Koen E. A. van der Bogt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Koen E. A. van der Bogt has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Joris I. Rotmans
Leiden University Medical Center, Leiden, The Netherlands
5 shared publications Adam F. Cohen
Centre for Human Drug Research, Leiden, the Netherlands
3 shared publicationsCoen R.H. Huizinga
Centre for Human Drug Research, Leiden, the Netherlands
3 shared publications- Daniël Eefting
Department of Surgery, Leiden University Medical Centre, Leiden, The Netherlands; Department of Surgery, Haaglanden Medical Centre, The Hague, The Netherlands; University Vascular Centre West, Leiden | The Hague | Delft, The Netherlands
3 shared publications - Jaap F. Hamming
Department of Vascular Surgery, Leiden University Medical Center, Leiden, The Netherlands
3 shared publications - Joost Renier van der Vorst
Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 15 June 2026
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 131, 261-270
Intraoperative Optimization of Radiocephalic Arteriovenous Fistula Surgery with Contemporary Techniques
- 15 June 2026
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 131, 261-270
Open AccessIntraoperative Optimization of Radiocephalic Arteriovenous Fistula Surgery with Contemporary Techniques
- Open Access
- 10 October 2025
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 13 (1) , e71994
Evaluation of Machine Learning Model Performance in Diabetic Foot Ulcer: Retrospective Cohort Study
Background: Machine learning (ML) has shown great potential in recognizing complex disease patterns and supporting clinical decision-making. Diabetic foot ulcers (DFUs) represent a significant multifactorial medical problem with high incidence and severe outcomes, providing an ideal example for a comprehensive framework that encompasses all essential steps for implementing ML in a clinically relevant fashion. Objective: This paper aims to provide a framework for the proper use of ML algorithms to predict clinical outcomes of multifactorial diseases and their treatments. Methods: The comparison of ML models was performed on a DFU dataset. The selection of patient characteristics associated with wound healing was based on outcomes of statistical tests, that is, ANOVA and chi-square test, and validated on expert recommendations. Imputation and balancing of patient records were performed with MIDAS (Multiple Imputation with Denoising Autoencoders) Touch and adaptive synthetic sampling, respectively. Logistic regression, support vector machine (SVM), k-nearest neighbors, random forest (RF), extreme gradient boosting (XGBoost), Bayesian additive regression trees, and artificial neural network were trained, cross-validated, and optimized using random sampling on the patient dataset. To evaluate model calibration and clinical utility, calibration curves, Brier scores, and decision curve analysis (DCA) were performed. Results: The exploratory dataset consisted of 700 patient records with 199 variables. After dataset cleaning, the variables used for model training included age, smoking status, toe systolic pressure, blood pressure, oxygen saturation, hemoglobin, hemoglobin A1c, estimated glomerular filtration rate, wound location, diabetes type, Texas wound classification, neuropathy, and wound area measurement. The SVM obtained a stable accuracy of 0.853 (95% CI 0.810-0.896) with an area under the receiver operating characteristic curve of 0.922 (95% CI 0.889-0.955). The RF and XGBoost acquired an accuracy of 0.838 (95% CI 0.793-0.883) and 0.815 (95% CI 0.768-0.862), respectively, with areas under the receiver operating characteristic curve of 0.917 (95% CI 0.883-0.951) for RF and 0.889 (95% CI 0.849-0.929) for XGBoost. SVM, RF, and XGBoost were well-calibrated, with average Brier scores around 0.127 (SD 0.013). DCA showed that the SVM provided the highest net clinical benefit across relevant risk thresholds. Conclusions: Handling missing values, feature selection, and addressing class imbalance are critical components of the key steps in developing ML applications for clinical research. Seven models were selected for comparing their predictive power regarding complete wound healing, and each model representing a different branch in ML. In this initial DFU dataset used as an example, the SVM achieved the best performance in predicting clinical outcomes, followed by RF and XGBoost. The model’s calibration and clinical utility were determined through calibration curves, Brier scores, and DCA, demonstrating its potential relevance in clinical decision-making.
- 10 October 2025
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 13 (1) , e71994
Open AccessEvaluation of Machine Learning Model Performance in Diabetic Foot Ulcer: Retrospective Cohort Study
Background: Machine learning (ML) has shown great potential in recognizing complex disease patterns and supporting clinical decision-making. Diabetic foot ulcers (DFUs) represent a significant multifactorial medical problem with high incidence and severe outcomes, providing an ideal example for a comprehensive framework that encompasses all essential steps for implementing ML in a clinically relevant fashion. Objective: This paper aims to provide a framework for the proper use of ML algorithms to predict clinical outcomes of multifactorial diseases and their treatments. Methods: The comparison of ML models was performed on a DFU dataset. The selection of patient characteristics associated with wound healing was based on outcomes of statistical tests, that is, ANOVA and chi-square test, and validated on expert recommendations. Imputation and balancing of patient records were performed with MIDAS (Multiple Imputation with Denoising Autoencoders) Touch and adaptive synthetic sampling, respectively. Logistic regression, support vector machine (SVM), k-nearest neighbors, random forest (RF), extreme gradient boosting (XGBoost), Bayesian additive regression trees, and artificial neural network were trained, cross-validated, and optimized using random sampling on the patient dataset. To evaluate model calibration and clinical utility, calibration curves, Brier scores, and decision curve analysis (DCA) were performed. Results: The exploratory dataset consisted of 700 patient records with 199 variables. After dataset cleaning, the variables used for model training included age, smoking status, toe systolic pressure, blood pressure, oxygen saturation, hemoglobin, hemoglobin A1c, estimated glomerular filtration rate, wound location, diabetes type, Texas wound classification, neuropathy, and wound area measurement. The SVM obtained a stable accuracy of 0.853 (95% CI 0.810-0.896) with an area under the receiver operating characteristic curve of 0.922 (95% CI 0.889-0.955). The RF and XGBoost acquired an accuracy of 0.838 (95% CI 0.793-0.883) and 0.815 (95% CI 0.768-0.862), respectively, with areas under the receiver operating characteristic curve of 0.917 (95% CI 0.883-0.951) for RF and 0.889 (95% CI 0.849-0.929) for XGBoost. SVM, RF, and XGBoost were well-calibrated, with average Brier scores around 0.127 (SD 0.013). DCA showed that the SVM provided the highest net clinical benefit across relevant risk thresholds. Conclusions: Handling missing values, feature selection, and addressing class imbalance are critical components of the key steps in developing ML applications for clinical research. Seven models were selected for comparing their predictive power regarding complete wound healing, and each model representing a different branch in ML. In this initial DFU dataset used as an example, the SVM achieved the best performance in predicting clinical outcomes, followed by RF and XGBoost. The model’s calibration and clinical utility were determined through calibration curves, Brier scores, and DCA, demonstrating its potential relevance in clinical decision-making.
- Open Access
- 14 April 2025
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (1) , 190-200
In vitro safety of power injection of contrast media through central venous hemodialysis catheters
Objective: Central venous catheters (CVCs) provide direct access to the central circulatory system, commonly used in hemodialysis and intensive care units for drug administration. Although uncertified for the procedure, CVCs are sometimes used for power injection of contrast medium (CM) during CT scans to avoid peripheral intravenous catheter placement. Previous studies suggest this practice is safe, but incidents are reported. This study aims to measure intraluminal pressure during CM injection through CVCs and assess its impact on the luminal surface to guide responsible clinical use. Materials and methods: An experimental in vitro test setup was developed. Four samples each of three different types of unused CVCs were used. Strain gauges were applied to the exterior walls of either the inflow or outflow lumen of the CVC. These gauges measured material deformation due to intraluminal pressure during CM injections at rates of 4.5 and 8 mL/s, each performed five times. Strain data were calibrated against known pressures in a static system. Three CVCs of each type were then pressurized until bursting, and one was subjected to microscopic analysis of the luminal surfaces. Results: Intraluminal pressures measured (97–545 kPa or 14–79 PSI) were below the burst pressure (779–1248 kPa or 113–181 PSI) in all instances. Strain regression analysis shows a statistically significant ( p < 0.01) trend over 10 injections in all CVCs tested except one, indicating material fatigue. Surface microscopy revealed surface micro-cracks from repeated injections, suggesting material damage. Conclusions: The intraluminal pressures from power injections of CM are sufficiently low to prevent CVC bursting. While incidental use for CM injection appears safe, repeated use may cause material damage.
- 14 April 2025
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (1) , 190-200
Open AccessIn vitro safety of power injection of contrast media through central venous hemodialysis catheters
Objective: Central venous catheters (CVCs) provide direct access to the central circulatory system, commonly used in hemodialysis and intensive care units for drug administration. Although uncertified for the procedure, CVCs are sometimes used for power injection of contrast medium (CM) during CT scans to avoid peripheral intravenous catheter placement. Previous studies suggest this practice is safe, but incidents are reported. This study aims to measure intraluminal pressure during CM injection through CVCs and assess its impact on the luminal surface to guide responsible clinical use. Materials and methods: An experimental in vitro test setup was developed. Four samples each of three different types of unused CVCs were used. Strain gauges were applied to the exterior walls of either the inflow or outflow lumen of the CVC. These gauges measured material deformation due to intraluminal pressure during CM injections at rates of 4.5 and 8 mL/s, each performed five times. Strain data were calibrated against known pressures in a static system. Three CVCs of each type were then pressurized until bursting, and one was subjected to microscopic analysis of the luminal surfaces. Results: Intraluminal pressures measured (97–545 kPa or 14–79 PSI) were below the burst pressure (779–1248 kPa or 113–181 PSI) in all instances. Strain regression analysis shows a statistically significant ( p < 0.01) trend over 10 injections in all CVCs tested except one, indicating material fatigue. Surface microscopy revealed surface micro-cracks from repeated injections, suggesting material damage. Conclusions: The intraluminal pressures from power injections of CM are sufficiently low to prevent CVC bursting. While incidental use for CM injection appears safe, repeated use may cause material damage.
- Open Access
- 6 February 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Evaluation of Machine Learning Model Performance in Diabetic Foot Ulcer: Retrospective Cohort Study (Preprint)
BACKGROUND Machine learning (ML) has shown great potential in recognizing complex disease patterns and supporting clinical decision-making. Diabetic foot ulcers (DFUs) represent a significant multifactorial medical problem with high incidence and severe outcomes, providing an ideal example for a comprehensive framework that encompasses all essential steps for implementing ML in a clinically relevant fashion. OBJECTIVE This paper aims to provide a framework for the proper use of ML algorithms to predict clinical outcomes of multifactorial diseases and their treatments. METHODS The comparison of ML models was performed on a DFU dataset. The selection of patient characteristics associated with wound healing was based on outcomes of statistical tests, that is, ANOVA and chi-square test, and validated on expert recommendations. Imputation and balancing of patient records were performed with MIDAS (Multiple Imputation with Denoising Autoencoders) Touch and adaptive synthetic sampling, respectively. Logistic regression, support vector machine (SVM), k-nearest neighbors, random forest (RF), extreme gradient boosting (XGBoost), Bayesian additive regression trees, and artificial neural network were trained, cross-validated, and optimized using random sampling on the patient dataset. To evaluate model calibration and clinical utility, calibration curves, Brier scores, and decision curve analysis (DCA) were performed. RESULTS The exploratory dataset consisted of 700 patient records with 199 variables. After dataset cleaning, the variables used for model training included age, smoking status, toe systolic pressure, blood pressure, oxygen saturation, hemoglobin, hemoglobin A1c, estimated glomerular filtration rate, wound location, diabetes type, Texas wound classification, neuropathy, and wound area measurement. The SVM obtained a stable accuracy of 0.853 (95% CI 0.810-0.896) with an area under the receiver operating characteristic curve of 0.922 (95% CI 0.889-0.955). The RF and XGBoost acquired an accuracy of 0.838 (95% CI 0.793-0.883) and 0.815 (95% CI 0.768-0.862), respectively, with areas under the receiver operating characteristic curve of 0.917 (95% CI 0.883-0.951) for RF and 0.889 (95% CI 0.849-0.929) for XGBoost. SVM, RF, and XGBoost were well-calibrated, with average Brier scores around 0.127 (SD 0.013). DCA showed that the SVM provided the highest net clinical benefit across relevant risk thresholds. CONCLUSIONS Handling missing values, feature selection, and addressing class imbalance are critical components of the key steps in developing ML applications for clinical research. Seven models were selected for comparing their predictive power regarding complete wound healing, and each model representing a different branch in ML. In this initial DFU dataset used as an example, the SVM achieved the best performance in predicting clinical outcomes, followed by RF and XGBoost. The model’s calibration and clinical utility were determined through calibration curves, Brier scores, and DCA, demonstrating its potential relevance in clinical decision-making. CLINICALTRIAL
- 6 February 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEvaluation of Machine Learning Model Performance in Diabetic Foot Ulcer: Retrospective Cohort Study (Preprint)
BACKGROUND Machine learning (ML) has shown great potential in recognizing complex disease patterns and supporting clinical decision-making. Diabetic foot ulcers (DFUs) represent a significant multifactorial medical problem with high incidence and severe outcomes, providing an ideal example for a comprehensive framework that encompasses all essential steps for implementing ML in a clinically relevant fashion. OBJECTIVE This paper aims to provide a framework for the proper use of ML algorithms to predict clinical outcomes of multifactorial diseases and their treatments. METHODS The comparison of ML models was performed on a DFU dataset. The selection of patient characteristics associated with wound healing was based on outcomes of statistical tests, that is, ANOVA and chi-square test, and validated on expert recommendations. Imputation and balancing of patient records were performed with MIDAS (Multiple Imputation with Denoising Autoencoders) Touch and adaptive synthetic sampling, respectively. Logistic regression, support vector machine (SVM), k-nearest neighbors, random forest (RF), extreme gradient boosting (XGBoost), Bayesian additive regression trees, and artificial neural network were trained, cross-validated, and optimized using random sampling on the patient dataset. To evaluate model calibration and clinical utility, calibration curves, Brier scores, and decision curve analysis (DCA) were performed. RESULTS The exploratory dataset consisted of 700 patient records with 199 variables. After dataset cleaning, the variables used for model training included age, smoking status, toe systolic pressure, blood pressure, oxygen saturation, hemoglobin, hemoglobin A1c, estimated glomerular filtration rate, wound location, diabetes type, Texas wound classification, neuropathy, and wound area measurement. The SVM obtained a stable accuracy of 0.853 (95% CI 0.810-0.896) with an area under the receiver operating characteristic curve of 0.922 (95% CI 0.889-0.955). The RF and XGBoost acquired an accuracy of 0.838 (95% CI 0.793-0.883) and 0.815 (95% CI 0.768-0.862), respectively, with areas under the receiver operating characteristic curve of 0.917 (95% CI 0.883-0.951) for RF and 0.889 (95% CI 0.849-0.929) for XGBoost. SVM, RF, and XGBoost were well-calibrated, with average Brier scores around 0.127 (SD 0.013). DCA showed that the SVM provided the highest net clinical benefit across relevant risk thresholds. CONCLUSIONS Handling missing values, feature selection, and addressing class imbalance are critical components of the key steps in developing ML applications for clinical research. Seven models were selected for comparing their predictive power regarding complete wound healing, and each model representing a different branch in ML. In this initial DFU dataset used as an example, the SVM achieved the best performance in predicting clinical outcomes, followed by RF and XGBoost. The model’s calibration and clinical utility were determined through calibration curves, Brier scores, and DCA, demonstrating its potential relevance in clinical decision-making. CLINICALTRIAL
- Open Access
- 26 September 2024
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 26 (5) , 1746-1747
Transcutaneous parallel suture plication to fixate a difficult-to-cannulate brachiobasilic fistula: A case presentation
We describe a patient with a matured transposed brachiobasilic fistula that was difficult to cannulate due to “rolling” and the inability to fixate. After placing multiple parallel transcutaneous sutures close to the fistula, there were no difficulties with needling. Even after removing the sutures, cannulation went uneventful.
- 26 September 2024
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 26 (5) , 1746-1747
Open AccessTranscutaneous parallel suture plication to fixate a difficult-to-cannulate brachiobasilic fistula: A case presentation
We describe a patient with a matured transposed brachiobasilic fistula that was difficult to cannulate due to “rolling” and the inability to fixate. After placing multiple parallel transcutaneous sutures close to the fistula, there were no difficulties with needling. Even after removing the sutures, cannulation went uneventful.
- Open Access
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2379-2390
An Implantable Magnetic Drive Mechanism for Non-Invasive Arteriovenous Conduit Blood Flow Control
Objective: Hemodialysis patients usually receive an arteriovenous fistula (AVF) in the arm as vascular access conduit to allow dialysis 2-3 times a week. This AVF introduces the high flow necessary for dialysis, but over time the ever-present supraphysiological flow is the leading cause of complications. This study aims to develop an implantable device able to non-invasively remove the high flow outside dialysis sessions. Methods: The developed prototype features a magnetic ring allowing external coupling and torque transmission to non-invasively control an AVF valve. Mock-up devices were implanted into arm and sheep cadavers to test sizes and locations. The transmission torque, output force, and valve closure are measured for different representative skin thicknesses. Results: The prototype was placed successfully into arm and sheep cadavers. In the prototype, a maximum output force of 78.9±4.2 N, 46.7±1.9 N, 25.6±0.7 N, 13.5±0.6 N and 6.3±0.4 N could be achieved non-invasively through skin thicknesses of 1-5 mm respectively. The fistula was fully collapsible in every measurement through skin thickness up to the required 4 mm. Conclusion: The prototype satisfies the design requirements. It is fully implantable and allows closure and control of an AVF through non-invasive torque transmission. In vivo studies are pivotal in assessing functionality and understanding systemic effects. Significance: A method is introduced to transfer large amounts of energy to a medical implant for actuation of a mechanical valve trough a closed surface. This system allows non-invasive control of an AVF to reduce complications related to the permanent high flow in conventional AVFs.
- 27 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (8) , 2379-2390
Open AccessAn Implantable Magnetic Drive Mechanism for Non-Invasive Arteriovenous Conduit Blood Flow Control
Objective: Hemodialysis patients usually receive an arteriovenous fistula (AVF) in the arm as vascular access conduit to allow dialysis 2-3 times a week. This AVF introduces the high flow necessary for dialysis, but over time the ever-present supraphysiological flow is the leading cause of complications. This study aims to develop an implantable device able to non-invasively remove the high flow outside dialysis sessions. Methods: The developed prototype features a magnetic ring allowing external coupling and torque transmission to non-invasively control an AVF valve. Mock-up devices were implanted into arm and sheep cadavers to test sizes and locations. The transmission torque, output force, and valve closure are measured for different representative skin thicknesses. Results: The prototype was placed successfully into arm and sheep cadavers. In the prototype, a maximum output force of 78.9±4.2 N, 46.7±1.9 N, 25.6±0.7 N, 13.5±0.6 N and 6.3±0.4 N could be achieved non-invasively through skin thicknesses of 1-5 mm respectively. The fistula was fully collapsible in every measurement through skin thickness up to the required 4 mm. Conclusion: The prototype satisfies the design requirements. It is fully implantable and allows closure and control of an AVF through non-invasive torque transmission. In vivo studies are pivotal in assessing functionality and understanding systemic effects. Significance: A method is introduced to transfer large amounts of energy to a medical implant for actuation of a mechanical valve trough a closed surface. This system allows non-invasive control of an AVF to reduce complications related to the permanent high flow in conventional AVFs.
- 3 February 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 67 (5) , 852-853
Supervised Pre-Operative Forearm Exercise to Increase Blood Vessel Diameter in Haemodialysis Patients: The PINCH Trial
- 3 February 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 67 (5) , 852-853
Supervised Pre-Operative Forearm Exercise to Increase Blood Vessel Diameter in Haemodialysis Patients: The PINCH Trial
- 11 November 2023
- Published by SAGE Publications in Vascular
- Vol. 32 (6) , 1177-1190
High on-treatment platelet reactivity in peripheral arterial disease: A systematic review
Objectives: To highlight current evidence pertaining to the measurement methods and prevalence of high on-treatment platelet reactivity (HTPR) in patients with PAD, as well as to evaluate the relationship between HTPR and recurrent adverse cardiovascular and limb events in PAD patients. Methods: A systematic review of English-language literature on HTPR in patients with PAD. An electronic literature search of PubMed and Medline was performed in May 2021. Results: A total of 29 studies with a total number of 11,201 patients with PAD were identified. HTPR during clopidogrel treatment ranges from 9.8 to 77%, and during aspirin treatment ranges from 4.1 to 50% of PAD patients. HTPR was associated with adverse clinical outcomes. The need for limb revascularisation was higher in patients with HTPR during clopidogrel use. Similarly, HTPR during aspirin use in the PAD population was predictive of adverse cardiovascular events (HR 3.73; 95% CI, 1.43–9.81; p = .007). A wide range of techniques were applied to measure platelet resistance, without consensus on cut-off values. Furthermore, differing patient populations, a variety of antiplatelet regimens, and differing clinical endpoints highlight the high degree of heterogeneity in the studies included in this review. Conclusion: No consensus on technique or cut-off values for HTPR testing has been reached. Patients with HTPR are potentially at a greater risk of adverse limb-related and cardiovascular events than patients sensitive to antiplatelet therapy illustrating the need for clinical implementation of HTPR testing. Future research must aim for consistent methodology. Adaptation of antiplatelet therapy based on HTPR results requires further exploration.
- 11 November 2023
- Published by SAGE Publications in Vascular
- Vol. 32 (6) , 1177-1190
High on-treatment platelet reactivity in peripheral arterial disease: A systematic review
Objectives: To highlight current evidence pertaining to the measurement methods and prevalence of high on-treatment platelet reactivity (HTPR) in patients with PAD, as well as to evaluate the relationship between HTPR and recurrent adverse cardiovascular and limb events in PAD patients. Methods: A systematic review of English-language literature on HTPR in patients with PAD. An electronic literature search of PubMed and Medline was performed in May 2021. Results: A total of 29 studies with a total number of 11,201 patients with PAD were identified. HTPR during clopidogrel treatment ranges from 9.8 to 77%, and during aspirin treatment ranges from 4.1 to 50% of PAD patients. HTPR was associated with adverse clinical outcomes. The need for limb revascularisation was higher in patients with HTPR during clopidogrel use. Similarly, HTPR during aspirin use in the PAD population was predictive of adverse cardiovascular events (HR 3.73; 95% CI, 1.43–9.81; p = .007). A wide range of techniques were applied to measure platelet resistance, without consensus on cut-off values. Furthermore, differing patient populations, a variety of antiplatelet regimens, and differing clinical endpoints highlight the high degree of heterogeneity in the studies included in this review. Conclusion: No consensus on technique or cut-off values for HTPR testing has been reached. Patients with HTPR are potentially at a greater risk of adverse limb-related and cardiovascular events than patients sensitive to antiplatelet therapy illustrating the need for clinical implementation of HTPR testing. Future research must aim for consistent methodology. Adaptation of antiplatelet therapy based on HTPR results requires further exploration.
- Open Access
Optimising Access Surgery in Senior Haemodialysis Patients (OASIS): study protocol for a multicentre randomised controlled trial
Introduction Current evidence on vascular access strategies for haemodialysis patients is based on observational studies that are at high risk of selection bias. For elderly patients, autologous arteriovenous fistulas that are typically created in usual care may not be the best option because a significant proportion of fistulas either fail to mature or remain unused. In addition, long-term complications associated with arteriovenous grafts and central venous catheters may be less relevant when considering the limited life expectancy of these patients. Therefore, we designed the Optimising Access Surgery in Senior Haemodialysis Patients (OASIS) trial to determine the best strategy for vascular access creation in elderly haemodialysis patients. Methods and analysis OASIS is a multicentre randomised controlled trial with an equal participant allocation in three treatment arms. Patients aged 70 years or older who are expected to initiate haemodialysis treatment in the next 6 months or who have started haemodialysis urgently with a catheter will be enrolled. To detect and exclude patients with an unusually long life expectancy, we will use a previously published mortality prediction model after external validation. Participants allocated to the usual care arm will be treated according to current guidelines on vascular access creation and will undergo fistula creation. Participants allocated to one of the two intervention arms will undergo graft placement or catheter insertion. The primary outcome is the number of access-related interventions required for each patient-year of haemodialysis treatment. We will enrol 195 patients to have sufficient statistical power to detect an absolute decrease of 0.80 interventions per year. Ethics and dissemination Because of clinical equipoise, we believe it is justified to randomly allocate elderly patients to the different vascular access strategies. The study was approved by an accredited medical ethics review committee. The results will be disseminated through peer-reviewed publications and will be implemented in clinical practice guidelines. Trial registration number NL7933. Protocol version and date V.5, 25 February 2021.
Open AccessOptimising Access Surgery in Senior Haemodialysis Patients (OASIS): study protocol for a multicentre randomised controlled trial
Introduction Current evidence on vascular access strategies for haemodialysis patients is based on observational studies that are at high risk of selection bias. For elderly patients, autologous arteriovenous fistulas that are typically created in usual care may not be the best option because a significant proportion of fistulas either fail to mature or remain unused. In addition, long-term complications associated with arteriovenous grafts and central venous catheters may be less relevant when considering the limited life expectancy of these patients. Therefore, we designed the Optimising Access Surgery in Senior Haemodialysis Patients (OASIS) trial to determine the best strategy for vascular access creation in elderly haemodialysis patients. Methods and analysis OASIS is a multicentre randomised controlled trial with an equal participant allocation in three treatment arms. Patients aged 70 years or older who are expected to initiate haemodialysis treatment in the next 6 months or who have started haemodialysis urgently with a catheter will be enrolled. To detect and exclude patients with an unusually long life expectancy, we will use a previously published mortality prediction model after external validation. Participants allocated to the usual care arm will be treated according to current guidelines on vascular access creation and will undergo fistula creation. Participants allocated to one of the two intervention arms will undergo graft placement or catheter insertion. The primary outcome is the number of access-related interventions required for each patient-year of haemodialysis treatment. We will enrol 195 patients to have sufficient statistical power to detect an absolute decrease of 0.80 interventions per year. Ethics and dissemination Because of clinical equipoise, we believe it is justified to randomly allocate elderly patients to the different vascular access strategies. The study was approved by an accredited medical ethics review committee. The results will be disseminated through peer-reviewed publications and will be implemented in clinical practice guidelines. Trial registration number NL7933. Protocol version and date V.5, 25 February 2021.
- 1 June 2021
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 224 (6) , 617.e1-617.e14
Assessment of fitness to perform using a validated self-test in obstetric and gynecological night shifts in the Netherlands
- 1 June 2021
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 224 (6) , 617.e1-617.e14
Assessment of fitness to perform using a validated self-test in obstetric and gynecological night shifts in the Netherlands