Mayara dos Santos Noronha
Research Subjects
Mayara dos Santos Noronha has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Bruna Marin Fronza
Department of Restorative Dentistry, School of Dental Medicine, Albert Einstein Israelite Hospital, São Paulo, Brazil
1 shared publication - Bárbara Emanoele Costa Oliveira
Ceuma University, Brazil
1 shared publication - Carolina Bosso André
Federal University of Minas Gerais, Brazil
1 shared publication - Carolina Veloso Lima
Department of Dentistry UNINASSAU Teresina Brazil
1 shared publication - Caroline Delmaschi Ramos
Universidade Estadual de Londrina - UEL Residência Multiprofissional em Saúde da Família - RMSF Núcleo de Odontologia
1 shared publication - Claudia Silami Magalhães
Federal University of Minas Gerais
1 shared publication
Latest Publications
- Open Access
- 29 November 2021
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 21, e225042
Short-term effect of adhesive system on clinical performance of bulk fill composite
Aim: Although bulk fill composites have been widely used as restorative material, there is no consensus regarding the best clinical protocol in terms of composite technique and adhesive system. Therefore, this clinical trial evaluated the clinical performance of bulk fill composites for class I restorations under different protocols. Methods: A randomized clinical trial including 155 class I restorations was conducted using different adhesive systems: conventional technique (phosphoric acid + conventional three-step adhesive system) (Group 1, 2 and 3); or self-etching adhesive system (Groups 4, 5 and 6). Control groups 1 and 4 were restored with conventional composite; groups 2 and 5 with low viscosity bulk fill and conventional composite as occlusal coverage; groups 3 and 6 with high viscosity bulk fill. The FDI criteria was used for clinical evaluation at baseline and after 6 months. Results: All groups showed good clinical performance. At baseline, the adhesive system did not affect postoperative hypersensitivity. After 6 months, group 5 showed a significant reduction in color and translucency; group 6 a reduction in terms of anatomical form and for postoperative sensitivity and an improvement in patient satisfaction (p<0.05). Considering the same restorative technique, the use of the self-etching adhesive system showed a significant decrease in color and translucency (p<0.05). Conclusion: All groups showed favorable clinical performance, and promising results were found for the conventional adhesive system and high viscosity bulk fill protocol.
- 29 November 2021
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 21, e225042
Open AccessShort-term effect of adhesive system on clinical performance of bulk fill composite
Aim: Although bulk fill composites have been widely used as restorative material, there is no consensus regarding the best clinical protocol in terms of composite technique and adhesive system. Therefore, this clinical trial evaluated the clinical performance of bulk fill composites for class I restorations under different protocols. Methods: A randomized clinical trial including 155 class I restorations was conducted using different adhesive systems: conventional technique (phosphoric acid + conventional three-step adhesive system) (Group 1, 2 and 3); or self-etching adhesive system (Groups 4, 5 and 6). Control groups 1 and 4 were restored with conventional composite; groups 2 and 5 with low viscosity bulk fill and conventional composite as occlusal coverage; groups 3 and 6 with high viscosity bulk fill. The FDI criteria was used for clinical evaluation at baseline and after 6 months. Results: All groups showed good clinical performance. At baseline, the adhesive system did not affect postoperative hypersensitivity. After 6 months, group 5 showed a significant reduction in color and translucency; group 6 a reduction in terms of anatomical form and for postoperative sensitivity and an improvement in patient satisfaction (p<0.05). Considering the same restorative technique, the use of the self-etching adhesive system showed a significant decrease in color and translucency (p<0.05). Conclusion: All groups showed favorable clinical performance, and promising results were found for the conventional adhesive system and high viscosity bulk fill protocol.
- 29 June 2020
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 32 (5) , 521-529
Effect of zirconia decontamination protocols on bond strength and surface wettability
Objective: To evaluate the effects of human saliva decontamination protocols on bond strength of resin cement to zirconia (Y‐PSZ), wettability, and microbial decontamination.Materials and methods: Zirconia plates were sandblasted and divided into (a) not contaminated, (b) contaminated with human saliva and: (c) not cleaned, (d) cleaned with air‐water spray, (e) cleaned with 70% ethanol, (f) cleaned with Ivoclean, or (g) cleaned with nonthermal atmospheric plasma (NTAP). The wettability and microbial decontamination of the surfaces were determined after saliva contamination or cleaning. Monobond Plus (Ivoclar Vivadent) was applied after cleaning, followed by Variolink LC (Ivoclar Vivadent). The samples were stored 1 week before shear bond strength (SBS) testing, and data (SBS and wettability) were analyzed by one‐way analysis of variance and Tukey test (α = .05).Results: Saliva contamination reduced SBS to zirconia compared to not contaminated. Both Ivoclean and NTAP produced higher SBS compared to not cleaned and were not significantly different from the not contaminated. Ivoclean produced the highest contact angle, and NTAP the lowest. With the exception of using just water‐spray, all cleaning protocols decontaminated the specimens.Conclusions: Both Ivoclean and NTAP overcame the effects of saliva contamination, producing an SBS to zirconia comparable to the positive control.Clinical significance: Dental ceramics should be cleaned prior to resin cementation to eliminate the effects of human saliva contamination, and Ivoclean and NTAP are considered suitable materials for this purpose.
- 29 June 2020
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 32 (5) , 521-529
Effect of zirconia decontamination protocols on bond strength and surface wettability
Objective: To evaluate the effects of human saliva decontamination protocols on bond strength of resin cement to zirconia (Y‐PSZ), wettability, and microbial decontamination.Materials and methods: Zirconia plates were sandblasted and divided into (a) not contaminated, (b) contaminated with human saliva and: (c) not cleaned, (d) cleaned with air‐water spray, (e) cleaned with 70% ethanol, (f) cleaned with Ivoclean, or (g) cleaned with nonthermal atmospheric plasma (NTAP). The wettability and microbial decontamination of the surfaces were determined after saliva contamination or cleaning. Monobond Plus (Ivoclar Vivadent) was applied after cleaning, followed by Variolink LC (Ivoclar Vivadent). The samples were stored 1 week before shear bond strength (SBS) testing, and data (SBS and wettability) were analyzed by one‐way analysis of variance and Tukey test (α = .05).Results: Saliva contamination reduced SBS to zirconia compared to not contaminated. Both Ivoclean and NTAP produced higher SBS compared to not cleaned and were not significantly different from the not contaminated. Ivoclean produced the highest contact angle, and NTAP the lowest. With the exception of using just water‐spray, all cleaning protocols decontaminated the specimens.Conclusions: Both Ivoclean and NTAP overcame the effects of saliva contamination, producing an SBS to zirconia comparable to the positive control.Clinical significance: Dental ceramics should be cleaned prior to resin cementation to eliminate the effects of human saliva contamination, and Ivoclean and NTAP are considered suitable materials for this purpose.
- Open Access
- 24 July 2018
- Published by Revista de Saude Publica do Parana in Revista de Saúde Pública do Paraná
- Vol. 1 (1) , 68-73
Uso de diamino fluoreto de prata em crianças atendidas em uma unidade básica de saúde do norte do Paraná
O presente estudo avaliou o uso e a aceitação de diamino fluoreto de prata (DFP) em criançasatendidas em uma Unidade Básica de Saúde (UBS) do Norte do Paraná, bem como o cumprimento do protocolomunicipal para aplicação do DFP. Prontuários (n=43) de crianças de0 a5 anos residentes na área de abrangênciada UBS foram analisados. Foram coletadas informações sobre idade da criança, utilização e indicação do DFP,dentes submetidos ao tratamento e quantidade de reaplicações. Observou-se que o DFP foi aplicado em 79% das crianças devido à Cárie Precoce na Infância (CPI), 60% dos dentes que receberam a aplicação do DFP eram posteriores e 86% dos responsáveis aceitaram utilizar o DFP. Portanto, conclui-se que o DFP tem sido utilizado no serviço público do Paraná e que o procedimento é aceito pela maioria dos responsáveis das crianças, mas o cumprimento do protocolo municipal para aplicação do DFP ainda merece atenção.
- 24 July 2018
- Published by Revista de Saude Publica do Parana in Revista de Saúde Pública do Paraná
- Vol. 1 (1) , 68-73
Open AccessUso de diamino fluoreto de prata em crianças atendidas em uma unidade básica de saúde do norte do Paraná
O presente estudo avaliou o uso e a aceitação de diamino fluoreto de prata (DFP) em criançasatendidas em uma Unidade Básica de Saúde (UBS) do Norte do Paraná, bem como o cumprimento do protocolomunicipal para aplicação do DFP. Prontuários (n=43) de crianças de0 a5 anos residentes na área de abrangênciada UBS foram analisados. Foram coletadas informações sobre idade da criança, utilização e indicação do DFP,dentes submetidos ao tratamento e quantidade de reaplicações. Observou-se que o DFP foi aplicado em 79% das crianças devido à Cárie Precoce na Infância (CPI), 60% dos dentes que receberam a aplicação do DFP eram posteriores e 86% dos responsáveis aceitaram utilizar o DFP. Portanto, conclui-se que o DFP tem sido utilizado no serviço público do Paraná e que o procedimento é aceito pela maioria dos responsáveis das crianças, mas o cumprimento do protocolo municipal para aplicação do DFP ainda merece atenção.