Rui Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rui Shi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Francesco Gavelli
Department of Translational Medicine, Università degli Studi del Piemonte Orientale, 28100 Novara, Italy
2 shared publications - Jean-Louis Teboul
Faculté de Médecine Paris-Saclay, Université Paris-Saclay, Le Kremlin-Bicêtre, France
2 shared publications - Xavier Monnet
AP-HP, Service de Médecine Intensive-Réanimation, Hôpital de Bicêtre, DMU 4 CORREVE, IHU SEPSIS, CARMAS, Université Paris-Saclay, Le Kremlin-Bicêtre, France
2 shared publications - Alexandra Beurton
Service de Médecine Intensive-Réanimation, Université Paris-Saclay, AP-HP, Hôpital de Bicêtre, DMU CORREVE, Inserm UMR S_999, FHU SEPSIS, CARMAS, Le Kremlin-Bicêtre, France
1 shared publication - Arthur Pavot
Service des Maladies Respiratoires et des Explorations Fonctionnelles Respiratoires, CHU de Bordeaux, Hôpital Haut Lévèque, Avenue du Haut Lévêque, Pessac 33604, France; Univ-Bordeaux, Centre de Recherche cardio-thoracique de Bordeaux, U1045, CIC 1401. Avenue du Haut Lévêque, Pessac F-33604, France
1 shared publication - Danila Azzolina
Biostatistics and Clinical Trial Methodology Unit,Clinical Research Center DEMeTra, Department of Translational Medical Science, University of Naples Federico II, University of Naples Federico II, Naples, Italy
1 shared publication
Latest Publications
- Open Access
- 28 August 2021
- Published by Elsevier in Annals of Intensive Care
- Vol. 11 (1) , 1-10
Bioreactance reliably detects preload responsiveness by the end-expiratory occlusion test when averaging and refresh times are shortened
- 28 August 2021
- Published by Elsevier in Annals of Intensive Care
- Vol. 11 (1) , 1-10
Open AccessBioreactance reliably detects preload responsiveness by the end-expiratory occlusion test when averaging and refresh times are shortened
- Open Access
- 18 March 2021
- Published by Springer Nature in Critical Care
- Vol. 25 (1) , 1-12
Do changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation?
Background: In patients ventilated with tidal volume (Vt) < 8 mL/kg, pulse pressure variation (PPV) and, likely, the variation of distensibility of the inferior vena cava diameter (IVCDV) are unable to detect preload responsiveness. In this condition, passive leg raising (PLR) could be used, but it requires a measurement of cardiac output. The tidal volume (Vt) challenge (PPV changes induced by a 1-min increase in Vt from 6 to 8 mL/kg) is another alternative, but it requires an arterial line. We tested whether, in case of Vt = 6 mL/kg, the effects of PLR could be assessed through changes in PPV (ΔPPVPLR) or in IVCDV (ΔIVCDVPLR) rather than changes in cardiac output, and whether the effects of the Vt challenge could be assessed by changes in IVCDV (ΔIVCDVVt) rather than changes in PPV (ΔPPVVt). Methods: In 30 critically ill patients without spontaneous breathing and cardiac arrhythmias, ventilated with Vt = 6 mL/kg, we measured cardiac index (CI) (PiCCO2), IVCDV and PPV before/during a PLR test and before/during a Vt challenge. A PLR-induced increase in CI ≥ 10% defined preload responsiveness. Results: At baseline, IVCDV was not different between preload responders (n = 15) and non-responders. Compared to non-responders, PPV and IVCDV decreased more during PLR (by − 38 ± 16% and − 26 ± 28%, respectively) and increased more during the Vt challenge (by 64 ± 42% and 91 ± 72%, respectively) in responders. ∆PPVPLR, expressed either as absolute or as percent relative changes, detected preload responsiveness (area under the receiver operating curve, AUROC: 0.98 ± 0.02 for both). ∆IVCDVPLR detected preload responsiveness only when expressed in absolute changes (AUROC: 0.76 ± 0.10), not in relative changes. ∆PPVVt, expressed as absolute or percent relative changes, detected preload responsiveness (AUROC: 0.98 ± 0.02 and 0.94 ± 0.04, respectively). This was also the case for ∆IVCDVVt, but the diagnostic threshold (1 point or 4%) was below the least significant change of IVCDV (9[3–18]%). Conclusions: During mechanical ventilation with Vt = 6 mL/kg, the effects of PLR can be assessed by changes in PPV. If IVCDV is used, it should be expressed in percent and not absolute changes. The effects of the Vt challenge can be assessed on PPV, but not on IVCDV, since the diagnostic threshold is too small compared to the reproducibility of this variable. Trial registration: Agence Nationale de Sécurité du Médicament et des Produits de santé: ID-RCB: 2016-A00893-48.
- 18 March 2021
- Published by Springer Nature in Critical Care
- Vol. 25 (1) , 1-12
Open AccessDo changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation?
Background: In patients ventilated with tidal volume (Vt) < 8 mL/kg, pulse pressure variation (PPV) and, likely, the variation of distensibility of the inferior vena cava diameter (IVCDV) are unable to detect preload responsiveness. In this condition, passive leg raising (PLR) could be used, but it requires a measurement of cardiac output. The tidal volume (Vt) challenge (PPV changes induced by a 1-min increase in Vt from 6 to 8 mL/kg) is another alternative, but it requires an arterial line. We tested whether, in case of Vt = 6 mL/kg, the effects of PLR could be assessed through changes in PPV (ΔPPVPLR) or in IVCDV (ΔIVCDVPLR) rather than changes in cardiac output, and whether the effects of the Vt challenge could be assessed by changes in IVCDV (ΔIVCDVVt) rather than changes in PPV (ΔPPVVt). Methods: In 30 critically ill patients without spontaneous breathing and cardiac arrhythmias, ventilated with Vt = 6 mL/kg, we measured cardiac index (CI) (PiCCO2), IVCDV and PPV before/during a PLR test and before/during a Vt challenge. A PLR-induced increase in CI ≥ 10% defined preload responsiveness. Results: At baseline, IVCDV was not different between preload responders (n = 15) and non-responders. Compared to non-responders, PPV and IVCDV decreased more during PLR (by − 38 ± 16% and − 26 ± 28%, respectively) and increased more during the Vt challenge (by 64 ± 42% and 91 ± 72%, respectively) in responders. ∆PPVPLR, expressed either as absolute or as percent relative changes, detected preload responsiveness (area under the receiver operating curve, AUROC: 0.98 ± 0.02 for both). ∆IVCDVPLR detected preload responsiveness only when expressed in absolute changes (AUROC: 0.76 ± 0.10), not in relative changes. ∆PPVVt, expressed as absolute or percent relative changes, detected preload responsiveness (AUROC: 0.98 ± 0.02 and 0.94 ± 0.04, respectively). This was also the case for ∆IVCDVVt, but the diagnostic threshold (1 point or 4%) was below the least significant change of IVCDV (9[3–18]%). Conclusions: During mechanical ventilation with Vt = 6 mL/kg, the effects of PLR can be assessed by changes in PPV. If IVCDV is used, it should be expressed in percent and not absolute changes. The effects of the Vt challenge can be assessed on PPV, but not on IVCDV, since the diagnostic threshold is too small compared to the reproducibility of this variable. Trial registration: Agence Nationale de Sécurité du Médicament et des Produits de santé: ID-RCB: 2016-A00893-48.
- Open Access
- 14 July 2020
- Published by Springer Nature in Critical Care
- Vol. 24 (1) , 1-5
Benefit of hydrocortisone, thiamine, and vitamin C for patients with sepsis or septic shock? Too early to draw conclusions
- 14 July 2020
- Published by Springer Nature in Critical Care
- Vol. 24 (1) , 1-5
Open AccessBenefit of hydrocortisone, thiamine, and vitamin C for patients with sepsis or septic shock? Too early to draw conclusions