka

    The aim of this study was to evaluate the degree of conversion, cytotoxicity, solubility and pH of photopolymerizable calciumbased cements submitted to preheating. The degree of conversion was analyzed by Fourier transform infrared, cytotoxicity by the MTT test and solubility through loss of mass. The data were subjected to statistical tests (ANOVA / Tukey's, p<0.05). The photopolymerizable materials showed a low degree of conversion, regardless of preheating. All materials caused a reduction in cell viability at 24 hours and 7 days, with the Dycal (control) being more cytotoxic. Heat had a positive effect on Biocal at 7 days. Dycal is the most soluble material. Heat had no effect on the solubility or pH of the polymerizable materials. It is concluded that photopolymerizable calcium-based cements have a low degree of conversion and are soluble, which results in mild to moderate cytotoxicity.


  • Open Access

    Evaluation of Tensile Bond Strength of Metallic Prefabricated Posts Cemented with Different Luting Agents

    by Morgana Vicentin, Fernando Freitas Portella, Eduardo Galia Reston, Carlos Braga, André Luis Bianchi, Guilherme Anzilliero Arossi

    Objective: To assess the tensile bond strength of prefabricated metal posts cemented with different luting agents. Material and Methods: Fifty single-rooted endodontically treated human teeth had their crowns cut, mounted into acrylic-resin blocks and then an 8mm depth post space were prepared. Prefabricated cylindrical metal posts were cemented using different luting agents: a zinc phosphate cement (SS White), a conventional glass ionomer cement (Vidrion C), two resin-modified glass ionomer cements (Vitremer and RelyX Luting 2) and a resin cement (RelyX ARC). Samples were stored in distilled water for seven days and then submitted to a tensile bond strength test until complete dislocation of the post. One-way analysis of variance and Tukey test for pairwise multiple comparisons were used to evaluate differences between luting agents. Results: Tensile bond strength was 563.88±203.41 N for zinc phosphate cement, 336.86 ± 137.64 N for Vidrion C, 515.24 ± 239.48 N for Vitremer, 828.47±433.99 N for RelyX Luting 2 and 1262.51 ± 356.29 for RelyX ARC. The Relyx ARC presented the highest tensile bond strength regard the luting agent tested (p< 0.05). Conclusion: RelyX ARC presented the higher tensile bond strength compared to the other luting agents evaluated.

  • Open Access

    Effect of At-home and In-office Bleaching on Marginal Microleakage in Composite Resin Restorations using Two Adhesive Systems

    by Celso A Klein, Douglas da Silva, Eduardo G Reston, Diana Lb Borghetti, Roberto Zimmer

    Aim: The aim of this study is to assess marginal microleakage of cervical cavities restored with composite resins and two different adhesive techniques subjected to at-home and in-office bleaching. Materials and methods: In this randomized, blind laboratory experiment, 60 bovine teeth recently extracted were collected and divided into six groups (n = 10 each group). The teeth received cervical cavity preparations (2 mm × 3 mm × 1 mm) with enamel margins. Two different adhesive systems were used (Single Bond 2 and Clearfil SE Bond), in addition to composite resin (Z250). Restored teeth received two different bleaching gels (Opalescence PF and Opalescence Boost). Teeth were thermocycled and analyzed under confocal laser scanning microscopy. Results: No significant differences were observed (p > 0.05) in microleakage scores between the two groups not subjected to bleaching nor between the four groups that received bleaching treatment (p > 0.05), regardless of the gel and adhesive system employed. However, when comparing nonbleached with bleached teeth, those not subjected to bleaching showed statistically lower marginal microleakage scores (p < 0.05). Data were statistically analyzed using the Kruskal–Wallis test followed by Student–Newman–Keuls post hoc test, with significance set at 5%. Conclusion: Marginal microleakage in composite resin restorations is influenced by the action of bleaching agents used both at-home and in-office, regardless of the adhesive system employed (total-etch or self-etch). Clinical significance: Both at-home and in-office bleaching agents have an influence on the adhesive interface of resin restorations, producing changes and inducing marginal leakage. How to cite this article: Klein Jr CA, da Silva D, Reston EG, Borghetti DLB, Zimmer R. Effect of At-home and In-office Bleaching on Marginal Microleakage in Composite Resin Restorations using Two Adhesive Systems. J Contemp Dent Pract 2018;19(3):248-252.