KMKazuhiro Miyachi

Kazuhiro Miyachi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kazuhiro Miyachi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cable-Stayed Bridge with S-Curved Girder: Shake Hands Bridge

    by Kazuhiro Miyachi, Shunichi Nakamura

    A cable-stayed pedestrian bridge with an S-curved girder called Shake Hands Bridge is proposed. This type of bridge overturns the traditional notion of linearly constructed cable-stayed bridges. Cables support the S-curved girder from intersecting inclined towers creating a three-dimensional effect. The aesthetic design of the proposed bridge is examined using a model, a 3D computer-aided design diagram, a computer graphics diagram and a video. The proposed bridge is attractive and impressive, in harmony with the surrounding environment, and is considered to have great presence and to be an attraction in itself. From a structural point of view, it is found that the inclined tower has the effect of reducing the axial force of the girder and the tower itself and suppressing bending of the girder. On the other hand, it is found that the S-curved girder is more affected by torsion than a straight girder, but that there is no problem with safety. In addition, deflection of the girder due to live loading also satisfies the allowable value, there is no problem due to vertical or horizontal vibration, and the serviceability is sufficiently secure. Therefore, the proposed bridge is considered to be highly feasible.


  • Correlation between the rust colour distribution rate and corroded surface characteristics of galvanized steel wires

    by Kazuhiro Miyachi, Atsuto Kajita

    This study investigated the correlation of the rust colour distribution rate provided by using a digital image colour analysis system and the corroded surface characteristics provided by using a non- contact surface mapping technique. The ratio of zinc-specific white rust to iron-specific red rust, which characterizes the corrosion status of bridge wires, can be quantified by introducing the digital image colour analysis system. Regarding the correlation between the rust colour distribution rate and the corrosion surface characteristics, it was found that the corrosion loss rate and the pit depth increase as the white rust rate decreases.


  • Corrosion investigation of longitudinal direction of corroded main cable on an actual suspension bridge

    by Kazuhiro Miyachi, Koji Kinoshita, Rina Hasuike, Yoshitomo Yano, Yosuke Hatasa

    In this study, in order to clarify the corrosion condition and longitudinal change of an actual suspension bridge main cable used for more than 50 years, the disassembly investigation was conducted based on the corrosion evaluation criteria applying the rust composition analysis. In the 6 ropes composing the main cable, from the comparison result of the disassembly investigation of all ropes, it was confirmed that the corrosion level on the rope surface tended to be relatively higher than inside. In addition, from the investigation results of the disassembly and the corrosion distribution rate in the longitudinal direction, it was clarified that even if the inside of the strand that composing rope was corroded at a certain cross section, the corrosion condition was changed during the twisting process. Furthermore, it was confirmed that the corrosion tends to progress between the outer strands.

  • Ultimate Strength and Chain-Reaction Failure of Hangers in Tied-Arch Bridges

    by Shunichi Nakamura, Kazuhiro Miyachi

    This study was motivated by the recent collapse of a tied-arch bridge with branched arch ribs. Hangers were successively broken when a heavy lorry crossed the bridge. In this article, the ultimate strength of tied-arch bridges, causes of hanger rope breakage and simulation of chain-reaction failure of hangers are studied for tied-arch bridges. Nonlinear finite element method analysis has clarified that this bridge model has sufficient ultimate strength. The hanger arrangement significantly affect the ultimate strength. The model with uniformly distributed hangers has higher ultimate strength and the hanger tensions are well balanced. Corrosion fatigue of wires could cause hanger rope breakage. The stress amplitude would be further amplified by secondary bending stresses, different safety factors, improper hanger tensions due to poor quality control, impact factors induced by moving vehicles, and effects of other vehicles. As the fatigue strength of corroded strands is significantly decreased, the estimated stress amplitude could cause hanger breakage. When a hanger breaks, the dead and live loads work impulsively, which are replaced by the equivalent static loads. The load is redistributed to the hanger next to the broken hanger, which induces the chain-reaction failure of hangers. This simulation method clarifies the mechanism of the bridge collapse.