Jintana Nammoonnoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jintana Nammoonnoy has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Gerald Joseph Kost
Pathology and Laboratory Medicine, School of Medicine, University of California, Davis, CA 95616, USA
1 shared publication - Napaporn Apiratmateekul
Reference Materials and Innovation Research Unit for Medical Laboratory, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok 65000, Thailand
1 shared publication - Pajaree Konthonbut
Department of Occupational Health and Safety, Faculty of Public Health, Mahidol University, Bangkok 10400, Thailand
1 shared publication - Pornpimol Kongtip
Department of Occupational Health and Safety, Faculty of Public Health, Mahidol University, 420/1 Rajvidhi Road, Bangkok 10400, Thailand
1 shared publication - Sumate Pengpumkiat
Department of Occupational Health and Safety, Faculty of Public Health, Mahidol University, Bangkok 10400, Thailand
1 shared publication - Wanvisa Treebuphachatsakul
Reference Materials and Innovation Research Unit for Medical Laboratory, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok 65000, Thailand
1 shared publication
Latest Publications
- Open Access
- 11 April 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (8) , 799
Commutable Blood Materials from the Fixed-Cell Method for Performance Evaluation of Blood Glucose by a Glucose Meter
Glucose meters provide a rapid blood glucose status for evidence-based diagnosis, monitoring, and treatment of diabetes mellitus. We aimed to evaluate the commutability of processed blood materials (PBMs) and their use in the performance evaluation of glucose meters. Two PBMs obtained by the fixed-cell method were analyzed for homogeneity, stability, and commutability. The compatibility of ten pairs between mass spectrometry and each glucose meter was categorized as compatible (mean paired difference ≤ 5%) and incompatible (mean paired difference > 5%). The performance of glucose meter 1 (n = 767) and glucose meter 2 (n = 266) was assessed. The glucose in the PBMs remained homogenized and stable for at least 180 days. Six out of ten pairs had commutable PBMs. Commutability of PBMs was observed in both well-compatible and incompatible glucose results. Target glucose values from mass spectrometry were significantly different (p ≤ 0.05) from consensus values in one group of glucose meters. When commutable PBMs were used, glucose meter 1 showed better performance than glucose meter 2, and the percentage of satisfaction was associated when using target values for glucose from mass spectrometry and consensus values, but the performance of glucose meter 2 was not associated. PBM from a fixed-cell method could be mass produced with acceptable homogeneity and stability. Commutability testing of PBMs is required prior to use in the performance evaluation of glucose meters, as the commutability of glucose in the PBMs obtained by a fixed-cell method was variable and depended on the individual glucose meter.
- 11 April 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (8) , 799
Open AccessCommutable Blood Materials from the Fixed-Cell Method for Performance Evaluation of Blood Glucose by a Glucose Meter
Glucose meters provide a rapid blood glucose status for evidence-based diagnosis, monitoring, and treatment of diabetes mellitus. We aimed to evaluate the commutability of processed blood materials (PBMs) and their use in the performance evaluation of glucose meters. Two PBMs obtained by the fixed-cell method were analyzed for homogeneity, stability, and commutability. The compatibility of ten pairs between mass spectrometry and each glucose meter was categorized as compatible (mean paired difference ≤ 5%) and incompatible (mean paired difference > 5%). The performance of glucose meter 1 (n = 767) and glucose meter 2 (n = 266) was assessed. The glucose in the PBMs remained homogenized and stable for at least 180 days. Six out of ten pairs had commutable PBMs. Commutability of PBMs was observed in both well-compatible and incompatible glucose results. Target glucose values from mass spectrometry were significantly different (p ≤ 0.05) from consensus values in one group of glucose meters. When commutable PBMs were used, glucose meter 1 showed better performance than glucose meter 2, and the percentage of satisfaction was associated when using target values for glucose from mass spectrometry and consensus values, but the performance of glucose meter 2 was not associated. PBM from a fixed-cell method could be mass produced with acceptable homogeneity and stability. Commutability testing of PBMs is required prior to use in the performance evaluation of glucose meters, as the commutability of glucose in the PBMs obtained by a fixed-cell method was variable and depended on the individual glucose meter.
- Open Access
A Microfluidic Paper-Based Analytical Device for Type-II Pyrethroid Targets in an Environmental Water Sample
A detection method for type-II pyrethroids in an environmental water sample using a microfluidic paper-based analytical device (µPAD) is reported here. The detection approach is based on the formation of cyanide from the hydrolysis of type-II pyrethroids and the colorimetric detection of cyanide on a layer-based µPAD. Parafilm and inexpensive laminating pouches were used to create a hydrophobic barrier for the assay on the µPAD. This detection approach was selective to type-II pyrethroids in water for which an environmental water sample was tested. The calibration curves for cypermethrin, deltamethrin, cyhalothrin, and fenvalerate ranged from 2 to 40 µg/mL without sample preconcentration. The lower concentrations of type-II pyrethroids can be assessed by including a preconcentration step prior to the detection on a µPAD. This detection system provides an alternative platform for fast, semiquantitative testing for pesticide contamination in environmental surface water by allowing for portability, low reagent/sample consumption, and low-cost testing.
Open AccessA Microfluidic Paper-Based Analytical Device for Type-II Pyrethroid Targets in an Environmental Water Sample
A detection method for type-II pyrethroids in an environmental water sample using a microfluidic paper-based analytical device (µPAD) is reported here. The detection approach is based on the formation of cyanide from the hydrolysis of type-II pyrethroids and the colorimetric detection of cyanide on a layer-based µPAD. Parafilm and inexpensive laminating pouches were used to create a hydrophobic barrier for the assay on the µPAD. This detection approach was selective to type-II pyrethroids in water for which an environmental water sample was tested. The calibration curves for cypermethrin, deltamethrin, cyhalothrin, and fenvalerate ranged from 2 to 40 µg/mL without sample preconcentration. The lower concentrations of type-II pyrethroids can be assessed by including a preconcentration step prior to the detection on a µPAD. This detection system provides an alternative platform for fast, semiquantitative testing for pesticide contamination in environmental surface water by allowing for portability, low reagent/sample consumption, and low-cost testing.