Narayan Nahak
Research Subjects
Narayan Nahak has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Samarjeet Satapathy
Siksha ‘O’Anusandhan Deemed to Be University
8 shared publications- Samarjeet Satapathy
Siksha O Anusandhan, Fac Engn & Technol, Bhubaneswar, Odisha, India
7 shared publications Ramachandra Agrawal
Siksha ‘O’Anusandhan Deemed to Be University
4 shared publications- Akshaya Kumar Patra
Department of EEE, ITER, Siksha ‘O’ Anusandhan University, Bhubaneswar, India
3 shared publications - Alok Kumar Mishra
Department of Electrical and Electronics Engineering, ITER, SOA Deemed to be University, Bhubaneswar, India
3 shared publications Omkar Satapathy
Department of Electrical Engineering Siksha ‘O’ Anusandhan Deemed to be University Bhubaneswar India
3 shared publications
Latest Publications
- 26 August 2025
- Published by Springer Nature
- p. 141-151
Multi-objective Manta Ray Foraging Optimized Fractional SSSC Control Action for Enhancing Small Signal Stability Action
- 26 August 2025
- Published by Springer Nature
- p. 141-151
Multi-objective Manta Ray Foraging Optimized Fractional SSSC Control Action for Enhancing Small Signal Stability Action
- 26 August 2025
- Published by Springer Nature
- p. 153-162
Damping of Angular Frequency Variation for a Grid Connected Microgrid by Optimal Fuzzy Controller
- 26 August 2025
- Published by Springer Nature
- p. 153-162
Damping of Angular Frequency Variation for a Grid Connected Microgrid by Optimal Fuzzy Controller
- Open Access
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 82065-82083
A Real Time Coordinated Hydro Governor With Dual STATCOM for Low Frequency Oscillation Damping Using Hybrid Mean DE & TVAPSO
Hydro power generation is one of the most viable renewable sources to meet future energy demand and being a synchronous source, it has also the capability to enhance power system stability. Low frequency oscillations in power grid poses several challenges to operators and need to be damped at earlier stage to maintain stability of power system. The hydro turbine governors usually impart negative damping to these oscillations. So, there can be modification in governor control action to impart damping of these oscillations. In present work the hydro governors are phase compensated and coordinated with dual static synchronous compensator (STATCOM) so as to provide sufficient damping torque. A state space model of dual STATCOM with compensated hydro governor has been developed. Sudden change in reference voltage, uncertain solar and wind penetrations with plug-in electric vehicle as load being considered with different experimentations to impart critical oscillations in power system and proposed controller has been employed to damp these oscillations. Multimachine two area four hydro generators, 39 bus systems with 10 generators and modified IEEE 68 bus system with sixteen generators at different operating conditions have been investigated with proposed controller for oscillation damping. A new multi-objective mean Differential Evolution with time varying accelerated Particle Swarm Optimization algorithm (MeDETVAPSO) has been implemented to tune controller parameters. The proposed controller shows less values of settling time, oscillations peak value and imparting high damping ratio. Settling time, oscillations peak value and minimum damping ratio with proposed controller have been observed as 1.638s, 0.000375pu and 0.987 respectively. These experimentations have been conducted in MATLAB Simulink and verified with real time simulation based in OPAL-RT 4510. The damping capability of proposed controller has been found to be better in contrast to power system stabilizer (PSS), compensated hydro governor, dual STATCOM and performance of MeDETVAPSO has been observed to be better than PSO and DE to tune controller parameters.
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 82065-82083
Open AccessA Real Time Coordinated Hydro Governor With Dual STATCOM for Low Frequency Oscillation Damping Using Hybrid Mean DE & TVAPSO
Hydro power generation is one of the most viable renewable sources to meet future energy demand and being a synchronous source, it has also the capability to enhance power system stability. Low frequency oscillations in power grid poses several challenges to operators and need to be damped at earlier stage to maintain stability of power system. The hydro turbine governors usually impart negative damping to these oscillations. So, there can be modification in governor control action to impart damping of these oscillations. In present work the hydro governors are phase compensated and coordinated with dual static synchronous compensator (STATCOM) so as to provide sufficient damping torque. A state space model of dual STATCOM with compensated hydro governor has been developed. Sudden change in reference voltage, uncertain solar and wind penetrations with plug-in electric vehicle as load being considered with different experimentations to impart critical oscillations in power system and proposed controller has been employed to damp these oscillations. Multimachine two area four hydro generators, 39 bus systems with 10 generators and modified IEEE 68 bus system with sixteen generators at different operating conditions have been investigated with proposed controller for oscillation damping. A new multi-objective mean Differential Evolution with time varying accelerated Particle Swarm Optimization algorithm (MeDETVAPSO) has been implemented to tune controller parameters. The proposed controller shows less values of settling time, oscillations peak value and imparting high damping ratio. Settling time, oscillations peak value and minimum damping ratio with proposed controller have been observed as 1.638s, 0.000375pu and 0.987 respectively. These experimentations have been conducted in MATLAB Simulink and verified with real time simulation based in OPAL-RT 4510. The damping capability of proposed controller has been found to be better in contrast to power system stabilizer (PSS), compensated hydro governor, dual STATCOM and performance of MeDETVAPSO has been observed to be better than PSO and DE to tune controller parameters.
- 15 May 2024
- Published by Springer Nature
- p. 571-581
Optimal Fractional UPFC Based Damping Action for Variable Solar Penetration
- 15 May 2024
- Published by Springer Nature
- p. 571-581
Optimal Fractional UPFC Based Damping Action for Variable Solar Penetration
- 15 May 2024
- Published by Springer Nature
- p. 583-594
Memetic SSA Tuned Compensated Hydro Governor to Damp Power System Oscillations for Variable Wind Penetrations
- 15 May 2024
- Published by Springer Nature
- p. 583-594
Memetic SSA Tuned Compensated Hydro Governor to Damp Power System Oscillations for Variable Wind Penetrations
- 9 August 2023
- Published by Springer Nature
- p. 213-224
Lightning Search Algorithm Tuned Simultaneous Water Turbine Governor Actions for Power Oscillation Damping
- 9 August 2023
- Published by Springer Nature
- p. 213-224
Lightning Search Algorithm Tuned Simultaneous Water Turbine Governor Actions for Power Oscillation Damping
- 18 February 2023
- Published by Springer Nature
- p. 119-132
Enhancement of Oscillatory Stability of a Grid Integrated Microgrid by Optimized Governor Damping Action
- 18 February 2023
- Published by Springer Nature
- p. 119-132
Enhancement of Oscillatory Stability of a Grid Integrated Microgrid by Optimized Governor Damping Action
- 1 January 2023
- Published by Taru Publications in Journal of Statistics and Management Systems
- Vol. 26 (1) , 43-52
Optimal fractional SSSC damping action for variable wind penetrations
An optimal fractional SSSC based control action has been proposed in this work for enhancing small signal stability of power system pertaining to intermittent variations in wind penetrations. The parameters of controllers are tuned by sailfish algorithm and ITAE based objective function has been chosen for minimization problem. A three machine system has been considered in this work with different operating conditions and step with random variations in wind penetrations have been executed with different machines and subject to which the system response and eigen values are analyzed. Based on system response it is observed that subject to intermittent variations in wind source the small signal stability is hampered due to increased power system oscillations and by properly tuning the fractional lead-lag control action based on static synchronous series compensator. These oscillations can be damped efficiently. The performance of proposed sailfish algorithm (SFA) tuned SSSC controlled action has been compared with PSO and DE algorithms subject to different case studies.
- 1 January 2023
- Published by Taru Publications in Journal of Statistics and Management Systems
- Vol. 26 (1) , 43-52
Optimal fractional SSSC damping action for variable wind penetrations
An optimal fractional SSSC based control action has been proposed in this work for enhancing small signal stability of power system pertaining to intermittent variations in wind penetrations. The parameters of controllers are tuned by sailfish algorithm and ITAE based objective function has been chosen for minimization problem. A three machine system has been considered in this work with different operating conditions and step with random variations in wind penetrations have been executed with different machines and subject to which the system response and eigen values are analyzed. Based on system response it is observed that subject to intermittent variations in wind source the small signal stability is hampered due to increased power system oscillations and by properly tuning the fractional lead-lag control action based on static synchronous series compensator. These oscillations can be damped efficiently. The performance of proposed sailfish algorithm (SFA) tuned SSSC controlled action has been compared with PSO and DE algorithms subject to different case studies.
- 1 January 2023
- Published by Taru Publications in Journal of Statistics and Management Systems
- Vol. 26 (1) , 23-34
Modified PSO tuned two stage lead lag STATCOM control action for small signal stability enhancement of variable wind integrated power system
- 1 January 2023
- Published by Taru Publications in Journal of Statistics and Management Systems
- Vol. 26 (1) , 23-34
Modified PSO tuned two stage lead lag STATCOM control action for small signal stability enhancement of variable wind integrated power system
- Open Access
- 19 October 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-24
A Coordinated Pumped Storage Dual Compensated Hydro Governor with PSS Action to Damp Electromechanical Power Oscillations
Subject to increasing penetrations of renewable sources like solar photovoltaic (SPV) and wind energy sources, power system oscillation damping is going to be a critical challenge for system operators. This work proposes a new dual compensated governor (DCG) in coordination with a power system stabilizer (PSS) of a pumped storage hydro plant for power oscillation damping subject to intermittent SPV and wind penetration for a hydro, wind, and SPV integrated power system. The phase lag provided by the hydro governor is compensated by additional phase lead contributed by the dual compensation, where speed and real power deviations brought by uncertain SPV and wind penetrations are simultaneously controlled by two lead-lag controllers before being applied to conventional Proportional-Integral-Derivative (PID) governor. Again, subject to critical oscillatory unstable conditions, the DCG is coordinated with PSS through a multiobjective function employing a new modified Differential Evolutionary-Particle swarm optimization (MDEPSO) algorithm. Different case studies with sudden and random SPV and wind penetrations being executed with the proposed controller considering a two area four machine and 39 bus multimachine system with pumped storage hydro units to observe system oscillations are considered. The proposed damping control action has been implemented to damp these oscillations, and the damped response has been analyzed with eigenvalue distributions and Bode plots with sensitivity analysis. The proposed action is found to be much more efficient in contrast to conventional PID governor and PSS damping action. Also, the usage of present hydro governors can be much improved by this coordinated controller action.
- 19 October 2022
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2022, 1-24
Open AccessA Coordinated Pumped Storage Dual Compensated Hydro Governor with PSS Action to Damp Electromechanical Power Oscillations
Subject to increasing penetrations of renewable sources like solar photovoltaic (SPV) and wind energy sources, power system oscillation damping is going to be a critical challenge for system operators. This work proposes a new dual compensated governor (DCG) in coordination with a power system stabilizer (PSS) of a pumped storage hydro plant for power oscillation damping subject to intermittent SPV and wind penetration for a hydro, wind, and SPV integrated power system. The phase lag provided by the hydro governor is compensated by additional phase lead contributed by the dual compensation, where speed and real power deviations brought by uncertain SPV and wind penetrations are simultaneously controlled by two lead-lag controllers before being applied to conventional Proportional-Integral-Derivative (PID) governor. Again, subject to critical oscillatory unstable conditions, the DCG is coordinated with PSS through a multiobjective function employing a new modified Differential Evolutionary-Particle swarm optimization (MDEPSO) algorithm. Different case studies with sudden and random SPV and wind penetrations being executed with the proposed controller considering a two area four machine and 39 bus multimachine system with pumped storage hydro units to observe system oscillations are considered. The proposed damping control action has been implemented to damp these oscillations, and the damped response has been analyzed with eigenvalue distributions and Bode plots with sensitivity analysis. The proposed action is found to be much more efficient in contrast to conventional PID governor and PSS damping action. Also, the usage of present hydro governors can be much improved by this coordinated controller action.