Charlotte Young
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Charlotte Young has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Aalap C. Shah
UCI Univ Calif Irvine Hlth, Anesthesiol & Perioperat Med, Orange, CA 92697 USA
1 shared publication - Amalia Aleck
Department of Anesthesiology, University of California, San Diego, San Diego, CA, United States
1 shared publication - Anne Shapiro
Department of Anesthesiology, University of California, San Diego, San Diego, CA, United States
1 shared publication - Brian Rudolph Shy
Department of Laboratory Medicine, University of California, San Francisco, San Francisco, CA, USA 94143; Gladstone-UCSF Institute of Genomic Immunology, San Francisco, CA USA 94158
1 shared publication - Camille Gwen Rogine
University of California, San Francisco
1 shared publication - Carly Deibler
San Francisco Medical Center, University of California, San Francisco, CA, United States
1 shared publication
Latest Publications
- Open Access
- 8 December 2022
- Published by JMIR Publications Inc. in JMIR Perioperative Medicine
- Vol. 5 (1) , e40831
An Accessible Clinical Decision Support System to Curtail Anesthetic Greenhouse Gases in a Large Health Network: Implementation Study
Background: Inhaled anesthetics in the operating room are potent greenhouse gases and are a key contributor to carbon emissions from health care facilities. Real-time clinical decision support (CDS) systems lower anesthetic gas waste by prompting anesthesia professionals to reduce fresh gas flow (FGF) when a set threshold is exceeded. However, previous CDS systems have relied on proprietary or highly customized anesthesia information management systems, significantly reducing other institutions’ accessibility to the technology and thus limiting overall environmental benefit. Objective: In 2018, a CDS system that lowers anesthetic gas waste using methods that can be easily adopted by other institutions was developed at the University of California San Francisco (UCSF). This study aims to facilitate wider uptake of our CDS system and further reduce gas waste by describing the implementation of the FGF CDS toolkit at UCSF and the subsequent implementation at other medical campuses within the University of California Health network. Methods: We developed a noninterruptive active CDS system to alert anesthesia professionals when FGF rates exceeded 0.7 L per minute for common volatile anesthetics. The implementation process at UCSF was documented and assembled into an informational toolkit to aid in the integration of the CDS system at other health care institutions. Before implementation, presentation-based education initiatives were used to disseminate information regarding the safety of low FGF use and its relationship to environmental sustainability. Our FGF CDS toolkit consisted of 4 main components for implementation: sustainability-focused education of anesthesia professionals, hardware integration of the CDS technology, software build of the CDS system, and data reporting of measured outcomes. Results: The FGF CDS system was successfully deployed at 5 University of California Health network campuses. Four of the institutions are independent from the institution that created the CDS system. The CDS system was deployed at each facility using the FGF CDS toolkit, which describes the main components of the technology and implementation. Each campus made modifications to the CDS tool to best suit their institution, emphasizing the versatility and adoptability of the technology and implementation framework. Conclusions: It has previously been shown that the FGF CDS system reduces anesthetic gas waste, leading to environmental and fiscal benefits. Here, we demonstrate that the CDS system can be transferred to other medical facilities using our toolkit for implementation, making the technology and associated benefits globally accessible to advance mitigation of health care–related emissions.
- 8 December 2022
- Published by JMIR Publications Inc. in JMIR Perioperative Medicine
- Vol. 5 (1) , e40831
Open AccessAn Accessible Clinical Decision Support System to Curtail Anesthetic Greenhouse Gases in a Large Health Network: Implementation Study
Background: Inhaled anesthetics in the operating room are potent greenhouse gases and are a key contributor to carbon emissions from health care facilities. Real-time clinical decision support (CDS) systems lower anesthetic gas waste by prompting anesthesia professionals to reduce fresh gas flow (FGF) when a set threshold is exceeded. However, previous CDS systems have relied on proprietary or highly customized anesthesia information management systems, significantly reducing other institutions’ accessibility to the technology and thus limiting overall environmental benefit. Objective: In 2018, a CDS system that lowers anesthetic gas waste using methods that can be easily adopted by other institutions was developed at the University of California San Francisco (UCSF). This study aims to facilitate wider uptake of our CDS system and further reduce gas waste by describing the implementation of the FGF CDS toolkit at UCSF and the subsequent implementation at other medical campuses within the University of California Health network. Methods: We developed a noninterruptive active CDS system to alert anesthesia professionals when FGF rates exceeded 0.7 L per minute for common volatile anesthetics. The implementation process at UCSF was documented and assembled into an informational toolkit to aid in the integration of the CDS system at other health care institutions. Before implementation, presentation-based education initiatives were used to disseminate information regarding the safety of low FGF use and its relationship to environmental sustainability. Our FGF CDS toolkit consisted of 4 main components for implementation: sustainability-focused education of anesthesia professionals, hardware integration of the CDS technology, software build of the CDS system, and data reporting of measured outcomes. Results: The FGF CDS system was successfully deployed at 5 University of California Health network campuses. Four of the institutions are independent from the institution that created the CDS system. The CDS system was deployed at each facility using the FGF CDS toolkit, which describes the main components of the technology and implementation. Each campus made modifications to the CDS tool to best suit their institution, emphasizing the versatility and adoptability of the technology and implementation framework. Conclusions: It has previously been shown that the FGF CDS system reduces anesthetic gas waste, leading to environmental and fiscal benefits. Here, we demonstrate that the CDS system can be transferred to other medical facilities using our toolkit for implementation, making the technology and associated benefits globally accessible to advance mitigation of health care–related emissions.
- Open Access
Hospital-Based Donor Recruitment and Pre-Donation Serologic Testing for COVID-19 Convalescent Plasma
Background: Major blood centers perform serologic testing on potential COVID-19 convalescent plasma donors retrospectively after blood donation. A hospital-based recruitment program for COVID-19 convalescent plasma (CCP) donors may be an efficient way to prospectively identify potential donors. Study Design and Methods: Patients who recovered from known or suspected COVID-19 were identified and recruited through medical record searches and public appeals. Participants were screened with a modified donor history questionnaire (DHQ), and if eligible, were consented and tested for SARS-CoV-2 antibodies (IgG and IgM). Participants who were positive for SARS-CoV-2 IgG were referred to a local blood center for convalescent plasma collection. Results: Of 179 individuals screened, 128 completed serologic testing and 89 were referred for convalescent plasma donation to a local blood center (49.7% of those screened). IgG antibodies to SARS-CoV-2 were detected in 23/51 (45.1%) of participants with suspected COVID-19 and in 66/77 (85.7%) of participants with self-reported PCR-confirmed COVID-19. Testing was performed at a median of 38 days since last symptoms. Participant age positively correlated with anti-SARS-CoV-2 IgG and IgM levels. Time since last symptoms did not correlate with IgG or IgM levels. A wide range of SARS-CoV-2 IgG levels were observed. Conclusion: A hospital based CCP donor recruitment program can prospectively identify potential CCP donors. Variability in SARS-CoV-2 IgG levels has implications for selection of CCP units for transfusion.
Open AccessHospital-Based Donor Recruitment and Pre-Donation Serologic Testing for COVID-19 Convalescent Plasma
Background: Major blood centers perform serologic testing on potential COVID-19 convalescent plasma donors retrospectively after blood donation. A hospital-based recruitment program for COVID-19 convalescent plasma (CCP) donors may be an efficient way to prospectively identify potential donors. Study Design and Methods: Patients who recovered from known or suspected COVID-19 were identified and recruited through medical record searches and public appeals. Participants were screened with a modified donor history questionnaire (DHQ), and if eligible, were consented and tested for SARS-CoV-2 antibodies (IgG and IgM). Participants who were positive for SARS-CoV-2 IgG were referred to a local blood center for convalescent plasma collection. Results: Of 179 individuals screened, 128 completed serologic testing and 89 were referred for convalescent plasma donation to a local blood center (49.7% of those screened). IgG antibodies to SARS-CoV-2 were detected in 23/51 (45.1%) of participants with suspected COVID-19 and in 66/77 (85.7%) of participants with self-reported PCR-confirmed COVID-19. Testing was performed at a median of 38 days since last symptoms. Participant age positively correlated with anti-SARS-CoV-2 IgG and IgM levels. Time since last symptoms did not correlate with IgG or IgM levels. A wide range of SARS-CoV-2 IgG levels were observed. Conclusion: A hospital based CCP donor recruitment program can prospectively identify potential CCP donors. Variability in SARS-CoV-2 IgG levels has implications for selection of CCP units for transfusion.