Muzammil Kuddushi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muzammil Kuddushi has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Naved I. Malek
Ionic Liquids Research Laboratory, Department of Chemistry, Sardar Vallabhbhai National Institute of Technology, Surat-395007, India
13 shared publications - Xuehua Zhang
Department of Chemical and Materials Engineering University of Alberta Edmonton Alberta Canada
7 shared publications Ankit Shah
5 shared publications- Omar A. El Seoud
University of São Paulo
5 shared publications Sargam Rajput
Applied Chemistry Department S.V. National Institute of Technology Surat 395007 Gujarat India
5 shared publicationsNaved I. Malek
4 shared publications
Latest Publications
- 22 November 2026
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
Zein Protein-Ionic Liquid-Based Transdermal Patch for Localized and Controlled Drug Delivery of 5- Fluorouracil
Skin cancer remains a major therapeutic challenge due to the requirement of localized and controlled drug delivery with minimally invasive and reduced cytotoxicity. One of the biggest challenges in the treatment of skin cancer is the creation of multifunctional biomaterials that can deliver drugs locally and sustainably. Topical drug delivery offers a non-invasive and patient-compliant approach for targeted chemotherapy by reducing side effects. Herein, we report the development of a plant-derived protein-based transparent, self-healable transdermal patch prepared by incorporating zein protein and biocompatible choline-fatty acid-based ionic liquids (ILs) with varied functionality choline-linoleate ([Cho][Lin] and choline-oleate [Cho][Ole]) for the localized delivery of chemotherapeutic drug to prevent skin cancer progression. Choline-based ILs were prepared by utilizing fatty acids as counterions. Zein (10% w/v) was dissolved in aqueous ionic liquid(IL) solutions containing 5-Fluorouracil (5-FU) to prepare the patch using the freeze-thaw procedure. The presence of ionic liquids enhanced drug permeation by 11.74% w/w and promoted intermolecular interactions with zein protein. The resulting transdermal patch exhibited exceptional transparency, mechanical robustness (3.7 N), adhesive, autonomous self-healing capability, flexibility, and excellent transdermal flux (101.76 μg/cm2/h). An in vitro drug permeation study of transdermal patches using goat skin was conducted with a Franz diffusion cell, demonstrating cumulative permeation of [Cho][Lin] at 1334.63 μg/cm2 and [Cho][Ole] at 868.31 μg/cm2 over a 48 h evaluation period. The transdermal patch shows cell viability exceeding 100% on a normal cell line (L-929), confirming its potential for safe topical application. In vitro biological studies show effective cytotoxicity against skin cancer cell lines (A431). Overall, this study confirms that prepared transdermal patches provide a next-generation transdermal system for localized skin cancer treatment.
- 22 November 2026
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
Zein Protein-Ionic Liquid-Based Transdermal Patch for Localized and Controlled Drug Delivery of 5- Fluorouracil
Skin cancer remains a major therapeutic challenge due to the requirement of localized and controlled drug delivery with minimally invasive and reduced cytotoxicity. One of the biggest challenges in the treatment of skin cancer is the creation of multifunctional biomaterials that can deliver drugs locally and sustainably. Topical drug delivery offers a non-invasive and patient-compliant approach for targeted chemotherapy by reducing side effects. Herein, we report the development of a plant-derived protein-based transparent, self-healable transdermal patch prepared by incorporating zein protein and biocompatible choline-fatty acid-based ionic liquids (ILs) with varied functionality choline-linoleate ([Cho][Lin] and choline-oleate [Cho][Ole]) for the localized delivery of chemotherapeutic drug to prevent skin cancer progression. Choline-based ILs were prepared by utilizing fatty acids as counterions. Zein (10% w/v) was dissolved in aqueous ionic liquid(IL) solutions containing 5-Fluorouracil (5-FU) to prepare the patch using the freeze-thaw procedure. The presence of ionic liquids enhanced drug permeation by 11.74% w/w and promoted intermolecular interactions with zein protein. The resulting transdermal patch exhibited exceptional transparency, mechanical robustness (3.7 N), adhesive, autonomous self-healing capability, flexibility, and excellent transdermal flux (101.76 μg/cm2/h). An in vitro drug permeation study of transdermal patches using goat skin was conducted with a Franz diffusion cell, demonstrating cumulative permeation of [Cho][Lin] at 1334.63 μg/cm2 and [Cho][Ole] at 868.31 μg/cm2 over a 48 h evaluation period. The transdermal patch shows cell viability exceeding 100% on a normal cell line (L-929), confirming its potential for safe topical application. In vitro biological studies show effective cytotoxicity against skin cancer cell lines (A431). Overall, this study confirms that prepared transdermal patches provide a next-generation transdermal system for localized skin cancer treatment.
- 30 June 2026
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 14 (5)
Engineering a sustainable microbubble-enhanced cold atmospheric plasma reactor for high-efficiency algal removal
- 30 June 2026
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 14 (5)
Engineering a sustainable microbubble-enhanced cold atmospheric plasma reactor for high-efficiency algal removal
- 30 January 2026
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 9 (4) , 1951-1964
Stretchable and Adhesive SeNPs-Loaded Strong Hydrogel Film with Multifunctional Bioactivity toward Wound Healing
In the field of wound care, the demand for effective materials that combine strong mechanical performance with bioactivity is crucial. This study presents a multifunctional, stretchable, and adhesive hydrogel film composed of carboxymethylcellulose (CMC), punicalagin (PUN), glycerol (GLY), and poly(3,4-ethylenedioxythiophene) polystyrenesulfonate (PEDOT:PSS), specifically designed for advanced wound healing applications. The hydrogel film exhibits high mechanical strength, elasticity, and reliable adhesion, making it suitable for dynamic wound environments. Selenium nanoparticles (SeNPs) were incorporated to enhance the hydrogel's bioactive properties. The SeNP-integrated hydrogel demonstrates antibacterial, antibiofilm, and antifungal activity, along with strong antioxidant capacity that supports cell proliferation. These attributes are essential for accelerating tissue repair, reducing infection, and mitigating oxidative stress, thereby improving the wound healing process. Overall, the SeNP-loaded hydrogel film represents a combination of mechanical robustness, effective adhesion, and multifunctional biological activity, highlighting its potential as a therapeutic platform for wound management.
- 30 January 2026
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 9 (4) , 1951-1964
Stretchable and Adhesive SeNPs-Loaded Strong Hydrogel Film with Multifunctional Bioactivity toward Wound Healing
In the field of wound care, the demand for effective materials that combine strong mechanical performance with bioactivity is crucial. This study presents a multifunctional, stretchable, and adhesive hydrogel film composed of carboxymethylcellulose (CMC), punicalagin (PUN), glycerol (GLY), and poly(3,4-ethylenedioxythiophene) polystyrenesulfonate (PEDOT:PSS), specifically designed for advanced wound healing applications. The hydrogel film exhibits high mechanical strength, elasticity, and reliable adhesion, making it suitable for dynamic wound environments. Selenium nanoparticles (SeNPs) were incorporated to enhance the hydrogel's bioactive properties. The SeNP-integrated hydrogel demonstrates antibacterial, antibiofilm, and antifungal activity, along with strong antioxidant capacity that supports cell proliferation. These attributes are essential for accelerating tissue repair, reducing infection, and mitigating oxidative stress, thereby improving the wound healing process. Overall, the SeNP-loaded hydrogel film represents a combination of mechanical robustness, effective adhesion, and multifunctional biological activity, highlighting its potential as a therapeutic platform for wound management.
- Open Access
- 28 October 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (48) , 28091-28103
Multifunctional and stimuli-responsive ionic liquid-polymeric hydrogel: a promising platform for co-drug delivery in cancer treatment
Designing intelligent drug delivery systems that offer high drug loading, site-specific release, and improved therapeutic outcomes is crucial to overcome the limitations of conventional cancer treatments.
- 28 October 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (48) , 28091-28103
Open AccessMultifunctional and stimuli-responsive ionic liquid-polymeric hydrogel: a promising platform for co-drug delivery in cancer treatment
Designing intelligent drug delivery systems that offer high drug loading, site-specific release, and improved therapeutic outcomes is crucial to overcome the limitations of conventional cancer treatments.
- 7 May 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (19) , 12030-12037
Transparent Janus Nanofibers for Use in Blood-Contact Applications
Kidney failure occurs when the kidneys can no longer effectively filter waste compounds from the blood, leading to a systemic accumulation of uremic toxins that disrupt hemostasis. Non-specific protein adsorption at the blood-material interface is well-known to direct subsequent host responses. Thus, to develop blood-contacting materials that may become an alternative to traditional dialysis membranes, we explored the effect that uremic toxins have on the adsorption of plasma proteins to Janus membranes. A human plasma system infused with 26 major uremic toxins was designed to replicate the concentrations found in kidney failure patients. This system allowed for the analysis of adsorbed human plasma proteins and clot formation in normal and toxin-treated plasma in the presence of polycaprolactone (PCL)/ethylene vinyl alcohol (EVOH) nanofibers. The findings revealed that uremic toxins significantly increased protein adsorption on PCL/EVOH nanofiber meshes without causing increased clot formation, indicating a lack of enzymatic activation despite higher protein adsorption. Furthermore, the study suggested that unmodified PCL/EVOH surfaces have the potential to trigger a strong humoral immune response, emphasizing the need to understand these interactions for the development of personalized treatment strategies for patients with kidney failure.
- 7 May 2025
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 41 (19) , 12030-12037
Transparent Janus Nanofibers for Use in Blood-Contact Applications
Kidney failure occurs when the kidneys can no longer effectively filter waste compounds from the blood, leading to a systemic accumulation of uremic toxins that disrupt hemostasis. Non-specific protein adsorption at the blood-material interface is well-known to direct subsequent host responses. Thus, to develop blood-contacting materials that may become an alternative to traditional dialysis membranes, we explored the effect that uremic toxins have on the adsorption of plasma proteins to Janus membranes. A human plasma system infused with 26 major uremic toxins was designed to replicate the concentrations found in kidney failure patients. This system allowed for the analysis of adsorbed human plasma proteins and clot formation in normal and toxin-treated plasma in the presence of polycaprolactone (PCL)/ethylene vinyl alcohol (EVOH) nanofibers. The findings revealed that uremic toxins significantly increased protein adsorption on PCL/EVOH nanofiber meshes without causing increased clot formation, indicating a lack of enzymatic activation despite higher protein adsorption. Furthermore, the study suggested that unmodified PCL/EVOH surfaces have the potential to trigger a strong humoral immune response, emphasizing the need to understand these interactions for the development of personalized treatment strategies for patients with kidney failure.
- Top Cited PapersOpen Access
- 10 March 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (15) , 2759-2781
Recent advances in nanoprecipitation: from mechanistic insights to applications in nanomaterial synthesis
Nanoprecipitation is a versatile, low-energy technique for synthesizing nanomaterials through phase separation, enabling precise tuning of nanomaterial properties.
- 10 March 2025
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 21 (15) , 2759-2781
Top Cited PapersOpen AccessRecent advances in nanoprecipitation: from mechanistic insights to applications in nanomaterial synthesis
Nanoprecipitation is a versatile, low-energy technique for synthesizing nanomaterials through phase separation, enabling precise tuning of nanomaterial properties.
- 22 January 2025
- Published by Wiley in Biopolymers
- Vol. 116 (2) , e23656
Evaluating Electrospun Polycaprolactone Fibers for Blood‐Contacting Applications
When the kidneys are injured, uremic toxins (UTXs) accumulate in the body, affecting other tissues and causing a loss of essential body functions. This study investigated the adsorption of blood plasma‐laden UTXs on the surface of PCL fibers to assess their potential as an alternative to membrane dialysis materials. Using plasma containing 26 UTXs at a concentration similar to that found in end‐stage kidney disease patients, we analyzed the adsorbed proteins and examined clot formation in normal and toxin‐treated plasma in the presence of PCL fibers. Our findings revealed that the presence of UTXs significantly increased the adsorption of proteins on PCL fiber meshes, without leading to increased clot formation. This suggests a lack of enzymatic activation despite the higher protein adsorption. Additionally, our study indicates that unmodified PCL surfaces have the potential to trigger a strong humoral immune response, underscoring the importance of understanding these interactions for the development of personalized treatment approaches for patients with kidney failure.
- 22 January 2025
- Published by Wiley in Biopolymers
- Vol. 116 (2) , e23656
Evaluating Electrospun Polycaprolactone Fibers for Blood‐Contacting Applications
When the kidneys are injured, uremic toxins (UTXs) accumulate in the body, affecting other tissues and causing a loss of essential body functions. This study investigated the adsorption of blood plasma‐laden UTXs on the surface of PCL fibers to assess their potential as an alternative to membrane dialysis materials. Using plasma containing 26 UTXs at a concentration similar to that found in end‐stage kidney disease patients, we analyzed the adsorbed proteins and examined clot formation in normal and toxin‐treated plasma in the presence of PCL fibers. Our findings revealed that the presence of UTXs significantly increased the adsorption of proteins on PCL fiber meshes, without leading to increased clot formation. This suggests a lack of enzymatic activation despite the higher protein adsorption. Additionally, our study indicates that unmodified PCL surfaces have the potential to trigger a strong humoral immune response, underscoring the importance of understanding these interactions for the development of personalized treatment approaches for patients with kidney failure.
- Open Access
- 8 January 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Evaluating electrospun polycaprolactone fibers for blood-contacting applications
When the kidneys are injured, uremic toxins (UTXs) accumulate in the body, affecting other tissues and causing a loss of essential body functions. This study investigated the adsorption of blood plasma-laden uremic toxins on the surface of PCL fibers to assess their potential as an alternative to membrane dialysis materials. Using plasma containing 25 uremic toxins at a concentration similar to that found in end-stage kidney disease patients, we analyzed the adsorbed proteins and examined clot formation in normal and toxin-treated plasma in the presence of PCL fiberss. Our findings revealed that the presence of uremic toxins significantly increased the adsorption of proteins on PCL fiber meshes, without leading to increased clot formation. This suggests a lack of enzymatic activation despite the higher protein adsorption. Additionally, our study indicates that unmodified PCL surfaces have the potential to trigger a strong humoral immune response, underscoring the importance of understanding these interactions for the development of personalized treatment approaches for patients with kidney failure.
- 8 January 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessEvaluating electrospun polycaprolactone fibers for blood-contacting applications
When the kidneys are injured, uremic toxins (UTXs) accumulate in the body, affecting other tissues and causing a loss of essential body functions. This study investigated the adsorption of blood plasma-laden uremic toxins on the surface of PCL fibers to assess their potential as an alternative to membrane dialysis materials. Using plasma containing 25 uremic toxins at a concentration similar to that found in end-stage kidney disease patients, we analyzed the adsorbed proteins and examined clot formation in normal and toxin-treated plasma in the presence of PCL fiberss. Our findings revealed that the presence of uremic toxins significantly increased the adsorption of proteins on PCL fiber meshes, without leading to increased clot formation. This suggests a lack of enzymatic activation despite the higher protein adsorption. Additionally, our study indicates that unmodified PCL surfaces have the potential to trigger a strong humoral immune response, underscoring the importance of understanding these interactions for the development of personalized treatment approaches for patients with kidney failure.
- 7 November 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (46) , 63389-63403
Transparent and Mechanically Robust Janus Nanofiber Membranes for Open Wound Healing and Monitoring
- 7 November 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (46) , 63389-63403
Transparent and Mechanically Robust Janus Nanofiber Membranes for Open Wound Healing and Monitoring
- 25 August 2023
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 6 (9) , 3810-3822
A Transparent, Tough and Self-Healable Biopolymeric Composites Hydrogel for Open Wound Management
Modern healthcare engineering requires a wound dressing solution supported by materials with outstanding features such as high biological compatibility, strong mechanical strength, and higher transparency with effective antibacterial properties. Here, we present a unique hydrogel technology consisting of two negatively charged biopolymers and a positively charged synthetic polymer. The interaction between charged polymers through hydrogen bonds has been created, which are revealed in the simulation by density functional theory and Fourier transform infrared spectra of individual polymers and the hydrogel film. The transparent hydrogel film dressings showed excellent stretchability, a higher water swelling ratio (60%), and strong mechanical strength (∼100 MPa) with self-healing abilities (85-90%). The fabricated hydrogel film showed stable blood clots (within 119 ± 15 s) with rapid hemostasis (E. coli and S. aureus bacterial strains. In addition, the obtained hydrogel film also showed excellent cell viability on mouse fibroblast cells. With their enormous amenability to modification, these hydrogel films may serve as promising biomaterials for wound dressing applications.
- 25 August 2023
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 6 (9) , 3810-3822
A Transparent, Tough and Self-Healable Biopolymeric Composites Hydrogel for Open Wound Management
Modern healthcare engineering requires a wound dressing solution supported by materials with outstanding features such as high biological compatibility, strong mechanical strength, and higher transparency with effective antibacterial properties. Here, we present a unique hydrogel technology consisting of two negatively charged biopolymers and a positively charged synthetic polymer. The interaction between charged polymers through hydrogen bonds has been created, which are revealed in the simulation by density functional theory and Fourier transform infrared spectra of individual polymers and the hydrogel film. The transparent hydrogel film dressings showed excellent stretchability, a higher water swelling ratio (60%), and strong mechanical strength (∼100 MPa) with self-healing abilities (85-90%). The fabricated hydrogel film showed stable blood clots (within 119 ± 15 s) with rapid hemostasis (E. coli and S. aureus bacterial strains. In addition, the obtained hydrogel film also showed excellent cell viability on mouse fibroblast cells. With their enormous amenability to modification, these hydrogel films may serve as promising biomaterials for wound dressing applications.