Judy Blackbeard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Judy Blackbeard has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Alexandra Keegan
South Australian Water Corporation, 250 Victoria square, Adelaide 5000, Australia
1 shared publication - Andrew S. Ball
School of Science, STEM College, RMIT University, Melbourne, VIC 3000, Australia
1 shared publication - Andrew Salveson
Carollo Engineers, Walnut Creek, CA 94598, USA
1 shared publication - Aravind Surapaneni
Australian Research Council Training Centre for the Transformation of Australia’s Biosolids Resource, Royal Melbourne Institute of Technology University, Bundoora, VIC 3083, Australia
1 shared publication - Arturo Aburto-Medina
School of Science, RMIT University, Bundoora, VIC 3083, Australia
1 shared publication - Basma Khallaf
School of Science, RMIT University, Bundoora, VIC 3083, Australia
1 shared publication
Latest Publications
- Open Access
Improvement of Log Reduction Values Design Equations for Helminth Egg Management in Recycled Water
Understanding and managing the risk posed by helminth eggs (HE) is a key concern for wastewater engineers and public health regulators. The treatment processes that produce recycled water from sewage at wastewater treatment plants (WWTPs) rely on achieving a defined log10 reduction value (LRV) in HE concentration during the production of recycled water from sewage to achieve the guideline concentration of ≤1.0 HE/L. The total concentration of HE in sewage reaches thousands of HE/L in developing countries and therefore, an LRV of 4.0 is generally accepted to achieve a safe concentration in recycled water, as this will meet the guideline value. However, in many developed countries with good sanitation and public health standards, the HE concentration in sewage is generally <10 HE/L. Therefore, validation of the sewage treatment process relied on to achieve an LRV of 4.0 can be difficult. Because of these limitations, design equations to predict LRVs from hydraulic retention times (HRT), which are geographically non-specific, are commonly relied on to ensure the production of safe quality recycled water with respect to HE. However, these design equations could be further refined by defining the design and management of the treatment process in greater detail and thus be used more effectively for determining the LRV required. This paper discusses the limitations and possible improvements that could be applied to LRV design equations for predicting HE removal at WWTPs and identifies the data requirements to support these improvements. Several options for LRV design equations are proposed that could be validated experimentally or via the ongoing operation of WWTPs. These improvements have the potential to assist the rationalization of the HE removal requirements for specific treatment options, exposure scenarios and use of recycled water in agriculture.
Open AccessImprovement of Log Reduction Values Design Equations for Helminth Egg Management in Recycled Water
Understanding and managing the risk posed by helminth eggs (HE) is a key concern for wastewater engineers and public health regulators. The treatment processes that produce recycled water from sewage at wastewater treatment plants (WWTPs) rely on achieving a defined log10 reduction value (LRV) in HE concentration during the production of recycled water from sewage to achieve the guideline concentration of ≤1.0 HE/L. The total concentration of HE in sewage reaches thousands of HE/L in developing countries and therefore, an LRV of 4.0 is generally accepted to achieve a safe concentration in recycled water, as this will meet the guideline value. However, in many developed countries with good sanitation and public health standards, the HE concentration in sewage is generally <10 HE/L. Therefore, validation of the sewage treatment process relied on to achieve an LRV of 4.0 can be difficult. Because of these limitations, design equations to predict LRVs from hydraulic retention times (HRT), which are geographically non-specific, are commonly relied on to ensure the production of safe quality recycled water with respect to HE. However, these design equations could be further refined by defining the design and management of the treatment process in greater detail and thus be used more effectively for determining the LRV required. This paper discusses the limitations and possible improvements that could be applied to LRV design equations for predicting HE removal at WWTPs and identifies the data requirements to support these improvements. Several options for LRV design equations are proposed that could be validated experimentally or via the ongoing operation of WWTPs. These improvements have the potential to assist the rationalization of the HE removal requirements for specific treatment options, exposure scenarios and use of recycled water in agriculture.
- Open Access
Effectiveness and Energy Requirements of Pasteurisation for the Treatment of Unfiltered Secondary Effluent from a Municipal Wastewater Treatment Plant
Pasteurisation was investigated as a process to achieve high microbial quality standards in the recycling of water from unfiltered secondary effluents from a wastewater treatment plants in Melbourne, Australia. The relative heat sensitivity of key bacterial, viral, protozoan and helminth wastewater organisms (Escherichia coli, Enterococcus, FRNA bacteriophage, adenovirus, coxsackievirus, Cryptosporidium, and Ascaris) were determined by laboratory scale tests. The FRNA phage were found to be the most heat resistant, followed by enterococci and E. coli. Pilot scale challenge testing of a 2 ML/day pasteurisation pilot plant using unfiltered municipal wastewater and male specific coliphage (MS2) phage showed that temperatures between 69 °C and 75 °C achieved log reductions values between 0.9 ± 0.1 and 5.0 ± 0.5 respectively in the contact chamber. Fouling of the heat exchangers during operation using unfiltered secondary treated effluent was found to increase the energy consumption of the plant from 2.2 kWh/kL to 5.1 kWh/kL. The economic feasibility of pasteurisation for the current municipal application with high heat exchanger fouling potential can be expected to depend largely on the available waste heat from co-generation and on the efforts required to control fouling of the heat exchangers.
Open AccessEffectiveness and Energy Requirements of Pasteurisation for the Treatment of Unfiltered Secondary Effluent from a Municipal Wastewater Treatment Plant
Pasteurisation was investigated as a process to achieve high microbial quality standards in the recycling of water from unfiltered secondary effluents from a wastewater treatment plants in Melbourne, Australia. The relative heat sensitivity of key bacterial, viral, protozoan and helminth wastewater organisms (Escherichia coli, Enterococcus, FRNA bacteriophage, adenovirus, coxsackievirus, Cryptosporidium, and Ascaris) were determined by laboratory scale tests. The FRNA phage were found to be the most heat resistant, followed by enterococci and E. coli. Pilot scale challenge testing of a 2 ML/day pasteurisation pilot plant using unfiltered municipal wastewater and male specific coliphage (MS2) phage showed that temperatures between 69 °C and 75 °C achieved log reductions values between 0.9 ± 0.1 and 5.0 ± 0.5 respectively in the contact chamber. Fouling of the heat exchangers during operation using unfiltered secondary treated effluent was found to increase the energy consumption of the plant from 2.2 kWh/kL to 5.1 kWh/kL. The economic feasibility of pasteurisation for the current municipal application with high heat exchanger fouling potential can be expected to depend largely on the available waste heat from co-generation and on the efforts required to control fouling of the heat exchangers.