Stephrene Seok Wei Chan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stephrene Seok Wei Chan has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Bingwen Eugene Fan
Department of Haematology, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore 308433, Singapore
3 shared publications - Shir Ying Lee
National University Cancer Institute, Singapore
2 shared publications - Allison Ching Yee Tso
Tan Tock Seng Hospital
1 shared publication Cheryl X.Q. Lim
National University Hospital
1 shared publicationChristian Aledia Gallardo
Lee Kong Chian School of Medicine Tan Tock Seng Hospital Singapore Singapore
1 shared publication- Christian Aledia Gallardo
Department of Haematology, Tan Tock Seng Hospital, Singapore, Singapore
1 shared publication
Latest Publications
- Open Access
- 13 March 2025
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 31
Diagnosis of Antiphospholipid Syndrome by Chemiluminescent or Enzyme-Linked Immunosorbent Assay – A Comparison Study and Comprehensive Literature Review
Objective: Enzyme-linked immunosorbent assay (ELISA) is the established method for detecting antiphospholipid antibodies (aPL) in the diagnosis of antiphospholipid syndrome (APS) but is labor-intensive compared with the newer automated chemiluminescent assay (CLIA). This study aims to evaluate CLIA versus ELISA for aPL, correlate each method with clinical manifestations and perform a comprehensive literature review. Methods: Patient samples were concurrently tested by ELISA (QUANTA Lite ® ) and CLIA (ACL AcuStar ® ) for anti-cardiolipin antibody (aCL) and anti-β2-glycoprotein-I (aβ2GPI) IgG and IgM. Assay results were correlated with any of the revised Sapporo APS clinical criteria. Results: Of the 107 patients, 67% fulfilled at least one clinical criterion. 38 patients (35.5%) had APS. For aCL IgG, aCL IgM and aβ2GPI IgM, CLIA showed above 77% concordance and fair to excellent agreement (Cohen's kappa 0.39–0.86) with moderate/high positive ELISA of ≥40 units. Both methods showed good correlation (Spearman's r 0.60–0.80, p < 0.0001) that was non-linear over the range of titers. CLIA sensitivity and specificity was 46%–100% and 68%–95%, with AUROC ranging from 0.80–0.93. For aβ2GPI IgG, concordance was 36.7% and agreement was low (kappa −0.23). Correlation with clinical criteria revealed no statistically significant difference in the occurrence of clinical manifestations in ELISA-positive versus CLIA-positive groups. Conclusions: aPL detection by CLIA showed close but incomplete concordance with ELISA. CLIA positivity correlated well with moderate/high ELISA positivity, but antibody titers should not be directly compared across systems. CLIA is an acceptable alternative to ELISA in the routine non-research setting. Our findings are congruent with the reviewed literature.
- 13 March 2025
- Published by SAGE Publications in Clinical and Applied Thrombosis/Hemostasis
- Vol. 31
Open AccessDiagnosis of Antiphospholipid Syndrome by Chemiluminescent or Enzyme-Linked Immunosorbent Assay – A Comparison Study and Comprehensive Literature Review
Objective: Enzyme-linked immunosorbent assay (ELISA) is the established method for detecting antiphospholipid antibodies (aPL) in the diagnosis of antiphospholipid syndrome (APS) but is labor-intensive compared with the newer automated chemiluminescent assay (CLIA). This study aims to evaluate CLIA versus ELISA for aPL, correlate each method with clinical manifestations and perform a comprehensive literature review. Methods: Patient samples were concurrently tested by ELISA (QUANTA Lite ® ) and CLIA (ACL AcuStar ® ) for anti-cardiolipin antibody (aCL) and anti-β2-glycoprotein-I (aβ2GPI) IgG and IgM. Assay results were correlated with any of the revised Sapporo APS clinical criteria. Results: Of the 107 patients, 67% fulfilled at least one clinical criterion. 38 patients (35.5%) had APS. For aCL IgG, aCL IgM and aβ2GPI IgM, CLIA showed above 77% concordance and fair to excellent agreement (Cohen's kappa 0.39–0.86) with moderate/high positive ELISA of ≥40 units. Both methods showed good correlation (Spearman's r 0.60–0.80, p < 0.0001) that was non-linear over the range of titers. CLIA sensitivity and specificity was 46%–100% and 68%–95%, with AUROC ranging from 0.80–0.93. For aβ2GPI IgG, concordance was 36.7% and agreement was low (kappa −0.23). Correlation with clinical criteria revealed no statistically significant difference in the occurrence of clinical manifestations in ELISA-positive versus CLIA-positive groups. Conclusions: aPL detection by CLIA showed close but incomplete concordance with ELISA. CLIA positivity correlated well with moderate/high ELISA positivity, but antibody titers should not be directly compared across systems. CLIA is an acceptable alternative to ELISA in the routine non-research setting. Our findings are congruent with the reviewed literature.
- 10 May 2022
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 44 (6) , 991-992
Zinc toxicity‐mimicker of myelodysplastic syndrome in both morphology and flow cytometry findings
- 10 May 2022
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 44 (6) , 991-992
Zinc toxicity‐mimicker of myelodysplastic syndrome in both morphology and flow cytometry findings
- 11 March 2022
- Published by Wiley in American Journal of Hematology
- Vol. 97 (6) , E189-E191
Single‐agent daratumumab for refractory POEMS syndrome
- 11 March 2022
- Published by Wiley in American Journal of Hematology
- Vol. 97 (6) , E189-E191
Single‐agent daratumumab for refractory POEMS syndrome
- 8 March 2022
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 44 (5) , 808-811
Acute Megakaryocytic Leukemia arising from Megakaryocyte/Erythroid Progenitor (MEP)‐like cell
- 8 March 2022
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 44 (5) , 808-811
Acute Megakaryocytic Leukemia arising from Megakaryocyte/Erythroid Progenitor (MEP)‐like cell
- Open Access
- 1 July 2020
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 42 (5) , E199-E203
Peripheral lymphocyte subset alterations in COVID‐19 patients
- 1 July 2020
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 42 (5) , E199-E203
Open AccessPeripheral lymphocyte subset alterations in COVID‐19 patients